63. Q. What may be done if a combining tube is obstructed?

A. The steam valve bonnet may be removed and the obstruction forced out

with a piece of stiff wire, or uncouple the delivery pipe from the

injector and unscrew and remove the tubes; the obstruction can then be

removed and the tubes replaced.

64. Q. How is the greatest injury done to a boiler when cleaning or

knocking the fire?

A. By excessive use of the blower drawing cold air through the fire-box

and flues.

65. Q. Why does putting a large quantity of cold water into a boiler

when the throttle is closed cause the flues to leak? When is this most

serious?

A. When steam is not being used there is not much circulation of water

in the boiler, and the water entering the boiler at about 150 degrees

temperature is heavier than the water in the boiler. The cooler water

will go to the bottom and reduce the temperature in that part of the

boiler and causing the flues to contract in length as well as in

diameter and this has a tendency to pull them out of the sheet. This

will loosen them and cause them to leak. After the fire has been knocked

this tendency is much greater, and for that reason cold water should not

be put into a boiler after the fire has been knocked out. Always fill

the boiler before the fire is knocked out.

66. Q. Is warm water in the tank of any advantage in making steam

rapidly?

A. Yes; careful experiments have shown that a locomotive will generate

one per cent. more steam for every eleven degrees that the tank water is

heated; thus by heating the feed water in the tank from 39 degrees to 94

would effect a saving of five per cent.

67. Q. Then why not heat the feed water to the boiling point (212

degrees)?

A. If the feed water is heated much above 100 degrees it will not

condense enough steam in the injector to cause it to work properly. Some

injectors will work hotter water than others. It would also spoil the

paint on the tank if heated to a much higher temperature.

68. Q. At 200 pounds pressure per square inch, what is the pressure per

square foot on the sheets of a boiler?

A. About fifteen tons.

69. Q. What is the total pressure on the fire-box of a large

locomotive?

A. Over 3,000 tons.

The Traveling Engineers' Association to Improve the Locomotive Engine Service of American Railroads Examination Questions and Answers for Firemen for Promotion and New Men for Employment · 第 75 / 436 题