Spacebands travel through the machine suspended by their lugs.

Constant use causes the under side of the lug to wear, and when

spacebands with badly worn lugs are mixed together with new

spacebands, difficulty frequently arises and they occasionally clog

in the chute when released by touching the spacebar. The only remedy

is to send the offending spaceband to the factory to be repaired.

SPACEBAND BOX PAWLS AND RAILS

If the trouble is due to worn or dirty pawls, they can be taken out

in the following manner: Remove the spaceband box from the machine,

release the tension of the pawl springs by unscrewing the small screw

that holds the spring, then take out the pawl screw and lift the

pawl out of the box. If the pawls are to be replaced by new ones,

select two that are the same height. Test the pawls for height by

placing a small wooden plug in the pivot hole of the two pawls. The

points should be the same distance from the pivot holes. If the old

pawls are to be used, mark one pawl, so that they will not get mixed;

for after they have been used, they should be kept in their regular

place. Measure the pawls for height and also examine them to see

if the points are worn. If uneven and the points dull, they can be

rubbed down on an oil stone to get them even. After they are the same

height, sharpen them on an oil stone, being careful to maintain the

same bevel.

To work well, the pawls must be even as to height and at the points.

If the pawls are rusty or gummy they can be cleaned by rubbing them

on crocus cloth and polishing with graphite.

If the spaceband box rails are to be replaced with new ones, the box

must be taken apart. Remove the box from the machine. Remove the

chute plate. Drive out the taper pin which holds the pawl levers to

the lever shaft, and take off the levers. Take out the pawls, unscrew

the two large screws, and pry the two castings apart. Take off the

center bar plate by removing the two round head screws. Remove the

old rails. Put on the new ones by fitting them on the dowel pins,

using care to have the vertical face of the rails even. It is always

best to renew the pawls at the same time new rails are put on.

TO REPLACE SPACEBAND BOX PAWLS

To replace the spaceband box pawls, loosen the screw which holds

the pawl spring to the pawl lever, unscrew the lifting pawl screw,

place pawl in the box, screw up on the lifting screw, being careful

to guide the screw into the hole on the pawl. Place the spring in

the pawl slot before the pawl lift screw is drawn tight. Tighten

the spring screw, which holds the spring against the pawl, until the

screw is tight.

The pawl should rest against the back of the pawl guide firmly. Try

the pawl to see if the spring has the proper tension and that the

pawl is not bent so it does not work freely.

LINE DELIVERY SLIDE

The delivery slide consists of two slides which move in a slideway, a

long finger, short finger, delivery slide rod, and adjusting clamp.

The slide is connected by a lever link, lever, shaft, and split cam

lever, to a roller which operates against the surface of cam No. 10.

The slide gets its action, when delivering a line, from a strong coil

spring in the column of the machine which is connected to a lug on

the shaft. The slide is returned to normal by cam action, the roller

being held against and following the surface of cam No. 10.

When the line delivery slide is in normal position, it is prevented

from sliding into the first elevator jaws by the delivery pawl, which

is under the spaceband box, held to the face by a screw, and operated

by a spring.

This pawl has a notch on the lower side, which acts as a safety

to prevent the slide being pulled to the left, in case it is not

returned quite far enough for the end of the pawl to pass the catch.

When the slide has returned to normal position, the short finger

should go not more than 1/16 of an inch beyond the end of the pawl.

If the finger returns more than this distance, the short finger will

be forced against the spaceband box chute and cause it to spring, and

very likely cause delay in dropping of the spacebands.

The return adjustment is made by moving the split cam lever in or

out. First remove the spaceband box so as to have a clear view of the

pawl and finger. Then turn the main cams by hand until just before

the high part of cam No. 10 is opposite the split cam lever roller.

Place the short finger back of the delivery pawl, in normal position.

Hold the lever and roller against the cam and tighten the screws in

the split cam lever. This should cause the short finger on the slide

to be returned not more than 1/16 of an inch beyond the pawl.

This adjustment is approximate, however, due to wear on the

connecting parts of the slide on machines which have been in use for

some time. The adjustment is made on the older model machines, which

do not have the split cam lever, by the eccentric pin on the slide

lever.

