CHAPTER XXXII

ARMATURE TROUBLES

A large proportion of the mishaps and breakdowns which occur with dynamos

and motors arise from causes more strictly within the province of the man

in charge than in that of the designer. The armature, being a complex and

delicately built structure, is subject in operation to various detrimental

influences giving rise to faults.

Many of the faults which occur are avoided by operators better informed as

to the electric and magnetic conditions which obtain in the running of the

machine, especially the mechanical stresses on the copper inductors due

to the magnetic field and the necessity of preserving proper insulation.

The chief mishaps to which armatures are subject are as follows:

1. Short circuits;

a. In individual coils;

b. Between adjacent coils;

c. Through frame or core;

d. Between sections of armature;

e. Partial short circuits.

2. Grounds;

3. Breaks in armature circuit.

Short Circuit in Individual Coils.--This is a common fault, which makes

its presence known by a violent heating of the armature, flashing at the

commutator, flickering of the light on lighting circuits, and by a smell

of burning varnish or overheated insulation. When these indications are

present, the machine should be stopped at once, otherwise the armature is

liable to be burnt out. The fault is due either to metallic dust lodging

in the insulation between adjacent bars of the commutator, or to one or

more convolutions of the coils coming into contact with each other, either

through a metallic filing becoming embedded in the insulation or damage

to the insulation.

[Illustration: Fig. 700.--Method of locating short circuited armature

coil. Disconnect the external and field circuits from the armature, and

pass a large current--say from 20 to 100 amperes--from a battery (B) or

another dynamo through the whole armature by means of the brushes. Then,

having previously well cleaned the commutator, measure the difference of

potential between adjacent segments all round the commutator (C), by means

of a voltmeter or galvanometer (G), the terminals of which are connected

to adjacent segments, as shown. The short circuited coil or coils will

be located by the difference of potential between the corresponding

segments being little or nothing. It may be remarked, however, that this

is not always a decisive test. In some cases the short circuit may be

intermittent, or may disappear as soon as the armature ceases to rotate.

In such cases, the short circuit is caused by the wire coming into contact

through the action of the centrifugal forces developed by the rotation of

the armature.]

Ques. How is the faulty coil located?

Ans. When the machine is stopped, the faulty coil, if not burnt out, can

generally be located by the baked appearance of the varnish or insulation,

and by its excessive temperature over the rest of the coils, being

detected also by the baked appearance of the varnish or insulation.

Ques. What should be done if the machine do not build, and it be suspected

that the fault is due to short circuited armature coils?

Ans. The field magnets should be excited by the current from a storage

battery or another dynamo, and, having raised the brushes from contact

with the commutator, the armature should be run for a short time. In

stopping, the faulty coil or coils may be located by the heat generated

by the short circuit.

When the dynamo is started for the purpose of localizing a short

circuit, precautions should be taken, and the machine only run for a

few minutes at a time until the faulty coil is detected.

When the faulty coil has been located, the insulation between the

segments of the commutator to which its ends are connected should be

carefully examined for anything that may bridge across from segment

to segment, and scraped clean. If the commutator be apparently all

right, the fault probably lies in the winding. The insulation of the

winding should be carefully examined, and any metallic filings or

other particles discovered therein carefully removed, and a little

shellac varnish applied to the faulty part.

[Illustration: Fig. 701.--Test for break in armature lead. Clean the

brushes and commutator, and apply current from a few cells of battery

having a telephone receiver in circuit as shown in the figure. If the

machine have more than two brushes, connect the leads to two adjoining

brushes and raise the others. Now rotate the armature slowly by hand and

there will be a distinct click in the receiver as each segment passes

under the brushes until one brush bears on the segment at fault, when the

clicking will cease. In making this test, the brushes must not cover more

than a single segment.]

Ques. If the insulation on adjacent conductors has been abraded, how

should it be repaired?

Ans. A small boxwood or other hardwood wedge, coated with shellac varnish

should be driven in tightly between the wire; this will generally be

sufficient.

[Illustration: Fig. 702.--Bar to bar test for open circuit in coil or

short circuit in one coil or between segments. If, in testing as in fig.

