FUSIBLE PLUG

We have told you about a safety valve, we will now have something to say

of a safety plug. A safety, or fusible plug, is a hollow brass plug or

bolt, screwed into the top crown sheet. The hole through the plug being

filled with some soft metal that will fuse at a much less temperature

than is required to burn iron. The heat from the firebox will have no

effect on this fusible plug as long as the crown sheet is covered with

water, but the moment that the water level falls below the top of the

crown sheet, thereby exposing the plug, this soft metal is melted and

runs out, allows the steam to rush down through the opening in the lug,

putting out the fire and preventing any injury to the boiler. This all

sounds very nice, but I am free to confess that I am not an advocate of

a fusible plug. After telling you to never allow the water to get low,

and then to say there is something to even make this allowable, sounds

very much like the preacher who told his boy "never to go fishing on

Sunday, but if he did go, to be sure and bring home the fish." I would

have no objection to the safety plug if the engineer did not know it was

there. I am aware that some states require that all engines be fitted

with a fusible plug. I do not question their good intentions, but I do

question their good judgment. It seems to me the are granting a license

to carelessness. For instance, an engineer is running with a low gauge

of water, owing possibly to the tank being delayed longer than usual, he

knows the water is getting low, but he says to himself, "well, if the

water gets too low I will only blow out the plug," and so he continues

to run until the tank arrives. If the plug holds, he at once begins to

pump in cold water, and most likely does it on a very hot sheet, which

of itself, is something he never should do; and if the plug does blow

out he is delayed a couple of hours, at least, before he can put in a

new plug and get up steam again. Now suppose he had not had a soft plug

(as they are sometimes called). He would have stopped before he had low

water. He would not even have had a hot crown sheet, and would only

have lost the time he waited on the tank. This is not a fancied

circumstance by any means, for it happens every day. The engineer

running an engine with a safety plug seldom stops for a load of water

until he blows out the plug. It frequently happens that a fusible plug

becomes corroded to such an extent that it will stand a heat sufficient

to burn the iron. This is my greatest objection to it. The engineer

continues to rely on it for safety, the same as if it were in perfect

order, and the ultimate result is he burns or cracks his crown sheet. I

have already stated that I have no objection to the plug, if the

engineer did not know it was there, so if you must use one, attend to

it, and every time you clean your boiler scrape the upper or water end

of the plug with a knife, and be careful to remove any corrosive matter

that may have collected on it, and then treat your boiler exactly as

though there was no such a thing as a safety plug in it. A safety plug

was not designed to let you run with any lower gauge of water. It is

placed there to prevent injury to the boiler, in case of an accident or

when, by some means, you might be deceived in your gauge of water, or if

by mistake, a fire was started without any water in the boiler.

Should the plug melt out, it is necessary to replace it at once, or as

soon as the heat will permit you to do so. It might be a saving of time

to have an extra plug always ready, then all you have to do is to remove

the melted one by unscrewing it from the crown sheet and screwing the

extra one in. But if you have no extra plug you must remove the first

one and refill it with babbitt. You can do this by filling one end of

the plug with wet clay and pouring the metal into the other end, and

then pounding it down smooth to prevent any leaking. This done, you can

screw the plug back into its place.

If you should have two plugs, as soon as you have melted out one replace

it with the new one, and refill the other at your earliest convenience.

By the time you have replaced a fusible plug a few times in a hot boiler

you will conclude it is better to keep water over your crown sheet.