OPERATION AND CARE OF BOILERS

The general subject of boiler room practice may be considered from two

aspects. The first is that of the broad plant economy, with a suggestion

as to the methods to be followed in securing the best economical results

with the apparatus at hand and procurable. The second deals rather with

specific recommendations which should be followed in plant practice,

recommendations leading not only to economy but also to safety and

continuity of service. Such recommendations are dictated from an

understanding of the nature of steam generating apparatus and its

operation, as covered previously in this book.

It has already been pointed out that the attention given in recent years

to steam generating practice has come with a realization of the wide

difference existing between the results being obtained in every-day

operation and those theoretically possible. The amount of such attention

and regulation given to the steam generating end of a power plant,

however, is comparatively small in relation to that given to the balance

of the plant, but it may be safely stated that it is here that there is

the greatest assurance of a return for the attention given.

In the endeavor to increase boiler room efficiency, it is of the utmost

importance that a standard basis be set by which average results are to

be judged. With the theoretical efficiency obtainable varying so widely,

this standard cannot be placed at the highest efficiency that has been

obtained regardless of operating conditions. It is better set at the

best obtainable results for each individual plant under its conditions

of installation and daily operation.

With an individual standard so set, present practice can only be

improved by a systematic effort to approach this standard. The degree

with which operating results will approximate such a standard will be

found to be directly proportional to the amount of intelligent

supervision given the operation. For such supervision to be given, it is

necessary to have not only a full realization of what the plant can do

under the best operating conditions but also a full and complete

knowledge of what it is doing under all of the different conditions that

may arise. What the plant is doing should be made a matter of continuous

record so arranged that the results may be directly compared for any

period or set of conditions, and where such results vary from the

standard set, steps must be taken immediately to remedy the causes of

such failings. Such a record is an important check in the losses in the

plant.

As the size of the plant and the fuel consumption increase, such a check

of losses and recording of results becomes a necessity. In the larger

plants, the saving of but a fraction of one per cent in the fuel bill

represents an amount running into thousands of dollars annually, while

the expense of the proper supervision to secure such saving is small.

The methods of supervision followed in the large plants are necessarily

elaborate and complete. In the smaller plants the same methods may be

followed on a more moderate scale with a corresponding saving in fuel

and an inappreciable increase in either plant organization or expense.

There has been within the last few years a great increase in the

practicability and reliability of the various types of apparatus by

which the records of plant operation may be secured. Much of this

apparatus is ingenious and, considering the work to be done, is

remarkably accurate. From the delicate nature of some of the apparatus,

the liability to error necessitates frequent calibration but even where

the accuracy is known to be only within limits of, say, 5 per cent

either way, the records obtained are of the greatest service in

considering relative results. Some of the records desirable and the

apparatus for securing them are given below.

[Illustration: 2400 Horse-power Installation of Cross Drum Babcock &

Wilcox Boilers and Superheaters at the Westinghouse Electric and

Manufacturing Co., East Pittsburgh, Pa.]

Inasmuch as the ultimate measure of the efficiency of the boiler plant

is the cost of steam generation, the important records are those of

steam generated and fuel consumed Records of temperature, analyses,

draft and the like, serve as a check on this consumption, indicating the

distribution of the losses and affording a means of remedying conditions

where improvement is possible.

Coal Records--There are many devices on the market for conveniently

weighing the coal used. These are ordinarily accurate within close

limits, and where the size or nature of the plant warrants the

investment in such a device, its use is to be recommended. The coal

consumption should be recorded by some other method than from the

weights of coal purchased. The total weight gives no way of dividing the

consumption into periods and it will unquestionably be found to be

profitable to put into operation some scheme by which the coal is

weighed as it is used. In this way, the coal consumption, during any

specific period of the plant's operation, can be readily seen. The

simplest of such methods which may be used in small plants is the actual

weighing on scales of the fuel as it is brought into the fire room and

the recording of such weights.

Aside from the actual weight of the fuel used, it is often advisable to

keep other coal records, coal and ash analyses and the like, for the

evaporation to be expected will be dependent upon the grade of fuel used

and its calorific value, fusibility of its ash, and like factors.

The highest calorific value for unit cost is not necessarily the

indication of the best commercial results. The cost of fuel is governed

by this calorific value only when such value is modified by local

conditions of capacity, labor and commercial efficiency. One of the

important factors entering into fuel cost is the consideration of the

cost of ash handling and the maintenance of ash handling apparatus if

such be installed. The value of a fuel, regardless of its calorific

value, is to be based only on the results obtained in every-day plant

operation.

Coal and ash analyses used in connection with the amount of fuel

consumed, are a direct indication of the relation between the results

being secured and the standard of results which has been set for the

plant. The methods of such analyses have already been described. The

apparatus is simple and the degree of scientific knowledge necessary is

only such as may be readily mastered by plant operatives.

The ash content of a fuel, as indicated from a coal analysis checked

against ash weights as actually found in plant operation, acts as a

check on grate efficiency. The effect of any saving in the ashes, that

is, the permissible ash to be allowed in the fuel purchased, is

determined by the point at which the cost of handling, combined with the

falling off in the evaporation, exceeds the saving of fuel cost through

the use of poorer coal.

Water Records--Water records with the coal consumption, form the basis

for judging the economic production of steam. The methods of securing

such records are of later introduction than for coal, but great advances

have been made in the apparatus to be used. Here possibly, to a greater

extent than in any recording device, are the records of value in

determining relative evaporation, that is, an error is rather allowable

provided such an error be reasonably constant.

The apparatus for recording such evaporation is of two general classes:

Those measuring water before it is fed to the boiler and those measuring

the steam as it leaves. Of the first, the venturi meter is perhaps the

best known, though recently there has come into considerable vogue an

apparatus utilizing a weir notch for the measuring of such water. Both

methods are reasonably accurate and apparatus of this description has an

advantage over one measuring steam in that it may be calibrated much

more readily. Of the steam measuring devices, the one in most common use

is the steam flow meter. Provided the instruments are selected for a

proper flow, etc., they are of inestimable value in indicating the steam

consumption. Where such instruments are placed on the various engine

room lines, they will immediately indicate an excessive consumption for

any one of the units. With a steam flow meter placed on each boiler, it

is possible to fix relatively the amount produced by each boiler and,

considered in connection with some of the "check" records described

below, clearly indicate whether its portion of the total steam produced

is up to the standard set for the over-all boiler room efficiency.

Flue Gas Analysis--The value of a flue gas analysis as a measure of

furnace efficiency has already been indicated. There are on the market a

number of instruments by which a continuous record of the carbon dioxide

in the flue gases may be secured and in general the results so recorded

are accurate. The limitations of an analysis showing only CO_{2} and the

necessity of completing such an analysis with an Orsat, or like

apparatus, and in this way checking the automatic device, have already

been pointed out, but where such records are properly checked from time

to time and are used in conjunction with a record of flue temperatures,

the losses due to excess air or incomplete combustion and the like may

be directly compared for any period. Such records act as a means for

controlling excess air and also as a check on individual firemen.

Where the size of a plant will not warrant the purchase of an expensive

continuous CO_{2} recorder, it is advisable to make analyses of samples

for various conditions of firing and to install an apparatus whereby a

sample of flue gas covering a period of, say, eight hours, may be

obtained and such a sample afterwards analyzed.

Temperature Records--Flue gas temperatures, feed water temperatures and

steam temperatures are all taken with recording thermometers, any number

of which will, when properly calibrated, give accurate results.

A record of flue temperatures is serviceable in checking stack losses

and, in general, the cleanliness of the boiler. A record of steam

temperatures, where superheaters are used, will indicate excessive

fluctuations and lead to an investigation of their cause. Feed

temperatures are valuable in showing that the full benefit of the

exhaust steam is being derived.

Draft Regulation--As the capacity of a boiler varies with the combustion

rate and this rate with the draft, an automatic apparatus satisfactorily

varying this draft with the capacity demands on the boiler will

obviously be advantageous.

As has been pointed out, any fuel has some rate of combustion at which

the best results will be obtained. In a properly designed plant where

the load is reasonably steady, the draft necessary to secure such a rate

may be regulated automatically.

Automatic apparatus for the regulation of draft has recently reached a

stage of perfection which in the larger plants at any rate makes its

installation advisable. The installation of a draft gauge or gauges is

strongly to be recommended and a record of such drafts should be kept as

being a check on the combustion rates.

An important feature to be considered in the installing of all recording

apparatus is its location. Thermometers, draft gauges and flue gas

sampling pipes should be so located as to give as nearly as possible an

average of the conditions, the gases flowing freely over the ends of the

thermometers, couples and sampling pipes. With the location permanent,

there is no security that the samples may be considered an average but

in any event comparative results will be secured which will be useful in

plant operation. The best permanent location of apparatus will vary

considerably with the design of the boiler.

It may not be out of place to refer briefly to some of the shortcomings

found in boiler room practice, with a suggestion as to a means of

overcoming them.

