motor were shunt or compound wound, cause most serious sparking
and various other troubles, but in a series motor where the back
ampere turns on the armature that react on the field vary in
precisely the same proportion as the ampere turns in the field,
there exists at all times a tendency to balance the active forces
and produce satisfactory operation. If, however, the field magnet
cores be very large, they cannot so quickly respond, magnetically,
to changes in the strength of the current, and there is then
greater liability of the armature reaction momentarily weakening
the field and thereby producing temporary sparking.
=Ques. Are motor generators always composed of direct current sets?=
Ans. No.
=Ques. Describe conditions requiring a different combination.=
Ans. For purposes where for instance direct currents of widely
different voltages are to be obtained from an alternating current
circuit, and it is desired to install but one set, a motor generator
consisting of an alternating current motor such as an induction
motor, and a dynamo must necessarily be employed.
In such sets, it is common to find both motor and dynamo
armatures mounted on a common shaft, and the respective field
frames resting on a single base, although for connection on a
very high pressure alternating current circuit, separate armature
shafts insulated from each other but directly connected together,
and separate bases resting on a single foundation, are usually
employed to afford the highest degree of insulation between the
respective circuits of the two machines.
=Ques. What is the objection to a set composed of alternating current
motor and alternator?=
Ans. The commercial field that would be naturally covered by such a
set is better supplied by a transformer.
=Ques. Why?=
Ans. Because a transformer contains no moving parts, and is therefore
simpler in construction, cheaper in price, and less liable to get out
of order.
=Dynamotors.=--A dynamotor differs from a motor generator in that
the motor armature and the generator armature are combined into one,
thereby requiring but one field frame. Since the motor and generator
armature windings are mounted on a single core, the armature reaction
due to the one winding is neutralized by the reaction caused by the
other winding. There is, consequently, little or no tendency for
sparking to occur at the brushes, and they therefore need not be
shifted on this account for different loads.
=Ques. How is a dynamotor usually constructed?=
Ans. It is usually built with two pole pieces which are shunt wound.
=Ques. Why does the voltage developed fall off slightly under an
increase of load?=
Ans. Because a compound winding cannot be provided.
[Illustration: FIGS. 2,862 and 2,863.--Method of putting on belts
when the driver is in motion, and device used. The latter is called a
_belt slipper_, and consists, as shown in fig. 2,862, of a cone and
shield, which revolve upon the stem, B, thus yielding easily to the
pull of the belt. A staff or handle C of any convenient length can be
fastened to the socket. The mode of operation is illustrated in fig.
2,863, which is self explanatory.]
=Ques. Describe the armature construction and operation.=
Ans. It consists of two separate windings; one of which is joined to
a commutator mounted on one side of the armature for motor purposes,
and the other to the commutator on the other side of the armature for
generator purposes.
By means of two studs of brushes pressing on the motor
commutator, current from the service wires is fed into the winding
connected to this commutator, and since the shunt field winding
is also excited by the current from the service wires, there is
developed in the generator winding on the rotating armature a
direct voltage which is proportional to the speed of rotation of
the armature in revolutions per second, the number of conductors
in series which constitute the generator winding, and the total
strength of the field in which the armature revolves. This
pressure causes current to pass through the generator winding and
the distributing circuit when the distributing circuit to which
this winding is connected by means of its respective commutator,
brushes, etc., is closed.
[Illustration: FIGS. 2,864 to 2,866.--Converter connections; fig.
2,864 double delta connection; fig. 2,865 diametrical connection;
fig. 2,866 two circuit single phase connection. For six phase
synchronous converter, two different arrangements of the connections
are generally used. One is called the _double delta_, and the other
the _diametrical_ connection. Let the armature winding of the
converter be represented by a circle as in figs. 2,864 and 2,865,
and let the six equidistant points on the circumference represent
collector rings, then the secondary of the supply transformers can
be connected to the collector rings in a _double delta_ as in fig.
2,864, or across diametrical pairs of pointer as in fig. 2,865.
In the first instance, the voltage ratio is the same as for the
three phase synchronous converter and simply consists of two delta
systems. The transformers can also be connected in double star, and
in such a case the ratio between the three phase voltage between
the terminals of each star, and the direct voltage will be the same
as for double delta, while the voltage of each transformer coil,
or voltage to neutral, is 1 ÷ √3 times as much. With the
diametrical connection, the ratio is the same as for the two ring
single phase converter, it being analogous to three such systems.
_ _
Hence six phase double delta E_{1} = √3E ÷ 2√2 = .612E.
Six phase diametrical, E_{1} = E ÷ √2 = .707E. The ratio of the
virtual_voltage E_{0} between any collector ring and the neutral
point is always E_{0} = (E ÷ 2) √2 = .354E. For single phase
synchronous converters, consisting of a closed circuit armature
winding tapped at two equidistant points to the two collector rings
the virtual voltage is 1 ÷ √2 × the direct current voltage. While
such an arrangement of the single phase converter is the simplest,
requiring only two collector rings, it is undesirable, especially
for larger machines, on account of excessive heating of the armature
conductors. In fig. 2,866, which represents the armature winding of a
single phase converter, the supply circuits from two secondaries of
the step down transformers are connected to four collector rings, so
that the two circuits are in phase with each other, but each spreads
over an arc of 120 electrical degrees instead of over 180 degrees
as in the single phase circuit converter. To distinguish the two
types, it is generally called a two circuit single phase synchronous
converter. The virtual voltage E_{2} bears to the direct voltage the
same relation as in the three phase converter, that is single phase
two circuit, E_{1} = √3 ÷ 2√2 =.612E.]
=Ques. How is a dynamotor started?=
Ans. It is connected at its motor end and started in the same manner
as any shunt wound motor on a constant pressure circuit.
=Ques. What precautions should be taken in starting a dynamotor?=
Ans. The necessary precautions are, to have the poles strongly
magnetized before passing current through the motor winding on the
armature; to increase gradually the current through this winding, and
not to close the generating circuit until normal conditions regarding
speed, etc., are established in the motor circuit.
=Ques. How is the current developed in the machine regulated?=
Ans. It can be regulated by the introduction of resistance in one or
the other of the armature circuits, or by a shifting of the brushes
around the commutator.
=Ques. Are dynamotors less efficient than motor generators of a
similar type?=
Ans. No, they are more efficient.
=Ques. Why?=
Ans. Because they have only one field circuit and at least one
bearing less than a motor generator.
A motor generator has at least three bearings, and occasionally,
four, where the set consists of two independent machines directly
connected together.
=Rotary Converters.=--An important modification of the dynamotor
is the rotary converter. This machine forms, as it were, a link
between alternating and direct current systems, being in general a
combination of an alternating current motor and a dynamo.
[Illustration: FIG. 2,867.--Skeleton diagram showing wiring of
alternator, exciter, transformer and converter. The cut also shows
switchboard and connections.]
It has practically become a fixture in all large electric railway
systems and in other installations where heavy direct currents of
constant pressure are required at a considerable distance from the
generating plant. In such cases a rotary converter is installed
in the sub-station, and being simpler in construction, higher in
efficiency, more economical of floor space, and lower in price than
a motor generator set consisting of an alternating current motor and
a dynamo which might be used in its place, it has almost entirely
superseded the latter machine for the class of work mentioned.
=Ques. What is the objection to the single phase rotary converter?=
Ans. It is not self-starting.
=Ques. What feature of operation is inherent in a rotary converter?=
Ans. A rotary converter is a "reversible machine."
That is to say, if it be supplied with direct current of the
proper voltage at its commutator end, it will run as a direct
current motor and deliver alternating current to the collector
rings. While this feature is sometimes taken advantage of in
starting the converter from rest, the machine is not often used
permanently in this way, its commercial application being usually
the conversion of alternating currents into direct currents.
=Ques. How does a rotary converter operate when driven by direct
current?=
Ans. The same as a direct current motor, its speed of rotation
depending upon the relation existing between the strength of the
field and the direct current voltage applied.
If the field be weak with respect to the armature magnetism
resulting from the applied voltage, the armature will rotate at a
high speed, increasing until the conductors on the armature cut
the lines of force in the field so as to develop a voltage which
will be equal to that applied.
Again, if the field be strong with respect to the armature
magnetism, resulting from the applied voltage, the armature will
rotate at a low speed. If, therefore, it be desired to operate the
converter in this manner and maintain an alternating current of
constant frequency, the speed of rotation must be kept constant by
supplying a constant voltage not only to the brushes pressing on
the commutator, but also to the terminals of the field winding.
[Illustration: FIG. 2,868.--General Electric synchronous converter
with series booster. This type of converter generally consists of
an alternator with revolving field mounted on the same shaft as the
converter armature. The armature of the alternator, or booster, as it
is usually called, is stationary and connected electrically in series
between the supply circuit and the collector rings of the synchronous
converter. The booster field has the same number of pole as the
converter and is generally shunt wound. A change in the booster
voltage will correspondingly change the alternating voltage impressed
on the converter and this regulation can, of course, be made so as
to either increase or decrease the impressed voltage by means of
strengthening or weakening the booster field. The voltage variation
can be made either non-automatic or automatic, and in the latter
case, it becomes necessary to provide a motor operated rheostat
controlled by suitable relays, or the booster can be provided with
a series field. By means of a booster, it is possible to vary the
direct voltage of the converter with a constant alternating supply
voltage, and this voltage regulation is obtained without disturbance
of the power factor or wave shape of the system. Synchronous
converters are frequently installed in connection with Edison
systems, where three wire direct current is required. The three wire
feature is obtained either by providing extra collector rings and
compensator, as with ordinary direct current generators, or also by
connecting the neutral wire directly to the neutral point of the
secondary winding of step down transformers, if such be furnished.]
=Ques. How does it operate with alternating current drive?=
Ans. The same as a synchronous motor.
=Ques. What is the most troublesome part and why?=
Ans. The commutator, because of the many pieces of which it is
composed and the necessary lines along which it is constructed, its
peripheral speed must be kept within reasonable limits.
=Ques. What should be the limit of the commutator speed?=
Ans. The commutator speed, or tangential speed at the brushes should
not exceed 3,000 feet per minute.
[Illustration: FIG. 2,869.--Wiring diagram for General Electric
synchronous converter with series booster as illustrated in fig.
2,868.]
=Ques. Name another limitation necessary for satisfactory operation.=
Ans. The pressure between adjacent commutator bars should not exceed
eight or ten volts.
If the commutator bars be made narrow in order to obtain
the necessary number for the desired voltage with the minimum
circumference and therefore low commutator speed, the brushes
employed to collect the current are liable to require excessive
width in order to provide the proper cross section and yet not
cover more than two bars at once.
=Ques. How can the commutator speed be kept within reasonable limits,
other than by reducing the width of the commutator bars?=
Ans. By using alternating current of comparatively low frequency.
For a rotary converter delivering 500 volt direct current, the
proper frequency for the alternating current circuit has been
found to be 25 cycles per second.
=Ques. When a rotary converter is operated in this usual manner on an
alternating current circuit, how can the direct current be varied?=
Ans. It may be varied (from zero to a maximum) by changing the value
of the alternating pressure supplied to the machine, or it may be
altered within a limited range by moving the brushes around the
commutator, or in a compound wound converter by changing the amount
of compounding.
Under ordinary conditions, varying the voltage developed by
changing the voltage at the motor end is not practical, hence
the voltage developed can be varied only over a limited range.
In addition to this, the voltage developed at the direct current
end bears always a certain constant proportion to the alternating
current voltage applied at the motor end; this is due to the same
winding being used both for motor and generator purposes. In all
cases the proportion is such that the alternating current voltage
is the lower, being in the single phase and in the two phase
converters about .707 of the direct current voltage, and in the
three phase converter about .612 of the direct current voltage.
It is thus seen that whatever value of direct current voltage be
desired, the value of the applied alternating current voltage must
be lower, requiring in consequence the installation of step down
transformers at the sub-station for reducing the line wire voltage
to conform to the direct current pressure required.
