CHAPTER IX.

THE BEST MATERIAL FOR CONDUCTORS.

‘The art of protection against lightning,’ says a recent German

writer, in a book on conductors, ‘is precisely the same now as it was

a hundred years ago: still, it has made immense progress since that

time.’ Though apparently involving a paradox, the words nevertheless

are literally true. The art, or rather science, of guarding objects

against the destructive effects of lightning is theoretically the same

as it was in the days of Benjamin Franklin; nevertheless, the practical

execution of the appliances necessary to attain this aim has undergone

extraordinary improvements since that time. This has been due simply to

the astounding progress of the metallurgical arts for the last forty or

fifty years. With the help of machinery on a colossal scale, such as

was never dreamt of before, our factories have come to produce metallic

masses of dimensions and shapes such as make all former achievements of

the kind appear utterly insignificant. We build huge iron ships, armed

with cannon of ponderous weight; we throw iron bridges across rivers

and arms of the sea; we lay metallic cables through the ocean and over

the earth, encircling the globe. All these wonderful achievements, in

which the development of engineering science went hand in hand with

that of tool-making and the ever-growing employment of the power of

steam, have gone to the constant improvement of lightning conductors.

They have benefited, indirectly, in the result of great inventions, and

of immense toil and labour, originally directed to other ends.

There is something half touching, half comical, in reading of the

troubles which Benjamin Franklin had to undergo before he was able to

set up his first lightning conductor. He could meet with no assistance

but that of the blacksmith of little Philadelphia; and the ability

of the latter in the art of forging iron rods more than a few feet

in length was of the most limited kind. The ingenuity of Franklin

overcame this difficulty by a variety of clever contrivances, such

as connecting a number of small rods by caps and joints, fitting

closely; but others were not so successful as he in the matter. Even

in Paris there were no artisans to be found, for many years after

lightning conductors were first recommended, able to make them, and

foreigners, chiefly English, had to be brought there for the purpose.

The difficulties arising from this backward state of the industrial

arts were greatly increased by the belief, prevalent for a long time,

that lightning conductors, to be efficient, ought to be of very great

height, their so-called ‘area of protection’ being in proportion to

their height. The supposition, originating in France, was carried to

extremes in that country, chiefly through the teachings of M. J. B.

Le Roy, a very able but eccentric man. Guided by vague analogies in

electrical phenomena, M. Le Roy, who enjoyed in his time--the latter

part of the eighteenth century--the reputation of being an authority on

the subject of lightning conductors, laid it down as an indisputable

fact that the ‘Franklin rods’ only protected buildings if rising high

above them. He recommended the length of the rods above the chimney, or

summit of any edifice, to be not less than fifteen feet, guaranteeing

that, if of this height, they would offer absolute protection against

lightning over an area of four times the same diameter--that is, sixty

feet. Modern experience has proved this to be an absurdity; still,

in the infancy of all knowledge about lightning conductors it was,

perhaps, not unnatural that even learned men should believe in such

fancies. Lightning was looked upon, not only in name but in reality,

as an electric ‘fluid’ and the conductor was supposed to draw this

‘fluid’ from the clouds. Therefore it was but cogent reasoning to raise

conductors as high above the roofs, and as near to the storm-clouds, as

could possibly be done. If possessed of modern means for manufacturing

pieces of metal of almost any length, M. Le Roy would not improbably

have recommended to elevate lightning conductors a couple of hundred

feet, instead of only fifteen, above the summit of buildings.

It was owing chiefly to the difficulty of forging long iron pieces,

and of welding them together in a satisfactory manner, that, for many

years after lightning conductors had been introduced into Europe,

there were constant attempts made to find substitutes for the rods

devised by Franklin. Chains were largely used towards the end of the

last and the beginning of the present century, both in France and

Germany, their employment having been suggested by the example of the

English navy, where they were introduced, as already mentioned, upon

the recommendation of Dr. Watson. The Continental mode of using iron

chains for the protection of buildings against lightning was to hang

them between the upper part of the conductor, surmounting the roof,

which continued to be a straight piece of metal or rod, and the lower

portion buried in the ground, sometimes, but not always, likewise a

chain, but thicker than the rest. The characteristic of this method,

and showing its long existence, is that it gave rise to a nomenclature

existing to this day in France and Germany, where in all books on

lightning conductors they are described as consisting of three distinct

parts. The French call the upper part of the rod, over the roof, ‘_la

tige_,’ the stem or stalk; and the Germans, ‘_die Auffangstange_’