1st. It is sometimes found that the operating force is not fully

acquainted with the boilers and apparatus. Probably the most general of

such shortcomings is the fixed idea in the heads of the operatives that

boilers run above their rated capacity are operating under a state of

strain and that by operating at less than their rated capacity the most

economical service is assured, whereas, by determining what a boiler

will do, it may be found that the most economical rating under the

conditions of the plant will be considerably in excess of the builder's

rating. Such ideas can be dislodged only by demonstrating to the

operatives what maximum load the boilers can carry, showing how the

economy will vary with the load and the determining of the economical

load for the individual plant in question.

2nd. Stokers. With stoker-fired boilers, it is essential that the

operators know the limitations of their stokers as determined by their

individual installation. A thorough understanding of the requirements of

efficient handling must be insisted upon. The operatives must realize

that smokeless stacks are not necessarily the indication of good

combustion for, as has been pointed out, absolute smokelessness is

oftentimes secured at an enormous loss in efficiency through excess air.

Another feature in stoker-fired plants is in the cleaning of fires. It

must be impressed upon the operatives that before the fires are cleaned

they should be put into condition for such cleaning. If this cleaning is

done at a definite time, regardless of whether the fires are in the best

condition for cleaning, there will be a great loss of good fuel with the

ashes.

3rd. It is necessary that in each individual plant there be a basis on

which to judge the cleanliness of a boiler. From the operative's

standpoint, it is probably more necessary that there be a thorough

understanding of the relation between scale and tube difficulties than

between scale and efficiency. It is, of course, impossible to keep

boilers absolutely free from scale at all times, but experience in each

individual plant determines the limit to which scale can be allowed to

form before tube difficulties will begin or a perceptible falling off in

efficiency will take place. With such a limit of scale formation fixed,

the operatives should be impressed with the danger of allowing it to be

exceeded.

4th. The operatives should be instructed as to the losses resulting from

excess air due to leaks in the setting and as to losses in efficiency

and capacity due to the by-passing of gases through the setting, that

is, not following the path of the baffles as originally installed. In

replacing tubes and in cleaning the heating surfaces, care must be taken

not to dislodge baffle brick or tile.

[Illustration: 2000 Horse-power Installation of Babcock & Wilcox

Boilers, Equipped with Babcock & Wilcox Chain Grate Stokers at the

Sunnyside Plant of the Pennsylvania Tunnel and Terminal Railroad Co.,

Long Island City, N. Y.]

5th. That an increase in the temperature of the feed reduces the amount

of work demanded from the boiler has been shown. The necessity of

keeping the feed temperature as high as the quantity of exhaust steam

will allow should be thoroughly understood. As an example of this, there

was a case brought to our attention where a large amount of exhaust

steam was wasted simply because the feed pump showed a tendency to leak

if the temperature of feed water was increased above 140 degrees. The

amount wasted was sufficient to increase the temperature to 180 degrees

but was not utilized simply because of the slight expense necessary to

overhaul the feed pump.

The highest return will be obtained when the speed of the feed pumps is

maintained reasonably constant for should the pumps run very slowly at

times, there may be a loss of the steam from other auxiliaries by

blowing off from the heaters.

6th. With a view to checking steam losses through the useless blowing of

safety valves, the operative should be made to realize the great amount

of steam that it is possible to get through a pipe of a given size.

Oftentimes the fireman feels a sense of security from objections to a

drop in steam simply because of the blowing of safety valves, not

considering the losses due to such a cause and makes no effort to check

this flow either by manipulation of dampers or regulation of fires.

The few of the numerous shortcomings outlined above, which may be found

in many plants, are almost entirely due to lack of knowledge on the part

of the operating crew as to the conditions existing in their own plants

and the better performances being secured in others. Such shortcomings

can be overcome only by the education of the operatives, the showing of

the defects of present methods, and instruction in better methods. Where

such instruction is necessary, the value of records is obvious. There is

fortunately a tendency toward the employment of a better class of labor

in the boiler room, a tendency which is becoming more and more marked as

the realization of the possible saving in this end of the plant

increases.

The second aspect of boiler room management, dealing with specific

recommendations as to the care and operation of the boilers, is dictated

largely by the nature of the apparatus. Some of the features to be

watched in considering this aspect follow.

Before placing a new boiler in service, a careful and thorough

examination should be made of the pressure parts and the setting. The

boiler as erected should correspond in its baffle openings, where

baffles are adjustable, with the prints furnished for its erection, and

such baffles should be tight. The setting should be so constructed that

the boiler is free to expand without interfering with the brickwork.

