This motor, which is the latest and most important development in the

electric railway field, is of the series commutator type, and does

not differ in principle from its direct-current contemporary. It is

called the _commutator type single-phase motor_, and is the one type of

alternating-current motor which has the same desirable characteristics

for railway work as the direct-current series motor.

[Illustration: Compensating Alternating-Current Railway Motor.]

At first thought it may seem strange that a motor built fundamentally

on the same lines as a direct-current machine would operate on an

alternating current, as it might appear that the motor would tend to

turn first in one direction and then in the opposite direction with no

resultant motion. This, however, is not the case, because the direction

of rotation of a motor depends upon the relative direction of its field

and armature currents. If now the field were maintained in a constant

direction and the armature supplied with alternating current, then the

tendency would be to rotate first in one direction and then in the

other, it is true, but as a matter of fact the alternating current

is supplied to the field in series with the armature, so that when

the direction of current in the armature changes it also reverses

in the field. The result is that the relative direction of current

in the field and armature is constant and the motor has, therefore,

a tendency to turn continuously in one direction as long as the

alternating-current power is supplied.

This being true, the question may arise as to why the single-phase

motor was not brought to the front for railway work long ago. The

answer is that there were certain inherent difficulties to be overcome,

and the development of the single-phase motor has been simply the

removal of these difficulties, rather than the design of an entirely

new type of machine.

The most serious obstacle to overcome is the sparking at the

commutator, due to the fact that when the terminals of a coil are

bridged by a brush, the coil acts like the short circuited secondary of

a transformer of which the field winding constitutes the primary. Also

there is an iron loss due to the alternating magnetic flux through the

magnetic circuit; while another objectionable feature is the counter

E.M.F. induced in the field coils.

[Illustration: Alternating-Current Railway Motor Field.]

In order that it may overcome these difficulties, to some extent, at

least, the single-phase motor presents certain modifications from the

direct-current type, in that it has more field poles, and the entire

magnetic circuit of field frame, cores, and pole pieces, is carefully

laminated. The number of commutator segments is also increased, thus

reducing the number of armature turns per coil, and there are special

features introduced to prevent sparking, such as compensating windings

which neutralize the effect of armature distortion; the use of narrow

brushes; a type of armature winding which gives a low reactance per

coil; the use of high resistance leads between the armature coils and

commutator segments, etc.

The single-phase motor is then a refined and highly perfected type of

direct-current motor, and this explains the fact that it will operate

on either alternating- or direct-current circuits. In fact some claim

that it will operate even more efficiently on direct current than the

regulation direct-current motor itself.

[Illustration: Single-Phase Armature, Unmounted.]

The field for which the single-phase motor seems particularly adapted

is that of heavy service and interurban work, where it has many

distinct advantages, among which may be mentioned the following:

The alternating current on the trolley allows the use of a high voltage

and correspondingly smaller current, which reduces the line loss and

permits of the use of smaller wire, which of course means a saving

in the investment for copper. Moreover, the difficulty of collecting

a large current from the trolley wire is overcome. Rotary converter

substations are eliminated, being replaced by simple and cheap

transformer substations, which require no attendance. The capacity

can be easily increased by merely increasing the number of these

transformer substations.

The efficiency of speed control is a point particularly worthy of

mention. In direct-current speed control, the series-parallel method

is used almost exclusively. This consists of putting the motors in

series for low speed and in parallel for high speed. This permits of

two, and only two, economical running points; the one at full speed,

and the other at approximately half speed. All intermediate points must

be obtained by the insertion of dead resistance in which the voltage

is simply wasted as heat, thus causing a large loss particularly at

starting.

With the single-phase motor the current is supplied to the car with a

voltage of say 3300. It is then stepped down by means of transformers

on the car to the voltage of the motors, which may be 200 or 250

volts. The speed is, of course, dependent upon the voltage applied to

the motors, and this voltage is cut down from the maximum, to obtain

various gradations, by means of an induction controller, or by taps

from an auto-transformer. Thus the motor takes from the trolley only

slightly more power than is actually required to operate it at any

given speed, instead of taking full voltage from the line and absorbing

part of it in dead resistance.

[Illustration: Auto Transformer.]

The effect of electrolysis upon neighboring water pipes paralleling

an electric road, which is the cause of so much trouble with direct

current, is entirely eliminated, as electrolysis evidently will not

take place with alternating current.

In connection with this system a sliding contact device or bow trolley

has in many cases been substituted with considerable success for the

ordinary current collecting device, or trolley wheel, one advantage

of this being that the car can be run in either direction without

reversing the contact device. Another very satisfactory form of trolley

is of the pantograph type with sliding shoe, shown on the New York, New

Haven and Hartford locomotive.

A new form of trolley suspension known as the catenary has been

developed to meet the demand for more substantial construction

necessitated by the high trolley voltage. This consists of a stranded

galvanized steel messenger or supporting cable, from which the trolley

wire is suspended at intervals of about 10 feet, thus keeping it at a

uniform distance above the track.

