HOW TO TEST A STEAM GAUGE

Take it off, and take it to some shop where there is a steam boiler in

active use; have the engineer attach your gauge where it will receive

the direct pressure, and if it shows the same as his gauge, it is

reasonable to suppose that your gauge is correct. If the engineer to

whom you take your gauge should say he thinks his gauge is weak, or a

little strong, then go somewhere else. I have already told you that I

did not want you to think anything about your engine-I want you to know

it. However, should you find that your gauge shows when tested with

another gauge, that it is weak, or unreliable in any way, you want to

repair it at once, and the safest way is to get a new one; and yet I

would advise you first to examine it and see if you cannot discover the

trouble. It frequently happens that the pointer becomes loosened on the

journal or spindle, which attaches it to the mechanism that operates it.

If this is the trouble, it is easily remedied, but should the trouble

prove to be in the spring, or the delicate mechanism, it would be much

more satisfactory to get a new one.

In selecting a new gauge you will be better satisfied with a gauge

having a double spring or tube, as they are less liable to freeze or

become strained from a high pressure, and the double spring will not

allow the needle or pointer to vibrate when subject to a shock or sudden

increase of pressure, as with the single spring. A careful engineer

will have nothing to do with a defective steam gauge or an unreliable

safety valve. Some steam gauges are provided with a seal, and as long

as this seal is not broken the factory will make it good.