THE CALORIMETER CHAMBER.

[Illustration: FIG. 7.--Horizontal cross-section of chair calorimeter,

showing cross-section of copper wall at A, zinc wall at B, hair-felt at

E, and asbestos outer wall at F; also cross-section of all upright

channels in the steel construction. At the right is the location of the

ingoing and outgoing water and the thermometers. At C is shown the food

aperture, and D is a gasket separating the two parts. The ingoing and

outcoming air-pipes are shown at the right inside the copper wall. The

telephone is shown at the left, and in the center of the drawing is the

chair with its foot-rest, G. In dotted line is shown the opening where

the man enters.]

[Illustration: FIG. 8.--Vertical cross-section of chair calorimeter,

showing part of rear of calorimeter and structural-steel frame. N,

cross-section of bottom horizontal channel supporting asbestos floor J;

H, H, upright channels (at the right is a side upright channel and to

the left of this is an upright rear channel); M horizontal 8-inch

channel supporting calorimeter; Zn, zinc wall; Cu, copper wall; J,

insulating asbestos.]

The respiration chamber used in Middletown, Connecticut, was designed to

permit of the greatest latitude in the nature of the experiments to be

made with it. As a result, it was found at the end of a number of years

of experimenting that this particular size of chamber was somewhat too

small for the most satisfactory experiments during muscular work and, on

the other hand, somewhat too large for the best results during so-called

rest experiments. In the earlier experiments, where no attempt was made

to determine the consumption of oxygen, these disadvantages were not so

apparent, as carbon dioxide could be determined with very great

accuracy; but with the attempts to measure the oxygen it was found that

the large volume of residual air inside the chamber, amounting to some

4,500 liters, made possible very considerable errors in this

determination, for, obviously, the subject could draw upon the oxygen

residual in the air of the chamber, nearly 1,000 liters, as well as upon

the oxygen furnished from outside sources. The result was that a very

careful analysis of the residual air must be made frequently in order to

insure that the increase or decrease in the amount of oxygen residual in

the air of the chamber was known accurately at the end of each period.

Analysis of this large volume of air could be made with considerable

accuracy, but in order to calculate the exact total of oxygen residual

in the air it was necessary to know the total volume of air inside the

chamber under standard conditions. This necessitated, therefore, a

careful measurement of temperature and pressure, and while the

barometric pressure could be measured with a high degree of accuracy,

it was found to be very difficult to determine exactly the average

temperature of so large a mass of air. The difficulties attending this

measurement and experiments upon this point are discussed in detail

elsewhere.[5] Consequently, as a result of this experience, in planning

the calorimeters for the Nutrition Laboratory it was decided to design

them for special types of experiments. The first calorimeter to be

constructed was one which would have general use in experiments during

rest and, indeed, during experiments with the subject sitting quietly in

the chair.

[Illustration: FIG. 9.--Vertical cross-section of chair calorimeter from

front to back, showing structural steel supporting the calorimeter and

the large balance above for weighing the subject inside the calorimeter.

The chair, method of suspension, and apparatus for raising and lowering

are shown. Part of the heat-absorbers is shown, and their general

direction. The ingoing and outgoing air-pipes and direction of

ventilation are also indicated. The positions of the food-aperture and

wire mat and asbestos support are seen. Surrounding the calorimeter are

the asbestos outside and hair-felt lining.]

It may well be asked why the first calorimeter was not constructed of

such a type as to permit the subject assuming a position on a couch or

sofa, such as is used by Zuntz and his collaborators in their research

on the respiratory exchange, or the position of complete muscular rest

introduced by Johansson and his associates. While the body positions

maintained by Zuntz and Johansson may be the best positions for

experiments of short duration, it was found, as a result of a large

number of experiments, that subjects could be more comfortable and quiet

for periods of from 6 to 8 hours by sitting, somewhat inclined, in a

comfortable arm-chair, provided with a foot-rest. With this in mind the

first calorimeter was constructed so as to hold an arm-chair with a

foot-rest so adjusted that the air-space between the body of the subject

and the walls of the chamber could be cut down to the minimum and thus

increase the accuracy of the determination of oxygen. That the volume

has been very materially reduced may be seen from the fact that the

total volume of the first calorimeter to be described is less than 1,400

liters, or about one-third that of the Middletown apparatus.

Respiration Calorimeters for Studying the Respiratory Exchange and Energy Transformations of Man · 第 43 / 120 题