[Illustration: Master Controller Used in Connection with the

Multiple-Unit System as Applied to Single-Phase Work.]

The multiple-unit system of control can be used in connection with

single-phase motors, this being the scheme which has been in use for

a long time on elevated and other roads using direct current, whereby

several cars can be operated in a train from a single point, each car

being equipped with its individual motor and controlling apparatus.

The entire system is then controlled as one unit by a single motorman

stationed usually in the front of the first car. This method of control

has become of such tremendous importance that any system to which

it cannot be applied would be seriously handicapped. Cars equipped

with single-phase motors can be operated on either direct-current or

alternating-current lines, with high or low tension, with trolley or

third rail.

It must not be supposed, however, that with all the above mentioned

advantages, the single-phase system has no disadvantages, as such is

not the case. The car equipment, due to the transformers and the nature

of the motors, is considerably heavier. The motors themselves are more

expensive on account of their special construction. The equipment is

not always adapted for operation on existing lines. There is a slight

increased “apparent” resistance of the trolley line and a considerable

increased “apparent” resistance of the rails, due to reactance caused

by the alternating nature of the current. There is also an active

electro-motive force between the field coils, which is objectionable,

and there is a possibility of interference with neighboring telephone

lines. Furthermore, there is slight loss in power in the transformers

on the car, while the power-factor of the motors is less than unity.

Summing the matter up as a whole, however, the advantages seem to

overbalance the disadvantages, at least for many kinds of work, and it

is safe to predict that this new system of operation will have a very

wide and increasing application in the near future.

As to the operation of the system in general, the current may be

developed by single-phase, two-phase, or three-phase generators,

and supplied to the transformer substations just as it was formerly

supplied to the rotary converter substations. Only a single phase

is used on any section of the trolley line. The voltage on this

transmission line will depend upon the existing conditions, and can be

figured out like any other problem in power transmission.

[Illustration: Truck Complete with Single-Phase Motors and Contact

Shoes.]

Three-phase generators would ordinarily be used, as less copper is

required to supply a given amount of power. The common frequency is 25

cycles per second. At the transformer stations, the voltage is then

stepped down to that required on the trolley, which may be 2,000,

3,300, 6,600, or even 11,000 volts. While we cannot speak yet of a

standard voltage, 3300 seems to be finding considerable favor. The

voltage for which the motors are wound is 200 or 250, the General

Electric motors using the former voltage, and the Westinghouse the

latter. When operating on alternating current the motors are connected

in parallel, and when running on direct current they are connected

in series. Motors have been constructed from 50 to 225 horsepower,

and there is no apparent reason why larger ones could not be made to

operate with equal satisfaction.

[Illustration: Magnetic Speed Indicator.]

Among the roads in this country which are either using, or planning to

use single-phase current, may be mentioned the Ballston-Schenectady

line, which was one of the first systems to be equipped and has

been in successful operation for some time. This road uses the

alternating-current motor developed by the General Electric Co. The

motors are adapted for operation on the 2,000-volt alternating-current

trolley between cities, and on the standard 600-volt direct current

in Schenectady. They are wound for 400 volts, and are operated in

series on the 600-volt direct current. The frequency used is 25 cycles.

Current is supplied by an overhead trolley, no feeders being used.

A second road of importance is one in Georgia between Atlanta and

Marietta, which is 15 miles in length. This uses the Westinghouse

equipment. The current on the trolley is 2,200 volts and 25 cycles. It

is transmitted at a voltage of 22,000.

Another road of importance is the Indiana and Cincinnati interurban

line, 41 miles in length, which has been in operation on regular

schedule since July 1st, 1905. For 37 miles the road is operated

from alternating current, and for 4 miles, from direct current. Four

75-horse power motors per car are used, capable of a maximum speed of

65 miles per hour.

[Illustration: Armature Quill.]

The Bloomington, Pontiac and Joliet Electric Railway is a single-phase

road equipped with General Electric apparatus, and has maintained a

regular schedule over a distance of more than 10 miles since March,

1905.

The plans are now being laid for a single-phase road, which will run

south from Spokane, Washington, a distance of 150 miles. The current

on the transmission line is 45,000 volts, which is stepped down to

6,600 on the trolley. The car will be capable of operating on current

from a 6,600-volt alternating, a 700-volt alternating, or a 575-volt

direct-current supply.

Perhaps the most important move which has been made in the direction

of single-phase traction thus far is the decision of the New York, New

Haven, and Hartford road to establish a long-distance passenger traffic

on the single-phase system. According to the latest plans this road

will operate between the Grand Central Depot and Woodlawn, N. Y., over

the terminal tracks of the New York Central road, on direct current

taken from the trolley. From Woodlawn, N. Y., to Stamford, Conn., the

road will be operated on the single-phase system.

[Illustration: A Pair of Drivers with Single-Phase Motor Mounted upon

Quill.]

The equipment is being supplied by the Westinghouse Co. The current

is generated by revolving-field type turbine-driven alternators.

