CHAPTER XXV

X-RAYS IN PODIATRY

Roentgenology is the science that deals with the use of the Roentgen,

or X-rays, in all their applications. The subject is divided into

three parts, each distinct from the other, and with special required

study for each part. The first branch of roentgenology is known as

_roentgenotherapy_ or _actinotherapy_, and comprehends the treatment of

disease by the use of the X-rays or by other radiant energy.

Roentgenotherapy, to be intelligently applied by the practitioner,

requires a thorough knowledge of pathology and is strictly within

the province of the licensed doctor of medicine. The second branch

variously styled _fluoroscopy_, _skiascopy_, _radioscopy_ or

_roentgenoscopy_, is utilized for examining the various parts of

the body by projecting the X-rays through the body and fixating

the shadows cast on the fluoroscope. This branch of the science of

light is of great assistance in diagnosis and is used extensively in

surgery for the location of foreign bodies in the tissues. The third

division of roentgenology is called _radiography_, _skiagraphy_ or

_roentgenography_, and consists of the making of X-ray photographs by

passing the ray through the body in front of a photographic plate.

This branch is of great importance to the podiatrist because of the

value it possesses in the diagnosis of foot lesions, involving the bony

structures; it often clears up a doubt as to the true state of a lesion

when other means have failed. The soft tissues through which the ray

passes readily appear in light shadow, while the bones, because they

are solid, cast a darker shadow on the plate.

Experiments with electricity and with the modifications of the various

currents of electricity, have been responsible for all of the new

discoveries and inventions along these lines, and the same may be said

of the X-rays.

The two divisions of electric current are the direct and the

alternating, named after the direction in which they flow. The direct

current moves in one direction and may be likened to the flow of water

from a faucet, while the alternating current does not maintain a

steady pressure nor does it flow in the same direction continuously.

The alternating current, which is commonly used for lighting purposes,

reverses its direction of flow and pressure 120 times per second. It is

therefore called 60 cycle current, in that it makes 60 complete cycles

per second. The alternating current may be likened to the tide, which

rises and falls every twelve hours. Instead of passing from ebb to

flood and back again each twelve hours, the alternating current, used

for illuminating purposes, does so in one-sixtieth of a second.

The alternating current, is of most value to the sciences, because its

voltage or pressure may be easily changed. Thus it can be raised or

lowered by passing it through special apparatus. One particular form

of alternating current has a voltage of from 30,000 to 120,000 and can

be used for the production of Roentgen rays, if it be transformed into

a so-called pulsative or unidirectional high tension current. This

transformation is easily brought about by modern Roentgen ray apparatus.

The discovery of the X-rays was preceded by an improvement in the

knowledge of alternating currents. Many scientists were experimenting

and looking for new rays and currents, and after the invention of the

air pump and the production of glass globes, from which the air was

removed by means of the pump, Geissler invented the process of sealing

platinum into glass and produced the Geissler air pump, which is used

to the present day. This made it possible to seal electric conductors

into vacuum tubes.

Following this, Faraday and Maxwell developed the electro-magnetic

theory of light and laid the foundation for a theory of the Roentgen

ray, which, although later considerably changed, has proven one of the

most useful adjuvants to the science of physics. The period between

1840 and the discovery of the X-rays was an active one in electric

experimenting. Many men were interested in this work, and their

observations and discoveries were important in the final discovery of

the rays. In fact, Roentgen’s discovery was fully expected, inasmuch

as several investigators, including Sir William Crookes and Roentgen

himself, were convinced that rays existed of which they knew nothing.

The earlier of the two workers, Crookes, had probably produced X-rays,

but overlooked them and it fell to Roentgen to become aware of the

conditions under which they were produced. He called them X-rays or

unknown rays, but after a time, they were named after him, and are

known in science as Roentgen rays. Roentgen wrote and published three

papers on the subject and these have become classics on this topic. All

of the facts announced by him at that time continue to be accepted,

because, notwithstanding all the work done along these lines, they have

never been disproven.