literally the reception-rod. In both languages the middle part,

from the roof downwards to the earth’s surface, is described as the

conductor proper, ‘_le conducteur_’ and ‘_der Leiter_.’ Again, the

lowest underground part of the conductor is designated, by the French,

‘_la racine_,’ the root, and by the Germans as ‘_der Bodenleiter_,’

or the ground-conductor. It has often been said that, as language

springs from ideas, so it reacts upon them, and if the proposition

be true, as most will admit, the French and German designations of

the parts of lightning conductors--also to be found in Italian, and

adopted in a few of the older English treatises on the subject, mostly

translations--have a strongly misleading tendency. Nothing could be

further from the truth than the assertion that a conductor ought to

consist of three distinct parts. On the contrary, the more it is ‘one

and undivided,’ the better it will be as a lightning protector.

The use of iron chains as conductors gave rise to very many fatal

accidents, and for a time resulted in an outcry that the system

itself could not be depended upon, as it was known to be not always

efficacious. Lists were published of numerous instances in which

buildings with what were supposed to be the best conductors were struck

by lightning, from which it was argued that Franklin’s great discovery

of the electric force always seeking a metallic path to the earth

was a myth. It was not till some painstaking scientific men, deeply

interested in the subject, had set to work to discover the causes

of the failure, that the whole became plain enough. The chains, in

some of the instances in which they had proved inefficient lightning

conductors, were found to be corroded to such an extent as barely to

hang together. Of course this corrosion would impair the efficiency

of the conductor by reducing the quantity of metal; but the chief

objection to the use of chains lies in the fact long ago pointed out

by Mr. Newall, that even supposing a chain were formed of links of

half-inch copper rods, and were perfectly bright and clean, the area

of the conductor is reduced to a mere point where the links touch each

other, and the resistance becomes so great in such a small conductor

that instances have been recorded of the fusion of the links. In other

cases, as in that of H.M.S. ‘Ætna’ in 1830, the chain was boomed out,

and did not touch the water!

Simultaneously with the chains, there was trial made, in several

Continental states, and also in England, of several other metallic

conductors besides iron. Tin and lead had both their advocates, but

the latter more than the former, on account of its far lower price. As

regards tin, it had really no advantages whatever over iron, except

pliability and non-oxidation. Against this was to be set that it was

much more expensive than iron, with only about the same conducting

power, according to Becquerel, Ohm, and other investigators. Professor

Lenz, it is true, ranked tin very much higher, asserting, from

experiments of his own, that its power of conductivity was nearly twice

that of iron; and it was partly owing to his great influence that

the metal obtained a trial in several countries, more particularly

in Russia and in the United States of America. Still, the result was

not satisfactory on many accounts, and its price alone brought tin

to be soon abandoned as a conductor. Lead had a far longer trial.

Its cheapness recommended it strongly, and equally so its extreme

pliability. One of the greatest difficulties of the constructors of

‘Franklin rods,’ when first they came into demand, was to make the

iron pieces fit properly around sharp corners of buildings, either

by bending them in fire, or, as was more commonly done, soldering

them together, or employing screws and other joints. But it was early

discovered that these junctions, when occurring at acute angles, were

bad conductors, occasioning sometimes the electric force to leave its

traced course, and fly off in some other direction. It is probable

that, in several well-authenticated instances in which this really did

happen, the joints were eaten away by oxidation, as in the case of

the chains; still, the effect of such occurrences was all the same.

The joining of strips of lead together was a far easier task than

that of handling iron in the same way, particularly for inexperienced

workmen, and thus the employment of the metal continued for some

time. However, it had to be abandoned gradually, on account of its

manifest disadvantages. Its extreme softness, which made it liable to

be broken by any accident, was one of them, and, still more so, its

want of conducting power--only about one-half that of iron. Thus leaden

conductors slowly went out of use, except in the form in which they

still act often to great advantage, that of water-pipes.

Among all the experiments made for producing the most perfect lightning

conductors, the one which created the greatest attention, some fifty

years ago, both on the Continent and in England, was the employment

of ropes made of brass wire. They were first recommended about the

year 1815 by a professor at the University of Munich, J. C. von Yelin,

distinguished for his researches into the nature of thunderstorms.

