COST OF EVAPORATION

40 Cost of coal per ton of......pounds delivered in boiler room......dollars

41 Cost of coal required for evaporating 1000 pounds of water

from and at 212 degrees........................................dollars

[Illustration: Portion of 3600 Horse-power Installation of Babcock &

Wilcox Boilers, Equipped with Babcock & Wilcox Chain Grate Stokers at

the Loomis Street Plant of the Peoples Gas Light & Coke Co., Chicago,

Ill. This Company has Installed 7780 Horse Power of Babcock & Wilcox

Boilers]

THE SELECTION OF BOILERS WITH A CONSIDERATION OF THE FACTORS DETERMINING

SUCH SELECTION

The selection of steam boilers is a matter to which the most careful

thought and attention may be well given. Within the last twenty years,

radical changes have taken place in the methods and appliances for the

generation and distribution of power. These changes have been made

largely in the prime movers, both as to type and size, and are best

illustrated by the changes in central station power-plant practice. It

is hardly within the scope of this work to treat of power-plant design

and the discussion will be limited to a consideration of the boiler end

of the power plant.

As stated, the changes have been largely in prime movers, the steam

generating equipment having been considered more or less of a standard

piece of apparatus whose sole function is the transfer of the heat

liberated from the fuel by combustion to the steam stored or circulated

in such apparatus. When the fact is considered that the cost of steam

generation is roughly from 65 to 80 per cent of the total cost of power

production, it may be readily understood that the most fruitful field

for improvement exists in the boiler end of the power plant. The

efficiency of the plant as a whole will vary with the load it carries

and it is in the boiler room where such variation is largest and most

subject to control.

The improvements to be secured in the boiler room results are not simply

a matter of dictation of operating methods. The securing of perfect

combustion, with the accompanying efficiency of heat transfer, while

comparatively simple in theory, is difficult to obtain in practical

operation. This fact is perhaps best exemplified by the difference

between test results and those obtained in daily operation even under

the most careful supervision. This difference makes it necessary to

establish a standard by which operating results may be judged, a

standard not necessarily that which might be possible under test

conditions but one which experiment shows can be secured under the very

best operating conditions.

The study of the theory of combustion, draft, etc., as already given,

will indicate that the question of efficiency is largely a matter of

proper relation between fuel, furnace and generator. While the

possibility of a substantial saving through added efficiency cannot be

overlooked, the boiler design of the future must, even more than in the

past, be considered particularly from the aspect of reliability and

simplicity. A flexibility of operation is necessary as a guarantee of

continuity of service.

In view of the above, before the question of the selection of boilers

can be taken up intelligently, it is necessary to consider the subjects

of boiler efficiency and boiler capacity, together with their relation

to each other.

The criterion by which the efficiency of a boiler plant is to be judged

is the cost of the production of a definite amount of steam. Considered

in this sense, there must be included in the efficiency of a boiler

plant the simplicity of operation, flexibility and reliability of the

boiler used. The items of repair and upkeep cost are often high because

of the nature of the service. The governing factor in these items is

unquestionably the type of boiler selected.

The features entering into the plant efficiency are so numerous that it

is impossible to make a statement as to a means of securing the highest

efficiency which will apply to all cases. Such efficiency is to be

secured by the proper relation of fuel, furnace and boiler heating

surface, actual operating conditions, which allow the approaching of the

potential efficiencies made possible by the refinement of design, and a

systematic supervision of the operation assisted by a detailed record of

performances and conditions. The question of supervision will be taken

up later in the chapter on "Operation and Care of Boilers".

The efficiencies that may be expected from the combination of

well-designed boilers and furnaces are indicated in Table 59 in which

are given a number of tests with various fuels and under widely

different operating conditions.

It is to be appreciated that the results obtained as given in this table

are practically all under test conditions. The nearness with which

practical operating conditions can approach these figures will depend

upon the character of the supervision of the boiler room and the

intelligence of the operating crew. The size of the plant will

ordinarily govern the expense warranted in securing the right sort of

supervision.

The bearing that the type of boiler has on the efficiency to be expected

can only be realized from a study of the foregoing chapters.

Capacity--Capacity, as already defined, is the ability of a definite

amount of boiler-heating surface to generate steam. Boilers are

ordinarily purchased under a manufacturer's specification, which rates a

boiler at a nominal rated horse power, usually based on 10 square feet

of heating surface per horse power. Such a builders' rating is

absolutely arbitrary and implies nothing as to the limiting amount of

water that this amount of heating surface will evaporate. It does not

imply that the evaporation of 34.5 pounds of water from and at 212

degrees with 10 square feet of heating surface is the limit of the

capacity of the boiler. Further, from a statement that a boiler is of a

certain horse power on the manufacturer's basis, it is not to be

understood that the boiler is in any state of strain when developing

more than its rated capacity.

Broadly stated, the evaporative capacity of a certain amount of heating

surface in a well-designed boiler, that is, the boiler horse power it is

capable of producing, is limited only by the amount of fuel that can be

burned under the boiler. While such a statement would imply that the

question of capacity to be secured was simply one of making an

arrangement by which sufficient fuel could be burned under a definite

amount of heating surface to generate the required amount of steam,

there are limiting features that must be weighed against the advantages

of high capacity developed from small heating surfaces. Briefly stated,

these factors are as follows:

1st. Efficiency. As the capacity increases, there will in general be a

decrease in efficiency, this loss above a certain point making it

inadvisable to try to secure more than a definite horse power from a

given boiler. This loss of efficiency with increased capacity is treated

below in detail, in considering the relation of efficiency to capacity.

2nd. Grate Ratio Possible or Practicable. All fuels have a maximum rate

of combustion, beyond which satisfactory results cannot be obtained,

regardless of draft available or which may be secured by mechanical

means. Such being the case, it is evident that with this maximum

combustion rate secured, the only method of obtaining added capacity

will be through the addition of grate surface. There is obviously a

point beyond which the grate surface for a given boiler cannot be

increased. This is due to the impracticability of handling grates above

a certain maximum size, to the enormous loss in draft pressure through a

boiler resulting from an attempt to force an abnormal quantity of gas

through the heating surface and to innumerable details of design and

maintenance that would make such an arrangement wholly unfeasible.

3rd. Feed Water. The difficulties that may arise through the use of poor

feed water or that are liable to happen through the use of practically

any feed water have already been pointed out. This question of feed is

frequently the limiting factor in the capacity obtainable, for with an

increase in such capacity comes an added concentration of such

ingredients in the feed water as will cause priming, foaming or rapid

scale formation. Certain waters which will give no trouble that cannot

be readily overcome with the boiler run at ordinary ratings will cause

difficulties at higher ratings entirely out of proportion to any

advantage secured by an increase in the power that a definite amount of

heating surface may be made to produce.

Where capacity in the sense of overload is desired, the type of boiler

selected will play a large part in the successful operation through such

periods. A boiler must be selected with which there is possible a

furnace arrangement that will give flexibility without undue loss in

efficiency over the range of capacity desired. The heating surface must

be so arranged that it will be possible to install in a practical

manner, sufficient grate surface at or below the maximum combustion rate

to develop the amount of power required. The design of boiler must be

such that there will be no priming or foaming at high overloads and that

any added scale formation due to such overloads may be easily removed.

Certain boilers which deliver commercially dry steam when operated at

about their normal rated capacity will prime badly when run at overloads

and this action may take place with a water that should be easily

handled by a properly designed boiler at any reasonable load. Such

action is ordinarily produced by the lack of a well defined, positive

circulation.

Relation of Efficiency and Capacity--The statement has been made that in

general the efficiency of a boiler will decrease as the capacity is

increased. Considering the boiler alone, apart from the furnace, this

statement may be readily explained.

Presupposing a constant furnace temperature, regardless of the capacity

at which a given boiler is run; to assure equal efficiencies at low and

high ratings, the exit temperature in the two instances would

necessarily be the same. For this temperature at the high rating, to be

identical with that at the low rating, the rate of heat transfer from

the gases to the heating surfaces would have to vary directly as the

weight or volume of such gases. Experiment has shown, however, that this

is not true but that this rate of transfer varies as some power of the

volume of gas less than one. As the heat transfer does not, therefore,

increase proportionately with the volume of gases, the exit temperature

for a given furnace temperature will be increased as the volume of gases

increases. As this is the measure of the efficiency of the heating

surface, the boiler efficiency will, therefore, decrease as the volume

of gases increases or the capacity at which the boiler is operated

increases.

Further, a certain portion of the heat absorbed by the heating surface

is through direct radiation from the fire. Again, presupposing a

constant furnace temperature; the heat absorbed through radiation is

solely a function of the amount of surface exposed to such radiation.

Hence, for the conditions assumed, the amount of heat absorbed by

radiation at the higher ratings will be the same as at the lower ratings

but in proportion to the total absorption will be less. As the added

volume of gas does not increase the rate of heat transfer, there are

therefore two factors acting toward the decrease in the efficiency of a

boiler with an increase in the capacity.