CHAPTER XX

ATWATER KENT IGNITION SYSTEM, TYPE K-2

The operating principle of the Atwater Kent ignition system type K-2,

differs from type CC system in that it operates on the open circuit

plan, whereas the type CC system explained in the preceding chapter,

operates on the closed circuit plan.

A-K ignition system type K-2 consists of three parts:

No. 1. The unisparker combining the special contact maker, a condenser,

and a high tension distributor.

No. 2. The coil, consisting of a simple primary and secondary winding,

and a condenser. These parts are all imbedded in a special insulating

compound. The coil has no vibrator or other moving parts.

No. 3. The ignition switch. This switch controls the system by opening

and closing the primary current.

=The Principle of the Atwater Kent System.=--The function of this

system is to produce a single hot spark for each power impulse of the

motor. It differs from other types of battery ignition systems in that

the contact points do not touch except during the brief instant of the

spark. The ignition circuit is, therefore, normally open, whence the

name “open circuit” results. The contact maker consists of a pair of

contact points, normally open, which are connected in series with a

battery, and the primary circuit of the non-vibrating induction coil.

The mechanism for operating the contacts consists of a notched shaft

having one notch for each cylinder, rotating at one-half the engine

speed, a lifter which is pulled forward by the rotation of the shaft,

and a coil spring which pulls the lifter back to its original position

after it has been drawn forward and released by the notched shaft;

hardened steel latch, against which the lifter strikes on its recoil

and which in turn operates the contact points.

[Illustration:

LATCH

CONTACT SCREW

NOTCHED SHAFT

LIFTER

CONTACT SPRING

LIFTER SPRING

Fig. 71. Atwater Kent Contact Breaker--Diagram of Action--Type K-2

System.]

[Illustration: Fig. 72. Atwater Kent Contact Breaker--Diagram of

Action--Type K-2 System]

[Illustration: Fig. 73. Atwater Kent Contact Breaker--Diagram of

Action--Type K-2 System]

[Illustration: Fig. 74. Atwater Kent Contact Breaker--Diagram of

Action--Type K-2 System]

=Operation of the Contact Maker.=--It will be noted in Fig. 71 that

the lifter is being pulled forward by the notched shaft. When pulled

forward as far as the shaft will carry it (Fig. 72), the lifter is

suddenly pulled back by the lifter spring. In returning, it strikes

against the latch, throwing this against the contact spring and closes

the contact for a brief instant. This movement is far too quick for

the naked eye to follow (Fig. 73).

Fig. 74 shows the lifter ready to be pulled forward by the next notch.

Note that the circuit is closed only during the brief instant of the

spark. No current can flow at any other time, not even if the switch is

left on when the motor is not running. No matter how slow or how fast

the notched shaft is turning, the lifter spring will always pull the

lifter back at exactly the same speed, so that the operation of the

contact, and therefore the spark, will always be the same no matter

how fast or how slow the engine is running. The brief instant that

the contact points touch, results in very little current consumption.

The high tension current from the coil is conveyed to the rotating

distributor block, which seats on the end of the unisparker shaft to

each of the spark plug terminals in the order of firing.

[Illustration: Fig. 75. Atwater Kent Distributor and Contactless Block]

The important advantage which the distributor possesses is the fact

that there are no sliding contacts or carbon brushes. The distributor

blade is so arranged that it passes close to the spark plug terminals

without quite touching (as shown in Fig. 75), thus permitting the spark

to jump the slight gap without any loss of current pressure. This also

eliminates all wear and trouble caused by sliding or rubbing contacts.

Fig. 76 shows the wire connections and direction of current flowage.

The distributor blade is about to make contact with the terminal

leading to the spark plug in No. 2 cylinder. At the instant that

contact is made the breaker points in the contact maker shown in the

lower part of the diagram close, thus allowing a primary or low tension

current to flow between the contact maker, coil, and battery. The

sudden breaking of this current occurs when the points open again,

thereby creating a current of high tension voltage in the secondary

coil which is conducted to the center terminal of the distributor where

it is distributed to the spark plug terminals through the rotation

of the distributor blade. The high tension cables leading from the

distributor are heavily insulated, thus the current in seeking ground

return chooses the easiest path, by jumping the slight gap at the spark

plugs.

[Illustration:

DISTRIBUTOR

GROUND

COIL

BATTERY

CONTACT MAKER

Fig. 76. Atwater Kent Wiring Diagram Type K-2]

=Setting and Timing the Unisparker.=--The type K-2 unisparker is

installed, so as to allow a small amount of angular movement or, in

other words, the socket into which the unisparker fits is provided

with a clamp which will permit it to be turned or locked in any given

position.