=Ques. What is the efficiency of a rotary converter?=
Ans. It may be said to have approximately the same efficiency as that
in the average of the same output, although in reality the converter
is a trifle more efficient on account of affording a somewhat shorter
average path for the current in the armature, reducing in consequence
the resistance loss and the armature reaction.
=Ques. May a converter be overloaded more than a dynamo of the same
output, and why?=
Ans. Yes, because there is usually less resistance loss in the
armature of the converter than in the armature of the dynamo.
[Illustration: FIG. 2,870.--Wiring diagram for three wire synchronous
converter with delta-Y connected step down transformer with the
neutral brought out. It is evident that in this case each transformer
secondary receives ⅓ of the neutral current, and if this current
be not so small, as compared with the exciting current of the
transformer, it will cause an increase in the magnetic density.]
Thus, a two phase converter may be overloaded approximately 60
per cent., and a three phase converter may be overloaded about 30
per cent. above their respective outputs if operated as dynamos.
=Ques. Describe how a converter is started.=
Ans. There are several methods any one of which may be employed, the
choice in any given case depending upon which of them may best be
followed under the existing conditions.
If it be found advisable to start the converter with direct
current, the same connections would be made between the source of
the direct current and the armature terminals on the commutator
side of the converter as would be the case were a direct current
shunt motor of considerable size to be started; this naturally
means that a starting rheostat and a circuit breaker will be
introduced in the armature circuit.
The shunt field winding alone is used, and this part of the
wiring may be made permanent if, as is usually the case, the same
source of direct current is used normally for separate field
excitation.
[Illustration: FIG. 2,871.--Wiring diagram of three wire synchronous
converter with distributed Y secondary. This system eliminates the
flux distortion due to the unbalanced direct current in the neutral.
Two separate interconnected windings are used for each leg of the Y.
The unbalanced neutral current flowing in this system may be compared
in action to the effect of a magnetizing current in a transformer.
The effect of the main transformer currents in the primary and
secondary is balanced with regard to the flux in the transformer
core, which depends upon the magnetic current. When a direct current
is passed through the transformer, unless the fluxes produced by
the same neutralize one another, its effect on the transformer iron
varies as the magnetizing current. For example, assume a transformer
having a normal ampere capacity of 100 and, approximately, 6 amperes
magnetizing current, and assume that three such transformers are
used with Y connected secondaries for operating a synchronous
converter connected to a three wire Edison system. Allowing 25 per
cent. unbalancing, the current will divide equally among the three
legs giving 8.33 amperes per leg, which is more than the normal
magnetizing current. The loss due to this current is, however,
inappreciable, but the increased core losses may be considerable.
If a distributed winding be used, the direct current flows in the
opposite direction, around the halves of each core thus entirely
neutralizing the flux distortion. Whether the straight Y connection
is to be used is merely a question of balancing the increased core
loss of the straight Y connection against the increased copper loss
and the greater cost of the interconnected Y system. The straight
Y connection is much simpler, and it would be quite permissible to
use it for transformers of small capacities where the direct current
circulating in the neutral is less than 30 per cent. of the rated
transformer current.]
The direct current may be derived from a storage battery, from a
separate converter, or from a motor generator set installed in the
sub-station for the purpose.
An adjustable rheostat will, of course, be connected in the
field circuit for regulation. Before starting the converter,
however, it is necessary to do certain wiring between the
terminals on the collector side of the machine and the alternating
current supply wires, in order that the change over from direct
current motive power to alternating current motive power may be
made when the proper phase relations are established between
the alternating current in the supply wires and the alternating
current in the armature winding of the converter.
In order that proper phase relations exist, the armature
of the converter must rotate at such a speed that each coil
thereon passes its proper reversal point at the same time as the
alternating current reverses in the supply wires. This speed may
be calculated by doubling the frequency of the supply current and
then dividing by the number of pole pieces on the converter, but a
far more accurate method of judging when the converter is in step
or in synchronism with the supply current consists in employing
incandescent lamps as shown in fig. 2,872.
=Ques. How is a polyphase converter started with alternating current?=
Ans. This may be done by applying the alternating pressure directly
to the collector rings while the armature is at rest. There need
be no field excitation; in fact the field windings on the separate
pole pieces should be disconnected from each other before the
alternating voltage is applied to the armature, else a high voltage
will be induced in the field windings which may prove injurious to
their insulation. The passage of the alternating current through the
armature winding produces a magnetic field that rotates about the
armature core, and induces in the pole pieces eddy currents, which,
reacting on the armature, exert a sufficient torque to start the
converter from rest and cause it to speed up to synchronism.
=Ques. How much alternating current is required to start a polyphase
converter?=
Ans. About 100 per cent. more than that required for full load.
=Ques. How may this starting current be reduced?=
Ans. Transformers may be switched into circuit temporarily to reduce
the line wire voltage until the speed become normal.
[Illustration: FIG. 2,872.--Wiring diagram showing arrangement of
incandescent lamps for determining the proper phase relations in
starting a rotary converter. The alternating current side of a
three phase converter is shown at C. The three brushes, D, T and G
pressing on its collector rings are joined in order to the three
single pole switches H, L and B which can be made to connect with
the respective wires M, R, and V, of the alternating current supply
circuit. Across one of the outside switches, H, for example, a number
of incandescent lamps are joined in series as indicated at E, while
the three pole switch (not shown) in the main circuit, between the
alternator and the single pole switches is open. If then the main
switch just mentioned and the middle switch L be both closed, and
the armature of the alternator be brought up to normal speed by
running it as a direct current motor, the lamps at E will light up
and darken in rapid succession; the lighting and darkening of the
lamps will continue until, by a proper adjustment of the speed,
the correct phase relations be established between the alternating
current in the supply circuit and the alternating current developed
in the armature of the converter. As this condition is approached,
the intervals between the successive lighting up and darkening of
the lamps will increase until they remain perfectly dark. There is
then no difference of pressure between the supply circuit M R V and
the rotary converter armature circuit, so the source of the direct
current may at that instant be disconnected from the machine, and the
switches H and B, closed. If the change over has been accomplished
before the phase relations of the two circuits differed, the
converter will at once conform itself to the supply circuit and run
thereon as a synchronous motor without further trouble. The opening
of the direct current circuit and the closing of the alternating
current supply circuit may be done by hand, but preferably by
employing a device that will automatically trip the circuit breaker
in the direct current circuit at the instant the switches in the
alternating current circuit are closed.]
In conjunction with this method, the method of synchronizing
shown in fig. 2,872 may be used, thus, in starting, there is
an alternating current between the brushes which pulsates very
rapidly, but when synchronism is approached, the pulsations
become less rapid until finally with the converter in step with
the alternator the pulsations entirely disappear.
The light given by the lamps thus connected indicates accurately
the condition of affairs at any one time, varying from a rapidly
fluctuating light at the beginning to one of constant brilliancy
at synchronism.
[Illustration: FIG. 2,873.--Diagram of motor converter. This machine
which is only to be used for converting from alternating to direct
current, consists of an ordinary induction motor with phase wound
armature, and a dynamo. The revolving parts of both machines are
mounted on the same shaft and from the figure it is seen that the
armature of the motor and the armature of the dynamo are also
electrically connected. The motor converter is a synchronous machine,
but the dynamo receives the current from the armature of the motor at
a frequency much reduced from that impressed upon the field winding
of the motor. Assuming that the motor and the converter have the same
number of pole, the motor will rotate at a speed corresponding to
one-half the frequency of the supply circuit. The motor will operate
half as a motor and half as a transformer, and the converter, half
as a dynamo and half as a synchronous converter, in that one-half of
the electrical energy supplied to the motor will be converted into
mechanical power for driving the converter, while the other one-half
is transferred to the secondary motor windings and thereby to the
converter armature in the form of electrical power. The capacity of
the motor is theoretically only half what it would be if it were to
convert the whole of the electrical energy into mechanical power
because the rating depends upon the speed of the rotating field and
not on that of the rotor. If the two machines have a different number
of pole, or are connected to run at different speeds, the division of
power is at a different but constant ratio. The machine starts up as
an ordinary polyphase induction motor and the field of the converter
is built up as though it were an ordinary dynamo. Motor converters
are occasionally used on high frequency systems, as their commutating
component is of half frequency, and thus permits better commutator
design than a high frequency converter. The advantage of this type
of machine is that for phase control it requires no extra reactive
coils, the motor itself having sufficient reactance. It is, however,
larger than standard converters, but smaller than motor generators,
as half the power is converted in each machine. Its efficiency is
less than for synchronous converters, and the danger of reaching
double speed in case of a short circuit on the direct current side
is very great. It has been used abroad to some extent for 60 cycle
work, in preference to synchronous converters, but with the present
reliable design of 60 cycle converters, and the general use of 25
cycles, where severe service conditions are met, as in railroading,
motor converters should not be recommended.]
=Ques. If the armature of the starting motor have a starting
resistance, how must this be connected?=
Ans. It should be connected in series with the armature inductors
before the alternating voltage is applied.
As the motor increases in speed, the starting resistance is
gradually short circuited until it is entirely cut out of circuit.
[Illustration: FIG. 2,874.--Sectional view of General Electric
vertical synchronous converter. In this construction, the field frame
carrying the poles is mounted on cast iron pedestals and is split
vertically. This allows the two halves of the frame to be separated
for inspection or repairs of the armature. The armature, including
commutator and collector rings, is mounted on a vertical stationary
shaft, which is rigidly supported from the foundation. The thrust
of the armature is carried on a roller bearing attached to the top
of the shaft and upper side of the armature spider. The under side
of the lower plate of the roller bearing is made spherical and fits
into a corresponding spherical cup on the end of the shaft, making
the bearing self aligning. The armature spider has a babbitted sleeve
along the fit of the vertical shaft, which acts as a guide bearing
and has to take only the thrust due to the unbalancing effect of
the rotating parts. A circulating pump furnishes oil to the roller
bearing, the oil draining off through the guide bearing. A marked
advantage of this type of construction is the accessibility of the
commutator for adjustment of the brushes, etc., as there is no pit or
pedestal bearing to interfere.]
NOTE.--Some converters are provided
with a small induction motor for starting
mounted on an iron bracket cast in the converter
frame, and whose shaft is keyed to that of the
converter. Allowing for a certain amount of
slip in the induction motor, the field of this
machine must possess a less number of magnet
poles than the converter in order to enable the
latter machine to be brought to full synchronism.
To start the induction motor, it is simply
necessary to apply to its field terminals the
proper alternating voltage. The bracket, and
therefore the motor, is usually mounted outside
the armature bearing on the collector side of the
converter.
[Illustration: FIG. 2,875.--Resistance measurement by "drop" method.
The circuit whose resistance is to be measured, is connected in
series with an ammeter and an adjustable resistance to vary the
flow of current. A voltmeter is connected directly across the
terminals of the resistance to be measured, as shown in the figure.
According to Ohm's law I = E ÷ R, from which, R = E ÷ I. If then the
current flowing in the circuit through the unknown resistance be
measured, and also the drop or difference of pressure, the resistance
can be calculated by above formula. In order to secure accurate
determination of the resistance such value of current must be used
as will give large deflections of the needle on the instruments
employed. A number of independent readings should be taken with some
variation of the current and necessarily a corresponding variation
in voltage. The resistance should then be figured from each set
of readings and the average of all readings taken for the correct
resistance. Great care must be taken, however, in the readings, and
the instruments must be fairly accurate. For example, suppose that
the combined instrument error and the error of the reading in the
voltmeter should be 1 per cent., the reading being high, while the
corresponding error of the ammeter is 1 per cent. low. This would
cause an error of approximately 2 per cent. in the reading of the
resistance. In making careful measurements of the resistance, it is
also necessary to determine the temperature of the resistance being
measured, as the resistance of copper increases approximately .4
of 1 per cent. for each degree rise in temperature. Use is made of
this fact for determining the increase in temperature of a piece of
apparatus when operating under load. The resistance of the apparatus
at some known temperature is measured, this being called the cold
resistance of the apparatus. At the end of the temperature test the
hot resistance is taken. Assume the resistance has increased by 15
per cent. This would indicate a rise in temperature of 37½ degrees
above the original or cold temperature of the apparatus. Suppose then
that in measuring the cold resistance, results are obtained which are
2 per cent. low, and that in measuring the hot resistance, there be
2 per cent. error in the opposite direction. This would mean that a
total error of 4 per cent. had been made in the difference between
the hot and cold resistances, or an error of 10 degrees. The correct
rise in temperature is, therefore, about 27½ instead of 37½ degrees.