Experiments have been continuous, and gradually the types of generators

and tubes have changed, always improving. Where at first only simple

work could be accomplished, the most wonderful things in this art are

now being done, with probably many more wonderful things still to

come. The dangers to which the earlier workers were subjected have

been gradually eliminated, and today with proper care, the danger from

the X-rays has been reduced to a minor factor. This danger came about

from lack of knowledge of what occurred in the tube when the ray was

being generated. There are three rays produced, one of which causes

destruction of the human tissues, when exposed for a prolonged period

of time. By preventing the passage of this ray, by the use of lead and

lead glass, as protective mediums, the danger has been practically

controlled.

X-RAY APPARATUS

The apparatus used in the generation of the X-rays consists of a

generator, a vacuum tube and an appliance for holding the tube in a

fixed position, called the tube stand.

=The Generator.= The generators used in X-ray work are of three types,

the motor generator, the interrupterless type and the coil generator

with a chemical interrupter.

The function of the Roentgen ray apparatus is to produce high potential

electric discharges in one and the same direction, or what is known

as a unidirectional current. Dependent upon the kind of current used

to start with, distinction can be made between the types of apparatus

previously mentioned. These types are operated by either direct or

alternating current.

Direct current apparatus requires an interrupting device for the

purpose of producing the necessary change of flux of magnetic lines in

the inductive part of the apparatus. Interrupting devices, which are

used in connection with such apparatus, are of three kinds: _first_,

the hammer interrupter; _second_, the mercury interrupter; _third_, the

electrolytic interrupter. The function of any one of these interrupters

is to break up the continuous flow of direct current into small

fragments. Each one of these fragments then produces one impulse of

high potentiality, which is then directed through the tube.

The alternating current, as its name implies, is already interrupted,

but the impulses are alternately changing direction, passing first

in one direction and then in the opposite direction. Hence, if the

alternating current is used as a primary source of electric energy,

then the secondary or high potential impulses will also be changing

their direction alternately. Two methods are used in employing the

alternating current as a primary source of energy. The first consists

of the suppression of one phase (that which would pass in the negative

direction) by means of the so-called rectifier cell. The second

consists of producing high potential impulses which flow in alternate

directions, and to then redirect these impulses so that all of those

passing through the tube are in the one and the same direction.

[Illustration: INTERRUPTERLESS TYPE GENERATOR]

Accordingly, X-ray apparatus can be divided into the three classes

previously mentioned. The coil, consisting of an induction coil

activated by direct current, which is broken into small sections by

the interrupter; or the induction coil which is energized by the

alternating current of which one phase is suppressed through a liquid

rectifier cell, and in which the proper interruptions are again

produced by some interrupting device. The most extensively used type

of apparatus is known as the “interrupterless machine.” This machine

operates on either the direct or the alternating current, but, if

the direct current is used as a primary source, it is transformed

into an alternating current by means of a rotary converter or motor

generator set. The alternating current, therefore, either produced or

already available, passes into the primary coil of a transformer which

changes it into alternating impulses of high potentiality. In order

to transform them into impulses, all of which shall pass in the same

direction, a so-called rectifying system is employed. This consists

of either a disk or of cross-sticks, which are so arranged that they

produce contact with both terminals of the transformer in such a way

that current of the same polarity, the unidirectional current, is

always delivered to the tube. The name “interrupterless machine” merely

implies that the devices used for interrupting the primary current have

been eliminated.

There is one other type of apparatus which is built on the principle of

an electrically oscillating system. Here again a start is made with the

alternating current, obtained either from the line or by changing the

direct current by means of an interrupter. The current is transformed

through a so-called step-up transformer into one of high potentiality

which is then still alternating. This current oscillates over a spark

gap. Parallel to this spark gap a resonator is connected in which

impulses are produced that correspond to the discharges over the gap

and which, if applied to a specially built, so-called high frequency

Roentgen ray tube, will produce X-rays. Since the principle of electric

oscillations of a high frequency is used in this type of apparatus, it

is generally called the high frequency Roentgen ray apparatus.

