TABLE 2

COMPARATIVE APPROXIMATE FLOOR

SPACE OCCUPIED BY BABCOCK & WILCOX

AND H. R. T. BOILERS

+------------+----------------+---------------+

|Size of unit|Babcock & Wilcox| H. R. T. |

|Horse Power |Feet and Inches |Feet and Inches|

+------------+----------------+---------------+

| 100 | 7 3 × 19 9 | 10 0 × 20 0 |

| 150 | 7 10 × 19 9 | 10 0 × 22 6 |

| 200 | 9 0 × 19 9 | 11 6 × 23 10 |

| 250 | 9 0 × 19 9 | 11 6 × 23 10 |

| 300 | 10 2 × 19 9 | 12 0 × 25 0 |

+------------+----------------+---------------+

Steam, Its Generation and Use · 第 26 / 217 题