TABLE 52

TEMPERATURE OF WASTE GASES FROM

VARIOUS INDUSTRIAL PROCESSES

+-----------------------------------------------------+

|+-----------------------------------+---------------+|

||Waste Heat From |Temperature[50]||

|| | Degrees ||

|+-----------------------------------+---------------+|

||Brick Kilns | 2000-2300 ||

||Zinc Furnaces | 2000-2300 ||

||Copper Matte Reverberatory Furnaces| 2000-2200 ||

||Beehive Coke Ovens | 1800-2000 ||

||Cement Kilns | 1200-1600[51]||

||Nickel Refining Furnaces | 1500-1750 ||

||Open Hearth Steel Furnaces | 1100-1400 ||

|+-----------------------------------+---------------+|

+-----------------------------------------------------+

The power that can be obtained from waste gases depends upon their

temperature and weight, and both of these factors vary widely in

different commercial operations. Table 52 gives a list of certain

processes yielding waste gases the heat of which is available for the

generation of steam and the approximate temperature of such gases. It

should be understood that the temperatures in the table are the average

of the range of a complete cycle of the operation and that the minimum

and maximum temperatures may vary largely from the figures given.

The maximum available horse power that may be secured from such gases is

represented by the formula:

W(T-t)s

H. P. = ------- (23)

33,479

Where W = the weight of gases passing per hour,

T = temperature of gases entering heating surface,

t = temperature leaving heating surface,

s = specific heat of gases.

The initial temperature and the weight or volume of gas will depend, as

stated, upon the process involved. The exit temperature will depend, to

a certain extent, upon the temperature of the entering gases, but will

be governed mainly by the efficiency of the heating surfaces installed

for the absorption of the heat.

Where the temperature of the gas available is high, approaching that

found in direct fired boiler practice, the problem is simple and the

question of design of boiler becomes one of adapting the proper amount

of heating surface to the volume of gas to be handled. With such

temperatures, and a volume of gas available approximately in accordance

with that found in direct fired boiler practice, a standard boiler or

one but slightly modified from the standard will serve the purpose

satisfactorily. As the temperatures become lower, however, the problem

is more difficult and the departure from standard practice more radical.

With low temperature gases, to obtain a heat transfer rate at all

comparable with that found in ordinary boiler practice, the lack of

temperature must be offset by an added velocity of the gases in their

passage over the heating surfaces. In securing the velocity necessary to

give a heat transfer rate with low temperature gases sufficient to make

the installation of waste heat boilers show a reasonable return on the

investment, the frictional resistance to the gases through the boiler

becomes greatly in excess of what would be considered good practice in

direct fired boilers. Practically all operations yielding waste gases

require that nothing be done in the way of impairing the draft at the

furnace outlet, as this might interfere with the operation of the

primary furnace. The installation of a waste heat boiler, therefore,

very frequently necessitates providing sufficient mechanical draft to

overcome the frictional resistance of the gases through the heating

surfaces and still leave ample draft available to meet the maximum

requirements of the primary furnace.

Where the temperature and volume of the gases are in line with what are

found in ordinary direct fired practice, the area of the gas passages

may be practically standard. With the volume of gas known, the draft

loss through the heating surfaces may be obtained from experimental data

and this additional draft requirement met by the installation of a stack

sufficient to take care of this draft loss and still leave draft enough

for operating the furnace at its maximum capacity.

Where the temperatures are low, the added frictional resistance will

ordinarily be too great to allow the draft required to be secured by

additional stack height and the installation of a fan is necessary. Such

a fan should be capable of handling the maximum volume of gas that the

furnace may produce, and of maintaining a suction equivalent to the

maximum frictional resistance of such volume through the boiler plus the

maximum draft requirement at the furnace outlet. Stacks and fans for

this class of work should be figured on the safe side. Where a fan

installation is necessary, the loss of draft in the fan connections

should be considered, and in figuring conservatively it should be

remembered that a fan of ample size may be run as economically as a

smaller fan, whereas the smaller fan, if overloaded, is operated with a

large loss in efficiency. In practically any installation where low

temperature gas requires a fan to give the proper heat transfer from the

gases, the cost of the fan and of the energy to drive it will be more

than offset by the added power from the boiler secured by its use.