701, on rotating the armature completely around, the receiver indicate no

break in the leads, connect the battery leads directly to the brushes, as

shown in the above figure, and touch the connections from the receiver

to two adjacent bars, working from bar to bar. The clicking should be

substantially the same between any two commutator bars; if the clicking

suddenly rise in tone between two bars, it indicates a high resistance in

the coil or a break (open circuit).]

Ques. If a faulty coil cannot be quickly repaired and the dynamo be

needed, what should be done?

Ans. The coil may be cut out of circuit, and the corresponding commutator

segments connected together with a piece of wire (of a size proportionate

to the amount of current to be carried), soldered to each. It will not be

necessary to cut out and remove the entire coil.

If the active portions only be separated so that they do not form a

closed circuit, it will answer the purpose. If the wires be cut with

a chisel at the point where they pass over the ends of the core, and

the ends separated, it will be quite as effective as removing the

entire coil. It is wise, of course, to rewind the coil at the first

opportunity.

[Illustration: Fig. 703.--Alternate bar test for short circuit between

sections. Where two adjacent commutator bars are in contact, or a

coil between two segments becomes short circuited, the bar to bar test

described in fig. 702 will detect the fault by the telephone receiver

remaining silent. If a short circuit be found, the leads from the receiver

should then include or straddle three commutator bars, as here shown. The

normal click will then be twice that between two segments until the faulty

coils are reached, when the clicking will be less. When this happens,

test each coil for trouble and, if individually they be all right, the

trouble is between the two. To test for a ground place one terminal of

the receiver on the shaft or frame of the machine, and the other on the

commutator. If there be a click it indicates a ground. Move the terminal

about the commutator until the least clicking is heard and at or near that

point will be found the contact. Grounds in field coils can be located in

the same manner.]

Short Circuits between Adjacent Coils.--In ring armatures the presence of

this fault does not necessarily imply that the machine will not build;

in drum armatures, wound into a single layer of conductors, it entirely

prevents this occurring.

Reference to a winding diagram will show that adjacent coils are during

a certain period of the revolution at the full difference of pressure

generated by the machine. Hence, if any two adjacent coils be connected

together or short circuited, the whole of the armature will be practically

closed on itself, any current generated flowing within the armature only.

Large drum armatures wound with compressed and stranded bars and

connectors are particularly susceptible to this fault, a slight blow

generally forcing one or more of the strands into contact with the

adjacent bars, thus short circuiting the armature, and rendering it

practically useless so far as the generation of current is concerned.

In this class of short circuit in drum armatures, the method of locating

the faulty coils by exciting the field, and running the armatures on open

circuit, does not apply, for the reason that the whole armature will be

heated equally.

A method of locating such fault is illustrated in fig. 704. This

applies to drum wound armatures. Faults of this description can

frequently be discovered by a careful inspection of the windings of

the armature without recourse to testing. When located, the fault

can usually be repaired with a hardwood wedge, as explained above,

or a piece of mica or vulcanized fibre cemented in place with shellac

varnish.

[Illustration: Fig. 704.--Method of locating short circuits between

adjacent armature coils. Fasten a monkey wrench to the rim of the pulley,

or a crank to the shaft. Now, excite the fields, and, to make the effects

more marked, connect the coils in parallel. When this has been done it

will require considerable force to rotate the armature, and then it will

move quite slowly, except at one position. When this position has been

found, mark the armature at points in the center of the pole pieces at

points A and B and at both ends of the armature. The explanation is that

both halves of the armature oppose one another at this position; but when

not at these points a continuous circuit is formed, and the resultant

magnetic effect is considerable. The "cross" or "short" circuit is nearly

always found on the commutator end in the last half of the winding, where

the wires pass down through the first half terminals. This applies to

an unequal winding. In armatures where the windings are equal, it is as

liable to occur at one point as at another. With this method a defect can

be found and remedied in a few moments, for it has always been a simple

matter to repair it when discovered. These results can be observed in a

perfect armature by connecting the opposite sections of the commutator.]