=Timing.=--The piston in No. 1 cylinder is raised to high dead center

between the compression and power stroke. Then loosen the clamp which

holds the unisparker and turn the unisparker backward, or contrary to

the direction of rotation until a click is heard. This click happens

at the exact instant of the spark. Clamp the unisparker tight at this

point being careful not to change its position. Note that current for

this system is usually supplied by the starting and lighting battery.

When changing batteries be sure that the voltage of the battery is the

same as that marked on the coil.

[Illustration:

TO PLUGS

TO PLUGS

CONTACT-MAKER

CONTACT MAKER

SWITCH

BAT.

S & INT.

INT.

S.

COIL

INT.

INT.

SEC

GROUND TO MOTOR

GROUND TO MOTOR

POS

NEG

BATTERY

Fig. 77. Atwater Kent K-2 Wiring--Cut 1, Under Hood Coil; Cut 2, Kick

Switch Coil]

The external wiring of the A-K type K-2 is very simple, as shown in the

diagrams, Figs. 77 and 77A. Fig. 77 shows the wire connections, when

the reversing switch and under-hood coil is used. Fig. 77A shows the

connections, when using plate or kick switch coil. A well insulated

braided primary wire is used for the primary or battery circuit. See

that this wire is well protected against rubbing or abrasion wherever

it comes into contact with metal parts of the car. When the starting

and lighting battery is used to furnish the ignition current, two wires

should run directly to the battery terminals.

The two types of Atwater Kent systems described are provided with

automatic spark advance mechanism. Provisions are also made for manual

lever control, by simply connecting the unisparker to the throttle

lever at the base of the steering gear.

[Illustration: Fig. 78. Atwater Kent Automatic Spark Advance

Mechanism--A K Type K-2]

Fig. 78 shows the automatic spark advance mechanism. It is located on

the underside of the contact maker base plate, and consists of a set

of weights which swing out from the center against spring tension,

and advances the unisparker on the shaft, according to the amount of

centrifugal action or speed of the shaft. When the shaft is not in

motion the springs draw the weights toward center, which automatically

shifts the unisparker on the shaft until the spark is in a fully

retarded position.

=Contact Point Adjustment.=--The only adjustment aside from the initial

timing is in the contact points. They are adjustable only for natural

wear, and one adjustment should last at least six months. The contact

screw is provided with a number of shim washers against which it is

set up tight. When the points eventually become worn, they should be

dressed flat and smooth. A sufficient number of the washers should

be removed so that when the contact screw is set up tightly it will

maintain the proper gap between the points. The distance between the

contact points should be about the distance of a thin visiting card.

They should never touch when at rest.

[Illustration:

Oil lightly every

1000 miles

Oil

Fig. 79. Atwater Kent Contact Breaker--Oiling Diagram--A-K Type K-2]

Fig. 79 shows an oiling diagram of the contact maker. The latch,

lifter, and lifter spring are not adjustable or subject to wear. They

should be well cleaned and oiled every five hundred miles. Use a light

oil and avoid getting it on the contact points.

=The Condenser.=--The condenser of this system acts somewhat like a

shock absorber to the contact points. It absorbs the spark or arc and

makes the break in the primary current, clean and abrupt. The condenser

is very accessible, but should never be tampered with, as it does not

require any attention.

=Testing for Ignition Trouble.=--If the engine misses without regard to

speed, test each cylinder separately by short circuiting the plug with

a screw driver, allowing a spark to jump. If all cylinders produce a

good regular spark the trouble is not with the ignition system.

If any cylinder sparks regularly this will indicate that the ignition

system is in working order so far as the unisparker and coil are

concerned. The trouble is probably in the high tension wiring between

the distributor and plug, or in the plugs themselves. Examine the plugs

and wiring carefully. Leaky secondary wiring is frequently the cause

of missing and backfiring.

Frequently, when high tension wires are run from the distributor to the

spark plugs through a metal tube, trouble is experienced with missing

and backfiring, which is due to induction between the various wires in

the tube. This is especially likely to happen if the main secondary

wire from the distributor to the coil runs through this tube with the

spark plug wires.

Whenever possible the distributor wires should be separated by at least

one-half inch of space. They should be supported by bracket insulators,

rather than run through a tube. In no case should the main distributor

wire run through a conduit with other wires.

If irregular sparking is noted at the spark plugs, examine the battery

and connections.

If the trouble commences suddenly, it is probably due to a loose

connection in the wiring, if gradually, the battery may be weakening or

the contact points may require attention.

The automobile owner's guide · 第 20 / 46 章