In other words, an error of 2 per cent. in measuring each resistance
has caused an error of approximately 36½ per cent. in the measurement
of the rise in temperature. The constant .4 which has been used above
is only approximate and should not be used for exact work. For detail
instructions of making calculations of resistance and temperature,
see "Standardization Rules of the A.I.E.E."]
=Ques. Describe the usual wiring for the installation of a rotary
converter in a sub-station.=
Ans. Commencing at the entrance of the high pressure cables, first
there is the wiring for the lightning arresters, then for the
connection in circuit of the high tension switching devices, from
which the conductors are led to bus bars, and thence to the step down
transformers.
[Illustration: Figs. 2,876 to 2,879.--How to connect instruments
for power measurement. There are several ways of connecting an
ammeter, voltmeter and wattmeter in the circuit for the measurement
of power. A few of the methods are discussed below. With some of the
connections it is necessary to correct the readings of the wattmeter
for the losses in the coil, or coils, of the wattmeter, or for losses
in ammeter or voltmeter. This is necessary since the instruments may
be so connected that the wattmeter not only measures the load but
includes in its indications some of the instrument losses. If the
load measured be small, or considerable accuracy is required, these
instrument losses may be calculated as follows: Loss in pressure
coils is E^{2} ÷ R, in which E is the voltage at the terminals of
the pressure coil and R is the resistance. Loss in current coil is
I^{2} R in which I is the current flowing and R the resistance of the
current coil. In general let E_{v} = voltage across terminals of the
voltmeter; E_{_w_} = voltage across the terminals of the pressure
coil of the wattmeter; I_{_w_} = current through current coil of
wattmeter; I_{_a_} = current through current coil of ammeter; R_{_v_}
= resistance of pressure coil of voltmeter; R_{_w_} = resistance of
pressure coil of wattmeter; R^{1}_{w} = resistance of current coil
of wattmeter; R_{_a_} = resistance of current coil of ammeter. Then
the losses in the various coils will be as follows: E^{2}_{_v_} ÷
R_{_v_} = loss in pressure coil of voltmeter. E^{2}_{_w_} ÷ R_{_w_}
= loss in pressure coil of wattmeter. I^{2}_{_w_} ÷ R_{_v_} = loss
in current coil of wattmeter. I^{2}_{_a_}R_{_a_} = loss in current
coil of ammeter. If connection be made as in fig. 2,876, the correct
power of the circuit will be the wattmeter reading W-(E^{2}_{_v_} ÷
R_{_v_} + E^{2}_{_w_} ÷ R_{_w_}) in which E_{_v_} = E_{_w_}. In fig.
2,877, the power is W-E^{2}_{_w_} ÷ R_{_w_}. In fig. 2,878, the power
is W-I^{2}_{_w_}R^{1}_{_w_}, or the correct power is the wattmeter
reading minus the loss in the current coil of the wattmeter. In fig.
2,879, the power is W-(E^{2}_{_w_} ÷ R_{_w_} + I^{2}_{_a_}R_{_a_})·
The usual method of connection is either as in fig. 2,876 or fig.
2,877. In either case the current reading is that of the load plus
the currents in the pressure coils of the voltmeter and wattmeter.
Unless the current being measured, however, is very small, or extreme
accuracy is desired, it is unnecessary to correct ammeter readings.
In fig. 2,877 a small error is introduced due to the fact that the
actual voltage applied to the load is that given by the voltmeter
minus the small drop in voltage through the current coil of the
wattmeter. If an accurate measure of the current in connection with
the power consumed by the load be required, the connections shown
in fig. 2,879 are used, and if extreme accuracy is required, the
wattmeter reading is reduced by the losses in the ammeter and in
the pressure coil of the wattmeter. The loss in the pressure coil
of a wattmeter or voltmeter may be as high as 12 or 15 watts at 220
volts. The loss in the current coil of a wattmeter with 10 amperes
flowing may be 6 or 8 watts. It can be easily seen that if the core
or copper losses of small transformers are being measured, it is
quite necessary to correct the wattmeter readings, for the instrument
losses. In measuring the losses of a 25 or 50 H.P. induction motor,
the instrument losses may be neglected. A careful study of the above
will show when it becomes necessary to correct for instrument losses
and the method of making these corrections. Connections are seldom
used which make it necessary to correct for the losses in the current
coils of either ammeter or wattmeter, as the losses vary with the
change in the current. On the other hand, the voltages generally
used are fairly constant at 110 or 220, and when the losses of the
pressure coils at these voltages have once been calculated, the
necessary instrument correction can be readily made.]
On a three phase system the transformers should be joined in
delta connection, as a considerable advantage is thereby gained
over the star connection, in that should one of the transformers
become defective, the remaining two will carry the load without
change except more or less additional heating. Between the
transformers and rotary converter the circuits should be as short
and simple as possible, switches, fuses, and other instruments
being entirely excluded. The direct current from the converter is
led to the direct current switchboard, and from there distributed
to the feeder circuits.
=WATTMETER ERROR FOR A LOAD OF 1,000 VOLT-AMPERES=
(For a lag of 1 degree in the pressure coil)
+------------+----------+-------+-------------------+
| | | |Error of indication|
|Power factor|True watts| Error | in per cent |
| | | | of true value |
+------------+----------+-------+-------------------+
| 1. | 1,000 | .3 | 0.03 |
| .9 | 900 | 7.6 | 0.85 |
| .8 | 800 | 10.5 | 1.31 |
| .7 | 700 | 12.5 | 1.78 |
| .6 | 600 | 13.9 | 2.32 |
| .5 | 500 | 15.1 | 3.02 |
| .4 | 400 | 15.9 | 3.98 |
| .3 | 300 | 16.6 | 5.54 |
| .2 | 200 | 17.1 | 8.55 |
| .1 | 100 | 17.3 | 17.30 |
+------------+----------+-------+-------------------+
NOTE.--In the iron vane type instrument when
used as a wattmeter, the current of the series
coil always remains in perfect phase with
the current of the circuit, provided series
transformers are not introduced. The error,
then, is entirely due to the lag of the current
in the pressure coil, and this error in high
power factor is exceedingly small, increasing as
the power factor decreases. In the above table
it should be noted that the value of the error
as distinguished from the per cent. of error,
instead of indefinitely increasing as the power
factor diminishes, rapidly attains a maximum
value which is less than 2 per cent. of the power
delivered under the same current and without
inductance. It should also be noted that the
above tabulation is on the assumption of a lag of
1 degree in the pressure coil. The actual lag in
Wagner instruments for instance, is approximately
.085 of a degree, and the error due to the lag
of the pressure coil in Wagner instruments is,
therefore, proportionally reduced from the
figures shown in the above tabulation.
=Ques. In large sub-stations containing several rotary converters how
are they operated?=
Ans. Frequently they are installed to receive their respective
currents from the same set of bus bars; that is, they may be operated
as alternating current motors in parallel. They are also frequently
operated independently from single bus bars, but very seldom in
series with each other.
[Illustration: FIG. 2,880.--Single phase motor test. In this method
of measuring the input of a single phase motor of any type, the
ammeter, voltmeter and wattmeter are connected as shown in the
illustration. The ammeter measures the current flowing through the
motor, the voltmeter, the pressure across the terminals of the motor,
and the wattmeter the total power which flows through the motor
circuit. With the connections as shown, the wattmeter would also
measure the slight losses in the voltmeter and the pressure coil of
the wattmeter, but for motors of ¼ H.P. and larger, this loss is so
small that it may be neglected. The power factor may be calculated by
dividing the true watts as indicated by the wattmeter, by the product
of the volts and amperes.]
=Ques. How may the direct current circuit be connected?=
Ans. In parallel.
NOTE.--In motor testing, by the methods
illustrated in the accompanying cuts, it is
assumed that the motor is loaded in the ordinary
way by belting or direct connecting the motor
to some form of load, and that the object is to
determine whether the motor is over or under
loaded, and approximately what per cent. of full
load it is carrying. All commercial motors have
name plates, giving the rating of the motor and
the full load current in amperes. Hence the
per cent. of load carried can be determined
approximately by measuring the current input
and the voltage. If an efficiency test of the
apparatus be required, it becomes necessary to
use some form of absorption by dynamometer, such
as a Prony or other form of brake. The output of
the motor can then be determined from the brake
readings. The scope of the present treatment
is, however, too limited to go into the subject
of different methods of measuring the output of
the apparatus, and is confined rather to methods
of measuring current input, voltage, and watts.
The accuracy of all tests is obviously dependent
upon the accuracy of the instruments employed.
Before accepting the result obtained by any test,
especially under light or no load, correction
should be made for wattmeter error. See table of
wattmeter error on page 2,075.
[Illustration: FIG. 2,881.--Three phase motor test; voltmeter and
ammeter method. If it be desired to determine the approximate load
on a three phase motor, this may be done by means of the connections
as shown in the figure, and the current through one of the three
lines and the voltage across the phase measured. If the voltage be
approximately the rated voltage of the motor and the amperes the
rated current of the motor (as noted on the name plate) it may be
assumed that the motor is carrying approximately full load. If, on
the other hand, the amperes show much in excess of full load rating,
the motor is carrying an overload. The heat generated in the copper
varies as the square of the current. That generated in the iron
varies anywhere from the 1.6 power, to the square. This method is
very convenient if a wattmeter be not available, although, it is, of
course, of no value for the determination of the efficiency or power
factor of the apparatus. This method gives fairly accurate results,
providing the load on the three phases of the motor be fairly well
balanced. If there be much difference, however, in the voltage of
the three phases, the ammeter should be switched from one circuit to
another, and the current measured in each phase. If the motor be very
lightly loaded and the voltage of the different phases vary by 2 or 3
per cent., the current in the three legs of the circuit will vary 20
to 30 per cent.]
=Ques. What provision should be made against interruption of service
in sub-stations?=
Ans. There should be one reserve rotary converter to every three or
four converters actually required.
=Ques. Why does a rotary converter operate with greater efficiency,
and require less attention than does a dynamo of the same output?=
Ans. There is less friction, and less armature resistance, the
latter because the alternating current at certain portions of each
revolution passes directly to the commutator bars without traversing
the entire armature winding as it does in a dynamo; there is no
distortion of the field and consequently no sparking, or shifting of
the brushes, since the armature reaction resulting from the current
fed into the machine and that due to the current generated in the
armature completely neutralizes each other.
[Illustration: FIG. 2,882.--Three phase motor test by the two
wattmeter method. If an accurate test of a three phase motor be
required, it is necessary to use the method here indicated. Assume
the motor to be loaded with a brake so that its output can be
determined. This method gives correct results even with considerable
unbalancing in the voltages of the three phases. With the connections
as shown, the sum of the two wattmeter readings gives the total power
in the circuit. Neither meter by itself measures the power in any
one of the three phases. In fact, with light load one of the meters
will probably give a negative reading, and it will then be necessary
to either reverse its current or pressure leads in order that the
deflection may be noted. In such cases the algebraic sums of the two
readings must be taken. In, other words, if one read plus 500 watts
and the other, minus 300 watts, the total power in the circuit will
be 500 minus 300, or 200 watts. As the load comes on, the readings of
the instrument which gave the negative deflection will decrease until
the reading drops to zero, and it will then be necessary to again
reverse the pressure leads on this wattmeter. Thereafter the readings
of both instruments will be positive, and the numerical sum of the
two should be taken as the measurement of the load. If one set of the
instruments be removed from the circuit, the reading of the remaining
wattmeter will have no meaning. As stated above, it will not indicate
the power under these conditions in any one phase of the circuit. The
power factor is obtained by dividing the actual watts input by the
product of the average of the voltmeter readings × the average of the
ampere readings × 1.73.]
