6. DURATION

The duration of tests to determine the efficiency of a hand-fired

boiler, should be 10 hours of continuous running, or such time as may be

required to burn a total of 250 pounds of coal per square foot of grate.

In the case of a boiler using a mechanical stoker, the duration, where

practicable, should be at least 24 hours. If the stoker is of a type

that permits the quantity and condition of the fuel bed at beginning and

end of the test to be accurately estimated, the duration may be reduced

to 10 hours, or such time as may be required to burn the above noted

total of 250 pounds per square foot.

In commercial tests where the service requires continuous

operation night and day, with frequent shifts of firemen, the

duration of the test, whether the boilers are hand fired or

stoker fired, should be at least 24 hours. Likewise in

commercial tests, either of a single boiler or of a plant of

several boilers, which operate regularly a certain number of

hours and during the balance of the day the fires are banked,

the duration should not be less than 24 hours.

The duration of tests to determine the maximum evaporative

capacity of a boiler, without determining the efficiency, should

not be less than 3 hours.