Near the right end of the first elevator jaws are two spring pawls

which prevent the matrices from falling out while the line is going

to casting position. The short finger should stop 13/32 of an inch

inside of the first elevator. The last matrix on the right-hand end

of the line will then be inside the two pawls. This adjustment is

made by the screw in the slideway on the left end of the face plate,

against which the slide comes to a stop.

When the slide stops against the adjusting screw in the slideway, the

casting mechanism will be set in action. It is started by the roller

on the split cam lever, which comes in contact with the automatic

stopping pawl on cam No. 10, forcing it from the upper stopping

lever, and the machine goes into action. It should not start before

the line delivery slide has come to a stop against the adjusting

screw on the face plate. If it did, the last matrix in the line would

not be inside the spring pawls in the first elevator. The plate,

which is held to the automatic stopping pawl by a screw on the lower

end, is adjustable. Loosening the lower and turning the upper screw

to the left will move the plate closer to the split lever or roller

and the machine will be set in action sooner; moving the screw to the

right, the reverse. This plate should be adjusted so as to knock the

automatic stop pawl off upper stopping lever not less than 1/64 of an

inch.

The short finger is at the right of the slide and acts as a support

for the right end of the matrix line while it is being transferred to

the first elevator jaws. There is a small extension at the top of the

short finger which engages the delivery pawl and holds the slide in

normal position until the assembling elevator is raised to send in a

line. The short finger is not adjustable.

The long finger is fastened to the left of the slide. It is the

support for the left end of the matrix line while it is being

transferred to the vise jaws. The long finger is adjusted by means

of the clamp. It is necessary to readjust this finger when the

measure is changed. The long finger must be kept straight so it hangs

vertically on the machine. If bent either forward or backward it will

wear the assembling elevator. If the bottom is bent to the right, it

may interfere with the assembler slide, or the last matrix in the

line may not get inside the first elevator jaw pawls, thereby binding

the matrix. If bent to the left it will bind full lines of matrices

as they are being raised by the assembling elevator and cause the

slide to travel slowly.

The air chamber, which regulates the speed at which the slide

travels, is fastened to the rear of the column and is connected to

the split cam lever by means of a link. This link is also connected

to the delivery air cushion piston, which operates in the air

cylinder. As the slide moves over to the left this piston is forced

upward into the cylinder. The speed is regulated by an air vent and

cover at the top of the cylinder. Opening up the vent allows the air

to escape quicker which in turn allows the slide to move to the left

faster. The slide should not go over with too much force or it will

have a tendency to loosen the screws in the delivery slide.

The lever link, which is the connection between the delivery slide

and delivery lever, has a stud which fastens in a depression in the

delivery lever and is held by a small plate and two screws. The other

end of the lever has a notch that fits over a shoulder screw at the

left of the rear side of the delivery slide. The link is held on this

screw by means of a long, flat spring. The spring holds the link on

the screw except when there is an undue strain on the delivery slide

caused by something interfering with the free return of the slide.

When the strain becomes too great, the spring permits the link to

slip off the shoulder screw, disconnecting the slide from the lever

to prevent breakage. To connect the link it is only necessary to

relieve the strain on the delivery slide and push the link and the

shoulder screw together.

The slideway should be well lubricated at all times to prevent undue

wear on the sliding parts. Dry graphite will give more uniform action

than oil on the slideway. If oil has been used on the slideway, it

should be thoroughly cleaned before using graphite.

METAL POT

The metal pot consists of the pot jacket and pot crucible. The jacket

is the outside casting. The crucible fits into the jacket, allowing

space between the crucible and jacket for asbestos packing. The

crucible is held in place in the jacket by three lugs, which keep

it stationary in the jacket. All the space between the crucible and

jacket is packed tightly with powdered asbestos which has been mixed

with a little water until a paste is formed. This insulation is for

the purpose of holding the heat in the crucible.

It is very important that every pot should be well insulated or

packed. If there is poor packing the crucible can not hold the heat.

The result being poor slugs, and the consequent use of more gas than

is necessary. If the machine takes an excessive gas flame to keep the

metal in working condition, look for poor insulation.