=What electrical difficulty is experienced with a rotary converter?=
Ans. Regulation of the direct current voltage.
=Ques. How is this done?=
Ans. It can be maintained constant only by preserving uniform
conditions of inductance in the alternating current circuit, and
uniform conditions in the alternator.
While changes in either of these may be compensated to a certain
extent by adjustment of the field strength of the converter, they
cannot be entirely neutralized in this manner; it is therefore
necessary that both the line circuit and the alternator be
given attention if the best results are to be obtained from the
converter.
=Ques. What mechanical difficulty is experienced with rotary
converters?=
Ans. Hunting.
=Ques. What is the cause of this?=
Ans. It is due to a variation in frequency.
The inertia of the converter armature tends to maintain a
constant speed; variations in the frequency of the supply circuit
will cause a displacement of phase between the current in the
armature and that in the line wires, which displacement, however,
the synchronizing current strives to decrease. The synchronizing
current, although beneficial in remedying the trouble after it
occurs, exerts but little effort in preventing it, and many
attempts have been made to devise a plan to eliminate this trouble.
NOTE.--Three phase motor test; polyphase
wattmeter method. This is identical with the test
of fig. 2,882, except that the wattmeter itself
combines the movement of the two wattmeters.
Otherwise the method of making the measurements
is identical. If the power factor be known to be
less than 50 per cent., connect one movement so
as to give a positive deflection; then disconnect
movement one and connect movement two so as to
give a positive deflection. Then reverse either
the pressure or current leads of the movement,
giving the smaller deflection, leaving the
remaining movement with the original connections.
The readings now obtained will be the correct
total watts delivered to the motor. If the power
factor be known to be over 50 per cent., the same
methods should be employed, except that both
movements should be independently connected to
give positive readings. An unloaded induction
motor has a power factor of less than 50 per
cent., and may, therefore, be used as above
for determining the correct connections. For a
better understanding of the reasons for the above
method of procedure, the explanation of the two
wattmeter method, fig. 2,882, should be read. The
power factor may be calculated as explained under
fig. 2,882. Connect as shown in fig 2,882. The
following check on connection may be made. Let
the polyphase induction motor run idle, that is,
with no load. The motor will then operate with a
power factor less than 50 per cent. The polyphase
meter should give a positive indication, but
if each movement be tried separately one will
be found to give a negative reading, the other
movement will give a positive reading. This can
be done by disconnecting one of the pressure
leads from the binding post of one movement. When
the power factor is above 50 per cent. then both
movements will give positive deflection.
=Ques. What are the methods employed to prevent hunting?=
Ans. 1, the employment of a strongly magnetized field relative to
that developed by the armature; 2, a heavy flywheel effect in the
converter; 3, the increasing of the inductance of the armature by
sinking the windings thereon in deep slots in the core, the slots
being provided with extended heads; and 4, the employment of damping
devices or amortisseur winding on the pole pieces of the converter.
[Illustration: FIG. 2,883.--Three phase motor test; one wattmeter
method. This method is equivalent to the two wattmeter method with
the following difference. A single voltmeter (as shown above) with
a switch, A, can be used to connect the voltmeter across either one
of the two phases. Three switches, B, C and D, are employed for
changing the connection of the ammeter and wattmeter in either one
of the two lines. With the switches B and D in the position shown,
the ammeter and wattmeter series coils are connected in the left hand
line. The switch C must be closed under these conditions in order to
have the middle line closed. Another reading should then be taken
before any change of load has occurred, with switch A thrown to the
right, switch B closed, switch D thrown to the right and switch C
opened. The ammeter and the current coil of the wattmeter will then
be connected to the middle line of the motor. In order to prevent
any interruption of the circuit, the switches B, D and C should be
operated in the order given above. With very light load on the motor
the wattmeter will probably give a negative deflection in one phase
or the other, and it will be necessary to reverse its connections
before taking the readings. For this purpose a double pole, double
throw switch is sometimes inserted in the circuit of the pressure
coil of the wattmeter so that the indications can be reversed
without disturbing any of the connections. It is suggested, before
undertaking this test, that the instructions for test by the two
wattmeter and by the polyphase wattmeter methods be read.]
=Ques. What method is the best?=
Ans. The damping method.
The devices employed for the purpose are usually copper shields
placed between or around the pole pieces, although in some
converters the copper is embedded in the poles, and in others it
is made simply to surround a portion of the pole tips.
In any case its action is as follows: The armature rotating at a
variable speed has a field developed therein which is assumed to
be also rotating at a variable speed; the magnetism of this rotary
field induces currents in the copper which, however, react on the
armature and oppose any tendency toward a further shifting of the
magnetism in the armature and therefore prevent the development
of additional currents in the copper. Since copper is of low
resistance, the induced currents are sufficient in strength to
thus dampen any tendency toward phase displacement, and so exert a
steadying influence upon the installation as a whole.
[Illustration: FIG. 2,884.--Three phase motor, one wattmeter and Y
box method. This method is of service, only, provided the voltages of
the three phases are the same. A slight variation of the voltage of
the different phases may cause a very large error in the readings of
the wattmeter, and inasmuch as the voltage of all commercial three
phase circuits is more or less unbalanced, this method is not to be
recommended for motor testing. With balanced voltage in all three
phases, the power is that indicated by the wattmeter, multiplied by
three. Power factor may be calculated as before.]
=Electrical Measuring Instruments.=--In the manufacture of most
measuring instruments, the graduations of the scale are made at the
factory, by comparing the deflections of the pointer with voltages
as measured on standard apparatus. The voltmeters in most common
use have capacities of 5, 15, 75, 150, 300, 500 and 750 volts each,
although in the measurement of very low resistances such as those of
armatures, heavy cables, or bus bars, voltmeters having capacities as
low as .02 volt are employed.
[Illustration: FIG. 2,885.--Test of three phase motor with neutral
brought out; single wattmeter method. Some star connected motors
have the connection brought out from the neutral of the winding. In
this case the circuit may be connected, as here shown. The voltmeter
now measures voltage between the neutral and one of the lines, and
the wattmeter the power in one of the three phases of the motor.
Therefore, the total power taken by the motor will be three times the
wattmeter readings. By this method, just as accurate results can be
obtained as with the two wattmeter method. The power factor will be
the indicated watts divided by the product of the indicated amperes
and volts.]
The difference between the design of direct current voltmeters of
different capacities lies simply in the high resistance joined in
series with the fine wire coil. This resistance is usually about 100
ohms per volt capacity of the meter, and is composed of fine silk
covered copper wire wound non-inductively on a wooden spool.
In the operation of an instrument, if the pointer when deflected do
not readily come to a position of rest owing to friction in the
moving parts, it may be aided in this respect by gently tapping
the case of the instrument with the hand; this will often enable
the obstruction, if not of a serious nature, to be overcome and an
accurate reading to be obtained.
[Illustration: FIG. 2,886.--Temperature test of a large three
phase induction motor. Temperature tests are usually made on small
induction motors by belting the motor to a generator and loading the
generator with a lamp bank or resistance until the motor input is
equal to the full load. If, however, the motor be of considerable
size, such that the cost of power becomes a considerable item in
the cost of testing, the method here shown may be employed. For
this purpose, however, two motors, preferably of the same size and
type, are required. One is driven as a motor and runs slightly below
synchronism, due to its slip when operating with load. This motor is
belted to a second machine. If the pulley of the second machine be
smaller than the pulley of the first machine, the second machine will
then operate as an induction generator, and will return to the line
as much power as the first motor draws from the line, less the losses
of the second machine. By properly selecting the ratio of pulleys,
the first machine can be caused to draw full load current and full
load energy from the line. In this way, the total energy consumed
is equivalent to the total of the losses of both machines, which is
approximately twice the losses of a single machine. The figure shows
the connection of the wattmeters, without necessary switches, for
reading the total energy by two wattmeter method. Detailed connection
of the wattmeter is shown in fig. 2,883. It is usual, in making
temperature tests, to insert one or more thermometers in what is
supposed to be the hottest part of the winding, one on the surface
of the laminae and one in the air duct between the iron laminae. The
test should be continued until the difference in temperature between
any part of the motor and the air reaches a steady value. The motor
should then be stopped and the temperature of the armature also
measured. For the method of testing wound armature type induction
motors of very large size, see fig. 2,890. For the approved way
of taking temperature readings and interpreting results, see the
"Standardization Rules of the A.I.E.E."]
=Ques. Describe a two scale voltmeter.=
Ans. In this type of instrument, one scale is for low voltage
readings and the other for high voltage readings; on these scales
the values of the graduations for low voltages are usually marked
with red figures, while those for high voltages are marked with
black figures. A voltmeter carrying two scales must also contain two
resistances in place of one; a terminal from each of these coils must
be connected with a separate binding post, but the remaining terminal
of each resistance is joined to a wire which connects through the
fine wire coil with the third binding post of the meter. The two
first mentioned binding posts are usually mounted at the left hand
side of the meter and the last mentioned binding post and key at the
right hand side.
[Illustration: FIG. 2,887.--Alternator excitation or magnetization
curve test. The object of this test is to determine the change of
the armature voltage due to the variation of the field current when
the external circuit is kept open. As here shown, the field circuit
is connected with an ammeter and an adjustable resistance in series
with a direct current source of supply. The adjustable resistance is
varied, and readings of the voltmeter across the armature, and of
the ammeter, are recorded. The speed of the generator must be kept
constant, preferably at the speed which is given on the name plate.
The excitation or magnetization curve of the machine is obtained by
plotting the current and the voltage.]
The resistance corresponding to the high reading scale is
composed of copper wire having the same diameter as that
constituting the resistance for the low reading scale, but as the
capacity of the former scale is generally a whole number of times
greater than that of the latter scale, the resistances for the two
must bear the same proportion.
[Illustration: FIG. 2,888.--Three phase alternator synchronous
impedance test. In determining the regulation of an alternator, it
is necessary to obtain what is called the _synchronous impedance_ of
the machine. To obtain this, the field is connected, as shown above.
Voltmeters are removed and the armature short circuited with the
ammeters in circuit. The field current is then varied, the armature
driven at synchronous speed, and the armature current measured by
the ammeters in circuit. The relation between field and armature
amperes are then plotted. The combination of the results of this
test, with those obtained from the test shown in fig. 2,887, are used
in the determination of the regulation of an alternator. Engineers
differ widely in the application of the above to the determination
of regulation, and employ many empirical formulae and constants for
different lines of design.]
=Ques. How is a two scale voltmeter connected?=
Ans. In the connection of a two scale voltmeter in circuit, the
single binding post is always employed regardless of which scale is
desired. If, then, the voltage be such that it may be measured on the
low reading scale, the other binding post employed is that connected
to the lower of the two resistances contained within; if, however,
the pressure be higher than those recorded on the low reading scale,
the binding post connected to the higher of the two resistances
contained within is used.
NOTE.--Three phase alternator load test. By
means of the connection shown in fig. 2,888,
readings of armature current and field amperes
can be obtained with any desired load. The field
current can be varied also so as to maintain
constant armature voltage irrespective of load;
or the field current may be kept constant and
the armature voltage allowed to vary as the load
increases. The connections may also be used to
make a temperature test on the alternator by
loading it with an artificial load. In some cases
after the alternator is installed the connection
may be used to make a temperature test, using
the actual commercial load the alternator is
furnishing.
Inasmuch as the capacities of the scales are
usually marked on or near the corresponding
binding posts, there will generally be no
difficulty in selecting the proper one of the two
left hand binding posts.
