CHAPTER IV.

HOW TO TEST FOR AND CLEAR TROUBLES IN

PRIVATE BRANCH EXCHANGE SWITCHBOARDS.

=Station can’t call=: When a station can’t call, the trouble may be due

to the line being open, or too much resistance in the line; or to the

signal being open, or short-circuited, or stuck.

Short-circuit the line in the back of the switchboard or at correcting

frame; if the signal does not operate plug up the jack with a plug and

see if the cord signal will operate; if it will not the open is between

the frame and the springs of the jacks if the cord signal will operate,

the trouble is back of the jack springs, and may be an open, or it may

be that the drop is short-circuited or stuck. Test with a receiver or

lamp, if you get good battery on the locknuts but can’t throw the drop,

it must be short-circuited or stuck; if you get no battery there is an

open; short-circuit the inner contacts of the jack, and if this brings

up the signal the open is in the jack; take the jack out and repair it.

If short-circuiting the inner contacts will not operate the signal, the

same may be open; test from the ground strap of the jack direct to the

signal terminals; if the signal tests all right the wire leading from

one side of the signal to one inner contact of the jack must be open;

prove by short circuiting same out with a test cord.

If there is battery on the jack but the signal won’t come up, push

gently against the back of the armature of the signal with a tooth pick

until it starts to raise; you can tell by the feeling if it is at all

stuck.

Another good way to tell whether the signal sticks is to go to the

station and hold the receiver to your ear and then allow the hook to

raise. When the signal flies up it can be heard in the receiver as a

sort of “tremble.” This “tremble” should take place the instant the

hook comes up; if it is delayed, the signal must be sticking.

This test can also be made from the frame with a head receiver.

To test whether the signal is short-circuited, see how brightly your

lamp burns when connected at the frame and then compare with other

signals which are all right; a signal which is wholly or partly

short-circuited will have less resistance than the others, and the lamp

will burn brighter.

If the signal comes up from the frame but will not come up from the

instrument, the line may have too much resistance and the signal will

have to be adjusted so as to be more sensitive.

If a station on a long line has trouble calling at times, there may be

a poor connection in the circuit which varies; or it may be that the

signal fails to work only when the board is busy, due to the drop in

voltage on the battery feed when much current is being drawn from it;

the signal will have to be adjusted more delicately or the battery feed

increased.

[Illustration: Fig. 4.]

=Station Signal Stays up=: The line must be either crossed, or grounded

on the battery side. Plug into the jack with a detached plug and cord,

and then test successively on the ring and tip of the detached cord

with a receiver or lamp that is connected to battery. This will show

if there is a ground on either side of the line. If both sides test

clear of grounds, there must be a cross; to prove this, ground the tip

side by holding the tip of the detached cord on the tip of any other

plug; if there is a cross the ring side will then test grounded. To

locate the trouble, open the line successively at the frame cable box

instrument, etc., and note the effect on the signal.

In testing with a receiver for grounds or crosses on lines, you should

be guided by the click when you break contact; otherwise, you are

likely to be deceived by the electrostatic capacity of the line and

condenser in the instrument. In such tests you may get a strong click

when you make contact, particularly if the line runs through a cable,

and you may also get plenty of induction on the line; but if you do not

get a click when you break contact, there is no current flowing through

your receiver, and therefore the line is clear.

If plugging into the jack does not restore the signal, the trouble must

be a cross in the jack, or in the signal itself. Examine the jack lugs,

and also the inner end of the signal winding, which may be in contact

with the iron mounting strip. If the trouble is not here, disconnect

the wire going to the jack from the signal; this will show whether the

trouble is in the signal itself.

If the sleeve of a station jack is grounded, the cord circuit relay

will operate when you plug into the jack, and cut the battery off of

that pair of cords. Touching the tip of a plug to the sleeve of a

station jack with the listening key thrown will show if the sleeve

is grounded by giving a click in the operator’s receiver, the same as

touching the sleeve of a trunk jack will do. The ground may be due to

the sleeve being crossed with the sleeve of a trunk jack, or crossed

with the sleeve of a station jack that is connected to a trunk jack; or

it may be between the sleeve and the inner contact of the jack on the

ground side.

=Battery Feed and Trunks=: The battery feed and trunks must always be

poled properly. To test the poling of the feed, run a temporary ground

and touch it to the ring of the back plug. If this does not bring up

the cord signal the feed is poled wrong, and the feed and ground will

have to be reversed.

