Marine. Single internal fire grate, with small return tube, 7ft. 9in.

long, 5ft. 4in. diameter, 3/8 inch plates, tube 2ft. 7in. diameter, 1/4

inch plates, 62 lbs. pressure. Tube collapsed and rent open owing to

its weak, corroded, and deteriorated condition, and the contents issued

so violently, as to cause much damage to the boat.

_No. 17. Hull. (Fig. 10.) May 12th. 2 killed, 2 injured._

[Illustration: _Fig. 10._]

One of two. Plain Cylinder, 4ft. 9in. long, 3ft. diameter, 1/4 inch

plates, 25 lbs. pressure. This was a second-hand boiler, and rent into

several pieces just after being put to work, owing to its having become

thinned to 1/8 inch by corrosion.

_No. 18. Coatbridge. May 15th. 1 injured._

Plain Cylinder, flat ends, 15ft. long, 5ft. diameter, 3/8 inch plates,

30 lbs. pressure. The back end blew out and caused considerable

damage, and the boiler was thrown some distance. The end was very

insufficiently stayed.

_No. 19. Gravesend. (Fig. 11.) May 28th. 2 killed._

[Illustration: _Fig. 11._]

One of two. Marine, 13ft. 5in. long, 7ft. 2in. diameter, 5/16 inch

plates, 25 lbs. pressure. The fire was in two internal furnace tubes

united at the back, and the flame was returned to the front by four

smaller tubes. The furnace tubes were of exceedingly weak shape as

the sides followed the curve of the shell, but were not attached to

it by proper stays, so that the left hand tube collapsed upwards, and

one seam rent open and allowed the contents to violently escape. It

is probable there may have been greater pressure than usual at the

time, but the furnaces without stays were unsafe, even at the ordinary

pressure.

_No. 20. Durham. (Fig. 12.) June 8th. 2 killed._

[Illustration: _Fig. 12._]

One of eight. Plain Cylinder, 30ft. long, 6ft. diameter, 3/8 inch

plates, 35 lbs. pressure. The plates were arranged longitudinally.

Boiler had worked 27 years, and was much deteriorated, and gave way at

an old fracture over the grate, and was torn into 4 pieces, which were

thrown a great distance.

_No. 21. Huddersfield. (Fig. 13.) June 20th. 1 killed, 6 injured._

[Illustration: _Fig. 13._]

One tube Cornish, 24ft. long, 6ft. diameter. Tube 3ft. 3in. diameter,

3/8 inch plates, 40 lbs. pressure. The seams were arranged diagonally,

but the rents had not followed the seams, but had torn the plates. The

shell gave way where extensive corrosion had reduced the plates to 1/8

inch in thickness, and all the shell was blown off, and the tube thrown

over and turned end for end.

_No. 22. June 22nd. none injured._

Two tube Cornish, 27ft. long, 7ft. 6in. diameter. Tube 3ft. diameter,

7/16 inch plates, 70 lbs. pressure. Left hand tube collapsed from end

to end owing to its weakness without strengthening rings.

_No. 23. Halifax. July 9th. 6 injured._

Two tube Cornish, 20ft. long, 6ft. 3in. diameter. Tube 2ft. 3in.

diameter, 3/8 inch plates, 55 lbs. pressure. The shell was blown

completely off, leaving the tubes and ends intact. The bottom was

extensively corroded, so that the strength of the boiler was so reduced

as not to be able to bear the usual pressure.

_No. 24. Wrexham. (Fig. 14.) July 9th. 2 injured._

[Illustration: _Fig. 14._]

Two Furnace Upright, 22ft. high, 8ft. 10in. diameter, 3/8 inch plates,

14 lbs. pressure. Small piece was blown out of the bottom, and the

issuing contents disturbed the brickwork surrounding the boiler. The

plate was corroded to a knife edge in the line of fracture, from the

leaking of the adjacent blow-pipe joint.

_No. 25. Dundee. July 13th. 1 killed, 1 injured._

Two tube Cornish, 28ft. 6in. long, 7ft. diameter, 3/8 inch plates. Tube

2ft. 2in. diameter, 7/16 inch plates, 40 lbs. pressure. Both furnaces

collapsed, and ruptured from overheating through shortness of water.

