NOTE.

These descriptions and illustrations of the Lancashire boiler are of

general value, owing to the fact that very many exhaustive tests and

experiments upon steam economy have been made and permanently recorded

in connection with this form of steam generator.

In the GALLOWAY form of boiler the flue is sustained and stiffened by

the introduction of numerous conical tubes, flanged at the two ends and

riveted across the flue. These tubes, a sketch of which are given in

fig. 18 (_a_), are in free communication with the water of the boiler,

and besides acting as stiffeners, they also serve to increase the

heating surface and to promote circulation.

[Illustration: Figs. 19, 20.]

The illustration (figs. 18, 19 and 20) give all the principal details

of a Lancashire boiler fitted with Galloway tubes. Fig. 18 represents a

longitudinal section and figs. 19 and 20 shows on a large scale an end

view of the front of the boiler with its fittings and also a transverse

section. The arrangement of the furnaces, flues, and the Galloway tubes

is sufficiently obvious from the drawings. The usual length of these

boilers is 27 feet, though they are occasionally made as short as 21

feet.

The minimum diameter of the furnaces is 33 inches, and in order to

contain these comfortably the diameter of the boiler should not be

less than 7 feet. The ends of the boiler are flat, and are prevented

from bulging outwards by being held in place by the furnaces and flues

which stay the two ends together and also by the so-called gusset stays

_e_, _e_. In addition to the latter the flat ends of the boiler have

longitudinal rods to tie them together; one of these is shown at _A_,

_A_, fig. 18.

The steam is collected in the pipe _S_, which is perforated all along

the top so as to admit the steam and exclude the water spray which may

rise to the surface during ebullition. The steam thence passes to the

stop valve _T_ outside the boiler and thence to the steam pipes to the

engines.

There are two safety valves on top of the boiler on _B_ (fig. 18),

being of the dead weight type described hereafter, and the other, _C_,

being a so-called low water safety valve. It is attached by means of a

lever and rod to the float _F_, which ordinarily rests on the surface

of the water. When through any neglect, the water sinks below its

proper level the float sinks also, causing the valve to open, thus

allowing steam to escape and giving an alarm. _M_ is the manhole with

its covering plate, which admits of access to the interior of the

boiler and _H_ is the mud hole by which the sediment which accumulates

all along the bottom is raked out. Below the front end and underneath,

the pipe and stay valve are shown, by which the boiler can be emptied

or blown off.

On the front of the boiler (fig. 19) are shown, the pressure gauges,

the water gauges and the furnace door; _K_ is the feed pipe; _R_, _R_,

a pipe and cock for blowing off steam. In the front of the setting are

shown two iron doors by which access may be gained to the two lower

external flues for cleaning purposes.

In the Lancashire boiler it is considered advisable to take the

products of combustion, after they leave the internal flues, along the

bottom of the boiler, and then back to the chimney by the side. When

this plan is adopted the bottom is kept hotter than would otherwise be

the case, and circulation is promoted, which prevents the coldest water

from accumulating at the bottom.

The Galloway (or Lancashire) boiler is considered the most economical

boiler used in England, and is being introduced into the United States

with success. The long traverse of heat provided (three turns of about

27 feet each) contributes greatly to its efficiency.

It may be useful to add the following data relating to this approved

steam generator, being the principal dimensions and other data of the

boiler shown in fig. 18:

Steam pressure, 75 lbs. per sq. inch.

Length, 27 feet.

Diameter, 7 feet.

Weight, total, 15-1/2 tons.

Shell plates, 7/16 inch.

Furnace diameter, 33 inches.

Furnace Plates, 3/8 inch.

End plates, 1/2 inch.

Grate area, 33 sq. feet.

Heating surface:

In furnace and flues 450 sq. feet.

In Galloway pipes, 30 „

In external flues, 370 „

----

850 sq. feet.

We have thus detailed step by step the improvement of the steam boiler

to a point where it is necessary to describe at length the locomotive,

the marine, the horizontal tubular and the water tube boilers, which

four forms comprehend ninety-nine out of one hundred steam generators

in use in the civilized world at the present time.

Maxims and Instructions for the Boiler Room Useful to Engineers, Firemen & Mechanics; Relating to Steam Generators, Pumps, Appliances, Steam Heating, Practical Plumbing, etc. · 第 48 / 328 题