[Illustration: TUNGSTEN TARGET TUBE]

=Roentgen Ray Tubes.= The various types of apparatus previously

described require special forms of Roentgen ray tubes. For the coils

by virtue of their relatively small capacity, platinum target tubes

are generally employed. The capacity of the interrupterless type being

considerably higher, the use of a material of greater resistance as

a target is necessitated. For this purpose tungsten is generally

employed. For the high frequency, or Tesla coils, a tube which embodies

a rectifying or valve action device is necessary.

The mechanism of the production of Roentgen rays can be described

in the following way: the cathode, or negative terminal of the

tube, consists of a hollow spherical surface of aluminum. When this

electrode is attached to a negative potential, a stream of negative

ions or cathode rays is projected perpendicular to the surface of

the electrode. By reason of its curvature, the electrode is therefore

focused to produce a converging beam of cathode rays, the area of which

is smallest where, in the centre of the tube, the tungsten block or

anticathode is placed.

According to whether the area selected for the location of the

anticathode is small or large, the possibility to distinguish between

fine, medium or broad focused tubes arises. The discharge from the

negative electrode takes place, dependent upon conditions which give

to the discharge either a high or a low velocity. If the velocity is

high, the change from kinetic energy to Roentgen ray energy will be

greater than if the velocity of the cathode ray stream is decreased.

In the latter case, the radiations will have less penetrating power.

The velocity of the discharge must therefore depend upon the magnitude

of the charge on the negative electrode, and also upon the number of

gas particles present in the tube at that time. If there is a large

quantity of gas present, there will be a reduction in the speed of the

ray, due to collision and impact with the gas. The penetration of the

Roentgen rays depends therefore directly upon the potential produced

by the apparatus and inversely on the gas pressure (or directly on the

vacuum) of the tube.

For the purpose of controlling the state of vacuum in the tube, a

regulating system has been improvised which, when an electric current

is passed through it, liberates a certain amount of gas which passes

into the tube proper. This is a convenient device for reducing the

vacuum of the tube. Up to the present time, no one has succeeded in

inventing an efficient method or device for removing gas from the tube,

or a means which would help to increase the vacuum. It is for that

reason that operators should guard against reducing the tube unduly.

It is a simple matter to reduce the vacuum but difficult to increase

it. When a tube becomes low (when the gas content is high), resting the

tube by allowing it to remain in its bracket for a period of time,

will usually suffice to increase the vacuum.

The proper care of the tube is essential for good radiograms. It should

be kept free from dust, and before being used the degree of vacuum

should be determined by the testing apparatus on the generator. If

the tube is dusty or dirty, the passage of the rays through the glass

will be hampered, as these particles tend to deflect the rays from

their straight course. If the vacuum of the tube is too high, it will

affect the quality of the plate, and if it is too low there will be no

penetration and therefore a blank plate.

[Illustration: TUBE STAND]

=The Tube Stand.= The tubes used in Roentgenology are delicate

structures and great care must be exercised so as to prevent breakage.

To guard against such damage it is necessary to securely hold the tube

in a proper device while it is being used. The tube stand should be

so arranged that it is possible to raise or lower the tube, with its

connections, without being compelled to touch the tube itself, to swing

it from side to side, to tilt it forward or backward, or in or out.

This is best accomplished by the modern tube stand which is so arranged

that after having set the tube in its proper place, it is no longer

necessary to touch the apparatus in order to secure all of the above

named motions. A careful study of the accompanying photograph will make

this clear.

