LOSS OF POWER TO SAFETY CIRCUITS

The hydraulic drives that operate the “scram” mechanism require reserve

pressure to keep them in the “ready” position for “scram” condition and

are an integral part of the safety circuitry. A power failure in the

safety circuits would automatically put the hydraulic drives into

operation to “scram” the reactor.