The well of the pot, which contains the metal before it is forced

through the mouthpiece by the plunger, must have sufficient metal

under the plunger to form a perfect slug when a cast is made. For

that reason two holes are drilled in the well, one on each side,

which allows the metal to enter the well. If the holes become closed,

which they sometimes do if the well is not cleaned regularly, the

slug will be hollow. They should be kept open, using the end of the

mouthpiece wiper, which is bent at a right angle and pointed. The

metal pot has a capacity of 38 pounds of metal.

METAL POT PLUNGER

The metal is forced by the plunger from the well, through the throat

of the crucible, into the mold cell, and up against the line of

matrices aligned in front of the mold.

When the machine is in normal position, the plunger should be high

enough in the well to permit the metal to run into the well through

the holes in the sides. If the plunger does not set above the holes,

the metal can not flow into the well and throat, so when the line is

cast the slug will appear porous or spongy and of light weight.

If a plunger is worn, it will permit the metal to escape around the

sides of the plunger when the cast is made, giving a poor slug. To

remedy this trouble it is sometimes necessary to put in a new plunger

a trifle oversize (.005), and fit it to the well.

A dirty plunger may bind and cause a splash of metal to be ejected

before the pot locks up tight and, chilling on the back of the mold,

prevent a lockup, so the metal will flow out over the back of the

disk when the plunger acts. A dirty plunger will often cause a slug

to have the appearance of cold metal. Keep the plunger and the well

of the pot clean.

Any kind of a wire brush may be used to clean a plunger, but the

Ewald cleaning box is recommended, because it keeps all the dust

confined in the box. There are several kinds of brushes and scrapers

manufactured for use in cleaning the well. Use whatever method

desired, but be sure it keeps the well clean.

If using a rotary well brush to clean the walls of the well, be sure

to turn it always to the right, otherwise the bristles may break off

and stay in the well.

If a plunger should stick in the well very tightly, raise the

temperature a little, apply a wrench to the plunger rod and twist it

carefully. Do not use too much force or the rod may be broken. If a

plunger sticks so that it can not be removed by the above method, dip

enough metal out of the crucible to expose the well; squirt some oil

between the plunger and the inside wall of the well, or drop a piece

of tallow in the well; let it stand for a few minutes, after which

the plunger can usually be loosened with the wrench as described. Do

not pry up on the plunger for there is danger of breaking the rod.

When the plunger forces the metal through the throat of the crucible,

there will be nothing to retard the flow of metal against the face

of the matrices if the throat of the crucible is clean. However, if

the throat should be stopped up with dross or dirt, retarding the

flow of metal, the face of the slug would be glassy, and have the

appearance of cold metal.

CLEANING THE THROAT OF CRUCIBLE

To eliminate a stoppage in the throat it is sometimes necessary to

remove the mouthpiece and scrape out the throat, using a throat

scraper to cut away the accumulation of dirt and dross.

The scraper sold by the Linotype Company is recommended for the

purpose. Care must be used to get the throat clean. Hold a receptacle

that does not leak up in front of the crucible mouth and force the

plunger down by hand. This will flush the throat of any floating

particles of dross.

Sometimes melted tallow, paraffin oil, or machine oil will open up

the throat, by being used in the following manner: Dip the metal

out of the pot to about an inch below the top of the well, remove

the plunger, pour the melted tallow, paraffin oil, or machine oil

into the well and replace the plunger. Cast a few blank slugs. After

casting about six or seven slugs, fill the metal pot full of metal,

recast blank slugs until you have filled the stick. The effect of

the tallow or oil is to break up the dross and dirt into such fine

particles, that whatever has accumulated in the throat will be forced

out through the holes in the mouthpiece. This will cause considerable

smoke in the room unless you have a ventilating system. Be sure to

clean your vise jaws and mold after you have finished, for they will

be covered with oil. It is not necessary to remove the mouthpiece for

this operation so consequently considerable time can be saved. But if

the throat is very dirty, this method will not work satisfactorily.

CRACKED CRUCIBLE

Crucibles are sometimes cracked from too much heat when the gas is

first lighted. When the gas is turned on full at first, the metal in

the bottom of the pot is melted before the metal in the upper part

gets very hot. This metal in the bottom expands and powerful pressure

is exerted on the walls of the well and lower part of the crucible.