_No. 26. Halifax. July 14th. 3 injured._

Locomotive, 10ft. 9in. long, 4ft. diameter, 1/2 inch plates, 130

lbs. pressure. Nearly all the barrel was blown away. The inside was

very much corroded, and there was a deep furrow at the line of first

rupture, caused by the alteration in form of the boiler in the strain

of working. This is usually obviated by substituting butt for lap

joints, so that the pressure does not tend to alter the circular shape

of barrel.

_No. 27. Limerick. July 21st. 2 killed, 1 injured._

Locomotive. Few particulars are obtained. The connecting rod broke, and

the loose end attached to the crank pierced the boiler, and allowed the

contents to issue and scald those near.

_No. 28. Hanley. (Fig. 15.) July 31st. 1 killed._

[Illustration: _Fig. 15._]

One of three. Plain Cylinder, 36ft. 9in. long, 5ft. diameter, 3/8 inch

plates, 50 lbs. pressure. The boiler parted at a seam over the fire

bridge. The front end was thrown upwards and to a considerable distance

to the front. The back part of the boiler was forced backwards. The

first rent took place at a seam-rip at the ruptured seam, and the

boiler exploded while the fire was being drawn in order to repair the

faulty place.

_No. 29. Easter Ross. August 8th. 2 killed, 3 injured._

Agricultural. It exploded while travelling, by its own steam power. The

engine had stuck fast, and extra pressure of steam was raised to try

and extricate it. The boiler was torn in pieces, and scattered to a

great distance.

_No. 30. Bilston. (Fig. 16.) August 17th. 1 killed._

[Illustration: _Fig. 16._]

One of two. Plain Cylinder, 30ft. long, 5ft. diameter, 3/8 inch plates,

46 lbs. pressure. The boiler gave way on the side where the plates were

overheated by the water being too low, and the front part of the shell

was flattened out and thrown some distance to the rear, as its course

was influenced by its remaining attached to the rest of the boiler as

by a hinge; while the front end was rent into several pieces, and the

back end was thrown also to the rear and rolled down a declivity into a

stream.

_No. 31. Liverpool. (Fig. 17.) August 20th. 7 killed, 5 injured._

[Illustration: _Fig. 17._]

Two Furnace Chimney Boiler, 42ft. 4in. high, 6ft. 9in. diameter,

1/2 inch plates, 50 lbs. pressure. Nearly half the bottom plate was

blown out, and the issuing contents found their way into the furnace

and increased the damage. The line of rupture near where it joined

the shell was corroded almost to a knife edge, which so reduced its

strength as to make it unable to bear the usual working pressure of

steam, in addition to that of the column of water in the boiler.

_No. 32. Accrington. August 31st. 1 killed._

A Kier or Steam Bleaching Chamber, somewhat like No. 2, and not used

for generating steam, 9ft. high, 8ft. diameter, 1/2 inch plates, 50

lbs. pressure. The bottom blew out, and the shell was torn to pieces.

The cause of explosion was weakness of the ruptured end, and want of

care in working.

_No. 33. Birmingham. September 11th. 1 killed, 1 injured._

Two tube Cornish. The manlid was wrongly fixed outside with internal

clamps. It was being screwed up tighter to stop leaking when the bolt

broke, and the lid came off and allowed the contents of the boiler to

escape.

_No. 34. Greatbridge. (Fig. 18.) September 21st. none injured._

[Illustration: _Fig. 18._]

One of four. One tube, externally fired, 18ft. 6in. long, 6ft. 6in.

diameter. Tube 3ft. diameter, 1/2 inch plates, 40 lbs. pressure. In

sketch the shell is shown in dotted lines to allow the tube to be

seen. The tube collapsed from end to end and ruptured at two seams,

and the contents issued so violently as to knock down the brickwork

and displace the boiler. The tube was in a very weak and corroded

condition, and unable to bear the usual working pressure.

_No. 35. Moxley. (Fig. 19.) September 28th. 13 killed, 2 injured._

[Illustration: _Fig. 19._]

One of four. Four Furnace Upright, 22ft. high, 10ft. 6in. diameter,

7/16 inch plates, 40 lbs. pressure. The boiler was rent into nine

pieces, one of which was not found. The dotted line in sketch shows the

outline of the boiler before explosion, and the fragments are arranged

as nearly as possible in their original position. The first rent was at

a seam-rip opposite the largest furnace, from whence the rupture opened

in every direction. This seam-rip must have existed some time before

explosion, and must have extended from rivet to rivet, until the boiler

was so much weakened as to be unable to bear the usual pressure.

