TYPICAL ANALYSES OF BLAST FURNACE GAS

+----------------------------------------------------------------+

|+-----------------------+------+----+-----+----+------+--------+|

|| |CO_{2}| O | CO | H |CH_{4}| N ||

|+-----------------------+------+----+-----+----+------+--------+|

||Bessemer Furnace | 9.85|0.36|32.73|3.14| .. |53.92 ||

||Bessemer Furnace | 11.4 | .. |27.7 |1.9 | 0.3 |58.7 ||

||Bessemer Furnace | 10.0 | .. |26.2 |3.1 | 0.2 |60.5 ||

||Bessemer Furnace | 9.1 | .. |28.7 |2.7 | 0.2 |59.3 ||

||Bessemer Furnace | 13.5 | .. |25.2 |1.43| .. |59.87 ||

||Bessemer Furnace[47] | 10.9 | .. |27.8 |2.8 | 0.2 |58.3 ||

||Ferro Manganese Furnace| 7.1 | .. |30.1 | .. | .. |62.8[48]||

||Basic Ore Furnace | 16.0 |0.2 |23.6 | .. | .. |60.2[48]||

|+-----------------------+------+----+-----+----+------+--------+|

+----------------------------------------------------------------+

Until recently, the important consideration in the burning of blast

furnace gas has been the capacity that can be developed with practically

no attention given to the aspect of efficiency. This phase of the

question is now drawing attention and furnaces especially designed for

good efficiency with this class of fuel are demanded. The essential

feature is ample combustion space, in which the combustion of gases may

be practically completed before striking the heating surfaces. The gases

have the power of burning out completely after striking the heating

surfaces, provided the initial temperature is sufficiently high, but

where the combustion is completed before such time, the results secured

are more satisfactory. A furnace volume of approximately 1 to 1.5 cubic

feet per rated boiler horse power will give a combustion space that is

ample.

Where there is the possibility of a failure of the gas supply, or where

steam is required when the blast furnace is shut down, coal fired grates

of sufficient size to get the required capacity should be installed.

Where grates of full size are not required, ignition grates should be

installed, which need be only large enough to carry a fire for igniting

the gas or for generating a small quantity of steam when the blast

furnace is shut down. The area of such grates has no direct bearing on

the size of the boiler. The grates may be placed directly under the gas

burners in a standard position or may be placed between two bridge walls

back of the gas furnace and fired from the side of the boiler. An

advantage is claimed for the standard grate position that it minimizes

the danger of explosion on the re-ignition of gas after a temporary

stoppage of the supply and also that a considerable amount of dirt, of

which there is a good deal with this class of fuel and which is

difficult to remove, deposits on the fire and is taken out when the

fires are cleaned. In any event, regardless of the location of the

grates, ample provision should be made for removing this dust, not only

from the furnace but from the setting as a whole.

Blast furnace gas burners are of two general types: Those in which the

air for combustion is admitted around the burner proper, and those in

which this air is admitted through the burner. Whatever the design of

burner, provision should be made for the regulation of both the air and

the gas supply independently. A gas opening of .8 square inch per rated

horse power will enable a boiler to develop its nominal rating with a

gas pressure in the main of about 2 inches. This pressure is ordinarily

from 6 to 8 inches and in this way openings of the above size will be

good for ordinary overloads. The air openings should be from .75 to .85

square inch per rated horse power. Good results are secured by inclining

the gas burners slightly downward toward the rear of the furnace. Where

the burners are introduced over coal fired grates, they should be set

high enough to give headroom for hand firing.

Ordinarily, individual stacks of 130 feet high with diameters as given

in Kent's table for corresponding horse power are large enough for this

class of work. Such a stack will give a draft sufficient to allow a

boiler to be operated at 175 per cent of its rated capacity, and beyond

this point the capacity will not increase proportionately with the

draft. When more than one boiler is connected with a stack, the draft

available at the damper should be equivalent to that which an individual

stack of 130 feet high would give. The draft from such a stack is

necessary to maintain a suction under all conditions throughout all

parts of the setting. If the draft is increased above that which such a

stack will give, difficulties arise from excess air for combustion with

consequent loss in efficiency.

A poor mixing or laneing action in the furnace may result in a pulsating

effect of the gases in the setting. This action may at times be remedied

by admitting more air to the furnace. On account of the possibility of a

pulsating action of the gases under certain conditions and the puffs or

explosions, settings for this class of work should be carefully

constructed and thoroughly buckstayed and tied.

Natural Gas--Natural gas from different localities varies considerably

in composition and heating value. In Table 50 there is given a number of

analyses and heat values for natural gas from various localities.

This fuel is used for steam generating purposes to a considerable extent

in some localities, though such use is apparently decreasing. It is best

burned by employing a large number of small burners, each being capable

of handling 30 nominal rated horse power. The use of a large number of

burners obviates the danger of any laneing or blowpipe action, which

might be present where large burners are used. Ordinarily, such a gas,

as it enters the burners, is under a pressure of about 8 ounces. For the

purpose of comparison, all observations should be based on gas reduced

to the standard conditions of temperature and pressure, namely 32

degrees Fahrenheit and 14.7 pounds per square inch. When the temperature

and pressure corresponding to meter readings are known, the volume of

gas under standard conditions may be obtained by multiplying the meter

readings in cubic feet by 33.54 P/T, in which P equals the absolute

pressure in pounds per square inch and T equals the absolute temperature

of the gas at the meter. In boiler testing work, the evaporation should

always be reduced to that per cubic foot of gas under standard

conditions.