CHAPTER III.

FOUR-PARTY SET.

(Diagram No. 3.)

Tests of the transmitting and hearing circuits can be made in very much

the same manner as in a straight set. On account of the relay coil

being bridged between No. 2 and No. 3 terminals of the induction coil,

a four-party desk set, if in perfect order, will give two hook clicks,

no matter how it is poled.

To make a perfectly sure test for primary and secondary crossed

together, it is necessary to disconnect one terminal of the relay

winding; then with the receiver on the hook, test from the L2 post to

the secondary with your head receiver; if you get current there is a

cross.

Reversals of the three wires at the top of the instrument may cause a

variety of troubles, just as in the two-party sets.

Ringing Circuit.

=Relay=: Failure of the relay to come up when the operator rings may be

caused by:

Condenser open.

Relay short-circuited or open.

Hook contacts, or red and white strands of desk stand cord, or primary

and secondary of induction coil crossed together.

Primary open.

Trouble at central office.

Test just as though it was a straight set except when testing for

relay short circuited, or for a cross between primary and secondary,

(in which case you must open one terminal of the relay winding, as

previously directed); and except when testing for relay open, which you

can do by bridging your head receiver from L2 post to No. 2 and No. 3

terminals of the induction coil successively; you should get strong

battery on No. 2 terminal, if the relay is all right and a strong

condenser discharge when you make contact, but a weak battery click

when you break contact, on No. 3 terminal.

A ground on the ground side of the line may also prevent the relay from

operating, by carrying the generator current off to ground before it

reaches the instrument.

If the relay is held up, usually the lamp is kept burning at the

central office also, and this means that current is flowing from the

central office over the battery side of the line, passing through

the relay winding, and returning to the central office over the

ground side of the line, or through the ground wire and ground. This

condition may be due to:

1st. Winding of relay crossed with frame. Test by disconnecting the “A”

or “B” terminals of the ringer from L2 which should release the relay.

2d. As in the case of current through the ringer of a straight set,

the trouble may be caused by receiver contact of hook not breaking,

white and green strands of desk stand cord crossed together, condenser

short-circuited. Test as though it was a straight set.

[Illustration: Fig. 3.]

If the relay vibrates continuously the winding is probably crossed with

the frame. To find out whether this is the case, disconnect the ground

wire, which should stop the vibrating.

If the relay “jumps” while the operator is ringing, instead of pulling

up and staying up as long as the ringing current continues, the relay

may be weak, due to a part of the winding being short-circuited out,

or to some other cause; or there may be too many bells and relays on

the line, so that, owing to the resistance of the line, not enough

generator current will flow over it to divide up and give each bell and

relay a proper amount of current; or there may be a slight ground on

the line, which carries off a part of the ringing current.

To prove that a relay is all right:

1. Short-circuit the condenser; this should hold up the relay, by

putting battery current through it.

2. Prove that the spring contact is not crossed with the frame as

follows: Disconnect “A” and “B”, then connect the frame of the

relay to battery with a test cord, and bridge from the spring

contact to ground with your head receiver; if you get no current

there is no cross.

3. Prove that the winding is not crossed with the frame as follows:

Disconnect “A” and “B” and then test with your head receiver from

the frame to the L2 posts; if you get no battery there is no cross.

=Ringer=: If the relay comes up, but the bell does not ring, the

trouble may be due to:

Ringer poled wrong.

Bias spring too tight or too loose.

Ringer open.

Ground open.

Ringer short-circuited.

Bridging your head receiver across the ringer while the operator is

ringing will show whether or not you are getting generator current on

the terminals of the ringer winding; going in series at the “A” and “B”

terminal will show whether or not you are getting current through the

ringer.

To prove whether a ringer is open or not, connect “A” to battery, hold

the relay closed, and then test from “B” to ground with your head

receiver; if you get no current the circuit is open; prove that the

open is in the ringer itself by testing direct from the two terminals

of the winding successively.

The ground can be tested in the same manner as on a two-party set.

To prove that the ringer is short-circuited, connect “A” and “B” across

the line, close the relay contact, and bridge across the terminals of

the ringer winding with your head receiver; if you get no click the

ringer must be short circuited; check this test by putting your head

receiver in series with the ringer, while it is connected across the

line, and closing the relay contact; this should give you a strong

click if the ringer is short-circuited.

=Bell ringing weak may be due to=:

Poor adjustment of armature.

Poor adjustment of bias spring.

Pivot screw too loose or too tight.

Clapper rubbing on guard.

Wiring interfering with clapper stem.

“Whiskers” on magnet head.

Magnet head sticky or gummy.

Polarizing magnet weak.

One or both coils of ringer partially short-circuited.

Too many bells and relays on the line.

Ground on one side of line which takes part of the generator current

off to ground before it reaches the instrument.

Trouble at central office.

Earth currents.

To test for earth currents bridge your head receiver from the ground

side of the line to the ground; you should get no current; if you do

get current you will probably find that it varies continually, being

due to trolley cars; report the matter to the chief inspector. In

making this test be sure that the line is not in use; if the receiver

is off the hook at any station on the line you will get a false test.

Earth currents very often cause bell troubles on suburban stations,

particularly those that lie near to trolley lines; but in the city,

earth currents are seldom noticeable.

=False rings may be caused by=:

Very strong earth currents.

One coil of ringer short-circuited.

If a biased ringer has one coil short-circuited, then when it is poled

for either 1st or 2d stations it will respond to both rings; and

likewise when poled for 3d or 4th stations it will ring with either

current.

In the bell diagram No. 3 you will see that “B” connects to the spring

contact of the relay, the frame of the relay connects to the biased

side of the ringer, and the unbiased side of the ringer connects to “A.”

In the older bells, “B” connects direct to the biased side of the

ringer; the unbiased side of the ringer connects to the spring contact

of the relay, and the frame of the relay connects to “A.”

Therefore, in connecting an extension bell to a set that has no

extension bell binding posts, connect one side of the wire to the frame

screw of the relay, under the bottom of the set, and the other side to

the post at the top of the bell that “A” connects with. Or solder one

of the extension bell wires to the spring contact of the relay, and

connect the other to the post at the top of the bell that “B” connects

with. In every case the auxiliary bell must be connected across the

terminals of the ringer without being bridged around the break of the

relay. Pole the extension bell by reversing the wires either at the

bell or at the set.

=Ringer Adjustments=: In adjusting a biased ringer find out the two

points where the bell ceases to ring on account of the bias spring

being too tight and too loose, and adjust the spring half way between

these points. To locate them, slack off the bias spring until it has

no tension at all, and then get the operator to ring while you tighten

up the spring, and note the point at which the bell commences to ring;

continue to tighten the spring until the bell ceases to ring; by making

the adjustment half-way between these two limits, you will have a

margin both ways, so that if the generator rises a little above or

falls a little below its proper voltage, the bell will still ring.

The little set screw in the yoke at one end of the armature should be

adjusted so as to hold the opposite or bias spring end of the armature

a little away from the head of the magnet core; 0.02 of an inch, which

is a little less than the diameter of a No. 22 cross-connecting wire,

“In every test use a little judgment.”