_No. 36. Winsford. September 30th. 1 killed._

Plain Cylinder. Few particulars obtained. The end over the fire burst

open and allowed the contents to escape. A thick accumulation of scale

on the bottom had caused the plate to become overheated by preventing

proper contact of the water.

_No. 37. Elsecar. (Fig. 20.) October 2nd. 2 killed._

[Illustration: _Fig. 20._]

One of four. Two Furnace Upright, 21ft. high, 7ft. diameter, 7/16 inch

plates, 58 lbs. pressure. A large piece of plate was blown out of the

side of the boiler, and the reaction of the issuing contents threw

the boiler over on to its side. The plate was said to be overheated

from shortness of water, but as the centre tubes were uninjured,

the ruptured plate may have become overheated from the intense heat

impinging on one place, causing so rapid a generation of steam as to

prevent proper contact of water.

_No. 38. Glasgow. October 12th. 1 killed, 1 injured._

Plain Cylinder, 39ft. long, 5ft. diameter, 3/8 inch plates. A small

piece of plate about one-and-half-feet area blew out of the bottom,

and the contents issued so violently as to do much damage, although

the boiler itself was not otherwise injured. The ruptured plate was

corroded, to 1/16 inch thickness by the leaking of seams, caused by the

feed water entering close to the bottom of the boiler.

_No. 39. Swansea. October 13th. 2 killed, 1 injured._

One of twenty-four. One tube Cornish, worked by two furnaces, 23ft.

long, 6ft. 6in. diameter. Tube 3ft. 9in. diameter, 1/2 inch plates, 40

lbs. pressure. The tube was divided by a wall down the middle. The tube

collapsed sideways. It was said that one side was overheated through

shortness of water, but it is more than probable the explosion was

owing to the weakness of so large a tube without strengthening rings.

_No. 40. Preston. October 16th. 2 injured._

This was an arrangement of pipes, called an "Economiser," placed in the

flues of a set of boilers for heating the feed water. It was shattered

into fragments, causing considerable damage. As the whole apparatus was

said to be in proper order, the explosion had been attributed to coal

gas in the flues, and some peculiarities in the ruptured pipes bear out

the supposition.

_No. 41. London. (Fig. 21.) October 19th. 6 injured._

[Illustration: _Fig. 21._]

Kitchen Boiler, for supplying hot water to the top of a lofty house.

It was rectangular, 3ft. 6in. wide, 2ft. 6in. high, and 1ft. deep. The

front was blown out and caused considerable damage. The boiler was of

most weak shape, and although no pressure of steam was intended, it

appeared to have been overlooked that the column of water to the top of

the house would give sufficient pressure to make such a boiler unsafe.

_No. 42. London. (Fig. 22.) October 30th. 2 killed, 10 injured._

[Illustration: _Fig. 22._]

One tube Cornish, 15ft. long, 5ft. diameter, 3/8 inch plates, 50 lbs.

pressure. Tube oval at fire end, 2ft. 11in. wide, 2ft. 6in. high.

Circular beyond bridge, tapering to 2ft. diameter at back end. In

sketch outside shell is shown in dotted lines to allow tube to be seen.

The front of the tube burst beneath the fire bars, and rent upwards.

Tube collapsed beyond bridge and rent open at each side, but remained

intact over the fire. The oval part of the tube was of so very weak a

shape, that it burst open, and the collapse of the back part followed

as a consequence.

_No. 43. Birmingham. (Fig. 23.) December 2nd. 1 injured._

[Illustration: _Fig. 23._]

Small Portable Boiler, 4ft. 9in. high, 2ft. 3in. diameter, 1/4 inch

plates, 40 lbs. pressure. The shell was rent completely off. The

explosion arose from the large size of the manhole, which had no guard

ring on the edge, and the lid had strained it and caused several

cracks, and at last forced itself through the boiler, and the rents

spread in every direction, and caused the break up of the boiler.