Short Circuits between Sections through Frame or Core of

Armature.--Detection of this fault can be effected by the methods

described above, and by disconnecting the whole of the armature coils

from the commutator and from each other, and testing each separately

with a battery and galvanometer coupled up as in fig. 705, one wire being

connected to the shaft and the other to the end of the coil under test.

As a rule, there is no way of remedying this fault other than unwinding

the defective coils, reinsulating the core, and rewinding new coils.

[Illustration: Fig. 705.--Method of locating short circuits between coils

through armature core. The galvanometer, battery and coil to be tested

are connected in series as shown, and then the unconnected terminal of the

galvanometer is brought into contact with the shaft. If then some portion

of the insulation of the wire has been abraded or destroyed, thus bringing

the bare wire into contact with the metal core, as at A in the figure,

the needle of the galvanometer will be deflected since a closed circuit is

formed through the core and wire. If the insulation be perfect, the needle

will not be deflected. It will thus be seen that in the conductivity test

(fig. 700) it is necessary that the needle should be deflected, or turned,

to prove that all is right, while in the insulation test the converse

holds good; if the needle be deflected, it proves that the insulation is

broken down.]

Short Circuits between Sections through Binding Wires.--This fault is

the result of a loose winding, and is caused by the insulation upon which

the binding wires are wound giving way, thus bringing coils at different

pressures together. As a consequence of the heavy current which flows,

the binding wires are as a rule unsoldered or burned. The location of the

fault can therefore be effected by simple inspection. To remedy, it will

be necessary to unwind and rewind on new binding wires, on bands of mica

or vulcanized fibre, soldering at intervals to obviate flying asunder.

Partial Short Circuits in Armatures.--This is usually due to the presence

of moisture in the windings. To remedy the fault, the armature should be

taken out and exposed to a moderate heat, or subjected to a current equal

to that ordinarily given by the dynamo. Under the action of heat or of

this current the moisture will be gradually dispersed. When thoroughly

dry, and while still warm, a coat of shellac should be applied to the

whole of the windings.

[Illustration: Fig. 706.--Method of testing for breaks. The instruments

are connected as shown. B is the battery, G the galvanometer, and S the

coil of wire being tested. One terminal of the battery is connected to a

terminal of the galvanometer, and the other to one of the ends of the coil

under test. The other terminal of the galvanometer is connected to the

other end of the coil. If the connecting wires be making good electrical

contact with the respective terminals, and the wire of coil being tested

be unbroken, the needle of the galvanometer will be deflected as soon

as a closed circuit is made by the end of the coil coming into contact

with the galvanometer terminal. If the wire of the coil be broken in some

part or the ends of the connecting wires do not make good electrical

contact with the terminals, the needle will not be deflected. In order

to prevent mistakes, it is advisable to test the battery and galvanometer

connections and contacts by short circuiting or bringing the ends of the

wire connecting the terminal of the galvanometer and negative pole or

the battery together before starting to test the circuit or coil. If the

needle be deflected, the connections are all right; if not deflected,

there is a bad contact somewhere, which must be made good before the test

can proceed.]

Burning of Armature Coils.--The reason for the burning of an armature

coil may be explained as follows: The coil, segments, and the short

circuit between the segments form a closed circuit of low resistance so

that it is only necessary to have a low pressure set up in the active

portion of the coil to force a very large current through the coil and

the short circuited commutator bars. The heating effect of this current

is sufficient to burn out the coil.

[Illustration: Fig. 707.--Watson field coils. Automatic machinery is

employed to wind these coils; after winding, they are bound with tape,

then baked to expel all moisture, and while hot, are saturated with

an insulating compound and again baked for twelve hours to make them

practically oil and water proof. Heavy flexible leads are brought out to

avoid danger of breaking or other damage.]

Cutting Out Damaged Armature Coils.--To cut out a damaged coil from

an armature, first, disconnect the coil from the commutator, and after

cutting off the leads, insulate the exposed parts with tape. Then connect

the commutator bars (which were connected with the leads) with a wire of

the same size as the wire winding.

To remove the coil entirely, cut the band wire or remove the wedges, and

lift up a sufficient number of leads and coils to permit of the removal

of the damaged coil.

