If [theta], [theta]' be small, we may take

R = 2t[theta]^2/[mu] (1).

as sufficiently approximate.

The condition of distinctness is here satisfied, since R is the same

for every ray emergent parallel to a given one. The rays of one

parallel system are collected by the lens to a focus at a definite

point in the neighbourhood of the original source.

The formula (1) was discussed by Herschel, and shown to agree with

Newton's measures. The law of formation of the rings follows

immediately from the expression for the retardation, the radius of the

ring of n^(th) order being proportional to n and to the square root of

the wave-length.

S 10. _Interferometer._--In many cases it is necessary that the two rays

ultimately brought to interference should be sufficiently separated over

a part of their course to undergo a different treatment; for example, it

may be desired to pass them through different gases.

[Illustration: FIG. 6.]

A simple modification of Young's original experiment suffices to solve

this problem. Light proceeding from a slit at A (fig. 6) perpendicular

to the plane of the paper, falls upon a collimating lens B whose

aperture is limited by two parallel and rather narrow slits of equal

width. The parallel rays CE, DF (shown broken in the figure)

transmitted by these slits are brought to a focus at G by the lens EF

where they form an image of the original slit A. This image is

examined with an eye-piece of high magnifying power. The interference

bands at G undergo displacement if the rays CE, DF are subjected to a

relative retardation. Consider what happens at the point G, which is

the geometrical image of A. If all is symmetrical so that the paths

CE, DF are equal, there is brightness. But if, for example, CE be

subjected to a relative retardation of half a wave-length, the

brightness is replaced by darkness, and the bands are shifted through

half a band-interval.

[Illustration: FIG. 7.]

An apparatus of this kind has been found suitable for determining the

refractivity of gases, especially of gases available only in small

quantities (_Proc. Roy. Soc._, 1896, 59, p. 198; 1898, 64, p. 95).

There is great advantage in replacing the ordinary eye-piece by a

simple cylindrical magnifier formed of a glass rod 4 mm. in diameter.

Under these conditions a paraffin lamp sufficed to illuminate the slit

at A, and allowed the refractivities of gases to be compared to about

one-thousandth part.

If the object be to merely see the bands in full development the

lenses of the above apparatus may be dispensed with. A metal or

pasteboard tube 10 in. long carries at one end a single slit

(analogous to A) and at the other a double slit (analogous to C, D).

This double slit, which requires to be very fine, may be made by

scraping two parallel lines with a knife on a piece of silvered glass.

The tube is pointed to a bright light, and the eye, held close behind

the double slit, is focused upon the far slit.

S 11. _Other Refractometers._--In another form of refractometer,

employed by J. C. Jamin, the separations are effected by reflections

at the surfaces of thick plates. Two thick glass mirrors, exactly the

same in all respects, are arranged as in fig. 7. The first of the two

interfering rays is that which is reflected at the first surface of

the first reflector and at the second surface of the second reflector.

The second ray undergoes reflection at the second surface of the first

reflector and at the first surface of the second reflector. Upon the

supposition that the plates are parallel and equally thick, the paths

pursued by these two rays are equal. P represents a thin plate of

glass interposed in the path of one ray, by which the bands are

shifted.

[Illustration: FIG. 8.]

In Jamin's apparatus the two rays which produce interference are

separated by a distance proportional to the thickness of the mirrors,

and since there is a practical limit to this thickness, it is not

possible to separate the two rays very far. In A. A. Michelson's

interferometer there is no such restriction. "The light starts from

source S (fig. 8) and separates at the rear of plate A, part of it

being reflected to the plane mirror C, returning exactly, on its path

through A, to O, where it may be observed by a telescope or received

upon a screen. The other part of the ray goes through the glass plate

A, passes through B, and is reflected by the plane mirror D, returns

on its path to the starting point A, where it is reflected so as

nearly to coincide with the first ray. The plane parallel glass B is

introduced to compensate for the extra thickness of glass which the

first ray has traversed in passing twice through the plate A. Without

it the two paths would not be optically identical, because the first

would contain more glass than the second. Some light is reflected from

the front surface of the plate A, but its effect may be rendered

insignificant by covering the rear surface of A with a coating of

silver of such thickness that about equal portions of the incident

light are reflected and transmitted. The plane parallel plates A and B

are worked originally in one piece, which is afterwards cut in two.

The two pieces are placed parallel to one another, thus ensuring exact

equality in the two optical paths AC and AD" (see Michelson,

_Light-Waves and their Uses_, Chicago, 1903).

The adjustments of this apparatus are very delicate. Of the fully

silvered mirrors C, D, the latter must be accurately parallel to the

image of the former. For many purposes one of the mirrors, C, must be

capable of movement parallel to itself, usually requiring the use of

very truly constructed ways. An escape from this difficulty may be

found in the employment of a layer of mercury, standing on copper, the

surface of which automatically assumes the horizontal position.

Michelson's apparatus, employed to view an extended field of

homogeneous light, exhibits Haidinger's rings, and if all is in good

order the dark parts are sensibly black. As the order of interference

increases, greater and greater demand is made upon the homogeneity of

the light. Thus, if the illumination be from a sodium flame, the rings

are at first distinct, but as the difference of path increases the

duplicity of the bright sodium line begins to produce complications.

After 500 rings, the bright parts of one system coincide with the dark

parts of the other (Fizeau), and if the two systems were equally

bright all trace of rings would disappear. A little later the rings

would again manifest themselves and, after 1000 had gone by, would be

nearly or quite as distinct as at first. And these alternations of

distinctness and indistinctness would persist until the point was

reached at which even a single sodium line was insufficiently

homogeneous. Conversely, the changes of _visibility_ of the rings as

the difference of path increases give evidence as to the duplicity of

the line. In this way Michelson obtained important information as to

the constitution of the approximately homogeneous lines obtained from

electrical discharge through attenuated metallic vapours. Especially

valuable is the vacuum tube containing cadmium. The red line proved

itself to be single and narrow in a high degree, and the green line

was not far behind.

But although in Michelson's hands the apparatus has done excellent

spectroscopic work, it is not without its weak points. A good deal of

labour is required to interpret the visibility curves, and in some

cases the indications are actually ambiguous. For instance, it is

usually impossible to tell on which side of the principal component a

feebler companion lies. It would seem that for spectroscopic purposes

this apparatus must yield to that of Fabry and Perot, in which

multiple reflections are utilized; this is a spectroscope in the

literal sense, inasmuch as the constitution of a spectrum line is seen

by simple inspection. (R.)

Encyclopaedia Britannica, 11th Edition, "Inscriptions" to "Ireland, William Henry" Volume 14, Slice 6 · 第 30 / 49 题