Through his influence most of the public edifices of Bavaria, more

particularly the churches, were provided with conductors of brass

ropes; and within a few years their employment became so popular,

owing to the ease with which they could be attached to all buildings,

that even the Roman Catholic clergy changed their attitude, and,

from being opposed to ‘heretical rods,’ advocated their extension in

every direction. But it was not long before the trust in brass ropes

as protectors against lightning was rudely shaken. Several instances

occurred in which buildings so protected were struck and damaged by

lightning, and at last there came a case which attracted the widest

attention, leading, on account of its supposed importance, to the

institution of a Royal Commission to report thereon. The little town

of Rosstall, in Franconia, Bavaria, had a church the steeple of which

was 156 feet high; and, standing on the brow of a hill, it overlooked

the country far and wide, visible for many miles. Necessarily much

exposed to the influence of lightning clouds, it had been provided

with one of the best brass-wire conductors, designed by Professor von

Yelin himself, and made of unusual thickness, being over an inch in

diameter. Nevertheless, on the evening of April 30, 1822, while a dark

storm-cloud, of extraordinary thickness, was passing over Rosstall, a

heavy flash of lightning was seen to fall vertically upon the church

steeple, followed by a terrible peal of thunder, which seemed to shake

the earth. When people looked up they beheld the church clock thrown

from its place, and part of a lower wall of the edifice thrown to the

ground. It was clear that the electric discharge from the atmosphere

had been one of unusual energy, but equally clear that the trusted

conductor had not done its work.

It was partly through scientific controversies about the relative

conducting value of metals, and partly through the action then

taken by several German Governments of providing all buildings with

lightning conductors, that the Rosstall case excited an extraordinary

interest at the time. The Royal Commission appointed by the King

of Bavaria, presided over by an eminent savant, Professor Kastner,

went to Rosstall to inspect the effects of the lightning discharge,

and Professor von Yelin did the same, as an independent, though not

disinterested witness. Their reports as to actual facts were the same.

The lightning, after striking the steeple of the church, had melted

the top of the ‘_Auffangstange_,’ or highest part of the conductor,

and further down had passed along the brass rope till coming to the

clock, only a few inches distance from it. Here the electric force had

evidently divided itself into several streams--the one exerting its

disastrous effects upon the clock and brickwork, and several metallic

objects underneath, and the other passing down the rope conductor,

but not without bending it, and, in one or two places, tearing it to

pieces. Such were the facts, visible to all eyes. But the conclusion

drawn therefrom differed widely. The members of the Royal Commission

made it public that the reason of the Rosstall lightning conductor not

having been efficient had simply arisen from its nature. Brass-wire

ropes, they declared, though perhaps useful against small discharges

of electricity, formed no reliable safeguards against powerful ones;

and they therefore strongly advised a return to the old-fashioned

iron rods. The conclusion was vehemently disputed by Professor von

Yelin. He admitted that it might be better, to provide for the proper

discharge of extraordinary masses of the electric force, to make his

brass ropes, when applied to high churches and other large edifices,

even thicker than they had been at Rosstall; but at the same time he

utterly denied that, even in this case, they had been the origin of the

disaster. He showed that the real cause of it was that the conductor

had not been laid deep enough into the ground, so as to touch moist

earth. The church stood upon sandy soil, on an eminence, and to touch

‘good earth’ the brass rope ought to have been sunk down to a depth of

at least fifty feet, whereas it did not reach one-third of that depth.

The professor was undoubtedly right, but his antagonists nevertheless

prevailed. A public prejudice, which no argument could overcome, set in

against brass-wire conductors, and they were pulled down from nearly

all buildings on which they had been laid, to be replaced by iron rods.

Some time had to elapse before real justice was done to metallic ropes

as lightning conductors.