_No. 44. Newcastle. (Fig. 24.) December 11th. 3 killed, 3 injured._

[Illustration: _Fig. 24._]

Marine Upright, 13ft. 3in. high, 6ft. 6in. diameter, 1/2 inch plates.

Internal fire-box 8ft. 6in. high, 6ft. diameter at bottom, 5ft. 3in.

diameter at the top, 3/8 inch plates, 50 lbs. pressure. In the sketch

the shell is shown in dotted lines to allow the internal fire-box to

be seen. The boiler was rent into many pieces, many of which were lost

in a river, so that a satisfactory conclusion as to the cause of the

explosion was impossible. The boiler was not very firmly stayed, and it

is supposed that it was weakened by corrosion round the fire doors.

_No. 45. Hartlepool. December 29th. 1 injured._

Marine, with 3 internal fireplaces joined at the back. The back of the

junction tube gave way at a place deeply corroded, and allowed the

contents of the boiler to escape.

* * * * *

NOTE.--Two more illustrations may be given which are not sufficiently

important to include in the above list.

* * * * *

_Willenhall. (Fig. 25.) December 24th. none injured._

[Illustration: _Fig. 25._]

One of two. Plain Cylinder, 25ft. 6in. long, 5ft. 6in. diameter, 3/8

inch plates, 30 lbs. pressure. The water was allowed to get low, and

the overheated plates opened and allowed the steam to escape harmlessly.

_Stoke. (Fig. 26.) December 9th. none injured._

[Illustration: _Fig. 26._]

One of eight. Four Furnace Upright, 22ft. high, 9ft. diameter, 7/16

inch plates, 45 lbs. pressure. The water was allowed to get so low

that the shell was overheated and rent, and the side tube slightly

collapsed, and the injury was not discovered until the feed water had

risen up to the rupture, when it ran into the furnaces without causing

any violent explosion, although cold water had been put into a red hot

boiler.

* * * * *

STOURBRIDGE:

PRINTED BY R. BROOMHALL, HIGH STREET.

BOILER EXPLOSIONS IN 1869.

_No. 1. Chesterfield. (Fig. 1.) January 14th. 4 killed, 2 injured._

[Illustration: _Fig. 1._]

One of two. One tube Cornish, 26ft. 6in. long, 6ft. diameter, tube

3ft. 3in. diameter, 3/8 inch plates, 45 lbs. pressure. The gauge glass

was broken and the float was either out of order or unobserved, as the

water was allowed to get 9 inches below the usual level, so that the

crown of the furnace became overheated and collapsed, and rent open

where a patch had been put on some little time before.

_No. 2. Manchester. (Fig. 2.) January 22nd. none injured._

[Illustration: _Fig. 2._]

Locomotive. The barrel was 10ft. 6in. long, 4ft. diameter, 7/16 inch

plates, 130 lbs. pressure. The engine was 14 years old, and had lately

been tested to 180 lbs. hydraulic pressure. The seams near the bottom

were so deeply "furrowed" or corroded just above the lap joint in a

continuous line that they rent open.

_No. 3. Greatbridge. (Fig. 3.) January 26th. 1 killed, 1 injured._

[Illustration: _Fig. 3._]

One of two. Plain Cylinder, with flat ends, 22ft. long, 4ft. 3in.

diameter, 3/8 inch plates, 60 lbs. pressure. There had formerly been

a tube with internal furnace, and this had been removed without

sufficient stays to compensate for the loss of strength. The plates

were arranged in the weakest way with seams in one line from end to

end, and the strength of the boiler had been further reduced by very

frequent patching. Fracture commenced about the centre of the long seam

under the dome, which had gradually ripped from rivet to rivet, until

unable to bear the ordinary pressure. The boiler exploded because it

was completely worn out, and shows how treacherous and uncertain a

boiler becomes by constant patching and alteration. See also No. 45.

_No. 4. Rotherham. (Fig. 4.) January 27th. 1 injured._

One of five. Plain cylinder, with dished ends, 36ft. long, 4ft. 6in.

diameter, 3/8 inch plates, 55 lbs. pressure. It had worked about 8

years, and was much patched over the fire end, and had lately been put

into what was supposed to be thorough repair. As there was no need of

an inquest the wreck was quickly cleared and some of the fragments

cut up, but enough particulars were obtained to give some idea of the

nature of the explosion.