[Illustration: FIG. 2,889.--Three phase alternator or synchronous
motor temperature test. In this test two alternators or synchronous
motors of same size and type are used, and are belted together, one
to be driven as a synchronous motor and the other as an alternator.
The method employed is to synchronize the synchronous motor with
the alternator or alternators on the three phase circuit, and then
connect to the line by means of a three pole single throw switch.
The alternator is then similarly synchronized with the alternator
of the three phase circuit and thrown onto the line. By varying the
field of the alternator it can be made to carry approximately full
load, and the motor will then be also approximately fully loaded.
The usual method is to have the motor carry slightly in excess of
full load, and the alternator slightly less than full load. Under
these conditions the motor will run a little warmer than it should
with normal load, while the alternator will run slightly cooler.
Temperature measurements are made in the same way as discussed
under three phase motors. The necessary ammeters, voltmeters and
wattmeters for adjusting the loads on the motors and generator are
shown in above figure. If pulleys be of sufficient size to transmit
the full load, with, say one per cent. slip, the pulley on the motor
should be one per cent. larger in diameter than the pulley on the
alternator, so as to enable the alternator to remain in synchronism
and at the same time deliver power to the circuit. With very large
machines under test, it is inadvisable to use the above method as
it is sometimes difficult to so adjust the pulleys and belt tension
that the belt slip will be just right to make up for the difference
in diameter of the pulleys, and very violent flapping of the belt
results. To meet such cases, various other methods have been devised.
One which gives consistent results is shown in fig. 2,890.]
=Ques. How is a two scale voltmeter connected when the binding posts
are not marked?=
Ans. If only an approximate idea is possessed of the voltage to be
measured, it is always advisable to connect to the binding post
corresponding to the high reading scale of the meter in order
to determine if the measurement may not be made safely and more
accurately on the low reading scale. In any case, some knowledge must
be had of the voltage at hand, else the high reading portion of the
instrument may be endangered.
[Illustration: FIG. 2,890.--Three phase alternator or synchronous
motor temperature test. Supply the field with normal field current.
The armature is connected in open delta as illustrated, and full load
current sent through it from an external source of direct current,
care being taken to ground one terminal of the dynamo so as to avoid
danger of shock due to the voltage on the armature winding. The field
is then driven at synchronous speed. If the armature be designed to
be connected star for 2,300 volts, the voltage generated in each leg
of the delta will be 1,330 volts, and unless one leg of the dynamo
were grounded, the tester might receive a severe shock by coming
in contact with the direct current circuit. The insulation of the
dynamo would also be subjected to abnormal strain unless one terminal
were grounded. By the above method the field is subjected to its
full copper loss and the armature to full copper loss and core loss.
Temperature readings are taken as per standardization rules of the
A.I.E.E. This method may also be used with satisfactory results on
large three phase motors of the wound rotor type. If the alternator
pressure be above 600 volts, a pressure transformer should be used in
connection with the voltmeter.]
_Too much care cannot be taken to observe these precautions_
whenever the voltmeter is used, for the burning out or charring
of the insulation either in the fine wire coil or in the high
resistance of the meter by an excessive current, is one of the
most serious accidents that can befall the instrument.
If a voltmeter has been subjected to a voltage higher than that
for which it was designed, yet not sufficiently high to injure the
insulation, but high enough to cause the pointer to pass rapidly
over the entire scale, damage has been done in another way. The
pointer being forced against the side of the case in this manner,
bends it more or less and so introduces an error in the readings
that are afterward taken.
The same damage will be done if the meter be connected in
circuit so the current does not pass through it in the proper
direction, although in this case the pointer is not liable to
be bent so much as when it is forced to the opposite side of
the meter by an abnormal current, since then it has gained
considerable momentum which causes a severer impact. The extent
of the damage may be ascertained by noting how far away from the
zero mark the pointer lies when no current is passing through
the instrument. If this distance be more than two-tenths of a
division, the metal case enclosing the working part should be
removed and the pointer straightened by the careful use of a pair
of pinchers.
[Illustration: FIG. 2,891.--Direct motor or dynamo magnetization
test. The object of this test is to determine the variation of
armature voltage without load, with the current flowing through the
field circuit. The armature should be driven at normal speed. The
adjustment resistance in the field circuit is varied and the voltage
across the armature measured. The curve obtained by plotting these
two figures is usually called magnetization curve of the dynamo. It
is usual to start with the higher resistance in the field circuit so
that very small current flows, gradually increasing this current by
cutting out the field resistance. When the highest no load voltage
required is reached, the field current is then diminished, and what
is called the descending (as opposed to the ascending) magnetization
curves are obtained. The difference in the two curves is due to the
lag of the magnetization behind the magnetizing current, and is
caused by the hysteresis of the iron of the armature core.]
=Ques. What should be noted with respect to location of instruments?=
Ans. If they be placed near conductors carrying large currents,
the magnetic field developed thereby will produce a change in the
magnetism of the instruments and so introduce an error in the
readings.
[Illustration: FIG. 2,892.--Shunt dynamo external characteristic
test. The external characteristic of a shunt dynamo is a curve
showing the relation between the current and voltage of the external
circuit. This is obtained by the connection as here shown. The shunt
field is so adjusted that the machine gives normal voltage when
the external circuit is open. The field current is then maintained
constant and the external current varied by varying the resistance
in the circuit. By plotting voltage along the vertical, against the
corresponding amperes represented along the horizontal, the external
characteristic is obtained.]
=Ques. How should portable instruments be wired?=
Ans. The wires must be firmly secured to the supports on which they
rest, so as to reduce the possibility of their being pulled by
accident, and so causing the instruments to fall.
A fall or a rough handling of the meter at once shows its effect
on the readings, for as much harm is done as would result from a
similar treatment of a watch.
The hardened steel pivots used in all high grade voltmeters are
ground and polished with extreme care so as to secure and maintain
a high degree of sensitiveness. The jewels on which the moving
parts revolve are of sapphire, and they too must necessarily be
made with skill and carefulness; if, therefore, the jewels become
cracked and the pivots dulled by careless handling, the meter at
once becomes useless as a measuring instrument.
=Ques. How should readings be taken?=
Ans. The deflection of the pointer should be read to tenths of a
division; this can be done with considerable accuracy, especially
after a little practice.
[Illustration: FIG. 2,893.--Load and speed test of direct current
shunt motor. The object of this test is to maintain the voltage
applied to the motor constant, and to vary the load by means of a
brake and find the corresponding variation in speed of the machine
and the current drawn from the circuit. If the motor be a constant
speed motor, the field resistance is maintained constant. The above
indicates the method of connecting instruments for the test alone;
for starting the machine the ordinary starting box, should, of
course, be inserted.]
For very accurate results, a temperature correction should be
applied to compensate the effect which the temperature of the
atmosphere has upon the resistance of the meter when measurements
are being taken. In ordinary station practice the temperature
correction is negligible, being for resistance corresponding to
the high scale in first class meters, less than one-quarter of 1
per cent. for a range of 35 degrees above or 35 degrees below 70
degrees Fahrenheit.
=Ques. What attachment is sometimes provided on station voltmeters
used for constant pressure service?=
Ans. A normal index.
[Illustration: FIG. 2,894.--Temperature test of direct current
motor or dynamo; loading back method. In making temperature tests
on a small dynamo it is usual to drive the dynamo with a motor and
load the dynamo by means of a lamp bank or resistance, the voltage
across the dynamo being maintained constant, and the current through
the external circuit adjusted to full load value. The temperatures
are then recorded, and when they reach a constant value above the
temperature of the atmosphere, the test is discontinued. Similarly,
in making a test on a small motor, the motor is loaded with a dynamo
and the load increased until the input current reaches the normal
full load value of the motor, the test being conducted as for a small
dynamo. When, however, the apparatus, either motor or dynamo, reaches
a certain size, it becomes necessary, in order to economize energy,
to use what is called the =loading back method=, as here illustrated.
The motor is started in the usual way, with the dynamo belted to it,
the circuit of the dynamo being open. The field of the dynamo is then
adjusted so that the dynamo voltage is equal to that of the line.
The dynamo is then connected to the circuit and its field resistance
varied until it carries normal full load current. Under these
conditions, if the motor and dynamo be of the same size and type,
the motor will carry slightly in excess of full load, the difference
being approximately twice the losses of the machines. Under these
conditions the total power drawn from the line is equal to twice the
loss of either machine. Temperature readings are taken as in other
temperature tests.]
=Ques. What precaution must be taken in connecting station
voltmeters?=
Ans. Care must be taken to guard against any short circuiting of the
voltmeter, which, would mean a short circuiting of the generator, and
as a result the probable burning out of its armature.
The high resistance of the voltmeter prevents any such
occurrence when it is connected in the proper way, but should one
side of the circuit be grounded to the metal case or frame of the
meter, a careless handling of the lead connected with the other
side of the circuit would produce the result just mentioned.
[Illustration: FIG. 2,895.--Compound dynamo external characteristics
test; adjustable load. The object of this test is to determine the
relation between armature voltage and armature current. Shunt field
is adjusted to give normal secondary voltage when the external
circuit is open. The load is then applied by means of an adjustable
resistance or lamp bank, and readings of external voltage and current
recorded. If the machine be normally compounded, the external voltage
will remain practically constant throughout the load range. If the
machine be under-compounded, the external voltage will drop with
load, while if over-compounded, there will be a rise in voltage with
increase in load.]
=Ques. Why do station voltmeters indicate a voltage slightly lower
than actually exists across the leads?=
Ans. Since they are usually connected permanently in circuit; a
certain amount of heat is developed in the wiring of the instrument.
[Illustration: FIGS. 2,896 and 2,897.--Transformer core loss and
leakage, or exciting current test. With the primary circuit open,
the ammeter indicates the exciting or no load current. It should
be noted that all instruments are inserted on the low voltage
side, for both safety of the operator and because the measurements
are more accurate. The no load primary current, if the ratio of
transformation be 10: 1, will be one-tenth of the measured secondary
current. The wattmeter connected, as shown, measures the sum of the
losses, in the transformer, in the pressure coil of the wattmeter,
and in the voltmeter. On all standard makes of portable instruments,
the resistance of the wattmeter pressure coil and of the voltmeter
is given, and the loss in either instrument is the square of the
voltage at its terminals, divided by its resistance. Subtracting
these losses from the total indicated upon the wattmeter, gives the
true core or iron loss. It should be noted that in this diagram is
shown an auxiliary transformer with a number of taps for obtaining
the exact rated voltage of the transformer under test. In fig. 2,897
is shown, in general, the same connections as in fig. 2,896, except
that the auto-transformer has been replaced by a resistance. If the
line voltage available be not much in excess of the rated voltage of
the transformer under test, very little error is introduced by the
use of the resistance method. However, if the difference be 10 per
cent. or more the auxiliary transformer shown in fig. 2,896 should be
used. Measurements made under the resistance method always give lower
results than those obtained with the auxiliary transformer.]
The effect of this heat increases the voltmeter resistance and
consequently reduces the current below that which otherwise would
pass through the meter; since the deflections of the pointer
are governed by the strength of the current, station voltmeters
invariably indicate a voltage slightly lower than that which
actually exists across their leads.
[Illustration: FIG. 2,898.--Diagram of connections for calibrating a
wattmeter. The calibration of a portable wattmeter is accomplished
with direct current of constant value which is passed through the
series winding by connecting the source thereof with the current
terminals. A direct current voltage which may be varied throughout
the range of the wattmeter is also applied to the instrument
between the middle and right hand pressure terminals A and E the
wiring in the meter between these terminals being such that its
differential winding is then cut out of circuit. The method of
procedure consists in comparing the deflections on the wattmeter at
five of six approximately equidistant points over its scale with the
corresponding products of volts and amperes used to obtain them. The
changes in the wattmeter deflections are effected by merely varying
the voltage, the value of the current being maintained constant at a
value which represents the full current capacity of the meter.]