To eliminate this danger the gas should be turned on about half

force for about twenty minutes, or until the metal becomes warm and

expanded, after which the gas may be turned on full force.

Ordinarily it takes about one hour and a half to melt the metal and

have it ready for use. The small cracks which are made in the bottom

of the crucible when first heating the pot will usually be closed by

the heat of the burner after the pressure is released.

To remove an old crucible: Dip out as much metal as possible, turn

out the fire, remove the four pot jacket cover screws, take off

the cover, dig out part of the old asbestos, release the screw

that clamps the left-hand crucible lug to the jacket, lift out the

crucible, clean all of the old asbestos out of the inside of the

jacket.

To put in a new crucible: The pot jacket should be lined with the

asbestos about an inch thick on the inside, except in the front part

where the burners are located. Place the crucible in position. Care

should be taken to see that it fits firmly in its proper position.

Pack the asbestos around the crucible, tamping it down with a stick,

and filling in all the spaces. Cover the well of the crucible with

a rag while packing, so that none of the asbestos will get into the

well. On completion of the packing, place the pot jacket cover in

position, and fasten it down firmly with the four pot jacket screws,

which extend down through the cover, into the pot jacket.

MOUTHPIECES

One of the most important parts of the pot crucible, is the

mouthpiece. The mouthpiece on all standard machines contains thirty

holes (size 51), one hole for each pica of the slug, through which

the metal flows into the mold cell to form a slug.

At the present time there are two styles of mouthpieces in general

use: The wedge mouthpiece which has a gib or wedge to fasten it

in the slot of the crucible to make a tight fit; and the screw

mouthpiece which fastens on to the crucible by means of screws.

On all mouthpieces small cross vents are cut downward between each

of the holes. There is also a vent which is cut from the first hole

on the right-hand end of the mouthpiece. The cross vents allow the

air to escape from the mold cell as the metal is forced in. These

vents play a very important part in the casting of good slugs. If the

vents are stopped up with dross or cold metal, the air can not escape

from the mold cell. This causes a slug with air bubbles, making a

light-weight slug. These air bubbles, when near the face of the type,

allow the letters to be crushed in when put under pressure on the

press. Also, the entire slug may be forced down, causing much delay

in printing.

Care must be taken in cutting the vents in a mouthpiece so they do

not extend very far above the top of the holes in the mouthpiece and

that they are not too deep. They should be deep in the center and

come to a very fine edge at the ends. All that is needed is to get

the air out of the mold quickly. Ordinarily this can be accomplished

by cleaning the vents with a sharp pointed scraper but be careful

not to mar the mouthpiece. When the vents are opened properly there

should be a sprue of metal below the vents on the back of the mold

about ½ to ¾ of an inch long after the slug is cast.

A vent that is cut too deep will have too much sprue, causing an

unnecessary amount of shavings on the floor and about the machine,

and sometimes causing machine troubles.

It should seldom be necessary to drill out the holes in a mouthpiece.

If the metal is properly cared for in remelting, and the mouthpiece

is kept at the proper temperature, the metal will usually flow freely

through the holes. However, if it is found necessary to drill out

the holes, never use larger than a 1/16 inch or No. 51 drill, which

will not make the holes larger than their original size. When using

the drill, it should be immersed in oil after each hole is drilled,

to prevent the drill from becoming too hot and breaking off in the

hole. Enlarging the mouthpiece holes will work satisfactorily on

large faces 8-point or above; but when the smaller faces are used the

product will not have a clear-cut face.

TO REMOVE A MOUTHPIECE

When it is necessary to remove a mouthpiece for cleaning out the

throat of the crucible, mark a line on the face of the crucible to

align with the first hole on the right end of the mouthpiece. When

replacing the mouthpiece the line will be your guide. By so adjusting

there will be a full hole on each end of the slug when casting the

different lengths, with the exception of half-pica measures. A hole

on the adjustable or left end being partly covered by the liner in

the mold would cause no trouble. If part of the first hole should be

covered by the constant liner, the first letter on the right end of

the slug would be blurred, or would not cast sharply, because the

metal cools quickly on the ends of the mold, and a full, free flow is

necessary.

