A CURRENT METER.

We give a description of a meter we made in June, 1883. You will find

a cross section of the meter and also a printed dial we had made at

the time. We called it an ampere register, but no doubt we would give

it a better name to-day. The meter consisted of a glass tube, _c_,

both ends of which were fitted into two bent pieces of piping, D and

F, as shown. Through these bent tubes, D and F, passed the wires, a

and _b_, which were connected to the binding posts, A and B. The part

of the wire where it passed into the tubes was well insulated. At the

ends, _a'_ and _b'_, was connected the coil, R, which consisted simply

of a few turns of copper wire whose diameter was less than the leading

wires, _a_ and _b_. To the tube, D, was attached a square tube, E,

which had a little opening at the top so as to permit a small

undershot wheel, I, to revolve freely. This undershot wheel was well

pivoted and constructed very light. To the axis of this wheel was

connected another system of wheels with indicators, as shown, J. Now

the tubes, E and F, were connected to a reservoir, G. This reservoir

consisted of a square tank, in the inside of which were soldered in an

alternating manner square sheets of copper as shown in the drawing,

_g_ _g'_ _g''_ _g'''_ ... These sheets acted as diffusers. These

plates or sheets presented a very large surface. On the outside of the

tank, G, were also diffusers, _h_ _h'_ ... arranged all round and

presenting an appearance as if two books were open so as to form a

square with their covers, the leaves being the diffusers. The

diffusers on the outside were at right angles to those inside.

[Illustration: CROSS SECTION OF JEHL AND RUPP'S CURRENT METER.]

The action of the meter was thus: When a current passes through the

coil, R, it heats the liquid at the place, thus causing a circulation,

the warm liquid ascending while the cold liquid descends as shown by

the arrows. This circulation causes the undershot wheel to revolve,

and its revolutions are registered by the clockwork. The stronger the

current, the more the heat, and thus the more rapid the circulation.

The warm liquid once in the tank, which is of a reasonable size, will

impart its heat to all the diffusers. The surface of the glass tube,

etc., is very small in comparison to the surface of the tank. It will

be seen that the function of this apparatus is independent of the

outward temperature, for the motion of the liquid is due only to that

heat which is generated by the current. When the current does not

pass, it is evident that the liquid, at whatever temperature it may

be, does not circulate, as all parts are of the same temperature; but

the moment the current passes, a difference is produced, which causes

a circulation in proportion to the current. We may mention that we

tried various liquids, and give preference to pure olive oil. It will

also be seen that this meter is good for alternating currents. In

conclusion, we may remark that the tests we made gave satisfaction,

and we wanted to publish them, but that Mr. Jehl was called away to

fit up the Edison exhibit in the Vienna exhibition for the Societe

Electrique Edison of Paris. After the exhibition we began our work

upon our disk machine, and had almost forgotten our meter. The whole

apparatus is mounted on a base, K.

[Illustration: DIAL FACE.]

JEHL AND RUPP.

Brünn, Sept. 26, 1887.

* * * * *