To test the poling of a trunk, plug into the trunk-jack with the front

plug of any pair, say No. 1 pair; then touch the tip of any other plug

to the ring of the back plug of No. 1 pair; if this does not bring up

the cord signal on No. 1 pair the trunk is poled wrong.

One of the troubles caused by the wrong poling of a trunk is that

if the operator plugs in to answer the trunk while she has another

listening key thrown, her transmitter goes dead.

If operator at the central office can’t throw a trunk drop at a private

branch switchboard the same may be open, or the condenser may be open.

Bridge a receiver across the drop; if you can get a good ring in the

receiver the condenser is all right and the drop is probably open. If

you can’t get a ring across the drop, short-circuit the condenser; if

this puts battery through the drop and brings it up, the condenser must

be open.

If a cord circuit relay fails to operate on any trunk, the ground strap

may be broken off of the jack. Plug up the jack, then touch the butt

of the plug with the tip of a plug of any other pair; if this operates

the relay, it shows that the sleeve of the jack did not operate it, and

therefore the sleeve connection must be open.

The sleeve connections are often taken off purposely on tie trunks.

If the operator complains of central cutting her off, some of the

holding coils may be open. Instructions are given further ahead for

testing them.

If plugging up a trunk causes the cord circuit relay to vibrate the

battery feed or ground must be open.

If the line or cord signals fail to come up properly the battery feed

may be weak; this may be due to a poor connection in the feed or

ground, or to one of the conductors of the feed being open, or to the

feed being grounded through resistance. Bridge a lamp across the feed;

it should burn brightly if no current is being used on the switchboard.

Throw a listening key, or bridge a receiver across the feed; if this

puts the lamp out, or dims it excessively, the feed or ground has a

high resistance on it, or some of the conductors are open. Disconnect

the conductors one at a time at the table head or protector, and see

if each one will light your lamp properly. If the lamp burns dimly

when no current is being used on the switchboard, the feed is probably

grounded through resistance; disconnect it from the switchboard and

test; if it still gives a dim lamp disconnect at the protector and test

again to prove whether trouble is inside or outside.

The amount that a lamp bridged across a battery feed will be dimmed

by throwing a listening key or bridging on a receiver depends upon

the resistance of the feed. If the feed is very long the lamp will be

dimmed very much; if the feed is short or consists of several pair, the

lamp will be dimmed but slightly. Each inspector should become familiar

with the behavior of the battery feeds on all his important boards; he

should know how the lamp burns when the board is idle, and how much it

is dimmed when a certain number of connections are up, so that in case

of trouble he can tell at once by a lamp test whether the feed is O.K.

or whether it has too much resistance, or is partially grounded.

Troubles Causing Bells to Ring.

A swinging open or swinging ground on the battery feed causes the bells

at the stations to ring by charging and discharging the condensers.

Generator feed crossed with the battery feed causes bells to ring.

Examine wiring and generator contacts at ringing keys.

Where the spring of a station jack does not break from, or is crossed

with the inner contact, all bells may be rung by ringing on that jack

with power generator, which is always grounded on one side.

If the outer contact of a ringing key makes before the inner contact

breaks, all bells may be rung when that key is used, by the generator

current passing down through one side of the retardation coil to the

battery feed.

Cord Circuit.

Tip and sleeve crossed causes vibrating relay on that pair.

Tip and ring crossed short-circuits the cord.

Ring and sleeve crossed causes relay to vibrate when ring and tip of

plug are short-circuited, or when the plug is put in a station jack

with the station receiver off the hook,—sometimes merely throwing the

listening key on that pair will make the relay vibrate.

Touching ring to tip and tip to ring of the two plugs of any pair

should give a spark, and the signal should also come up when the ring

of the plug is touched with a tip. If there is trouble, take any

other plug which is O.K. and test the bad pair; if both rings or both

tips fail to give a spark, there is probably an open at the relay,

the retardation coil, or the soldered connections on the listening

key. If only one cord tests open, and the other one of the same pair

tests O.K., ring on the bad cord and feel for generator current in the

plug. If you get current, the open must be at the inner contact of

the ringing key; or, it may be in the cord signal. If you cannot get

generator on the plug, the open is in the cord.

To locate any open that effects both cords, test successively on inner

contacts and swinging contacts of relay, inner and outer lugs of

retardation coil, and swinging contacts of listening key, you should

get battery across all of these points.