=The Roentgen or X-rays.= The rays generated in the apparatus

heretofore described, and named after their discoverer, are of a

peculiar character, and although they have proven a boon to mankind,

serious trouble and even death has come to those who in their ignorance

used the X-rays promiscuously. It has been discovered that there are

three distinct rays generated when the high potential current is passed

through the vacuum tube and they have been named after the first three

letters of the Greek alphabet, namely: the alpha, the beta and the

gamma rays. The _alpha_ ray is the ray that is seen in the tube and is

of no consequence. The _beta_ and _gamma_ rays are invisible and it is

these rays that penetrate the tissues of the body. To the gamma ray

is attributed the harmful effects of Roentgen’s discovery. Although

the X-ray is used as a therapeutic measure it should only be applied

by those who have a thorough knowledge of its properties. Prolonged

exposure will cause severe burns, and in some cases continued contact

with the ray has caused cancer. Their action in this respect is due

to the actinic quality of the gamma rays. The symptoms of a burn do

not manifest themselves until a minimum of a week or ten days after

exposure and, when they do appear, they are usually severe. Sloughing

of the tissues takes place, and the wounds produced do not heal readily

and, in consequence, ugly disfiguring scars remain.

=Radiography.= This branch of Roentgenology is of most interest to the

podiatrist. By means of photographic plates, properly exposed and well

developed, it is often possible to make diagnoses where other means

have failed. It is essential for one who would be correct in diagnosing

X-ray plates, to have a thorough knowledge of the structure of the

bones of the foot and to understand the meaning of the various shadows

cast upon the plate.

When the X-rays penetrate the foot they pass through the tissues, and

when they strike a tissue of great density they cannot penetrate it

as readily as the rays passing through a tissue of less density. The

result is that as the rays pass through the foot they cast a series of

shadows on the sensitized photographic plate beneath, the density of

which depends upon the tissues through which the rays have passed. So,

in reality, the plate when finished is not a photograph, as most laymen

imagine, but a shadowgraph or, as it is variously termed, a radiogram

or skiagram.

For the purposes of producing radiographs that are clear and easily

interpreted, it is necessary to have good materials and to follow

the technic of developing and fixing the plate in every detail. The

photographic plates used in general photography do not, as a rule,

give satisfactory results. Plates, with specially prepared emulsions

that are adapted for radiography, are preferred. These plates are

sensitized with a gelatinous substance containing bromide of silver.

When this substance is exposed to the action of the rays it undergoes

chemical decomposition, the degree of which varies with the amount of

exposure. It is upon this decomposition of the salt that the art of

photography depends and so, too, the science of radiography. The plate

is then developed.

Developing of a photographic plate consists of making visible the

metallic silver which is produced by the decomposition of the silver

bromide. This is accomplished by the use of a mixture of chemicals

called the developer. The plate is put into a tray about two inches

deep and large enough to allow for its easy removal, and the developing

solution is poured over the emulsion. Gradually the exposed portions of

the negative will appear and developing must continue until every such

exposed part has been brought out in its fullest detail. The unexposed

portions are then dissolved by placing the plate in a solution of

sodium hyposulphite, sometimes called the _fixer_ or the fixing bath.

As its name implies, this solution permanently fixes the exposed

silver, and if the plate were not treated in this manner the entire

mass would become blackened upon exposure to light.

The preparation of radiographic plates is carried on in a room that

is protected from light with the exception of a dull, red glow from a

“ruby lamp” which has no effect upon the plate. The plate is placed

into an envelope made of black paper, and this in turn is placed, flap

down, into a second envelope of red paper. This insures protection

from light rays when the plate is brought out of the dark room. After

exposure, the negative must be taken back to the dark room before it is

removed from the envelope. After it has been developed and fixed it may

be brought into the light with safety.

The length of time required in making exposures varies with the

different types of apparatus. When the flow of rays is great, it will

require a proportionately shorter exposure. So, too, the length of

exposure with a certain type of generator varies with the part being

exposed. The bones of the fingers would require less time than those

of the leg, while the bones of the head would require more time than

either of the above for the production of a clear radiograph. It is

essential in all branches of radiography to remember that the part to

be skiagraphed be parallel to and in close proximity to the plate. This

will prevent elongations and foreshortenings of the shadows cast.

