Correction = 313 - 303 = 10 degrees

The chart may be used in the determination of the correct reading of

moisture percentage and the permanent radiation correction for the

instrument used without computation as follows: Assume the same trial

pressure, feed temperature and normal reading as above. If the normal

reading is found to be 303 degrees, the correction for thermometer and

radiation will be the theoretical reading for dry steam as found from

the chart, less this normal reading, or 10 degrees correction. The

correct temperature for the trial in question is, therefore, 305

degrees. The moisture corresponding to this temperature and 180 pounds

gauge pressure will be found from the chart to be 0.45 per cent.

[Illustration: Fig. 16. Compact Throttling Calorimeter]

There are many forms of throttling calorimeter, all of which work upon

the same principle. The simplest one is probably that shown in Fig. 14.

An extremely convenient and compact design is shown in Fig. 16. This

calorimeter consists of two concentric metal cylinders screwed to a cap

containing a thermometer well. The steam pressure is measured by a gauge

placed in the supply pipe or other convenient location. Steam passes

through the orifice A and expands to atmospheric pressure, its

temperature at this pressure being measured by a thermometer placed in

the cup C. To prevent as far as possible radiation losses, the annular

space between the two cylinders is used as a jacket, steam being

supplied to this space through the hole B.

The limits of moisture within which the throttling calorimeter will work

are, at sea level, from 2.88 per cent at 50 pounds gauge pressure and

7.17 per cent moisture at 250 pounds pressure.

Separating Calorimeter--The separating calorimeter mechanically

separates the entrained water from the steam and collects it in a

reservoir, where its amount is either indicated by a gauge glass or is

drained off and weighed. Fig. 17 shows a calorimeter of this type. The

steam passes out of the calorimeter through an orifice of known size so

that its total amount can be calculated or it can be weighed. A gauge is

ordinarily provided with this type of calorimeter, which shows the

pressure in its inner chamber and the flow of steam for a given period,

this latter scale being graduated by trial.

The instrument, like a throttling calorimeter, should be well insulated

to prevent losses from radiation.

While theoretically the separating calorimeter is not limited in

capacity, it is well in cases where the percentage of moisture present

in the steam is known to be high, to attach a throttling calorimeter to

its exhaust. This, in effect, is the using of the separating calorimeter

as a small separator between the sampling nozzle and the throttling

instrument, and is necessary to insure the determination of the full

percentage of moisture in the steam. The sum of the percentages shown by

the two instruments is the moisture content of the steam.

The steam passing through a separating calorimeter may be calculated by

Napier's formula, the size of the orifice being known. There are

objections to such a calculation, however, in that it is difficult to

accurately determine the areas of such small orifices. Further, small

orifices have a tendency to become partly closed by sediment that may be

carried by the steam. The more accurate method of determining the amount

of steam passing through the instrument is as follows:

[Illustration: Fig. 17. Separating Calorimeter]

A hose should be attached to the separator outlet leading to a vessel of

water on a platform scale graduated to 1/100 of a pound. The steam

outlet should be connected to another vessel of water resting on a

second scale. In each case, the weight of each vessel and its contents

should be noted. When ready for an observation, the instrument should be

blown out thoroughly so that there will be no water within the

separator. The separator drip should then be closed and the steam hose

inserted into the vessel of water at the same instant. When the

separator has accumulated a sufficient quantity of water, the valve of

the instrument should be closed and the hose removed from the vessel of

water. The separator should be emptied into the vessel on its scale. The

final weight of each vessel and its contents are to be noted and the

differences between the final and original weights will represent the

weight of moisture collected by the separator and the weight of steam

from which the moisture has been taken. The proportion of moisture can

then be calculated from the following formula:

100 w

x = ----- (7)

W - w

Where x = per cent moisture in steam,

W = weight of steam condensed,

w = weight of moisture as taken out by the separating

calorimeter.

Sampling Nipple--The principle source of error in steam calorimeter

determinations is the failure to obtain an average sample of the steam

delivered by the boiler and it is extremely doubtful whether such a

sample is ever obtained. The two governing features in the obtaining of

such a sample are the type of sampling nozzle used and its location.