If either cord of a pair is short-circuited it short-circuits both

cords and you will not get proper sparks when touching ring to tip

and tip to ring but you may get small sparks. Also the operator’s

transmitter will be dead on that pair of cords and if you test with a

receiver or lamp you will get little or no battery between the ring

and tip of either plug, but will get battery of about half the proper

strength from either the ring or the tip of either plug to either the

ring or the tip of a plug of any other pair.

You can also tell whether a cord circuit is short-circuited by bridging

your receiver around one half of the retardation coil; if there is a

short-circuit, part of the current that is flowing around through the

coil will go through your receiver, giving you a click.

To locate the short-circuit, ring on the two cords successively, and

feel on the plugs for generator. If both cords test clear, the trouble

must be back of where the circuit branches at the listening key;

disconnect successively at the relay, the retardation coil, and the

listening key until you locate the trouble.

In most of the private branch exchange switchboards the battery goes

first to the inner contacts of the relay, then through the swinging

contacts to the retardation coil, and from the retardation coil to the

swinging contacts of the listening key; in other boards the battery

goes first to the retardation coil, then through the relay contacts to

the listening key. From the listening key it goes to the inner contacts

of the ringing key, and from the swinging contacts of the ringing keys

to the cord fasteners.

If a cord circuit is open at the relay or retardation coil, it will

still work on a trunk connection, the trunk supplying the battery, if

the central office is common battery system.

Lamp tests of the retardation coils and cord signals can be made by

bridging a lamp across the bus-bars and then short-circuiting the tip

and ring of every cord successively. Each one should dim the lamp

the same amount; if one cord dims it less than the others, it shows

that there is more resistance in that cord circuit—possibly a bad

connection, or a cord signal with too much resistance. If one cord dims

it more than the others, there must be less resistance in that cord

circuit, probably one half of the retardation coil is short-circuited.

(This test fails where there is a floater battery, or a battery feed of

very low resistance.) To prove that one side of the retardation coil is

short-circuited, short-circuit one of the plugs of that pair, and then

bridge a receiver successively around the two sides of the coil, no

click on one side should mean that that side was short-circuited.

A finer test can be made by bridging the lamp across the tip and

ring of the cord, and short-circuiting out the two sides of the coil

successively; each side should brighten the lamp exactly the same

amount. If one side brightens it more than the other, that side has

more resistance than the other.

Unbalanced coils are usually noisy, especially on long lines. An

unbalanced coil can usually be detected by simply listening on each

pair of cords, successively; if the battery feed induction is stronger

on one pair than on the other, that pair is probably unbalanced.

In most boards the holding coil is bridged across the outer contacts of

the relay. In other boards one end of the coil connects to one swinging

contact of the relay, and the other end to the opposite outer contact.

To test the holding coil, plug into a trunk jack with the back plug

and throw the listening key, which will bring up the cord signal, then

throw the listening key normal. If the signal stays up the holding

coil is O.K., if it disappears the holding coil circuit must be open.

The trouble may be that the relay contact does not close, or the coil

itself may be open.

Test by plugging into a trunk with the back cord and then

short-circuiting the holding coil; if the cord signal comes up

the holding coil must be open; if it does not come up, leave the

short-circuit on the coil and bridge out the holding coil contacts

of the relay. When you bridge out the contact where the open is, the

signal will come up.

To test the relay on any cord circuit, touch the tip of any other plug

to the sleeve of either plug of that pair; if this does not operate the

relay the sleeve conductor of the cord may be open; if neither plug of

the pair will operate it, the relay itself may be open; test with a

receiver or lamp.

Touching the tip of one plug to the sleeve of the other plug of the

same pair should make the relay vibrate.

To test a switchboard cord, plug into the cord testing jack (every

board should have a testing jack connected to put battery direct on

your head receiver) and shake the cord, and turn and shake the plug in

the jack, while you listen in the operator’s receiver for any cut-off

or bad connection. Do not have any listening key thrown while you

are testing switchboard cords; also see that the operator’s receiver

is poled so that the current from the cord strengthens the magnetism

instead of weakening it otherwise you will not get a sensitive test.

The tips and rings of the plugs must be clean, or else they will be

scratchy.

Be very careful that none of the plugs are bent or “lopsided;” such

plugs may work all right in some jacks and cut-off in others. If

turning a plug around in a jack causes a cut-off the plug should be

condemned; sometimes the jack may be at fault, and the long spring will

have to be given more “set.” After changing switchboard cords, always

test the new ones for opens, short-circuits and reversals.

=Cross-Talk=: Solder dropped on the cord fasteners, or a cross at the

keys, may connect two different cord circuits together, and cause

cross-talk between them.

