292 STANDARD ELECTRICAL DICTIONARY.

To measure the forces acting a sonometer or audiometer is used. This is

shown in the upper part of the cut. Two fixed coils, c and e are mounted

at the ends of a graduated bar. A movable coil d is connected in the

telephone circuit; c and e by a switch can be connected with the battery

and microphone circuit, leaving out the induction balance coils. The

ends of the coils c and e, facing each other are of the same polarity.

If these coils, c and e, were equal in all respects, no sound would be

produced when d was midway between them. But they are so wound that the

zero position for d is very near one of them, c.

Assume that a balance has been obtained in the induction balance with

the coil d at zero. No sound is heard whether the switch is moved to

throw the current into one or the other circuit. A piece of metal placed

in one of the balance coils will cause the production of a sound. The

current is turned into the sonometer and d is moved until the same

sound, as tested by rapid movements of the switch, is heard in both

circuits. The displacement of d gives the value of the sound.

A milligram of copper is enough to produce a loud sound. Two coins can

be balanced against each other, and by rubbing one of them, or by

breathing on one of them, the balance will be disturbed and a sound will

be produced.

Prof. Hughes has also dispensed with the audiometer. He has used a strip

of zinc tapering from a width of 4 mm. (.16 inch) at one end to a sharp

edge or point at the other. The piece to be tested being in place in one

coil, the strip is moved across the face of the other until a balance is

obtained.

As possible uses the detection of counterfeit coins, the testing of

metals for similarity of composition and the location of bullets in the

body have been suggested. Care has to be taken that no masses of metal

interfere. Thus in tests of the person of a wounded man, the presence of

an iron truss, or of metallic bed springs may invalidate all

conclusions.

The same principle is carried out in an apparatus in which the parts are

arranged like the members of a Wheatstone bridge. One pair of coils is

used, which react on each other as primary and secondary coils. One of

the coils is in series with a telephone in the member of the bridge

corresponding to that containing the galvanometer of the Wheatstone

bridge. The latter is more properly termed an induction bridge.

Synonyms--Inductance Bridge--Inductance Balance--Induction Bridge.

The Standard Electrical Dictionary A Popular Dictionary of Words and Terms Used in the Practice of Electrical Engineering · 第 322 / 638 题