Furthermore, the installation of such a fan will frequently increase the

capacity of the industrial furnace, in connection with which the waste

heat boilers are installed.

In proportioning heating surfaces and gas passages for waste heat work

there are so many factors bearing directly on what constitutes the

proper installation that it is impossible to set any fixed rules. Each

individual installation must be considered by itself as well as the

particular characteristics of the gases available, such as their

temperature and volume, and the presence of dust or tar-like substances,

and all must be given the proper weight in the determination of the

design of the heating surfaces and gas passages for the specific set of

conditions.

[Graph: Per Cent of Water Heating Surface passed over by Gases/Per Cent

of the Total Amount of Steam Generated in the Boiler

against Temperature in Degrees Fahrenheit of Hot Gases Sweeping Heating

Surface

Fig. 31. Curve Showing Relation Between Gas Temperature, Heating Surface

passed over, and Amount of Steam Generated. Ten Square Feet of Heating

Surface are Assumed as Equivalent to One Boiler Horse Power]

Fig. 31 shows the relation of gas temperatures, heating surface passed

over and work done by such surface for use in cases where the

temperatures approach those found in direct fired practice and where the

volume of gas available is approximately that with which one horse power

may be developed on 10 square feet of heating surface. The curve assumes

what may be considered standard gas passage areas, and further, that

there is no heat absorbed by direct radiation from the fire.

Experiments have shown that this curve is very nearly correct for the

conditions assumed. Such being the case, its application in waste heat

work is clear. Decreasing or increasing the velocity of the gases over

the heating surfaces from what might be considered normal direct fired

practice, that is, decreasing or increasing the frictional loss through

the boiler will increase or decrease the amount of heating surface

necessary to develop one boiler horse power. The application of Fig. 31

to such use may best be seen by an example:

Assume the entering gas temperatures to be 1470 degrees and that the

gases are cooled to 570 degrees. From the curve, under what are assumed

to be standard conditions, the gases have passed over 19 per cent of

the heating surface by the time they have been cooled 1470 degrees.

When cooled to 570 degrees, 78 per cent of the heating surface has been

passed over. The work done in relation to the standard of the curve is

represented by (1470 - 570) ÷ (2500 - 500) = 45 per cent. (These

figures may also be read from the curve in terms of the per cent of the

work done by different parts of the heating surfaces.) That is, 78 per

cent - 19 per cent = 59 per cent of the standard heating surface has

done 45 per cent of the standard amount of work. 59 ÷ 45 = 1.31, which

is the ratio of surface of the assumed case to the standard case of the

curve. Expressed differently, there will be required 13.1 square feet

of heating surface in the assumed case to develop a horse power as

against 10 square feet in the standard case.

The gases available for this class of work are almost invariably very

dirty. It is essential for the successful operation of waste-heat

boilers that ample provision be made for cleaning by the installation of

access doors through which all parts of the setting may be reached. In

many instances, such as waste-heat boilers set in connection with cement

kilns, settling chambers are provided for the dust before the gases

reach the boiler.

By-passes for the gases should in all cases be provided to enable the

boiler to be shut down for cleaning and repairs without interfering with

the operation of the primary furnace. All connections from furnace to

boilers should be kept tight to prevent the infiltration of air, with

the consequent lowering of gas temperatures.

Auxiliary gas or coal fired grates must be installed to insure

continuity in the operation of the boiler where the operation of the

furnace is intermittent or where it may be desired to run the boiler

with the primary furnace not in operation. Such grates are sometimes

used continuously where the gases available are not sufficient to

develop the required horse power from a given amount of heating surface.

Fear has at times been expressed that certain waste gases, such as those

containing sulphur fumes, will have a deleterious action on the heating

surface of the boiler. This feature has been carefully watched, however,

and from plants in operation it would appear that in the absence of

water or steam leaks within the setting, there is no such harmful

action.

[Illustration: Fig. 32. Babcock & Wilcox Boiler Arranged for Utilizing

Waste Heat from Open Hearth Furnace. This Setting may be Modified to

Take Care of Practically any Kind of Waste Gas]