This ability to expand applies also to blow-off and other piping. After

erection all mortar and chips of brick should be cleaned from the

pressure parts. The tie rods should be set up snug and then slacked

slightly until the setting has become thoroughly warm after the first

firing. The boiler should be examined internally before starting to

insure the absence of dirt, any foreign material such as waste, and

tools. Oil and paint are sometimes found in the interior of a new boiler

and where such is the case, a quantity of soda ash should be placed

within it, the boiler filled with water to its normal level and a slow

fire started. After twelve hours of slow simmering, the fire should be

allowed to die out, the boiler cooled slowly and then opened and washed

out thoroughly. Such a proceeding will remove all oil and grease from

the interior and prevent the possibility of foaming and tube

difficulties when the boiler is placed in service.

The water column piping should be examined and known to be free and

clear. The water level, as indicated by the gauge glass, should be

checked by opening the gauge cocks.

The method of drying out a brick setting before placing a boiler in

operation is described later in the discussion of boiler settings.

A boiler should not be cut into the line with other boilers until the

pressure within it is approximately that in the steam main. The boiler

stop valve should be opened very slowly until it is fully opened. The

arrangement of piping should be such that there can be no possibility of

water collecting in a pocket between the boiler and the main, from which

it can be carried over into the steam line when a boiler is cut in.

In regular operation the safety valve and steam gauge should be checked

daily. In small plants the steam pressure should be raised sufficiently

to cause the safety valves to blow, at which time the steam gauge should

indicate the pressure at which the valve is known to be set. If it does

not, one is in error and the gauge should be compared with one of known

accuracy and any error at once rectified.

In large plants such a method of checking would result in losses too

great to be allowed. Here the gauges and valves are ordinarily checked

at the time a boiler is cut out, the valves being assured of not

sticking by daily instantaneous opening through manipulation by hand of

the valve lever. The daily blowing of the safety valve acts not only as

a check on the gauge but insures the valve against sticking.

The water column should be blown down thoroughly at least once on every

shift and the height of water indicated by the glass checked by the

gauge cocks. The bottom blow-offs should be kept tight. These should be

opened at least once daily to blow from the mud drum any sediment that

may have collected and to reduce the concentration. The amount of

blowing down and the frequency is, of course, determined by the nature

of the feed water used.

In case of low water, resulting either from carelessness or from some

unforeseen condition of operation, the essential object to be obtained

is the extinguishing of the fire in the quickest possible manner. Where

practicable, this is best accomplished by the playing of a heavy stream

of water from a hose on the fire. Another method, perhaps not so

efficient, but more generally recommended, is the covering of the fire

with wet ashes or fresh fuel. A boiler so treated should be cut out of

line after such an occurrence and a thorough inspection made to

ascertain what damage, if any, has been done before it is again placed

in service.

The efficiency and capacity depend to an extent very much greater than

is ordinarily realized upon the cleanliness of the heating surfaces,

both externally and internally, and too much stress cannot be put upon

the necessity for systematic cleaning as a regular feature in the plant

operation.

The outer surfaces of the tubes should be blown free from soot at

regular intervals, the frequency of such cleaning periods being

dependent upon the class of fuel used. The most efficient way of blowing

soot from the tubes is by means of a steam lance with which all parts of

the surfaces are reached and swept clean. There are numerous soot

blowing devices on the market which are designed to be permanently fixed

within the boiler setting. Where such devices are installed, there are

certain features that must be watched to avoid trouble. If there is any

leakage of water of condensation within the setting coming into contact

with the boiler tubes, it will tend toward corrosion, or if in contact

with the heated brickwork will cause rapid disintegration of the

setting. If the steam jets are so placed that they impinge directly

against the tubes, erosion may take place. Where such permanent soot

blowers are installed, too much care cannot be taken to guard against

these possibilities.

Internally, the tubes must be kept free from scale, the ingredients of

which a study of the chapter on the impurities of water indicates are

present in varying quantities in all feed waters. Not only has the

presence of scale a direct bearing on the efficiency and capacity to be

obtained from a boiler but its absence is an assurance against the

burning out of tubes.

In the absence of a blow-pipe action of the flames, it is impossible to

burn a metal surface where water is in intimate contact with that

surface.

In stoker-fired plants where a blast is used, and the furnace is not

properly designed, there is a danger of a blow-pipe action if the fires

are allowed to get too thin. The rapid formation of steam at such points

of localized heat may lead to the burning of the metal of the tubes.

