DIRECTIONS FOR SETTING UP AND RUNNING.

Before connecting the steam pipes, blow out with steam pressure the

chips and dirt in the steam pipes. Always use the union furnished with

the pump. It has a gauze gasket in it to catch the dirt that may get

into the valve. Before starting pump, open air cock in delivery pipe

and turn exhaust lever back, away from the air chamber. Then open

throttle valve wide and allow pump to exhaust into the air until it

takes suction, when deflecting lever may be thrown forward toward air

chamber and cold water in the pump will condense the exhaust and return

it to the boiler.

If pump refuses to work, the difficulty is to be looked for in the

valve chest. Do not take off the chest. The valve may be taken out and

cleaned but _never_ filed. _The valve must be returned through same end

as taken from._ Before closing, be sure that the head is screwed tight

on the valve, using the socket wrench furnished.

When the pump is stopped, pull the exhaust lever back, so the condensed

steam from leak of throttle valve will not go into the pump. It is

safer also in cold weather to take off head of water end. Slight but

constant lubrication adds much to the regular working of the pump.

Be sure there are no leaks in the suction pipe, and when water is

raised more than 10 feet, a foot valve should be put in. Compress the

packings on piston rod as little as possible and yet prevent the escape

of steam. Before leaving the pump in cold weather, break the suction

and allow it to run empty for a minute with all the cocks open, then

be sure the throttle valve is closed tight. When necessary, pack the

joints under the steam chest, side plate and air chamber with manilla

paper or thin rubber.