26. Q. What is the cause of the fusing of the copper electrode?

A. Usually too high speed of the armature, although should you connect

the wires up wrong that the current flowing from the dynamo to the lamp

should enter the lamp at the electrode instead of passing through the

carbon first, you would get a green light and fuse the electrode.

27. Q. What arrangements have been made so that you cannot connect the

wires wrong?

A. The positive binding posts, both at the dynamo and the lamp, have

been provided with a much larger hole to receive the wire than has been

made in the negative binding posts, and the ends of the positive wire

should always be bent or doubled back, so that they will just enter the

receptacle in the positive binding posts, but cannot be connected at the

negative binding posts.

28. Q. Should the copper electrode and holder become fused until no

longer serviceable while on the road, what would you do?

A. Would remove the damaged holder from the lamp and substitute either

an iron bolt of sufficient length or a carbon, securing the improvised

electrode in the bracket of lamp same as the electrode holder is held,

only being sure that the end of the bolt or carbon comes up into the

center of the reflector and did not rest on the base of reflector or

lamp.

29. Q. What is the difference between a series wound equipment and a

compound wound equipment, and what advantages are obtained from the use

of the compound equipment.

A. With the series wound equipment, the incandescent cab lights burn

only with the arc lamp, while with the compound machine the incandescent

lamps are independent of the arc and can be used as desired.

30. Q. If you were running along with your light burning steadily and

nicely, then suddenly the light began to flash badly and kept it up,

where would you look for the trouble?

A. Trouble would usually be found at one of the binding posts, where one

of the binding post screws would be found loose.

31. Q. If you were running along with light burning satisfactorily and

suddenly it went out, where would you be likely to find the trouble?

A. You would find that either the carbon had burned out, one of the lead

wires had broken between the dynamo and the lamp, or one of the wires

had gotten loose at the binding post and fallen out.

32. Q. If the light goes out while you are between stations, what course

should an engineer pursue?

A. If the light goes out while you are between stations and an

investigation cannot be made within a few minutes thereafter to

determine the cause, the steam should be shut off from the turbine and

the dynamo stopped until such time when the cause of failure can be

determined.

The Traveling Engineers' Association to Improve the Locomotive Engine Service of American Railroads Examination Questions and Answers for Firemen for Promotion and New Men for Employment · 第 238 / 436 题