Any formation of scale on the interior surface of a boiler keeps the

water from such a surface and increases its tendency to burn. Particles

of loose scale that may become detached will lodge at certain points in

the tubes and localize this tendency at such points. It is because of

the danger of detaching scale and causing loose flakes to be present

that the use of a boiler compound is not recommended for the removal of

scale that has already formed in a boiler. This question is covered in

the treatment of feed waters. If oil is allowed to enter a boiler, its

action is the same as that of scale in keeping the water away from the

metal surfaces.

[Illustration: Fig. 41]

It has been proven beyond a doubt that a very large percentage of tube

losses is due directly to the presence of scale which, in many

instances, has been so thin as to be considered of no moment, and the

importance of maintaining the boiler heating surfaces in a clean

condition cannot be emphasized too strongly.

The internal cleaning can best be accomplished by means of an air or

water-driven turbine, the cutter heads of which may be changed to handle

various thicknesses of scale. Fig. 41 shows a turbine cleaner with

various cutting heads, which has been found to give satisfactory

service.

Where a water-driven turbine is used, it should be connected to a pump

which will deliver at least 120 gallons per minute per cleaner at 150

pounds pressure. This pressure should never be less than 90 pounds if

satisfactory results are desired. Where an air-driven turbine is used,

the pressure should be at least 100 pounds, though 150 pounds is

preferable, and sufficient water should be introduced into the tube to

keep the cutting head cool and assist in washing down the scale as it is

chipped off.

Where scale has been allowed to accumulate to an excessive thickness,

the work of removal is difficult and tedious. Where such a heavy scale

is of sulphate formation, its removal may be assisted by filling the

boiler with water to which there has been added a quantity of soda ash,

a bucketful to each drum, starting a low fire and allowing the water to

boil for twenty-four hours with no pressure on the boiler. It should be

cooled slowly, drained, and the turbine cleaner used immediately, as the

scale will tend to harden rapidly under the action of the air.

Where oil has been allowed to get into a boiler, it should be removed

before placing the boiler in service, as described previously where

reference is made to its removal by boiling out with soda ash.

Where pitting or corrosion is noted, the parts affected should be

carefully cleaned and the interior of the drums should be painted with

white zinc if the boiler is to remain idle. The cause of such action

should be immediately ascertained and steps taken to apply the proper

remedy.

When making an internal inspection of a boiler or when cleaning the

interior heating surfaces, great care must be taken to guard against the

possibility of steam entering the boiler in question from other boilers

on the same line either through the careless opening of the boiler stop

valve or some auxiliary valve or from an open blow-off. Bad accidents

through scalding have resulted from the neglect of this precaution.

Boiler brickwork should be kept pointed up and all cracks filled. The

boiler baffles should be kept tight to prevent by-passing of any gases

through the heating surfaces.

Boilers should be taken out of service at regular intervals for cleaning

and repairs. When this is done, the boiler should be cooled slowly, and

when possible, be allowed to stand for twenty-four hours after the fire

is drawn before opening. The cooling process should not be hurried by

allowing cold air to rush through the setting as this will invariably

cause trouble with the brickwork. When a boiler is off for cleaning, a

careful examination should be made of its condition, both external and

internal, and all leaks of steam, water and air through the setting

stopped. If water is allowed to come into contact with brickwork that is

heated, rapid disintegration will take place. If water is allowed to

come into contact with the metal of the boiler when out of service,

there is a likelihood of corrosion.

If a boiler is to remain idle for some time, its deterioration may be

much more rapid than when in service. If the period for which it is to

be laid off is not to exceed three months, it may be filled with water

while out of service. The boiler should first be cleaned thoroughly,

internally and externally, all soot and ashes being removed from the

exterior of the pressure parts and any accumulation of scale removed

from the interior surfaces. It should then be filled with water, to

which five or six pails of soda ash have been added, a slow fire started

to drive the air from the boiler, the fire drawn and the boiler pumped

full. In this condition it may be kept for some time without bad

effects.

If the boiler is to be out of service for more than three months, it

should be emptied, drained and thoroughly dried after being cleaned. A

tray of quick lime should be placed in each drum, the boiler closed, the

grates covered and a quantity of quick lime placed on top of the

covering. Special care should be taken to prevent air, steam or water

leaks into the boiler or onto the pressure parts to obviate danger of

corrosion.

[Illustration: 3000 Horse-power Installation of Babcock & Wilcox Boilers

in the Main Power Plant, Chicago & Northwestern Ry. Depot, Chicago,

Ill.]