The American Society of Mechanical Engineers recommends a sampling

nozzle made of one-half inch iron pipe closed at the inner end and the

interior portion perforated with not less than twenty one-eighth inch

holes equally distributed from end to end and preferably drilled in

irregular or spiral rows, with the first hole not less than one-half

inch from the wall of the pipe. Many engineers object to the use of a

perforated sampling nipple because it ordinarily indicates a higher

percentage of moisture than is actually present in the steam. This is

due to the fact that if the perforations come close to the inner surface

of the pipe, the moisture, which in many instances clings to this

surface, will flow into the calorimeter and cause a large error. Where a

perforated nipple is used, in general it may be said that the

perforations should be at least one inch from the inner pipe surface.

A sampling nipple, open at the inner end and unperforated, undoubtedly

gives as accurate a measure as can be obtained of the moisture in the

steam passing that end. It would appear that a satisfactory method of

obtaining an average sample of the steam would result from the use of an

open end unperforated nipple passing through a stuffing box which would

allow the end to be placed at any point across the diameter of the steam

pipe.

Incidental to a test of a 15,000 K. W. steam engine turbine unit, Mr.

H. G. Stott and Mr. R. G. S. Pigott, finding no experimental data

bearing on the subject of low pressure steam quality determinations,

made a investigation of the subject and the sampling nozzle illustrated

in Fig. 18 was developed. In speaking of sampling nozzles in the

determination of the moisture content of low pressure steam, Mr. Pigott

says, "the ordinary standard perforated pipe sampler is absolutely

worthless in giving a true sample and it is vital that the sample be

abstracted from the main without changing its direction or velocity

until it is safely within the sample pipe and entirely isolated from the

rest of the steam."

[Illustration: Fig. 18. Stott and Pigott Sampling Nozzle]

It would appear that the nozzle illustrated is undoubtedly the best that

has been developed for use in the determination of the moisture content

of steam, not only in the case of low, but also in high pressure steam.

Location of Sampling Nozzle--The calorimeter should be located as near

as possible to the point from which the steam is taken and the sampling

nipple should be placed in a section of the main pipe near the boiler

and where there is no chance of moisture pocketing in the pipe. The

American Society of Mechanical Engineers recommends that a sampling

nipple, of which a description has been given, should be located in a

vertical main, rising from the boiler with its closed end extending

nearly across the pipe. Where non-return valves are used, or where there

are horizontal connections leading from the boiler to a vertical outlet,

water may collect at the lower end of the uptake pipe and be blown

upward in a spray which will not be carried away by the steam owing to a

lack of velocity. A sample taken from the lower part of this pipe will

show a greater amount of moisture than a true sample. With goose-neck

connections a small amount of water may collect on the bottom of the

pipe near the upper end where the inclination is such that the tendency

to flow backward is ordinarily counterbalanced by the flow of steam

forward over its surface; but when the velocity momentarily decreases

the water flows back to the lower end of the goose-neck and increases

the moisture at that point, making it an undesirable location for

sampling. In any case, it should be borne in mind that with low

velocities the tendency is for drops of entrained water to settle to the

bottom of the pipe, and to be temporarily broken up into spray whenever

an abrupt bend or other disturbance is met.

[Illustration: Fig. 19. Illustrating the Manner in which Erroneous

Calorimeter Readings may be Obtained due to Improper Location of Sampling

Nozzle

Case 1--Horizontal pipe. Water flows at bottom. If perforations

in nozzle are too near bottom of pipe, water piles against

nozzle, flows into calorimeter and gives false reading.

Case 2--If nozzle located too near junction of two horizontal

runs, as at a, condensation from vertical pipe which collects at

this point will be thrown against the nozzle by the velocity of

the steam, resulting in a false reading. Nozzle should be

located far enough above junction to be removed from water kept

in motion by the steam velocity, as at b. Case 3--Condensation

in bend will be held by velocity of the steam as shown. When

velocity is diminished during firing intervals and the like

moisture flows back against nozzle, a, and false reading is

obtained. A true reading will be obtained at b provided

condensation is not blown over on nozzle. Case 4--Where

non-return valve is placed before a bend, condensation will

collect on steam line side and water will be swept by steam

velocity against nozzle and false readings result.]

Fig. 19 indicates certain locations of sampling nozzles from which

erroneous results will be obtained, the reasons being obvious from a

study of the cuts.

Before taking any calorimeter reading, steam should be allowed to flow

through the instrument freely until it is thoroughly heated. The method

of using a throttling calorimeter is evident from the description of the

instrument given and the principle upon which it works.