Diagonal Lines Represent Per Cent Efficiency]

Boiler efficiencies will vary over a wide range, depending on a great

variety of factors and conditions. The highest efficiencies that have

been secured with coal are in the neighborhood of 82 per cent and from

that point efficiencies are found all the way down to below 50 per cent.

Table 59[57] of tests of Babcock & Wilcox boilers under varying

conditions of fuel and operation will give an idea of what may be

obtained with proper operating conditions.

The difference between the efficiency secured in any boiler trial and

the perfect efficiency, 100 per cent, includes the losses, some of which

are unavoidable in the present state of the art, arising in the

conversion of the heat energy of the coal to the heat energy in the

steam. These losses may be classified as follows:

1st. Loss due to fuel dropped through the grate.

2nd. Loss due to unburned fuel which is carried by the draft, as small

particles, beyond the bridge wall into the setting or up the stack.

3rd. Loss due to the utilization of a portion of the heat in heating the

moisture contained in the fuel from the temperature of the atmosphere to

212 degrees; to evaporate it at that temperature and to superheat the

steam thus formed to the temperature of the flue gases. This steam, of

course, is first heated to the temperature of the furnace but as it

gives up a portion of this heat in passing through the boiler, the

superheating to the temperature of the exit gases is the correct degree

to be considered.

4th. Loss due to the water formed and by the burning of the hydrogen in

the fuel which must be evaporated and superheated as in item 3.

5th. Loss due to the superheating of the moisture in the air supplied

from the atmospheric temperature to the temperature of the flue gases.

6th. Loss due to the heating of the dry products of combustion to the

temperature of the flue gases.

7th. Loss due to the incomplete combustion of the fuel when the carbon

is not completely consumed but burns to CO instead of CO_{2}. The CO

passes out of the stack unburned as a volatile gas capable of further

combustion.

8th. Loss due to radiation of heat from the boiler and furnace settings.

Obviously a very elaborate test would have to be made were all of the

above items to be determined accurately. In ordinary practice it has

become customary to summarize these losses as follows, the methods of

computing the losses being given in each instance by a typical example:

(A) Loss due to the heating of moisture in the fuel from the atmospheric

temperature to 212 degrees, evaporate it at that temperature and

superheat it to the temperature of the flue gases. This in reality is

the total heat above the temperature of the air in the boiler room, in

one pound of superheated steam at atmospheric pressure at the

temperature of the flue gases, multiplied by the percentage of moisture

in the fuel. As the total heat above the temperature of the air would

have to be computed in each instance, this loss is best expressed by: