AUXILIARY SYSTEMS

_Sampling System._ This system provides a means for removing liquid

samples from the primary loop to determine the effectiveness of the

purification system. Samples will be taken from both the inlet and

outlet flow of the primary demineralizers.

_Intermediate Cooling System._ The primary function is to provide clean

cooling water to the various reactor system components. A secondary

function is to maintain water in the annular primary shield tank.

The system consists of two separate flow circuits: a sea water circuit

and a fresh water circuit. Each of these circuits contains two pumps and

two coolers, plus other necessary components. The pumps and coolers are

arranged in parallel, permitting either pump to supply water to either

cooler.

In the sea water circuit, inlet temperature is 85° F and outlet

temperature is 106° F. The fresh water enters its coolers at 143° F and

leaves at 95° F.

Components outside and inside of the containment vessel are cooled by

one or the other of these intermediate cooling circuits.