THE DEMAND (A-12) REGULATOR

In principle the demand regulator is a diaphragm-operated flow valve

which is opened by the user's inspiration and closes automatically when

the suction ceases. This gives you as much oxygen as you ask for. All

you do is breathe. A short breath draws a short squirt of oxygen, while

deep, rapid breathing brings forth large shots in rapid succession.

The regulator can be set to conserve oxygen, or to give you 100%

oxygen, regardless of the altitude you are flying. This is governed by

the position of the "Auto-Mix" (AIR) lever.

AUTO-MIX (AIR) "ON" (or NORMAL OXYGEN) is the position for routine

use. This saves oxygen.

(1) Gives a mixture of air and oxygen:

10,000 feet -- approx. 30% oxygen

18,000 feet -- approx. 65% oxygen

26,000 feet -- approx. 85% oxygen

30,000 feet -- approx. 100% oxygen

Under the above conditions, so far as oxygen is concerned, you are

at ground level.

(2) Use oxygen from ground level on night missions to prevent night

blindness.

(3) Increased altitude increases oxygen supply AUTOMATICALLY.

(4) Percentage of oxygen delivered keeps you at ground level efficiency.

(5) Ships oxygen supply, charged to 450 pounds lasts 10 men from 7 to 9

hours. (20,000 to 30,000 feet).

AUTO-MIX (AIR) "OFF (or 100% oxygen) -- used when ordered by first

pilot, and on special occasions.

(1) Gives 100% oxygen, on demand, regardless of altitude.

(2) Used on special occasions:

(a) To casualties suffering from:

1. Loss of blood.

2. Shock.

3. Passing out from oxygen lack (revived).

(b) Regulator not giving enough oxygen in "ON" position (blue

finger nails-beginning to feel pleased with yourself).

(c) To avoid gas poisoning if you land in a gassed area without gas

masks.

(d) To flush nitrogen gas from body fluids when going above 30,000

feet, helping to prevent bends.

(3) Ship's oxygen supply, charged to 450 pounds, lasts 6 hours or less.

THE "EMERGENCY" VALVE IS DANGEROUS -- it should be used with extreme

caution. A whole system can be depleted of oxygen in an hour or less if

the "emergency" is opened only a quarter of a turn. Emergency "ON"

changes regulator into a constant flow system and wastes precious

oxygen. Use only to revive an unconscious crew member or to check line

to make sure it is clear. Always make sure that "Emergency" is TIGHTLY

TURNED OFF before ship leaves the ground.

NOTE:

Don't be confused by the difference in appearance of demand

regulators manufactured by various companies (see Fig. 9). THEY ALL

WORK THE SAME.