[Illustration: _Fig. 4._]

The first rent must have taken place in the bottom seams over the fire,

where weakened by frequent repair.

_No. 5. Durham. (Fig. 5.) February 2nd. 1 killed, 4 injured._

[Illustration: _Fig. 5._]

One of twelve. Plain cylinder, 13 years old, 30ft. long, 6ft. diameter,

3/8 inch plates, 35 lbs. pressure. The plates were arranged lengthways,

so that the seams were in continuous lines from end to end. This has

often been mentioned as giving far less strength than where the plates

are placed in rings. There had been considerable repair at various

times, and just previous to explosion the boiler had been placed as

was supposed in thorough repair, and some new plates had been put

over the fireplace. The first rent appears to have taken place where

one of these plates joined the old work. The rent quickly extended

along a straight seam, and the boiler was blown into three pieces.

The explosion was simply caused by the boiler having been weakened by

frequent repair until unable to bear the ordinary working pressure.

Externally fired boilers, when so frequently patched become treacherous

and uncertain, and more especially so when the seams run from end to

end. See No. 59.

_No. 6. South Wales. February 12th. 2 injured._

This was a colliery boiler. Very few particulars were obtained. The

roof of the engine house was blown off, the boiler was torn from its

fittings and turned right round, and knocked down three walls and fell

in an upright position.

_No. 7. Cornwall. (Fig. 6.) February 15th. none injured._

[Illustration: _Fig. 6._]

One of four. One tube Cornish, 37ft. 6in. long, 7ft. diameter. Tube

4ft. 4in. diameter, 7/16 inch plates, 40 lbs. pressure.

The tube collapsed for the whole length beyond the bridge, and the back

end of boiler was blown out. The portion of tube over the fire was left

intact, and the fusible plug was uninjured. The cause of the explosion

was the weakness of the tube of such large diameter and so great

length. See No. 57.

_No. 8. Yarmouth. (Fig. 7.) February 23rd. 3 injured._

[Illustration: _Fig. 7._]

Marine, 17ft. long, and 15ft. high, 3/8 inch plates, 15 lbs. pressure.

The top was blown off, the plates having been extensively corroded.

The boiler had also been much weakened by altering it from a round to a

flat top without sufficient stays.

_No. 9. Drogheda. March 3rd. 2 injured._

The roof of a shed was blown off, but no particulars have been obtained.

_No. 10. West Bromwich. (Fig. 8.) March 9th. 3 injured._

[Illustration: _Fig. 8._]

One of two. Plain cylinder, 25ft. long, 4ft. 6in. diameter, 3/8 inch

plates, 42 lbs. pressure. The boiler had been very frequently repaired,

and a seam gave way where a large patch had just previously been put

on over the fire, in doing which the rivet holes of the old work had

evidently been cracked, rendering the boiler unable to bear the usual

working pressure. See No. 45.

_No. 11. Cornwall. March 18th. none injured._

One tube Cornish. The tube collapsed from want of water.

_No. 12. Broseley. (Fig. 9.) April 1st. 1 killed, 4 injured._

[Illustration: _Fig. 9._]

Multitubular, 9 years old, 8ft. 6in. long, barrel 6ft. long, and 2ft.

4in. diameter, 5/16 inch plates, 50 lbs. pressure. The cylinder was

attached to right side of the top of the boiler over the fire box, and

on the other side there was a very large manhole, the edges of which

were corroded, and so strained and cracked by the screwing up of the

manlid, as to be unable to bear the working pressure. The rent started

in all directions from the manhole allowing the boiler to split up into

three pieces. See Nos. 18 and 36.

_No. 13. Cornwall. April 11th. none injured._

One tube Cornish--but no particulars.

_No. 14. Barking. (Fig. 10.) April 19th. 4 killed, 2 injured._

[Illustration: _Fig. 10._]

Portable Crane, 8 years old, 8ft. 3in. high, 4ft. 4in. diameter, with

internal fire box, 6ft. high and 3ft. 6in. diameter, and chimney

passing out at the top, 5/16 inch plates, 40 lbs. pressure. The

internal fire box crushed in sideways, and the shell was rent into

several pieces. The attachment of the fire box to the shell was made

by bending the plates, as shown in enlarged sketch, and this is not so

rigid as double angle iron and had evidently strained the chimney tube.

