PORTABLE OXYGEN EQUIPMENT

A PORTABLE RECHARGER HOSE is available at every station in the ship.

Every crew member should know their location so well that they can be

located immediately, even on the darkest night. In addition, there is a

long recharger hose for filling the ball turret oxygen cylinder.

(B-17-F).

When drawing oxygen through a portable recharger the refiller valve

must engage the filler nozzle TIGHTLY, otherwise oxygen leaks around the

connection and is lost. The oxygen supply of an entire system has been

wasted in this manner.

FREEZING or STICKING of refiller valve is not uncommon at extremely

low temperatures. Always check this after refilling your walk-around. A

stuck valve will quickly deplete the entire supply of oxygen in that

system. If the valve is stuck plug in a walk-around bottle and leave it

there.

USES OF THE WALK-AROUND BOTTLE -- (1) As an ACCESSORY REGULATOR --

the A-13 regulator on the walk-around bottle is a demand type regulator

without the "auto-mix" feature. It gives 100% oxygen on inspiration

regardless of the altitude. By connecting the walk-around bottle FIRMLY

into the portable recharger valve, one has an extra source of oxygen at

that particular station. As long as the oxygen gauge at the station

registers oxygen pressure the user is assured a supply of pure oxygen

... his supply is coming directly from the system. Remember this when

reviving a passed out crew mate in the waist in the vicinity of the ball

turret--the long recharger hose used to charge the oxygen bottle on the

ball turret can be plugged directly into a walk-around bottle attached

to the unconscious crew member's mask.

If other long recharger hoses can be obtained from Tech Supply they

will be extremely handy attached at the pilots station, in the bomb bay

and to the recharger outlet at the right waist gunner's station. This

would permit the engineer, who in flight is continuously filling his

walk-around bottle, considerable liberty. He could cover most of the

ship, staked out on a long recharger hose connected to his walk-around

bottle. It would also provide a readily accessible source of oxygen to

revive crew members who pick such out-of-the-way places to pass out as:

the bomb bay cat-walk, the bomb bay doors, under the flight deck, or in

some remote part of the waist.

One or two extension portable recharger hoses shown in photograph

page 22 should be standard equipment in heavy bombers.

[Illustration: Fig. 5 EXTENSION RECHARGER HOSE]

(2) SOURCE OF OXYGEN FOR BAIL-OUT -- Above 20,000 feet, breathing of

oxygen is necessary to reach your particular escape hatch. After this

spot is gained you won't need oxygen ... unless you start fiddling with

the rip-cord too soon. Go to your exit on the walk-around bottle, fill

your lungs deeply five or six times from the bottle, HOLD YOUR BREATH,

and take the dive. Continue to hold your breath during the descent as

long as possible. By the time your lungs are bursting for air you'll be

from 8 to 10,000 feet nearer the ground and won't need extra oxygen.

Leave the mask on--it will protect your face. If the skies are filled

with enemy planes it may be wise to continue the free fall. By now you

can start breathing without danger of serious oxygen-lack. Any dimming

of mental acuity would be of such short duration that you'd have plenty

of time to pull the ripcord.

PRACTICE GOING TO YOUR ESCAPE HATCH ON A WALK-AROUND BOTTLE DURING

OPERATIONAL TRAINING -- PRACTICE ON JUST HOW YOU WOULD CLEAR THE SHIP --

GO THROUGH ALL OF THE ROUTINE EXCEPT THE BAILOUT and that might not be

time wasted, at least just once before the time comes when you might

have to!

Above 30,000 feet you wouldn't want to open your 'chute even if you

had plenty of oxygen. You'd freeze a hand or foot or both if you did.

Under these conditions you'd free fall, holding your breath, as long as

possible. Then, after three or four breaths of "thin" air, pull the rip

cord. Your altitude should be in the vicinity of 10,000 to 12,000 feet

below that when you abandoned ship, and the degree of oxygen-lack

encountered here wouldn't be of dangerous consequence. You'll avoid

freezing, and perhaps the gunfire of enemy interceptors.

(3) TO MOVE ABOUT THE SHIP For this the walk-around bottle is very

useful ... and very tricky! The trouble is that the thing is good only

as long as it gives oxygen. It will rarely, if ever, be fully charged so

forget that 8 to 12 minute stuff. You can't fill your bottle any fuller

than the pressure in the line you'll be drawing from. And the only time

that will be fully charged is when the ship is on the ground, freshly

charged with oxygen, ready for the take-off. When you need the

walk-around bottle, three or four hours will have passed ... and the

pressure in your filling line will be some fraction of the full charge.

As a rule you'll do well to get the bottle half charged. And you're

going to be moving about at altitude and needing 3 to 5 times as much

oxygen as if you were sitting quietly in a corner. So plan on the

walk-around supply lasting 1½ to 2 minutes ... then you won't be caught

short Refill the bottle frequently. Refill it every time you pass a

portable recharger hose ... and there's one at every station. Failure

to do this has caused more pass-outs in second and third phase training

than any other single cause ... unless you include carelessness. And

careless people don't last long in the kind of work you're specializing

in! There's a check-valve on the walk-around bottle, so you won't lose

anything if you plug into a system that reads less than the gauge on the

bottle.

NOTE TO ENGINEERS: Because of its limited supply, the standard

walk-around bottle is next to useless for many of your jobs which must

be done in flight on a walk-around bottle. The ENGINEER NEEDS A LARGER

WALK-AROUND BOTTLE. One, having a supply 5 TIMES AS GREAT as the

standard portable cylinder, can be obtained as follows:

Obtain a D-2 oxygen cylinder (stock No. 5500-344020 - class 03K)

from Air Corps Supply. Remove the A-13 regulator assembly from a

standard walk-around bottle. Remove the spud from one end of the D-2

cylinder and screw the A-13 regulator in tightly. Fill to 400 p.s.i. and

leave overnight to determine if pressure is maintained or lost due to a

leak. (A drop of 25 to 50 pounds will occur in the absence of a leak due

to cooling of the oxygen which warmed up when the cylinder was charged).

[Illustration: Fig. 6 D-2 WALK-AROUND BOTTLE]

For leaks here or elsewhere in an oxygen system use the following

anti-sieze and sealing compound on the pipe threads: Pioneer Antisieze

No. 2., Class 96B, Stock no. 7500-050800. Never use a sealing compound

which contains oil.

A satisfactory bag with shoulder strap for carrying the walk-around

bottle when in use can be made from heavy twill or canvas by the

parachute department.

Survival at Altitude for Heavy and Very Heavy Bomber Crews · 第 17 / 78 题