The mouthpiece should always be removed when the metal is hot. If

removed when cold there would be danger of breaking the pot crucible.

When removing the wedge style mouthpiece, place the vise in second

position, lift out the mold slide, place a block of wood between

the right side of the pot jacket and the slideway, drive the

mouthpiece toward the keyboard, using a piece of brass as a drift.

The above operation is necessary to loosen the wedge. The instant the

mouthpiece moves, the wedge will become loose and can be lifted out.

Another method of removal is to grip the left-hand end of the gib

with a pair of pliers, pulling the end of the gib forward and

wrapping it around the pliers, prying against a piece of brass rule

placed along the face of the mouthpiece. Care must be used in this

method to hold the pliers at such an angle that the lip of the

crucible will not be damaged while removing the gib.

Always have a new gib on hand before removing a mouthpiece, for it is

difficult to use an old one in replacing a mouthpiece.

In replacing an old mouthpiece, extreme care must be taken to see

that it is perfectly clean and straight. Clean the mouthpiece

thoroughly and with a straight-edge test the mouthpiece to see that

it is straight. If not, straighten it, being careful not to damage.

This need not be done with a new mouthpiece.

Before placing the mouthpiece in the crucible, remove the left-hand

vise locking stud nut and pull out the stud. Be careful not to lose

the small brass washer which is on the stud. The removal of the stud

permits the sliding in of the mouthpiece easily. The lips and the

slot of the crucible, which are the seat for the mouthpiece, must be

entirely free from all dirt and dross or the mouthpiece can not seat

properly.

It is best to fit a mouthpiece to its seat by placing a very thin

coating of fine emery and oil (fine valve grinding compound is good)

on the back and top part of the mouthpiece. This method cleans the

seat of all the accumulated dross and dirt. Place the mouthpiece in

position in the pot so the top of mouthpiece is against the top seat

and move back and forth, bearing lightly against the mouthpiece,

until the high spots are ground down, so as to have the seat

straight. When doing this, care must be taken not to get the paste

on any other part of the machine, as it might cause trouble. The

metal should be at casting temperature while fitting a mouthpiece.

To hold the mouthpiece for this operation, procure a piece of wood

furniture the same width and length of the mouthpiece, fasten this

to the mouthpiece by driving a headless brad in each end of the wood

directly in line with the last hole on each end of the mouthpiece.

By placing the wood on the mouthpiece the brads pass through the two

holes and make a very serviceable holder.

After fitting the mouthpiece, thoroughly clean all parts of the

crucible lip, slot, and mouthpiece. The least particle of grit may

cause trouble.

Fit the gib by dressing it, so that it will drive far enough to the

right to make a tight fit. Cover the top and bottom with a thin

coating of red lead and oil. Place the mouthpiece in position, the

first hole in line with the mark on the crucible. Insert the wedge

in the lower side and push it in as far as possible with a pair of

pliers. Then drive in the gib so as to secure the mouthpiece firmly.

Be careful that the mouthpiece does not move as the gib is being

driven in. Lay a brass rule against the whole length of the gib and

tap lightly with a hammer to firmly locate the gib on the seat, and

at the same time, bring the outer edge of the gib slightly below the

face of the mouthpiece.

After driving the mouthpiece to its proper position see that the

ends are not burred; if so, file them off, as they might prevent the

mouthpiece from locking up properly against the mold, and cause a

back squirt.

The screw mouthpiece is held to the crucible by 13 screws. The screw

holes in the mouthpiece are counter-sunk so the heads of these screws

will not extend beyond the face of the mouthpiece.

To remove the screw style mouthpiece from the crucible, use the pot

mouth screw loosener obtainable from the Linotype Company. Fit the

loosener in the groove of the screw and tap the head with a hammer.

As the screws will be tight, due to the heat and dross, this tapping

will loosen them without damaging the screw heads. The screws can

then be removed with a screw-driver.

Some features of the new mouthpiece are: There is no danger of

breaking the lips of the crucible by driving the wedge in too far;

it also eliminates the possibilities of battering the ends of the

mouthpiece, as with the wedge style; leaking around the mouthpiece

and improper setting when taken off and replaced is less likely to

occur.

Linotype mechanism · 第 3 / 12 段