TABLE 17

SAVING IN FUEL, IN PER CENT, BY HEATING FEED WATER

GAUGE PRESSURE 180 POUNDS

+-----------+-----------------------------------------+

| Initial | Final Temperature--Degrees Fahrenheit |

|Temperature|-----+-----+-----+-----+-----+-----+-----|

| Fahrenheit| 120 | 140 | 160 | 180 | 200 | 250 | 300 |

+-----------+-----+-----+-----+-----+-----+-----+-----+

| 32 | 7.35| 9.02|10.69|12.36|14.04|18.20|22.38|

| 35 | 7.12| 8.79|10.46|12.14|13.82|18.00|22.18|

| 40 | 6.72| 8.41|10.09|11.77|13.45|17.65|21.86|

| 45 | 6.33| 8.02| 9.71|11.40|13.08|17.30|21.52|

| 50 | 5.93| 7.63| 9.32|11.02|12.72|16.95|21.19|

| 55 | 5.53| 7.24| 8.94|10.64|12.34|16.60|20.86|

| 60 | 5.13| 6.84| 8.55|10.27|11.97|16.24|20.52|

| 65 | 4.72| 6.44| 8.16| 9.87|11.59|15.88|20.18|

| 70 | 4.31| 6.04| 7.77| 9.48|11.21|15.52|19.83|

| 75 | 3.90| 5.64| 7.36| 9.09|10.82|15.16|19.48|

| 80 | 3.48| 5.22| 6.96| 8.70|10.44|14.79|19.13|

| 85 | 3.06| 4.80| 6.55| 8.30|10.05|14.41|18.78|

| 90 | 2.63| 4.39| 6.14| 7.89| 9.65|14.04|18.43|

| 95 | 2.20| 3.97| 5.73| 7.49| 9.25|13.66|18.07|

| 100 | 1.77| 3.54| 5.31| 7.08| 8.85|13.28|17.70|

| 110 | .89| 2.68| 4.47| 6.25| 8.04|12.50|16.97|

| 120 | .00| 1.80| 3.61| 5.41| 7.21|11.71|16.22|

| 130 | | .91| 2.73| 4.55| 6.37|10.91|15.46|

| 140 | | .00| 1.84| 3.67| 5.51|10.09|14.68|

| 150 | | | .93| 2.78| 4.63| 9.26|13.89|

| 160 | | | .00| 1.87| 3.74| 8.41|13.09|

| 170 | | | | .94| 2.83| 7.55|12.27|

| 180 | | | | .00| 1.91| 6.67|11.43|

| 190 | | | | | .96| 5.77|10.58|

| 200 | | | | | .00| 4.86| 9.71|

| 210 | | | | | | 3.92| 8.82|

+-----------+-----+-----+-----+-----+-----+-----+-----+

Besides the saving in fuel effected by the use of feed water heaters,

other advantages are secured. The time required for the conversion of

water into steam is diminished and the steam capacity of the boiler

thereby increased. Further, the feeding of cold water into a boiler has

a tendency toward the setting up of temperature strains, which are

diminished in proportion as the temperature of the feed approaches that

of the steam. An important additional advantage of heating feed water is

that in certain types of heaters a large portion of the scale forming

ingredients are precipitated before entering the boiler, with a

consequent saving in cleaning and losses through decreased efficiency

and capacity.

In general, feed water heaters may be divided into closed heaters, open

heaters and economizers; the first two depend for their heat upon

exhaust, or in some cases live steam, while the last class utilizes the

heat of the waste flue gases to secure the same result. The question of

the type of apparatus to be installed is dependent upon the conditions

attached to each individual case.

In closed heaters the feed water and the exhaust steam do not come into

actual contact with each other. Either the steam or the water passes

through tubes surrounded by the other medium, as the heater is of the

steam-tube or water-tube type. A closed heater is best suited for water

free from scale-forming matter, as such matter soon clogs the passages.

Cleaning such heaters is costly and the efficiency drops off rapidly as

scale forms. A closed heater is not advisable where the engines work

intermittently, as is the case with mine hoisting engines. In this class

of work the frequent coolings between operating periods and the sudden

heatings when operation commences will tend to loosen the tubes or even

pull them apart. For this reason, an open heater, or economizer, will

give more satisfactory service with intermittently operating apparatus.

Open heaters are best suited for waters containing scale-forming matter.

Much of the temporary hardness may be precipitated in the heater and the

sediment easily removed. Such heaters are frequently used with a reagent

for precipitating permanent hardness in the combined heat and chemical

treatment of feed water. The so-called live steam purifiers are open

heaters, the water being raised to the boiling temperature and the

carbonates and a portion of the sulphates being precipitated. The

disadvantage of this class of apparatus is that some of the sulphates

remain in solution to be precipitated as scale when concentrated in the

boiler. Sufficient concentration to have such an effect, however, may

often be prevented by frequent blowing down.

Economizers find their largest field where the design of the boiler is

such that the maximum possible amount of heat is not extracted from the

gases of combustion. The more wasteful the boiler, the greater the

saving effected by the use of the economizer, and it is sometimes

possible to raise the temperature of the feed water to that of high

pressure steam by the installation of such an apparatus, the saving

amounting in some cases to as much as 20 per cent. The fuel used bears

directly on the question of the advisability of an economizer

installation, for when oil is the fuel a boiler efficiency of 80 per

cent or over is frequently realized, an efficiency which would leave a

small opportunity for a commercial gain through the addition of an

economizer.

From the standpoint of space requirements, economizers are at a

disadvantage in that they are bulky and require a considerable increase

over space occupied by a heater of the exhaust type. They also require

additional brickwork or a metal casing, which increases the cost.

Sometimes, too, the frictional resistance of the gases through an

economizer make its adaptability questionable because of the draft

conditions. When figuring the net return on economizer investment, all

of these factors must be considered.

When the feed water is such that scale will quickly encrust the

economizer and throw it out of service for cleaning during an excessive

portion of the time, it will be necessary to purify water before

introducing it into an economizer to make it earn a profit on the

investment.

From the foregoing, it is clearly indicated that it is impossible to

make a definite statement as to the relative saving by heating feed

water in any of the three types. Each case must be worked out

independently and a decision can be reached only after an exhaustive

study of all the conditions affecting the case, including the time the

plant will be in service and probable growth of the plant. When, as a

result of such study, the possible methods for handling the problem have

been determined, the solution of the best apparatus can be made easily

by the balancing of the saving possible by each method against its first

cost, depreciation, maintenance and cost of operation.

Feeding of Water--The choice of methods to be used in introducing feed

water into a boiler lies between an injector and a pump. In most plants,

an injector would not be economical, as the water fed by such means must

be cold, a fact which makes impossible the use of a heater before the

water enters the injector. Such a heater might be installed between the

injector and the boiler but as heat is added to the water in the

injector, the heater could not properly fulfill its function.