[Illustration: SPUR ON THE UNDER SURFACE OF THE HEEL]

DIAGNOSIS OF RADIOGRAPHS

There are several lesions of the foot commonly arising in the practice

of the podiatrist, which are easily recognized by radiographic

examination but which otherwise are difficult of diagnosis. Some of

these cases are shown in the accompanying pictures, which were selected

from a large collection at The First Institute of Podiatry of New

York City. They are characteristic of the lesions they depict, and

it is needless to emphasize their value as an aid to diagnosis. If a

condition involves the bony structure of the foot, clinical symptoms

are never so certain that an absolutely positive diagnosis can be made,

but the X-ray plate readily reveals such disturbances so that there is

no doubt left in the minds of the practitioner as to the exact nature

of the trouble. Periostitis, exostosis, fractures, arthritis, bone

abscesses, bone ulcers, etc., are thus easily distinguished.

=Periostitis.= Periostitis is an inflammation of the periosteum, the

outer covering of the bone. There are two types, the acute and the

chronic, both of which are not really diseases themselves, but are

indications of the reaction of the periosteum to some irritant. In

acute periostitis the X-ray plate shows a slight destruction of the

outer portion of the bone, and a slight thickening of the periosteum,

and if suppuration is present, the lesion is a mild osteomyelitis

rather than a periostitis.

Chronic periostitis causes an increase in the osteogenetic cells of

the periosteum and is common in a great many lesions. Trauma, blows

or contusions cause a chronic thickening of the bone covering with

additional bone formation, as do syphilis and superficial abscesses

in the soft tissues, in the immediate vicinity of long bones. Thus

chronic ulcer of the leg over the shaft of the tibia will produce this

condition. The picture shows that the even line of the bone surface is

lost, and there is a rough, uneven edge, with or without an increase

in the bone cells. The entire shaft of the bone is often thicker than

normal, especially in the metatarsals, and it is quite common to find

one of these bones greatly increased in size. The fourth metatarsal is

the one most usually affected.

=Exostosis.= This lesion is common in the foot, and is a source of

great pain and annoyance. It is usually the result of a chronic

bursitis which has affected the periosteum over a localized area. Due

to the destructive changes brought about by the inflammatory processes,

the periosteum is absorbed and the bone cells beneath protrude in

the form of a spur which shows on the plate. The most common site of

exostosis of the foot is on the inferior surface of the os calcis,

under the calcaneo bursa. The part is somewhat swollen and is extremely

painful when pressure is brought to bear directly over the growth.

The heads of the metatarsal bones on their lateral surfaces are

occasionally affected, especially the outer side of the head of the

first metatarsal. Lateral pressure gives rise to pain in this type of

exostosis. The treatment for all exostoses is purely surgical.

=Fractures.= There are several kinds of fracture, and they are

classified variously, but for the purposes of the podiatrist, the

following types, with the description of each, will prove sufficient:

=Incomplete Fractures=, among which are the greenstick and the fissured

fractures, are those in which there is not a complete separation of the

fragments. The greenstick is really a bending rather than a breaking of

the bone, and is found mostly in children under fifteen and then only

rarely affects the bones of the leg. Fissured fractures are splits or

cracks in the bone which do not separate it into two parts and occur

occasionally in the fibula or in the metatarsals. They are easily seen

in the radiograph by the dark shadow they produce in the region that

would ordinarily appear light. This shadow extends over the entire

length of the break.

=Complete Fractures= are the most common type found in the lower

extremity and are divided according to the line and the seat of the

breach of continuity. Thus we have transverse, longitudinal, oblique

and spiral fractures. The radiograph will reveal the nature of the

break, and a dark shadow will be cast between the fragments of bone.

The most common of these found in the leg are the oblique and the

spiral fractures.

=Comminuted Fractures= are those in which there is extensive

splintering of the bone adjoining the fracture or one of the fragments.