Retardation coils may be crossed with their cases, and cause cross-talk

by the cases being in contact. Condensers on trunk drops may make two

trunks cross talk in the same way. Test by bridging a receiver from

the case of the suspected coil or condenser to battery and to ground

successively. There will be no click if the case is clear.

Unbalanced retardation coils, or a weak battery, may also cause

cross-talk.

A listening key that does not break contact on both sides will cause

cross-talk when that pair of cords is used; if with all keys normal you

get a click in the operator’s receiver when you touch the tip of any

plug to the frame of the operator’s transmitter, the operator’s circuit

is in contact with some cord circuit at the listening key. To find out

which key, see that all keys are normal and then vibrate the relay on

each pair of cords successively by touching the tip of one plug to the

sleeve of the other; when you come to the pair where the cross is, the

buzz will be heard plainly in the operator’s receiver; on the others it

will be heard very faintly.

=Operator’s Set=: To test the receiver cord, put a plug in the cord

testing jack, this puts battery through the receiver, and by shaking

the cord any fault will show up provided the receiver is poled

properly. Do not have any listening key thrown when making this test.

To test the transmitter cords, throw up any listening key and listen in

the operator’s receiver while you shake the cords.

To locate an open in the operator’s primary circuit, throw any

listening key, and then bridge a receiver successively around the

several parts of the circuit, that is, the 200 ohm resistance coil, the

transmitter, (including its cords), and the primary. When you bridge

around the part that is open, you will get a click in the receiver.

To locate an open in the secondary circuit, short-circuit out the

condenser so as to get battery through the circuit and then bridge

around the receiver and secondary with a receiver until you have found

where the open is.

=Buzzer and Buzzer Relay=: If a buzzer which works off the battery feed

fails to operate at times, although the buzzer relay comes up, probably

it is not sensitive enough, and when the board is busy the battery feed

it not strong enough for it. Adjust the buzzer more delicately and

test it when the board is idle and when it is busy. To make a board

busy artificially, bridge a head receiver across the bus-bars; that is

equivalent to several pairs of connections being up.

If some of the station lines are very long, the buzzer relay may fail

to come up on them, or come up so weakly as not to make good contact.

To cure this, adjust the relay more delicately.

If a trunk drop won’t operate the buzzer relay when the key is up, the

trouble is probably at the night bell contact of the drop. If none

of the trunk drops will operate it, the relay may not be adjusted

delicately enough, or the 500 ohm resistance coil may be open. Bridge

around the trunk drop contacts with a receiver. If you get no battery

the coil must be open; prove by bridging the coil out and repeating the

test.

A heavy ground on the ground side of any station line will prevent the

buzzer relay from coming up by shunting it out. A light ground will

sometimes cause trouble on the long lines only.

A short-circuited condenser or a slight leak across any line or lines,

may hold up the buzzer relay. Test the lines for crosses and grounds,

as previously instructed. If the buzzer relay comes up at times when

no signal is up, the trouble may be due to some station on a long line

trying to call, and the signal not sensitive enough to come up.

General.

To prove that a board is perfectly clear, disconnect the battery feed

from the negative bus-bar, and put a lamp or receiver in series. If you

get no current then all the lines are free from crosses, they are free

from grounds on the battery side, and the other circuits in the board

are also clear of crosses. (This test can only be made when there are

no connections up, no listening keys thrown, and no stations calling.)

To prove that the ground sides of all the lines are clear, disconnect

both the feed and ground wires from the bus-bars, and then test through

a lamp or receiver from the battery feed to the ground bus-bar; if you

get no current, the lines are all clear on the ground side.

INSPECTION

How to Inspect Subscribers’ Instruments.

1st.—Ask the subscriber if his instrument works properly and repair

any defect that he reports. Also be sure the instrument is securely

fastened to the wall or desk.

2d.—Clean and polish the varnished and nickeled parts of the

instrument; open the bell and see that it is clean and in proper

condition inside, and that the hook, ringer, and other moving parts

work properly and clean the hook contacts with paper if they are dirty

or make a scratching noise in the receiver.

3d.—See that all binding post connections are tight, test all cords; in

testing the receiver cord, put battery through it by short-circuiting

the condenser; change any cords or other parts that are defective or

unsightly.

4th.—Clean the receiver outside, remove the cap and examine the

diaphragm and clean the magnets; in cleaning the magnets rub them off

with your coat sleeve or a clean rag rather than with your hands, as

the moisture from your hand will cause them to rust.

5th.—Examine the adjustment of the bell and test by getting a ring from

the operator, at the same time test the transmission and hearing.