Grounds in Armatures.--These faults occur when the armature coils become

connected to the frame or core of the armature. When this grounding is

confined to a single coil, it is not in itself liable to do damage. A

simple method of locating a grounded coil is illustrated in fig. 708.

[Illustration: Fig. 708.--Method of locating grounded armature coil. B

is a battery or dynamo circuit giving a current of a few amperes through

the armature by its own brushes (1 and 2). At G is placed a roughly

made galvanometer, to carry some 25 amperes or so, one terminal being

in connection with the shaft of the armature, and the other attached to

a movable brush 3. Since the function of the particular galvanometer is

simply to show a deflection when a current is passing, and to mark zero

when there is none, a coil of thick wire with a pocket compass in the

center will do all that is required, but care must be taken to remove

it sufficiently far away from the disturbing effects of the armature

magnetism. The manner of testing is as follows: Assume a steady current to

be flowing from battery B through the armature; touch the commutator with

brush 3, and a current will flow through G. Slowly rotate the armature

or the brush 3 until the galvanometer G shows no deflection. The coil

in contact with 3 will be found to be _grounded_. A hand regulator or

rheostat R may be inserted in series with the battery or dynamo circuit

to regulate the strength of the current passing.]

Ques. What is the advantage of this test?

Ans. The damaged coil can be located without unsoldering the coils from

the commutator, which is sometimes a difficult operation without proper

tools; further, the fault can frequently be repaired without disconnecting

any of the wires if its exact position be determined.

Magneto Test for Grounded Armatures.--A magneto test for grounded

armatures is not to be recommended, as armatures often possess sufficient

static capacity to cause a magneto to ring even though there be no leak.

This is due to the alternating current given by the magneto for when the

circuit has capacity it acts as a condenser and at each revolution of the

armature of the magneto a rush of current goes out and returns, charging

the surfaces of the conductor alternately in opposite directions, and

ringing the bell during the process.

[Illustration: Fig. 709.--Method of binding armature winding. Complete

appliances for handling armatures in making repairs are usually not

available with most street railway companies, since they are so seldom

required. When needed, therefore, some temporary contrivance must be

resorted to for help in the dilemma. Should an armature burn out, some

local concern that makes coils and rewinds armatures may be available to

do the work; again, it will be necessary to send to the manufacturers for

a man, as soon as coils can be made ready for the work. In no case should

any but an experienced man be given charge of this work. But if there be

any doubt as to whether the armature is really burnt out, let a competent

man be the judge. When a large armature needs repairing, a pair of chain

tongs can be used on some part of the shaft when putting in the coils,

and a block and tackle, as shown, can be used, when putting on the band

wires. Do not finish one band and then cut off the wire, but run it over

for the next, etc. Then solder and trim off the wires.]

Breaks in Armature Circuit.--A partial or complete break in the armature

circuit is always accompanied by heavy sparking at the commutator, but

not, as a rule, by an excessive heating of the armature or slipping of

the belt, and this enables the fault to be distinguished from a short

circuit. The faulty part can always be readily located by the "flat" which

it produces upon the surface of the commutator. The armature circuit being

open at the faulty part, heavy sparking results at every half revolution

as the brushes pass over it, and as a consequence the corresponding

segments become "pitted" or "flattened" with respect to the others; they

may easily be discovered on examination.

Breaks in the armature circuit may occur in either the commutator

or in the coils of the armature. To ascertain whether it be in the

latter, carefully examine the winding of the faulty coil.

The defect may be sought for more particularly at the commutator end

of the armature, as breaks in the wire are most frequent where the

connections are made with the commutator segments. If no break can

be discovered, try passing a heavy current through the faulty coil by

means of the brushes.

If a partial break exist with sufficient contact to pass a current,

the coil will be heated at that point and may be discovered by running

the fingers over the coil.

When located, the fault may be repaired by rewinding the coil, or

carefully cleaning the broken ends and jointing.

The fault may also be temporarily repaired by soldering the adjacent

commutator segments together without disconnecting the coil.

Hawkins Electrical Guide v. 03 (of 10) Questions, Answers, & Illustrations, A progressive course of study for engineers, electricians, students and those desiring to acquire a working knowledge of electricity and its applications · 第 7 / 10 章