CHAPTER XIX

ATWATER KENT IGNITION SYSTEMS

CONSTRUCTION, OPERATION AND CARE

Atwater Kent ignition systems have been adopted of late by many

prominent automobile manufacturers as a means of distributing or

conveying electrical spark to the cylinders at the proper firing time.

This type of quick break distributing system has proved very efficient

and dependable, and will usually outlast the life of the motor as there

are very few moving parts, which eliminates troubles caused by worn

parts getting out of adjustment.

This type of ignition system operates in much the same manner as the

high tension magneto, and differs only in that the parts have been

taken from the compact magneto case and distributed in other locations

in separate units. As this type takes its current from the lighting and

starting battery, it does not contain an armature or field magnets to

manufacture the electrical force.

Fig. 66 illustrates the principles of operation of the type CC Atwater

Kent closed circuit system, which consists of the unisparker containing

the contact maker and distributor. The only moving parts are located

in this unit. The coil consists of a soft iron core, with a primary

and secondary winding sealed in an insulated tube or container. A

resistance unit is located in the top and regulates the current

automatically. The system is controlled by a switch located on the

dash. The contact breaker shown in Fig. 67 consists of an exceedingly

light steel contact arm. One end rests on a hardened steel cam which

rotates one-half as fast as the crank shaft. This cam has as many

sides as the engine has cylinders. When the contact points are opened

by the movement of the cam the primary circuit is broken and produces

a discharge of secondary high tension current at one of the spark plug

gaps.

[Illustration:

CONTACT

MAKER

TO PLUG

TO PLUG

DISTRIBUTOR

CONDENSER

TO PLUG

CONTACT MAKER

GROUNDED

SPARK PLUG

BATTERY

GROUND

PRIMARY

BATTERY

GROUND

SWITCH

SECONDARY

GROUND

REGULATING

RESISTANCE

Fig. 66. Atwater Kent Circuit Diagram--Type CC]

Fig. 68 shows the simple Atwater Kent contactless distributor. The high

tension distributor of the Atwater-Kent system forms the top of the

contact maker. Each spark plug wire terminates in an electrode, which

passes through the distributor cap. A rotating distributor block takes

the high tension current from the central terminal and distributes it

to the spark plugs in proper firing order. The distributor block or arm

does not make direct contact with the distributor posts. The current

jumps the small gap between the distributor block and the terminal

electrodes and does away with frictional wear resulting from actual

contact.

[Illustration: Fig. 67. Atwater Kent Contact Breaker--Type CC]

[Illustration: Fig. 68. Atwater Kent Distributor and Contactless Block]

Fig. 69 shows the method of connecting the high tension wires to the

distributor; the insulation is removed, or the wire bared in a space

1¹⁄₄″ long. The removable terminal cover is pushed up on the wire as

shown at A, the bared end of the wire is then passed through the hole

in the secondary terminal as shown at B. The end of this wire is then

twisted back on itself, for two complete turns as shown at C, so that

the end will not project beyond the diameter of the insulation. The

wire will then be tightly held when the terminal covers are screwed

down as shown in Fig. D. Never use pliers to tighten these covers and

do not solder the wires to the terminal posts.

[Illustration: Fig. 69. Distributor Wire Connections to Distributor]

=Adjustment.=--The only parts of this system that are adjustable are

the contact points. These need to be adjusted only for natural wear. Do

not adjust the points unless you are convinced, by trying everything

else, that it is the points that need attention.

In making adjustments, note the following directions. The normal gap

between the points should not be less than .005″, or more than .008″,

the standard setting is .006″, which is about the thickness of two

ordinary sheets of writing paper.

[Illustration:

TO UNGROUNDED

TERMINAL OF BATTERY

SWITCH

COIL

DISTRIBUTOR

GROUND

CONTACT

MAKER

Fig. 70. Atwater Kent Type CC Wiring Diagram]

The contact points are made of tungsten steel, the hardest known

metal. When contact points are working properly small particles of

tungsten steel will be carried from one point to the other, which

sometimes causes a roughness and a dark gray coloring of the surfaces.

This roughness does not in any way effect the proper working of the

points, owing to the fact that the rough surfaces fit into each other

perfectly.

It should not be necessary to file or redress the points unless they

become burned, due to some abnormal condition or accident. The dark

gray appearance is the natural color of the tungsten steel.

=Oilings.=--A very small amount of ordinary vaseline or grease applied

to the cam and a drop or two of oil applied to the cups every few

weeks, is all the lubrication necessary. Do not get oil on the contact

points, and wipe off any free oil or grease on the contact maker.

The springs in this system are set at exactly the right tension. Do not

try to bend or tamper with them.

The wiring of the type CC ignition system is very simple, as shown in

Fig. 70, and is known as the one wire with ground return method. Well

insulated primary wire is used for the primary circuit between the

coil and the ignition switch. The best quality of five-sixteenth inch

secondary wire is used to conduct the high tension current from the

coil to the distributor, and from the distributor to the spark plug.

=Setting or Timing the Type CC System.=--The piston in number one

cylinder should be raised to high dead center, between the compression

and firing strokes, the clamp which holds the unisparker should be

loosened and the unisparker turned backward, or opposite the rotating

direction of the timer shaft until the contact points commence to open.

The spark occurs at the exact instant of the opening of the point.

After completing the electrical connection the current can be turned

on, and the unisparker timed exactly from the spark at the plugs. For

this purpose the plugs should be removed from the engine and laid on

top of the cylinders.