NOTE.--=Checking up of a recording wattmeter.=
This may conveniently be done by noting the
deflections at short intervals on an ammeter
connected in circuit, and also the readings
on the dial of the recording wattmeter during
this period. If this test be continued for an
appreciable time, the product of the pressure
in volts, the current in amperes, and the time
in hours, should equal the number of watthours
recorded on the counters of the dial.
NOTE.--=Transformer testing.= In the early
days of transformer building, before the
commercial wattmeter had been perfected, leakage
or exciting current was the criterion of good
design. After the introduction of the wattmeter,
core loss became the all important factor, and
for a long time the question of leakage current
was lost sight of. With the introduction of
silicon steel, leakage or exciting current again
assumed prominence. Keeping in mind the fact
that all characteristics of a transformer are of
more or less importance, it is essential that
the user of such apparatus have at hand the
necessary facilities for making tests of all such
variable quantities. The tests which all users
of transformers should make, are given in this
chapter.
=Ques. Can direct current be measured by an alternating current
voltmeter?=
Ans. Yes.
[Illustration: FIG. 2,899.--Transformer copper loss by wattmeter
measurement and impedance. At first glance, this method would
seem better than the calculation of loss after measurement of the
resistance. However, it should be noted that the wattmeter is, in
itself, subject to considerable error under the low power factor
that will exist in this test. The secondary of the transformer is
short circuited, and a voltage applied to the primary which is just
sufficient to cause full load primary current. If full current pass
through the primary of the transformer with the secondary short
circuited, the secondary will also carry full load current. With
connections as shown, and with the full load current, the voltmeter
indicates the impedance volts of the transformer. This divided by
the rated voltage gives what is called the _per cent. impedance of
the transformer_. In a commercial transformer of 5 kw., this should
be approximately 3 per cent. The iron loss of the transformer under
approximately 3 per cent. of the normal voltage will be negligible,
and the losses measured will be the sum of the primary and secondary
copper losses. As in the discussion of the core loss measurements,
the wattmeter readings must be corrected for the loss in its pressure
coil, the method of correction being the same as that discussed under
the core loss measurement. If the impedance volts, as measured, be
divided by the primary current, the impedance of the transformer
is obtained. The reciprocal of this quantity is known by the term
"admittance." _When two or more transformers are connected in
parallel they divide the load in proportion to their admittance._
It is, therefore, important that the users of transformers know the
impedance of the apparatus used, in order to determine whether two
or more transformers will operate satisfactorily in parallel. For
discussion of wattmeter error on low power factor, see note on page
2,075. For accurate measurement of impedance, the voltmeter should
be connected directly across the terminals of the transformer rather
than as shown in the diagram.]
NOTE.--=Transformer copper loss test.= The
usual and best method of obtaining copper
losses is to separately measure the primary and
secondary resistance and calculate from these
the primary and secondary copper losses. For
general diagram of connections and discussion
of the drop method, see fig. 2,875. The current
should be kept well within the load current of
the transformer to avoid temperature rise during
the test. In other words, the resistance of the
coil is the voltage across its terminals divided
by the current. The resistance of the primary
coil can be measured similarly. The copper loss
in watts in each coil will then be the product
of the resistance and the square of the rated
current for that coil. The total copper loss will
be the sum.
=Ques. What would be the effect of placing a direct voltmeter across
an alternating current circuit, and why?=
Ans. There would be no deflection of the pointer owing to the rapid
reversals of the alternating current.
=Ques. What are the usual capacities of alternating current
voltmeters?=
Ans. They are 3, 7.5, 10, 12, 15, 20, 60, 75, 120, 150, 300 and 600
volts, but these capacities may each be increased by the use of a
multiplier.
[Illustration: FIG. 2,900.--Temperature test of transformer with
non-inductive load. The figure shows the simplest way of making the
test. Connect the primary of the transformer to the line as shown,
and carry normal secondary load by means of a bank of lamps or other
suitable resistance, until full load secondary current is shown by
the ammeter in the secondary circuit. The transformer should then be
allowed to run at its rated load for the desired interval of time,
temperature readings being made of the oil in its hottest part, and
also of the surrounding air. Where temperatures of the coil rather
than temperatures of the oil are desired, it is necessary to use the
resistance method. This is obtained by first carefully measuring the
resistance of both primary and secondary coils at the temperature
of the room, and then, after the transformer has been under heat
test for the desired time, disconnect it from the circuit and again
measure the resistance of primary and secondary. For proper method
of calculating the temperature rise from resistance measurements,
the reader is referred to the standardization rules of the A.I.E.E.
In making resistance measurements of large transformers by the drop
method care should be taken to allow both ammeter and voltmeter
indications to settle down to steady values before readings are
taken. This may require several minutes. Each time the current is
changed it is necessary in order to obtain check values on resistance
measurements, to wait until the current is again settled to its
permanent value before taking readings. All resistance measurements
must be taken with great care, as small errors in the measurement of
the resistance may make very large errors in the determination of
the temperature rise. The method above described is satisfactory for
small transformers. Where large units are to be tested, the cost of
current for testing becomes an important item. The "bucking test" as
in fig. 2,901, is more economical.]
=Ques. How are station voltmeters usually attached to the
switchboard?=
Ans. They are usually bolted to the switchboard by means of four
iron supports mounted on the back of the instrument; two of these are
fastened near each side of the case.
Under certain conditions, however, as in paralleling of
alternators, it is convenient to have the alternating current
voltmeter mounted on a swinging bracket at the side of the
switchboard. The voltmeter may then be swung around in any desired
direction so as to enable the attendant to keep informed of the
voltage while switching in each additional alternator.
[Illustration: FIG. 2,901.--Transformer temperature "bucking test."
For this purpose two transformers of the same size and ratio are
required. The connections are as shown. Full secondary voltage is
applied, and rheostats or auxiliary auto-transformers are inserted
in the circuit to properly regulate the voltage. The primaries
are connected with one bucking the other, and a voltage equal to
twice the impedance voltage of either transformer inserted in the
primary circuit. It should be noted that when the secondaries are
subjected to the full secondary voltage, a full primary voltage
exists across either primary, but with the primaries connected so
that the voltage of one is bucked against the voltage of the other,
the resultant voltage in the circuit will be zero. By applying to the
primary circuit twice the impedance voltage of either transformer,
full primary and secondary current will circulate through both
transformers. On the other hand, by subjecting the secondaries to
the full secondary voltage, the iron of the transformer will be
magnetized as under its regular operating conditions, and the full
iron loss of the transformer introduced. This method permits the
operation of two transformers under temperature test with their
full losses, without taking energy from the line equal to the rated
capacity. Measurements of temperature are taken in exactly the
same way as above. This method is successfully employed for making
temperature tests on transformers of all sizes.]
=Ques. How should an ammeter be operated to get accurate readings,
and why?=
Ans. It should be cut out of circuit except while taking a reading,
because of the error introduced by the heating effect of the current.
[Illustration: FIG. 2,902.--Transformer insulation test. In applying
a 10,000 volt insulation test between the primary and secondary of
a transformer, the testing leads should be disconnected from the
transformer under test, and a spark gap introduced as shown, with the
test needle set at a proper sparking distance for 10,000 volts. A
high resistance should be connected in the secondary before closing
its circuit, and the voltage gradually increased by cutting out
this secondary resistance until a spark jumps across the spark gap.
When the spark jumps across the spark gap, the voltmeter reading
should be recorded and the testing transformer disconnected. The
spark gap should then be increased about 10 per cent. and the high
tension leads connected to the transformer under test as indicated
in the diagram. In order to equalize the insulation strains, all
primary leads should be connected together, all secondary leads not
only connected together, but to the core as well. All resistance
in the rheostat in the low tension circuit should then be inserted
and the switch closed. Gradually cut out secondary resistance until
the voltmeter shows the same voltage as was recorded previously
when the spark jumped across the gap, and apply this voltage to the
transformer for one minute. Insulation tests for a period of over
one minute are very unadvisable, as transformers with excellent
insulation may be seriously damaged by prolonged insulation tests.
The longer the strain to which any insulation is subjected, the
shorter the subsequent life of the insulation. Also the greater the
applied voltage above the actual operating voltage of the apparatus,
the shorter the subsequent life of the insulation. In testing small
transformers, the spark gap may be omitted and the voltage of the low
pressure coil of the testing transformer measured. This multiplied by
the ratio of transformation gives the testing voltage.]
In an ammeter having a capacity of 50 amperes, the error thus
introduced will be less than 1 per cent. if connected continuously
in circuit with a current not exceeding three-quarters this
capacity.
An ammeter of 100 amperes capacity may be used indefinitely
in circuit with less than 1 per cent. error up to one-half its
capacity, and for five minutes at three-quarters capacity without
exceeding the 1 per cent. limit.
[Illustration: FIG. 2,903.--Transformer insulation test as made
when a special high tension transformer be not available. In this
method a number of standard transformers, connected as shown may be
employed, but great care should be taken to have such transformer
cases thoroughly insulated from the ground and from one another, in
order to minimize the insulation strains in the testing transformers.
Care should be taken to insert in the circuit of each testing
transformer a fuse, not in excess of the transformer capacity, which
will blow, in case of a break down in the apparatus under test.
In testing insulation between secondary and core, disconnect the
primary entirely, apply one terminal of the testing transformer to
the secondary terminals of the transformer under test, and the other
terminal of the testing transformer to the core of the transformer
under test. This test should also not be in excess of one minute.]
The 150 scale ammeter may be left in circuit for an indefinite
length of time at one-third its full capacity, and for three
minutes at one-half its full capacity, with a negligible error.
Ammeters of 200 and of 300 ampere capacities must not
continuously carry more than one-quarter of these loads
respectively if the readings are to have an accuracy within 1 per
cent. nor more than one-half these respective number of amperes
for three minutes if the same degree of accuracy be desired.
In order to cut or shunt the ammeter out of circuit when not
in use, it is customary when wiring the instrument in place, to
introduce a switch as a shunt across it; this switch is kept
closed except when a measurement is being taken.
When currents larger than 300 amperes have to be measured,
ammeter shunts are generally employed, although ammeters up to
500 amperes capacity are manufactured.
[Illustration: FIG. 2,904.--Transformer internal insulation test,
sometimes called double normal voltage test, from the fact that most
transformers are tested with double normal voltage across their
terminals. If either the primary or secondary of the transformer
be connected to some source of current with voltage double that of
the voltage of the transformer under test, the insulation between
adjacent turns, and also the insulation between adjacent layers
will be subjected to twice the normal operating voltage. It is good
practice to employ high frequency for this test in order to prevent
an abnormal current from passing through the transformer. Sixty
cycle transformers are usually tested on 133 cycles, and 25 cycle
transformers on 60 cycle circuits for this double normal voltage
test. It is necessary to insert the resistance in the circuit of the
transformer and bring the voltage up gradually, the same as applying
other high insulation tests in order to prevent abnormal rises in
pressure at the instant of closing the circuit.]
=Ques. What is used in place of instrument shunts for high pressure
alternating current measurements?=
Ans. Instrument transformers.
=Ques. What important attention should be periodically given to
measuring instruments?=
Ans. They should be frequently tested by comparison with standards
that are known to be correct.
Electrical measuring instruments, owing to the nature of their
construction and the conditions under which they must necessarily
be used, are subject to variations in accuracy. This feature is an
annoying one on account of the difficulty of detecting it; a meter
may, as far as appearances go, be in excellent working order and
yet give readings which are not to be relied upon.
Ridiculous as it may appear, the average station attendant
may frequently be seen straining his eyes to read to tenths of
a division on the scale of a meter which, if subjected to test,
would show an inaccuracy of over 2 per cent.
In testing a meter, by comparing it with a standard, in order to
obtain the best results there should be one man at each meter so
that simultaneous readings may be taken on both instruments, and
the man at the standard meter should maintain the voltage constant
while a reading is being taken, by means of a rheostat in the
field circuit of the generator supplying the current.