This class of fracture does not occur in the foot.

=Impacted Fractures= are those in which the fragments are driven into

each other, forming a wedge, thus preventing abnormal motion, so common

in other types. This occurs mostly in the neck of the femur.

=Crushing or Compression Fractures= are those in which the bones are

crushed. The spongy portion and the cortical layer are both involved

and in some cases the bones may be pulpified. The tarsal bones are

subject to this type of fractures as the result of falls from heights,

upon the soles of the feet. (See accompanying picture of fracture of

the os calcis.)

=A simple fracture= is one in which a wound of the skin is absent, or

if present, there is no connection between it and the broken bone.

If the bone is broken in two or more places or if two or more

non-adjacent bones are simultaneously broken, the condition is called a

=multiple fracture=.

[Illustration: FRACTURE OF THE OS CALCIS]

=A compound fracture= is one in which the fragments of bone pierce the

soft tissues and protrude beyond the skin.

It is essential in examining a patient who has suffered from a recent

fracture, to obtain a history of the case as well as a description

of the accident. An examination of the part should be made, and the

various symptoms such as deformity, abnormal mobility and crepitus

should be noted. The X-ray picture is then taken and if a fracture is

found, the case should be put in the hands of a competent surgeon for

immediate and proper treatment.

=Sesamoid Bones.= The sesamoid bones which are found in the flexor

tendons under the head of the first metatarsal bones, are subjected to

injury in those who follow vocations in which the ball of the foot is

put to great strains. Among such may be mentioned dancers and acrobats.

The normal position of these bones is directly beneath the head of the

first metatarsal bone, and when this part is put to a great strain, the

bones may become fractured, or they may become displaced. The outer

sesamoid is usually forced outward and the X-ray picture shows it in

the first interosseous space. The inner sesamoid is not affected, but

may also be forced outward, and is then found under the outer side of

the first metatarsal, in the normal position of the outer sesamoid bone.

Fracture of these bones is not unusual and is a result of a severe

injury. The line of division is shown by a dark shadow, much the same

as in other fractures. One or both of the bones may be involved. It is

essential to remember that if the bone is broken, the opposite sides

will fit into each other perfectly, whereas, in cases of a freakish

nature, in which there are four sesamoid bones, this will not be the

case.

=Arthritis.= Arthritis, or inflammation of the joints, may involve

any one or all of the structures which make up joints, viz., bone,

cartilage, ligaments, synovial membrane and fibro-cartilage. The acute

forms of inflammation are not detected by the radiogram, but the

chronic type leaves its characteristic marks which, when present,

are easily seen. The synovial covering of the ends of the bones

is destroyed, and shows a rough, uneven surface. In cases of long

standing, there is complete bony ankylosis, and the shadows of the

joint line are completely obliterated. This is particularly true in the

tarsal joints, in which the joint lines between the bones can hardly be

seen. There is no motion in such joints, and in milder cases, in which

no union has occurred, the sensation of crepitus is conveyed to the

hand if the joints are moved passively. Tubercular arthritis shows a

rarification of the bone with a thickening of the periosteum.

=Arteriosclerosis=, or hardening of the arteries, is often detected

by means of the X-ray picture. Light shadows cast in the normal dark

shade produced by the soft tissues, which appear over the course of the

arteries, are indications of this condition.

This disease of the arteries causes a change in the vessels whereby

there are calcareous salts deposited in the middle coat. These salts,

containing the metal calcium, are not readily penetrated by the ray,

and thus a difference between the artery and other soft tissues is

established.

There are many other conditions in which the X-rays are a valuable aid

in making diagnosis, but these are of no interest to the podiatrist,

being within the exclusive province of the physician and surgeon.

The reader is referred to books which deal with the subject of

Roentgenology exclusively, for further information upon the subject.

[Illustration: HALLUX VALGUS]

Practical podiatry · 第 25 / 27 章