ARTICLE II.

_An account of Dr. Physick’s improvement of Desault’s apparatus for

making permanent extension in oblique fractures of the os femoris._

Dr. Physick having observed that in the application of Desault’s

apparatus, the patient was sometimes injured by the pressure of the

strap or roller _g g_ (plate 2) which passes under the tuberosity of

the ischium for the purpose of making counter-extension, devised the

following method of remedying this inconvenience, in which he succeeded

to his wishes.

He directed the upper end of the long external splint to be formed like

the head of a crutch, and the splint itself to be lengthened so as to

reach and bear against the axilla of the affected side, which must

be well defended from pressure by a bolster of flannel or some other

soft material. By this expedient the Dr. evidently formed two points

of counter-extension, instead of one, as is the case in the apparatus

of Desault. Between these two points, namely, the axilla and the

perineum, the same quantity and force of pressure is, by Dr. Physick’s

improvement, _divided_, which, in the original apparatus of Desault, is

borne by the _perineum alone_. The risque of excoriation and injury to

the patient, then, in the former case, is to that which he runs in the

latter, only as one to two, or nearly so. As it is no less the duty of

the surgeon to prevent suffering than it is to remove deformity or to

save life, Dr. Physick has certainly in this respect made an important

step in the advancement of his profession.

But there is still another advantage derived from the lengthening of

the external splint. In the original apparatus of Desault, the strap

_gg_ intended for counter-extension, by passing no higher up than the

spine of the ilium, runs too much across, and therefore acts too much

on, the upper part of the thigh. By this it not only irritates the

muscles of the part, and induces them to contract, but also tends to

draw the upper fragment of the os femoris a little outward, and thus to

render the thigh in some measure deformed. But, in the improvement of

Dr. Physick, the strap _gg_ is secured in a mortise cut in the external

splint, about midway between the spine of the ilium and the axilla.

This strap, by being thus carried higher up on the body, does not run

across the thigh at all. It consequently presses on and irritates the

muscles much less, acts more in the direction of the os femoris, and

has no tendency to draw the superior fragment outward.

Hence this improvement not only diminishes the patient’s sufferings,

but gives him, perhaps, the best possible chance of having his limb

preserved free from deformity.

[Illustration: _Plate 3._

_Fig. 1._

_Fig. 2._

_Fig. 3._

_Hooker delt._

_Tanner, Sc._]

Another improvement made on the lower end of the external splint by Dr.

James Hutchinson deserves also to be mentioned. It was found that in

the original apparatus of Desault, the strap or roller L (plate 2)

used for the purpose of extension, had a tendency to draw the foot too

much outward. This fault Dr. Hutchinson very ingeniously remedied, by

attaching to the lower part of the external splint, a little above the

mortise, a small block extending inwardly, at a right angle with the

splint, so far as to be on a line with the middle of the sole of the

foot. Over the end of this block, in which a notch is cut to receive

them, the ends of the strap L are carried, previously to their being

secured to the external splint. By means of this expedient extension is

made precisely in the direction of the limb, and the inconvenience of

drawing the foot outward is completely obviated.

Thus improved by Drs. Physick and Hutchinson, the apparatus of Desault

for oblique fractures of the os femoris, leaves, perhaps, scarcely a

remaining desideratum on the subject.

A Treatise on Fractures, Luxations, and Other Affections of the Bones · 第 179 / 182 题