49. TEST OF THE INTERNAL FRICTION.

_a._ This is shown by the reading of steam gauge compared with water

pressure gauge at air chamber.

Tests have generally run about as follows, for pumps running at full

rated speed:

===============+=========+=========+=========+=============

Size Gallons | 500 | 750 | 1,000 | 1,500

Per Minute | | | |

Capacity. | | | |

---------------+---------+---------+---------+-------------

Ratio of Steam |=4= Times|=3= Times|=3= Times|=2-3/4= Times

Piston Area to | | | |

Water Piston | | | |

Area. | | | |

---------------+---------+---------+---------+-------------

Water | 100 | 100 | 100 | 100

Pressure | | | |

lbs. Per | | | |

Sq. in. | | | |

---------------+---------+---------+---------+-------------

Steam Pressure | 25 | 33 | 33 | 36·5

Theoretically | | | |

Necessary, | | | |

Disregarding | | | |

Friction. | | | |

---------------+---------+---------+---------+-------------

Excess of Steam| 15 | 12 | 12 | 13·5

Pressure Needed| | | |

to Overcome | | | |

Friction, Back | | | |

Pressure, Etc. | | | |

---------------+---------+---------+---------+-------------

Actual Steam | 40 | 45 | 45 | 50

Pressure Found | | | |

Necessary at | | | |

the Pump. | | | |

---------------+---------+---------+---------+-------------

_b._ The steam pressure needed will vary slightly with the freedom of

the exhaust pipe and with the tightness of the packings, etc., but a

steam pressure of 45 pounds at the steam chest should suffice for 100

pounds water pressure on pump in proper adjustment.