37. Q. What should be done?

A. Wrap the exposed wire, if you can locate it, with a piece of waste,

or if you cannot locate the short circuit, disconnect one of your cab

wires from the dynamo. This would give you the benefit of the arc lamp

and you can look for the trouble at your leisure.

38. Q. If the light goes out when steam drops back fifteen to twenty

pounds, what is the trouble?

A. Either one of the governor valves is stuck shut, short bushing No. 18

in engine cab is worn badly, allowing wheel to drop away from the

governor stand so steam passes around wheel to exhaust, or governor

springs are too weak.

The Traveling Engineers' Association to Improve the Locomotive Engine Service of American Railroads Examination Questions and Answers for Firemen for Promotion and New Men for Employment · 第 241 / 436 题