Test all extention bells by getting a ring from the operator; inspect

all other apparatus, such as hand generators, switches, local

batteries, fans booths and signs. It is important that signs should be

kept in good condition; dirty or unsightly ones should be cleaned or

ordered changed, and you should be particularly careful to see that all

signs are securely hung.

6th.—Inspect all wiring, including the leading in wires, the inside

line wires, the battery wires and the ground wires; also the

protection, the fuses, any extention bells and also see that the

ground is properly made that it is connected to the proper pipes. If a

gas pipe has been used see that the bridge on the meter has not been

disturbed since the last inspection.

7th.—See that the protector contains the proper kind of fuses, and if

it can be gotten at readily; examine the connections and remove the cap

from over the carbons to see that no one has left the carbons out.

8th.—If a subscriber applies to you to have an additional instrument

installed, take his name and address and turn them in to the manager;

if he wants his telephone moved or disconnected, or circuit number

changed, or extention bell or sign installed, request him to call up

the managers office.

If he complains of poor operating service, or of interference by other

subscribers on his line, refer him to the manager.

If he complains of some trouble that is in the outside line or at the

central office, report the matter to the chief inspector at once.

9th.—In making recommendations, state briefly but plainly just what you

want done and give the reason why. If the installer has done any work

at the station since your last inspection, and has failed to leave it

in proper condition, accompany the recommendation that you make with a

written complaint.

Making First Inspections of New Installations.

In inspecting a new installation, or an instrument that has been

moved or changed since your last inspection, or in going over your

instruments for the first time, the inspection should be made more

carefully than at other times.

Ask the subscriber if he has any extention stations, extention bells

or other apparatus attached to his instrument, also look out for them

while you are making the inspection and tracing out the wiring.

Open the desk stand and see that all the locknuts are tight and

soldered connections are perfect.

Examine and shake all soldered connections in the bell.

Trace out all of the wiring and be sure to see that all splices are

properly soldered and taped and see that no tacks are driven in the

splice.

Make a lamp or receiver test of the protector and the instrument

ground, to see that they are good and have no resistance.

See that the protector is securely fastened, that the connections are

all tight, that the fuses and carbons are of the proper kind, and that

the micas have the open side down.

Test the fuses for loose connections inside, by bridging your head

receiver across the binding post at the instrument end of the protector

and listening for a cut-off, while you shake and jar the fuses.

Test all switches to see that they make all proper connections, oil the

hand generators and see that the bell clapper works freely.

See that the specifications have been complied with in placing the

protector and the instrument, in running all the wire, and in every

other particular; that the desk stand cords are cleated, and protection

cleats used where needed; that desk sets give two hook clicks; that

snap switches are of the indicating type; that the connections to all

binding posts are neat and of proper length; that the booth is clean

and have plugs in all the screw holes; that they have no broken glass

and have linoleum on the floor, and that the doors and latches all work

freely.

See that the protector is placed so as not to be in the way of

curtains; that no damage has been done to the subscribers property;

that all apparatus has been installed so that it will not be in his

way, and will not be exposed to disfigurement, damage, trouble from

dampness or rain, etc., that wire is run where it will be safe from

injury, dampness and wear; in short, see that the installation is done

according to specifications in every respect.

See that the cut-in (the wires from the pole to the house) are properly

made and are of the proper kind of wire.

DON’T FORGET THAT YOUR REPUTATION AS AN

INSPECTOR IS AT STAKE.

FOOTNOTE

[1] Where reference is made to “hook clicks” in these instructions, the

instrument is understood to be a desk stand, wall sets are so connected

as to give only one hook click on raising or lowering the hook.

When reference is made to the red, white or green strand of the desk

stand cord, it is understood that the red goes to the hook, the white

to the receiver and the green to the transmitter, using the standard

Western Electric cord.

When reference is made to L1, L2 or G you will find them on diagram

No. 1 or No. 2. When reference is made to “A” or “B” you will find

them on diagram No. 3.

—————————————— End of Book ——————————————

Transcriber’s Note (continued)

Page 42 – “deskstand” changed to “desk stand” (Open the desk stand)

Page 43 – “lineoleum” changed to “linoleum” (have linoleum on the

floor)

Footnote – “G1” changed to “G” (When reference is made to L1, L2 or G)

The words “extension” and “extention” are used interchangeably throughout

the book and have been left unchanged. Some missing punctuation and other

minor typographical errors have been corrected without note.

The single footnote has been placed at the end of the book.