THE TROTTER CURVE RANGER.

This little instrument was exhibited in a somewhat crude state at the

meeting of the British Association at Newcastle in 1889. It has since

been modified in several respects, and improvements suggested by

practical use have been introduced, bringing it into a practical form,

and enabling a much greater accuracy to be attained. The principle is

one which is occasionally employed for setting out circles with a

pocket sextant, viz., the property of a circle that the angle in a

segment is constant. The leading feature of the invention is the

arrangement of scales, which enables the operation of setting put

large curves for railway or other work to be carried out without

requiring any calculations, thereby enabling any intelligent man to

execute work which would otherwise call for a knowledge of the use of

a theodolite and the tables of tangential angles.

[Illustration: FIG. 1--PERSPECTIVE VIEW OF INSTRUMENT MOUNTED ON A

STAFF.]

The instrument is intended to be thoroughly portable; so much so,

indeed, that it is not necessary or even desirable to use a tripod. It

may be held in the hand like a sextant, or may be carried on a light

staff. The general appearance is shown in Fig. 1. It will be seen that

a metal plate, on which two scales are engraved, carries a mirror at

one end and an eye piece at the other. The mirror is mounted on a

metal plate, which is shaped to a peculiar curve. A clamp and slow

motion provide for rapid and for fine adjustment. The eye piece is set

at an angle, and contains a half silvered mirror, the upper portion

being transparent. This allows direct vision along the axis of the eye

piece, and at the same time vision in another direction, after two

reflections, one in the eye piece and the other at the adjustable

mirror. Fig. 2 is an outline plan of the instrument when closed. In

the first form of the instrument only one mirror was provided, but by

the double reflection in the improved pattern, any accidental twisting

of the rod or handle produces no displacement of the images, since the

inclination of one mirror neutralizes the equal and opposite

inclination of the other. No cross line is required with the new

arrangement, since it is only necessary that the two images should

coincide.

[Illustration: FIG. 2.--OUTLINE OF INSTRUMENT SHOWING THE PATH OF THE

DIRECT AND OF THE REFLECTED RAY.]

The dotted line A B represents the direct ray, and the line A C D the

reflected one. Fig. 3 shows the different geometrical and

trigonometrical elements of the curve, which can be read upon the

various scales, or to which the instrument may be set. An observer

standing at C sights the point B directly and the point A by

reflection. A staff being set up at each point, he will see them

simultaneously, and in coincidence if the instrument be properly set

for the curve. If any intermediate position be taken up on the curve,

both A and B will be seen in coincidence. If the two rods do not

appear superimposed, the operator must move to the right or the left

until this is the case. The instrument will then be over a point in

the curve. Any number of points at any regular or irregular distances

along the curve can thus be set out. One of the simplest elements

which can be taken as a datum is the ratio of the length of the chord

to the radius, AB/AO, Fig. 3. This being given, the value of the ratio

is found on the straight scale on the body of the instrument, and the

curved plate is moved until the beveled edge cuts the scale at the

desired point. The figure of this curve is a polar curve, whose

equation is _r_ = _a_ ± _b_ sin. 2 [theta], where _a_ is the distance

from the zero graduation to the axis of the mirror, and _b_ is the

length of the scale from zero to 2, and [theta] is the inclination of

the mirror. In the perspective view, Fig. 1, the curved edge cuts the

scale at 1. The instrument being thus set, the following elements may

be read either directly on the scales or by simple arithmetical

calculation:

[Illustration: FIG. 3]

The radius = 1.

AB, the chord, read direct on the straight scale.

AFB, the length of the arc, read direct on the back or under

surface of the plate.

FH, the versed sine, read direct on the curved scale.

ACB, the angle in the segment, read direct on the graduated

edge.

EAB, the angle between the chord and the tangent, read direct

on the graduated edge.

GAB, the tangential angle = 180 deg. - ACB.

AOB, the angle at the center = 2GAB.

AGB, the angle between the tangents = 180 deg. - AOB.