This weakness had been so increased by deep corrosion just at the bend

of the plates that it had given way. The havoc and loss of life was far

greater than would have been supposed possible from so small a boiler,

but similar cases are mentioned in No. 43, 1868, and No. 57, 1866.

_No. 15. Durham. (Fig. 11.) April 23rd. none injured._

[Illustration: _Fig. 11._]

One of two. Plain cylinder, with plates arranged lengthways, 30ft.

long, 6ft. diameter, 3/8 inch plates, 9 lbs. pressure. A seam gave

way on the right side over the fire and immediately rent along the

straight seam from end to end, and the boiler was thrown in one mass a

great distance to the left. The boiler was very old and much weakened

by frequent repair, and at the time of explosion was being imprudently

worked at twice its usual pressure for a temporary purpose. See No. 59.

_No. 16. Bury. (Fig. 12.) April 29th. none injured._

[Illustration: _Fig. 12._]

Double Furnace, internally fired, 28ft. long, 7ft. diameter, 7/16 inch

plates, 55 lbs. pressure. Furnace tubes 7ft. long, 3ft. diameter, 3/8

inch plates. The crown of the left hand furnace collapsed and the right

hand furnace was slightly altered in shape, as if from overheating

by shortness of water, although the true cause was supposed to be

the thickening of the water by use of anti-incrustation composition,

preventing proper contact of the water with the plates.

_No. 17. Liverpool. (Fig. 13.) May 12th. 1 killed, 1 injured._

[Illustration: _Fig. 13._]

Plain cylinder, 10ft. long, 3ft. diameter, 3/8 inch plates, 50 lbs.

pressure. The ends were flat made of plates, with turned edges, and

there was such extensive corrosion on the inside of the bend that the

back end came out and was blown 30 yards to the right and rear, the

rest of the boiler being thrown to the front. The front plate had been

repaired with angle iron where similarly corroded, and the shell was

also much patched. The fractured edges were not 1/16 inch thick, so

that the boiler was not fit to carry any pressure with safety.

_No. 18. Abingdon. (Fig. 14.) May 13th. 2 killed, 2 injured._

[Illustration: _Fig. 14._]

Revolving Rag boiler, 16ft. long, 6ft. diameter, 7/16 in. plates. There

was no fire applied to the boiler itself, but it received steam through

one end from other ordinary boilers at 50 lbs. pressure. There were two

large rectangular manholes for putting in and taking out the rags, with

cast iron frames and lids, attached by bolts with large nuts or clamps.

The explosion appeared to have taken place when, in revolving, the

manlids were approaching the bottom, and the first part to give way was

at one of the manholes where the frame was previously broken. The cause

of the explosion was the weakness of the manholes, which were very

large, and both in the same line, and the attachment of the lids was

insecure, as the bolts did not go through the lids, or in any way help

to compensate for the large portion of the plate cut away. The boiler

was only supported at each end, and had to act as a hollow girder to

bear not only its own weight but the repeated shocks of the heavy

material inside falling over and over in addition to the pressure. See

Nos. 41 and 63, 1866.

_No. 19. Glasgow. May 19th. 1 killed, 1 injured._

Two tube Cornish. One of the tubes collapsed for a length of 8 feet

having become overheated through shortness of water.

_No. 20. Durham. (Fig. 15.) May 29th. 3 injured._

[Illustration: _Fig. 15._]

One of ten, 16 years old, Plain Cylinder with plates arranged

lengthways, 34ft. long, 5ft. 6in. diameter, 7/16 inch plates, 50 lbs.

pressure. The boiler gave way at one of the long straight seams near

the bottom, and rent into five pieces, which were scattered to wide

distances, but are so drawn in sketch as to show whereabouts in the

boiler they came from. The boiler had been weakened by frequent repair

until unable to bear the ordinary pressure. See No. 59.

_No. 21. South Wales. (Fig. 16.) May 31st. 5 killed, 4 injured._

[Illustration: _Fig. 16._]

Records of Steam Boiler Explosions · 第 8 / 12 段