[Illustration: FIG. 2,905.--Transformer insulation resistance
test. The insulation, besides being able to resist puncture, due
to increased voltage, must also have sufficient resistance to
prevent any appreciable amount of current flowing between primary
and secondary coils. It is, therefore, sometimes important that the
insulation resistance between primary and secondary be measured. This
can be done, as here shown. Great care should be taken to have all
wires thoroughly insulated from the ground, and to have an ammeter
placed as near as possible to the terminals of the transformer under
test, in order that current leaking from one side of the line to the
other, external to the transformer, may not be measured. Great care
is required in making this measurement, in order to obtain consistent
results.]
Each meter should be checked or calibrated at five or six
approximately equidistant points over its scale; the adjustable
resistance being varied each time to give a deflection on the
standard meter of an even number of divisions and the deflection
on the other meter recorded at whatever it may be. Having obtained
the necessary readings, the calculation of the constant or
multiplying factor of the meter undergoing test is next in order.
This may best be shown by taking an actual case in which a 150
scale voltmeter is being tested to determine its accuracy. The
data and calculations are as follows:
Readings on Readings on Constant
standard meter meter tested
150 149.2 150 ÷ 149.2 = 1.005
125 125.0 125 ÷ 125.0 = 1.000
100 98.9 100 ÷ 98.9 = 1.011
75 73.6 75 ÷ 73.6 = 1.019
50 50.0 50 ÷ 50.0 = 1.000
25 24.8 25 ÷ 24.8 = 1.008
------
6.043
Average constant for six readings, 6.043 ÷ 6 = 1.007.
[Illustration: FIG. 2,906.--Transformer winding or ratio test. The
object of this test is to check the ratio between the primary and
the secondary windings. For this purpose a transformer of known
ratio is used as a standard. Connect the transformer under test with
a standard transformer as shown. Leave switch S_{2} open. With the
single pole double throw switch in position S_{1}B, the voltmeter
is thrown across the terminals of the standard transformer. With
the switch in position S_{1}A, the voltmeter is thrown across the
terminals of the transformer under test. The voltmeter should be read
with the switch in each position. If the winding ratio be the same as
that of the standard transformer, the two voltmeter readings will be
identical.]
It may be stated in general that before taking the readings for
this test, the zero position of the pointer on the meter tested
should be noted, and if it be more than two-tenths of a division
off the zero mark, the case of the meter should be removed and the
pointer straightened.
Furthermore, it will be noticed from the readings here recorded
that the test is started at the high reading end of the scale;
this is done in order that the pointer may gradually be brought
up to this spot, by slowly cutting out of circuit the adjustable
resistance, and thus show whether or not the pointer has a
tendency to stick at any part of the scale. If the meter seem to
be defective in this respect, it should be remedied either by
bending the pointer or scale, or by renewing one or both of the
jewels, before the comparison with the standard is commenced.
It is obvious from the readings recorded for the 150 scale
voltmeter, that as compared with the corresponding deflections of
the standard, the former are a trifle low.
In order to determine for each observation how much too low
they are, it is necessary to divide each reading on the standard
by the corresponding reading on the meter tested. The result is
the amount by which a deflection of this size on the meter tested
must be multiplied in order to obtain the exact reading. This
multiplier is called a constant, and as shown, a constant is
determined for each of the six observations.
The average constant for the six readings is then found, and
this is taken as the constant for the meter as a whole; that is,
whenever this 150-scale voltmeter is used, each reading taken
thereon must be multiplied by 1.007 in order to correct for its
inaccuracy.
The most convenient and systematic way of registering the
constant of a meter is to write it, together with the number of
the meter and the date of its calibration, in ink on a cardboard
tag and loop the same by means of a string to the handle or some
other convenient part of the meter.
NOTE.--=Transformer polarity test.= A test of
importance in the manufacture of transformers,
and sometimes necessary for the user, is the
so called _banking_ or _polarity_ test. The
transformers from any particular manufacturer
have the leads brought out in such a manner that
a transformer of any size can be connected to
primary and secondary lines in a given order
without danger of blowing the fuses due to
incorrect connections. All manufacturers of
transformers, however, do not bank transformers
in the same way, so that it is necessary in
placing transformers of different makes to test
for polarity. This is done as shown in fig.
2,906. One transformer is selected as a standard
and the leads of the second transformer connected
as indicated in the diagram. If the transformers
be 1,100-2,200 volts to 110-220, two 110 volt
lamps are connected in the secondaries of the
transformers as indicated, while the primary of
the transformer is connected across the line.
In transformers built for two primary and two
secondary voltages, it is necessary to test each
primary and each secondary. The diagram shows the
method of connecting one 2,200 volt coil and one
110 volt coil to the transformer to be tested.
When the primary circuit of the transformer under
test is closed, and if the secondary leads of
the 110 volt coil under test be brought out of
the case properly, the two 110 volt lamps should
be brightly illuminated. If, on the other hand,
the two 110 volt terminals have been reversed,
no current will flow through the lamps. If
these two terminals be found to be brought out
correctly, transfer the secondary leads of the
transformer under test to the second 110 volt
coil. Upon closing the primary circuit, the lamp
should again be brightly illuminated. Repeat this
process with each of the secondary coils and the
other primary coil, and if the lamps show up
brightly in every case on closing the primary
circuit, all leads have been properly brought
out. If on any tests the lamps do not light up
brightly, the leads on the transformer must be so
changed as to produce the proper banking.
=Ques. What are the usual remedies applied to a voltmeter to correct
a 3 or 4 per cent. error?=
Ans. They consist of straightening the pointer, varying the tension
of the spiral springs, renewing the jewels in the bearings, altering
the value of the high resistance, and, in the case of a direct
current instrument, strengthening the permanent magnet.
=Ques. How is the permanent magnet strengthened?=
Ans. After detaching it from the instrument, wrap around several
turns of insulated wire, and pass through this wire for a short time
3 or 4 amperes of direct current in such a direction as to reinforce
the magnet magnetism.
=Ques. How may the value of the high resistance of a voltmeter be
altered?=
Ans. Determine the resistance of the voltmeter and add or subtract,
according as the reading is high or low, a certain length of wire
whose resistance is in per cent. of the voltmeter resistance the same
as the per cent. of error.
NOTE.--The complete calibration of a two
scale voltmeter does not, as might be supposed,
necessitate that the readings on both scales be
checked with standards, for since the resistance
corresponding to the one scale is always some
multiple of the resistance of the other, the
constants of the two scales are proportional. For
instance, if S = the reading at the end of the
high scale of the voltmeter; S^{1} = the reading
at the end of the low scale of the voltmeter; R =
the resistance in the meter corresponding to the
high scale; R^{1} = the resistance in the meter
corresponding to the low scale; K = the constant
for the high scale, and K^{1} = the constant for
the low scale. Then
SK ÷ R = S^{1}K^{1} ÷ R^{1}
from which
K^{1} = SKR ÷ S^{1}R
That is to say, if the respective resistances corresponding to
the two scales be known, and the constant of the high scale be
determined by comparison with a standard, then by aid of these
known values and the maximum readings on the two scales, the
constant of the low scale may be calculated. It is also possible
to calculate the constant of the high scale if the constant of the
low scale be known, together with the values of the resistances
corresponding to the two scales; for from the equation previously
given.
K = RS^{1}K^{1} ÷ R^{1}S
=Ques. What is a frequent cause of error in an alternating current
meter, and why?=
Ans. The deterioration of its insulation, which permits the working
parts of the instrument coming in contact with the surrounding metal
case.
A convenient method of testing for deterioration of insulation
is shown in fig. 2,905.
[Illustration: FIG. 2,907.--Diagrams showing various synchronous
converter transformer connections. The diametrical connection is
used most frequently as it requires only one secondary coil on each
transformer, this being connected to diametrically opposite points on
the armature winding. The middle points can be connected together and
a neutral obtained the unbalanced three wire direct current having no
distorting effect. With diametrical secondaries, the primaries should
preferably be connected delta, except with regulating pole converters
where they must be connected Y. Diametrical secondaries with delta
primaries should not be used with regulating pole converters. Double
star connection of secondaries may, however, be used with delta
primaries, and is free from the trouble of the triple harmonic of the
transformer appearing in the primary. In this case, however, the two
secondary neutrals must not be connected with each other.]
=How to Test Generators.=--In the operation of electrical stations,
many problems dealing with the generators installed therein can be
readily solved by the aid of characteristic curves, which bear a
relation to the generators similarly as do indicator diagrams to
steam engines.
[Illustration: FIG. 2,908.--General form of characteristic curves
for a series dynamo. The general curve that may be expected is OA.
It is obtained practically in the same manner as for the shunt
characteristic curve, except that no field rheostat is employed.
Commencing with no load or amperes, there will probably be a
small deflection noticeable on the voltmeter, due to the residual
magnetism. The other readings are taken with successive reductions
of main current resistance. The curve OA thus obtained for a certain
series generator is practically a straight line at the beginning,
representing thereby a proportional increase of voltage with
increase of current, but after a certain current is reached (about
20 amperes in this case) the curve flattens and takes a downward
direction. The turning point occurs in the characteristic curves
of all series generators, and it denotes the stage at which the
iron magnet cores become so saturated with lines of magnetic force
that they will not readily allow more to pass through them; this
turning point is technically known as the point of saturation, and
the current corresponding (20 amperes in this case) is called the
critical current of the dynamo. The point of saturation in any given
series machine is governed by the amount of iron in the magnetic
circuit; its position in the curve therefore varies according to
the design of the generator as does also the critical current. The
value of the latter is important inasmuch as the valuable features
of a series generator assert themselves only when the machine is
supplying a greater number of amperes than that of the critical
current, for if the series generator be worked along that part M A of
the curve to the right of the point of saturation it becomes nearly
self-regulating as regards current, because as the current increases
the voltage drops. In the diagram in addition to the characteristic
curve O A, which may more definitely be called an external
characteristic curve on account of representing the conditions
external to the generator, there is shown a total characteristic
curve, O C B. The latter curve represents the relation between the
current and the total voltage developed in the armature, and may be
plotted from the external characteristic curve if the resistance of
the armature between brushes and the resistance of the series field
winding be known. For example, assume these combined resistances
amount to .6 ohm. At 30 amperes there would be required 30 × .6 = 18
volts to force this current through the armature and field windings.
At 30 amperes the external pressure is 65 volts, as shown by the
curve O A; the total voltage developed for 30 amperes is, therefore,
the external voltage plus the internal voltage or 65 + 18 = 83
volts. Plotting 83 volts for 30 amperes will give one point for the
external characteristic curve of this machine, and by determining in
like manner the total voltages developed for six or eight different
currents over the scale, sufficient data will be at hand for plotting
and drawing in the curve O C B.]
In steam engineering, a man who did not fully understand the method
of taking an indicator diagram would be considered not in touch with
his profession, and in electrical engineering the same would be true
of one ignorant of the method of obtaining characteristic curves.
The necessary arrangement or connection of the generator from
which it is desired to obtain a characteristic curve, consists in
providing a constant motive power so that the machine may be run
at a uniform speed, and when the field magnets of the generator
are separately excited the field current from the outside source
must also be maintained constant, preferably by a rheostat
connected in the field of the auxiliary exciting machine. It is
also necessary in every case that means be provided for varying
the main current of the generator step by step from zero to
maximum. This may best be done by employing a water rheostat, as
shown in fig. 2,909.
=Ques. What instruments are needed in making a test of dynamo
characteristics?=
Ans. A voltmeter, ammeter, speed indicator, the usual switches and
rheostats.
=Ques. How is the apparatus connected?=
Ans. It is connected as shown in fig. 2,910.
=Ques. Describe the test.=
Ans. Having completed the preliminaries as in fig. 2,910, the test
should be started with the main circuit of the generator open. Then,
in the case of the shunt machine, the speed should be made normal and
the field rheostat adjusted until the voltmeter reading indicates
the rated voltage of the machine at no load and readings taken. The
electrodes of the water rheostat should be adjusted for maximum
resistance and main circuit closed, and a second set of readings
taken. Several sets of readings are taken, with successive reductions
of water rheostat resistance. The results are then plotted on
coordinate paper giving the characteristic curve shown in fig. 2,908.