OAB, the angle between the chord and the radius = EAB - 90

deg.

AH_{2}

GF = --------- - FH.

HO

The foregoing elements are contained in a very simple diagram, Fig. 4,

which is engraved on the instrument, together with the following

references:

B = 180 deg. - A.

C = 2B.

D = 180 deg. - C.

E = A - 90.

Only one adjustment is necessary, and this is provided by means of the

screws which fix the inclination of the eyepiece. This is set at such

an angle that the instrument, when closed and reading 90° on the

divided limb, acts as an optical square.

It is not necessary, as in the ordinary method with a theodolite, that

one end of the curve should be visible from the other. If an obstacle

intervenes, all that part of the curve which commands a view of both

ends can be set out, and a ranging rod can be set up at any point of

the curve so found, and the instrument may be reset to complete the

curve.

To set out a tangent to the curve at A, Fig. 3, set up a rod at A and

another at any point C, and take up a position on the curve at some

point between them. Adjust the mirror until the rods are seen

superimposed. Then moving back to A, observe C direct, and set up a

rod at E in the line observed by reflection. Then A E is the tangent

required. Similarly, on completing the setting out of a curve, and

arriving at the end of the chord, the remote end being seen by

reflection, the direction observed along the axis of the eyepiece is

the new tangent.

Any of the angles or other ratios already mentioned may be used for

setting the instrument, but if no data whatever are given, as in the

rough surveys for colonial railways where no previous surveys exist,

it is only necessary to select points through which the curve must

pass, to set up ranging rods either at the extremities of the desired

curve, or at any points thereon, to take up a position on the desired

curve between two rods, and to adjust the instrument until they are

seen in coincidence. The curve can then be set out, and fully marked,

and the elements of the curve can be read on the scales and recorded

for reference.

[Illustration: FIG. 4.--DIAGRAM ENGRAVED ON THE INSTRUMENT.]

Various other cases which may occur in practice can be rapidly met by

one or other of the various scales. Suppose the angle A G B between

the tangents be given, together with the middle point F on the curve,

Fig. 3. Subtract this angle from 180 deg., the difference gives the

angle at the center A O B. Take half this, and set the instrument to

the angle thus found. Walk along the tangent until a rod set up at

some point in the tangent, say E, is seen in coincidence with a rod

set up at B. The position of the instrument then marks the point of

departure A. A rod being placed at A, the first half of the curve may

be set out; or, if B is invisible, the instrument may be reset for the

angle E A B, and the whole curve set out up to B. No cutting of hedges

is necessary, as with theodolite work, for a curve can easily be taken

piece by piece. Inclination of the whole instrument introduces no

appreciable error. If the eye piece be pointed up or down hill, the

instrument is thrown a little to one side or other of the tip of the

staff, but in a plane tangent to the circle. Errors made in setting

out a curve with the Trotter curve ranger are not cumulative, as in

the method of tangential angles with a theodolite. No corrections for

inaccurate hitting of the final rod can occur, for the curve must

necessarily end at that point. It should be observed that the

instrument is not intended to supersede a theodolite, but it has the

great advantage over the older instrument that no assistant or chains

or trigonometrical tables or any knowledge of mathematics are

required. The data being given, by a theodolite or otherwise, an

intelligent platelayer can easily set out the curve, while the trained

engineer proceeds in advance with the theodolite. No time is lost; as

in chaining, since the marks may be made wherever and as often as

convenient. In work where high accuracy is required this instrument is

well adapted for filling in, and where a rough idea of the nature of a

given curve is required, the mirror being adjusted for any three

points upon it, the various elements may be read off on the scales. A

telescope is provided, but the errors not being cumulative, it is

rarely required. The curve ranger weighs 1 lb. 10 oz., and is

manufactured by Messrs. Elliott Bros., St. Martin's Lane, London. It

is the invention of Mr. Alex. P. Trotter, Westminster.--_The

Engineer._

* * * * *