The coal per square foot of grate surface per hour at rating =

8624

---- = 22 pounds.

400

For 50 per cent overload the combustion rate will be approximately 60

per cent greater than this or 1.60 × 22 = 35 pounds per square foot of

grate surface per hour. The furnace draft required for the combustion

rate, from the curve, Fig. 34, is 0.6 inch. The loss in the boiler will

be 0.4 inch, in the flue 0.1 inch, and in the turns 2 × 0.05 = 0.1 inch.

The available draft required at the base of the stack is, therefore,

_Inches_

Boiler 0.4

Furnace 0.6

Flues 0.1

Turns 0.1

---

Total 1.2

Since the available draft is 80 per cent of the theoretical draft, this

draft due to the height required is 1.2 ÷ .8 = 1.5 inch.

The chimney constant for temperatures of 60 degrees Fahrenheit and 550

degrees Fahrenheit is .0071 and from formula (30),

1.5

H = ----- = 211 feet.

.0071

Its diameter from curve in Fig. 33 is 96 inches if unlined, and 102

inches inside if lined with masonry. The cross sectional area of the

flue should be approximately 70 square feet at the point where the total

amount of gas is to be handled, tapering to the boiler farthest from the

stack to a size which will depend upon the size of the boiler units

used.

Correction in Stack Sizes for Altitudes--It has ordinarily been assumed

that a stack height for altitude will be increased inversely as the

ratio of the barometric pressure at the altitude to that at sea level,

and that the stack diameter will increase inversely as the two-fifths

power of this ratio. Such a relation has been based on the assumption of

constant draft measured in inches of water at the base of the stack for

a given rate of operation of the boilers, regardless of altitude.

If the assumption be made that boilers, flues and furnace remain the

same, and further that the increased velocity of a given weight of air

passing through the furnace at a higher altitude would have no effect on

the combustion, the theory has been advanced[53] that a different law

applies.

Under the above assumptions, whenever a stack is working at its maximum

capacity at any altitude, the entire draft is utilized in overcoming the

various resistances, each of which is proportional to the square of the

velocity of the gases. Since boiler areas are fixed, all velocities may

be related to a common velocity, say, that within the stack, and all

resistances may, therefore, be expressed as proportional to the square

of the chimney velocity. The total resistance to flow, in terms of

velocity head, may be expressed in terms of weight of a column of

external air, the numerical value of such head being independent of the

barometric pressure. Likewise the draft of a stack, expressed in height

of column of external air, will be numerically independent of the

barometric pressure. It is evident, therefore, that if a given boiler

plant, with its stack operated with a fixed fuel, be transplanted from

sea level to an altitude, assuming the temperatures remain constant, the

total draft head measured in height of column of external air will be

numerically constant. The velocity of chimney gases will, therefore,

remain the same at altitude as at sea level and the weight of gases

flowing per second with a fixed velocity will be proportional to the

atmospheric density or inversely proportional to the normal barometric

pressure.

To develop a given horse power requires a constant weight of chimney gas

and air for combustion. Hence, as the altitude is increased, the density

is decreased and, for the assumptions given above, the velocity through

the furnace, the boiler passes, breeching and flues must be

correspondingly greater at altitude than at sea level. The mean

velocity, therefore, for a given boiler horse power and constant weight

of gases will be inversely proportional to the barometric pressure and

the velocity head measured in column of external air will be inversely

proportional to the square of the barometric pressure.

For stacks operating at altitude it is necessary not only to increase

the height but also the diameter, as there is an added resistance within

the stack due to the added friction from the additional height. This

frictional loss can be compensated by a suitable increase in the

diameter and when so compensated, it is evident that on the assumptions

as given, the chimney height would have to be increased at a ratio

inversely proportional to the square of the normal barometric pressure.

In designing a boiler for high altitudes, as already stated, the

assumption is usually made that a given grade of fuel will require the

same draft measured in inches of water at the boiler damper as at sea

level, and this leads to making the stack height inversely as the

barometric pressures, instead of inversely as the square of the

barometric pressures. The correct height, no doubt, falls somewhere

between the two values as larger flues are usually used at the higher

altitudes, whereas to obtain the ratio of the squares, the flues must be

the same size in each case, and again the effect of an increased

velocity of a given weight of air through the fire at a high altitude,

on the combustion, must be neglected. In making capacity tests with coal

fuel, no difference has been noted in the rates of combustion for a

given draft suction measured by a water column at high and low

altitudes, and this would make it appear that the correct height to use

is more nearly that obtained by the inverse ratio of the barometric

readings than by the inverse ratio of the squares of the barometric

readings. If the assumption is made that the value falls midway between

the two formulae, the error in using a stack figured in the ordinary way

by making the height inversely proportional to the barometric readings

would differ about 10 per cent in capacity at an altitude of 10,000

feet, which difference is well within the probable variation of the size

determined by different methods. It would, therefore, appear that ample

accuracy is obtained in all cases by simply making the height inversely

proportional to the barometric readings and increasing the diameter so

that the stacks used at high altitudes have the same frictional

resistance as those used at low altitudes, although, if desired, the

stack may be made somewhat higher at high altitudes than this rule calls

for in order to be on the safe side.

The increase of stack diameter necessary to maintain the same friction

loss is inversely as the two-fifths power of the barometric pressure.

Table 54 gives the ratio of barometric readings of various altitudes to

sea level, values for the square of this ratio and values of the

two-fifths power of this ratio.