With our present knowledge of electrical phenomena, and the practical

art of making conductors, it may safely be affirmed that the Munich

professor was right in recommending ropes, though not in approving

of brass as the best metal. In its very nature, brass, a compound,

can never be thoroughly reliable, because its conducting power varies

according to its composition. The facility with which it allows the

electric force to pass through it depends, in fact, entirely on

the amount of copper which brass contains, and is greater or less

accordingly, since the other metal entering into its composition,

zinc, has less than one-third the same conductivity. Now brass is, for

various purposes, made sometimes of 70 parts of copper and 30 parts of

zinc, and again, only equal amounts of both metals, setting calculation

as to its conducting power entirely at nought. But besides this, brass

has the great fault of being excessively liable to destruction by

atmospheric influences, and it was found, among others, in Germany,

that while brass ropes were used as lightning conductors, they were

frequently destroyed, in a comparatively short space of time, by the

action of smoke alone. It is true, the Continental mode, existing

both in France and Germany, of spanning conductors over the tops of

chimneys--illustrated in the engraving here as a warning ‘how _not_ to

do it’--had much to answer for this atmospheric deterioration, since

even tougher metals than brass could not be expected to stand the

constant action of smoke, often containing sulphurous fumes. But even

without such an evidently absurd arrangement as that of running any

conductors, whether in the form of ropes or cords, across the orifices

of chimneys, brass could never have answered all the requirements of

a lightning conductor. It was with justice that brass-wire ropes were

nearly altogether discarded some thirty or forty years ago, after

having had a short-lived reputation.

[Illustration]

That copper should not have been employed, long before brass and other

metals, in serving mainly for lightning conductors, its pre-eminence

for this purpose being undisputed, would seem a strange fact, were

it not explicable on several grounds. The first was the cost of

the metal, which, though varying in price, is seldom less than six

or seven times that of iron. It was needless for the advocates of

copper as conductors--and there were not a few from the time its

high conductive power had been demonstrated--to say that if copper

was six times as dear as iron, it was likewise six times better as a

carrier of the electric force, and that consequently the price, in

respect of applicability for lightning protection, was in reality the

same. But the reply to this was that copper, being one of the most

expensive metals, except the so-called ‘precious’ ones, was exposed

to the temptation of theft, and ought therefore not to be employed,

since it was possible that vagrants, or other people, might tear off

at any time the, in more than one sense, valuable pieces of metal

protecting buildings against destruction from lightning. The argument,

perhaps, was not worth much, but a better one not mentioned was in the

background. It was, till quite recent times, an achievement of the

greatest difficulty to manufacture long rods or bands of sufficiently

pure copper to serve as lightning conductors. Sir William Snow Harris

attempted, as already related, to get over this impediment by taking

short plates, and fastening them together, and over each other, by

copper nails. But this process, besides being enormously expensive,

was in many other respects unsatisfactory, notably in that it made a

shifting of the plates possible, and by the destruction of a few of

them ruined the whole system. The pith and substance of the whole was

the technical difficulty of hammering or drawing pure copper out into

great lengths. That it must be pure was essential, the fact being

thoroughly established that the electric conductivity of copper,

mixed with impurities such as arsenic, is often not two-thirds, and

sometimes not as much as one-half, that of the pure metal. This was

conclusively shown by Sir William Thomson in a series of researches,

and likewise by that distinguished investigator in the conductivity of

metals, Professor Matthiessen. The latter, while placing copper on the

same rank with silver, and far above gold--100 to 78--furnished the

following instructive list as to the relative value of different kinds

of copper:—

Pure copper 100·00

Best American copper 92·57

Australian copper 88·86

Russian copper 59·34

Spanish ‘Rio Tinto’ copper 14·24

It will be seen that, according to the investigations of Professor

Matthiessen, admitted on all hands to be correct, the copper lowest

in the list, the ‘Rio Tinto,’ is barely equal to iron in electrical

conductivity, and, not having the hardness of the latter metal, would

be in every way inferior to it as a lightning protector. The employment

of the purest copper therefore became an essential point in the

manufacture of lightning conductors.

Fortunately, the difficulty was solved, at an earlier period than might

have been expected, by the demand for submarine cables. These had to

be made of wires of the highest possible electrical conductivity, and

the matter being one of high financial and commercial importance,

manufacturers soon began to use the utmost care in selecting ores

containing the smallest amount of metallic impurities. We believe

the lightning conductors now manufactured at the extensive works of

Mr. R. S. Newall, F.R.S., established at Gateshead on Tyne about

forty years ago, have generally a conductivity of 93 per cent. of

pure copper. It was laid down by one of the most eminent scientific

men of the day, not long ago, that the three principal qualities of

a good lightning conductor ought to be a maximum of conductivity, of

durability, and of flexibility that could be obtained, and there is

nothing coming up to this standard so well as ropes of pure copper.