[Illustration: FIG. 2,909.--Water rheostat. It consists essentially
of a tank of suitable size containing salt water into which are
placed two electrodes having means of adjustment of the distance
separating them. The solution depends on the voltage. Pure water is
seldom used for pressures under 1,000 volts. The size of the tank is
determined by the size of the electrodes, and roughly the size of the
latter equal the number of amperes. With a current density of one
ampere per square inch, a water solution gives a drop of 2,500 to
3,000 volts per inch distance between the plates. Where high voltage
is used, the water must be circulated through and from the tank by
rubber hose allowing for 2,500 volts, a length of 15 to 20 feet of
1 inch hose to prevent grounding. In place of the arrangement shown
above, a barrel may be used for the tank, and for the electrodes,
coils of galvanized iron wire. This is the simplest form and is
satisfactory.]
=Ques. What does the characteristic curve (fig. 2,911) show?=
Ans. An examination of the curve shows that the highest point of
the curve occurs at no load or 0 amperes; that as the current is
increased, the voltage drops, first slightly to the point B and then
rapidly until the point E is reached, when any further lowering of
resistance in the main circuit to increase the current causes not
only a rapid decline in the voltage but also of the current until
both voltage and current become approximately zero.
[Illustration: FIG. 2,910.--Connections for test of dynamo. During
the test, one man should be assigned to the tachometer, another man
to the water rheostat, and there should preferably be one man at
each of the electrical measuring instruments. In order to enable the
man at the tachometer to keep the speed constant, he should be in
communication either directly or indirectly with the source of the
driving power, and the man at the water rheostat should be in plain
view of the man reading the ammeter so that the latter party may
signal him for the proper adjustment of the rheostat in order that
the desired increase of current be obtained for each set of readings.]
In some generators, a very slight current results even when the
terminals of the machine are actually short circuited; that is,
due to residual magnetism in the pole pieces, the lower portion of
the curve often terminates, not exactly at zero, but at a point
some distance along the current line.
The working portion of the curve is from A to C, at which time
the machine is supplying a fairly constant voltage. From C to E
shows a critical condition of affairs, while the straight portion
D O represents the unstable part of the curve caused by the field
current being below its proper value.
The position of the point C determines the maximum power the
machine is capable of developing, being in this case (47.5 × 25) ÷
746 = 1.59 horse power.
=Ques. How may the commercial efficiency of a generator be
determined?=
Ans. To obtain the commercial efficiency, the _input_ and _output_
must be found for different loads.
The input may be found by running the generator as a motor
at its rated speed, loading it by means of a Prony brake. The
generator must be stripped of all belting or other mechanical
connections, supplied with its normal voltage and full load
current, and the pressure of the Prony brake upon its armature
shaft or pulley adjusted until the rated speed of the armature is
obtained. The data thus obtained is substituted in the formula.
2π L W R
input in brake horse power = ---------- (1)
33,000
in which
L = length of Prony brake lever;
W = pounds pull at end of lever;
R = revolutions per minute.
The output or electrical horse power for the same load is easily
calculated from the formula
amperes × volts
output in electrical horse power = --------------- (2)
746
After obtaining value for (1) and (2) the commercial efficiency for
the load taken is obtained from the formula
output
commercial efficiency = ------ (3)
input
Having obtained the commercial efficiency, the difference between the
ideal 100 per cent. and the efficiency found will be due to certain
losses in the generator. These losses may be classified as
1. Mechanical.
2. Electrical.
The mechanical losses are the friction of the bearings and
brushes, and air friction. The electrical losses consist of the
eddy current loss, hysteresis loss, armature resistance loss, and
field resistance loss.
In testing for these losses, the generator to be tested should
be belted to a calibrated motor which latter machine should
preferably be of the constant pressure, shunt wound type.
The friction of the bearings and belt of the generator are
determined together by raising the brushes off its commutator and
running it at the rated speed by means of the calibrated motor.
[Illustration: FIG. 2,911.--Characteristic curve of shunt dynamo.
Suppose in making the test, the deflections on the meters for the
first readings be 63 volts and 0 amperes, the plotting of these
values will give the first point on the curve. Similarly, the second
readings with main circuit closed and maximum resistance in the water
rheostat may be assumed to be 62.5 volts and 7.5 amperes, which
plotted gives the second point B. A still further lowering of the
plate will permit a stronger current in the main circuit, and the
value of this together with its corresponding voltage will give a
third point for the curve. Neither for this reading, however, nor
for the following readings of the test should the field rheostat be
altered. When six or eight points ranging from zero to a maximum
current have been obtained and plotted, a curved line should be drawn
through them such as shown through ABCDEFG0, the _characteristic
curve_ of the dynamo. While the curve may be sketched in free hand,
it should preferably be drawn by the aid of French curves. In case
the French curve cannot be exactly made to coincide with all the
points as for instance C and D, it should be run in between giving an
average result, and smoothing out irregularities, or small errors due
to the "personal equation." The meter of course must be correct or
calibrated and the readings corrected by the calibration coefficient.]
The amount of power as ascertained from the calibration curve of
the motor for the voltage and current used therein when driving
the generator as just explained, is a measure of these two losses.
The power thus used is practically constant at all loads and is
about 2 per cent. of that necessary to drive the generator at full
load.
[Illustration: FIG. 2,912.--Characteristic curves for a compound
dynamo. If the machine be over compounded, the characteristic curve
has the form of the curve A B, which curve was obtained from a
machine over-compounded from 118 to 123 volts, and designed to give
203 amperes at full load. The preliminary arrangements for testing
a compound dynamo are similar to those for a shunt generator, and
if the shunt across the series field winding be already made up and
in position, the readings are taken precisely in the same manner.
It is generally considered sufficient if observations be recorded
at zero, ¼, ½, ¾ and full load. If it be desired to ascertain the
effect which residual magnetism has upon the field magnets the
current is decreased after the full load point is reached without
opening the circuit, and readings are taken in succession at ¾,
½, ¼ and zero load giving in this case the curve B C D E S. It is
thus seen that residual magnetism exerts no small effect upon the
voltage obtained at the different loads, for had there been no
residual magnetism in the field magnets the curve B C D E S would
have coincided with the curve A B. The curve A B, and the straight
line A X drawn through the points A and B, are almost identical,
and as A X represents the theoretical characteristic curve for the
machine, it is seen that compounding is practically perfect. In
order to insure such accurate results being obtained, providing
the machinery be correctly designed, requires considerable care in
taking the readings; for example, each step or load on the ascending
curve should not be exceeded before the corresponding deflection is
taken, else the residual magnetism will cause the pressure reading
to be higher than it actually should be, and the following pressure
readings will also be affected in the same manner. In case the shunt
to be employed across the series field has not been made up, it is
advisable to perform a trial test before taking the readings for the
curve as previously described. The trial test consists in taking
two readings,--one at no load and the other at full load, the shunt
being so adjusted as to length and section that the desired amount
of compounding will be obtained in the latter reading with normal
voltage at no load. If the first trial fail to produce the desired
result by giving too low a voltage at full load, the length of the
shunt across the series field should be increased, or its section
should be reduced by employing a less number of strips in its makeup;
again, if the voltage at full load be higher than that desired, there
must be made a decrease in length or an increase of section in the
shunt employed.]
The friction of the brushes can very conveniently be determined
next by lowering them on the commutator and giving them the proper
tension.
The increase in power resulting from the greater current that
will now be taken by the motor to run the dynamo at its rated
speed, will be a measure of this loss. In general, its value will
be about .5 per cent. of the total power required to drive the
dynamo at full load, and this also will remain constant at all
loads.
The friction of the air upon the moving armature of the dynamo
cannot be determined experimentally, but theoretically this loss
is small and may be estimated as .5 per cent.; it is also constant
at all loads.
The core loss may be determined experimentally by exciting
the field magnets of the dynamo with the normal full load field
current through the magnet coils, and noting the increase of power
required by the motor to maintain the rated speed of the dynamo
thus excited under no load, over that necessary under the same
conditions with no field excitation. This increase of power will
be the value of the core loss. The core loss is approximately 3
per cent. of the power required to operate the dynamo at full
load, and it is constant at varying loads. If it be desired to
divide the core loss into its component parts, it is necessary
also to run the dynamo under the same conditions as before with
field excitation but at half its rated speed. If, then,
H = the power lost in hysteresis at rated speed,
E = the power lost in eddy currents at rated speed,
T = the power lost in hysteresis and eddy currents at rated speed,
S = the power lost in hysteresis and eddy currents at half speed.
there may be formed the two following equations:
H E
T = H + E, and S = --- + ---,
2 2
from which the elimination of H will give E = 2T - 4S.
The value of the eddy current loss thus found will be about 1½
per cent., and constant at all loads.
Having previously ascertained the power lost in both eddy
currents and hysteresis, and knowing now the power lost in eddy
currents alone, it is easy to find that lost in hysteresis by
simply subtracting the latter known value from the former. The
value of the hysteresis loss is therefore approximately 1½ per
cent., and it is constant at different loads.
There yet remains to be determined the armature resistance
loss and the field resistance loss. As for the calibrated motor,
this may be disconnected from the dynamo, as it need not be used
further in the test.
The armature resistance is the resistance of the armature
winding of the dynamo, between the commutator bars upon which
press the positive and negative brushes. Assume that the value
of the armature resistance be known, call this value R ohms,
together with that of the full load armature current, which is
also known and which call I amperes, this is sufficient data for
calculating the armature resistance loss at full load. It is
evident that to force the full load current I through the armature
resistance R will require a pressure of R volts, and that the
watts lost in doing so will be the voltage multiplied by the
current. The armature resistance is consequently
IR × I = I^{2}R watts
or, expressed in horse power it is
I^{2}R ÷ 746
At full load it is usually about 2 per cent. of the total
power required to drive the generator fully loaded. The armature
resistance loss varies in proportion to the load, in fact, as the
last expression shows, it increases as the square of the armature
current.
The field resistance loss is calculated in the same manner as
just explained for the armature resistance loss, it being equal
in horse power to the square of the full load field current
multiplied by the resistance of the field winding and divided by
746. In a shunt dynamo it is practically constant at 2 per cent.
of the total power at full load, but in a series or in a compound
generator it will vary in proportion to the load.
HAWKINS PRACTICAL LIBRARY OF ELECTRICITY
IN HANDY POCKET FORM PRICE $1 EACH
_They are not only the best, but the cheapest work published on
Electricity. Each number being complete in itself. Separate numbers
sent postpaid to any address on receipt of price. They are guaranteed
in every way or your money will be returned. Complete catalog of
series will be mailed free on request._
=ELECTRICAL GUIDE, NO. 1=
Containing the principles of Elementary Electricity, Magnetism,
Induction, Experiments, Dynamos, Electric Machinery.
=ELECTRICAL GUIDE, NO. 2=
The construction of Dynamos, Motors, Armatures, Armature
Windings, Installing of Dynamos.
=ELECTRICAL GUIDE, NO. 3=
Electrical Instruments, Testing, Practical Management of Dynamos
and Motors.
=ELECTRICAL GUIDE, NO. 4=
Distribution Systems, Wiring, Wiring Diagrams, Sign Flashers,
Storage Batteries.
=ELECTRICAL GUIDE, NO. 5=
Principles of Alternating Currents and Alternators.
=ELECTRICAL GUIDE, NO. 6=
Alternating Current Motors, Transformers, Converters, Rectifiers.
=ELECTRICAL GUIDE, NO. 7=
Alternating Current Systems, Circuit Breakers, Measuring
Instruments.
=ELECTRICAL GUIDE, NO. 8=
Alternating Current Switch Boards, Wiring, Power Stations,
Installation and Operation.