The armatures are designed for either three-phase or single-phase

connection. The current is generated at 25 cycles and 11,000 volts,

being delivered directly to the trolley, and thence to the cars,

without the intervention of any transformers. The double catenary

suspension from messenger wires is used to support the trolley. The

locomotives are each equipped with four 200-H. P. gearless motors,

designed to operate on 235-volt alternating current and 275- to

300-volt direct current. The armature is not mounted on the shaft

direct, but is built upon a quill through which the axle passes with

about ⅝-inch clearance all around. There is a flange at each end of

the quill from which seven pins project and fit into the hubs of

the driving wheels. On the direct-current part of the line, current

is delivered to the car through eight collecting shoes from a third

rail. On the alternating-current section, current is delivered through

two pantograph bow trolleys. On the direct-current section the

series-parallel method of speed control is used, current being fed

directly to the motors which are connected two in series permanently

and the series-parallel control is applied to the motors in groups of

two. The alternating-current speed control is accomplished by six taps

from an auto-transformer for the corresponding running points. The cars

weigh 78 tons and are capable of a speed of 60 to 65 miles per hour.

The electro-pneumatic unit-switch type of control is used. At each

end of the cab is a master controller from which the main controller

is operated. Several locomotives can be operated together on the

multiple-unit system, if desired.

[Illustration: Six-Unit Switch Group, Single-Phase System.]

The Washington, Baltimore and Indiana single-phase road is the latest

in the field, contracts having been placed very recently. The current

will be transmitted at 33,000 volts and 25 cycles, then being stepped

down to 6,600 volts on the trolley. The road will be 60 miles long and

will be equipped with General Electric apparatus. Four 125-H. P. motors

capable of operating on either alternating current or direct current

will be used, and the cars will be capable of a speed of 60 miles per

hour.

INDEX

Air brakes, 56

Air compressors, 57

automatic governor for, 57

Westinghouse, 58

Alternating-current generators, 105

Alternating-current switchboards, 110

Alternating-current systems, 113

single-phase motors, 114

three-phase motors, 113

Alternating-current transmission, 99

Armature coils, 8

Armature leads, 9

Armature tests for grounds, 133

Armature winding, 5

defects of, 124

mistakes in, 126

Automatic governor for air compressors, 57

Ballast, 85

Bearings of railway motors, 13

Block signals for electric railways, 94

Bond testing, 120

Bonding and return circuits, 88

Booster feeder, 98

Brackets, 75

Brake leverages and shoe pressure, 54

Brake rigging, 53

Brake shoes, 64

Brush holders, 10

Brushes, 10

Burn-outs, 123

Canopy switch, 39

Car, failure of to start, 127

Car bodies, 67

Car circuit breaker, 39

Car construction, 67

Car equipment, 3

Car heaters, 34

electric, 34

hot-water, 36

Car painting, 72

Car repair shops, 134

Car weights, 72

Car wheels, 51

Car wiring, 37

Cast-welded joints, 87

Coefficient of friction, 65

Common T-rail, 84

Commutator type single-phase motor, 139

Compressors, 57

Conductivity of steel rail, 80

Conduit systems, 81

contact plow, 82

cost of, 82

current leakage, 83

Contact plow, 82

Contact shoes, 45

Controller construction, 19

Controller notches, 27

Controller wiring, 20

Controllers, 16

Cost of power, 119

Couplers, 66

Current required to heat cars, 35

Current leakage, 83

Defects of armature windings, 124

Direct-current feeding, 98

Double-current generators, 105

Drawbars, 66

Economy in power, 118

Electric car accessories, 39

canopy switch, 39

car circuit breaker, 39

contact shoes, 45

fuses, 41

lamp circuits, 43

lightning arresters, 41

trolley base, 44

trolley poles, 44

trolley harp, 45

trolley wheels, 44

Electric cars, road tests of, 117

Electric heaters for cars, 34

Electric railway, 1

Electrically welded joints, 87

Electrolysis, 95

prevention of, 97

Feeder panel, 110

Feeder systems, 92

Feeders, 75

Field coils, 8

Field tests for grounds, 133

Four motors, 19

Fuse blows, 130

Fuses, 41

Gearing, 12

G. E. electric brake, 61

G. E. train control, 29

Generator, starting up, 108

Generator D. C. panels, 106

Generators, 105

Girder rail, 83

Grounds, 123

High-tension lines, 77

High-tension oil switches, 111

Highway crossings, 80

Hot-water heaters for cars, 36

Insulators, third rail, 79

Interurban railway, system of distribution for, 101

Joints for rails, 86

Lamp circuits, 43

Lightning arresters, 41

Locating defects in motor and controller wiring, 128

Location of

power houses, 101

third rail, 79

Lubrication of railway motors, 13

Magnetic blow-out, 26

Maximum traction trucks, 51

Momentum brakes, 59

Motor leads, 9

Motor suspension, 14

Motor-coil testing, 121

Motors, 3

as emergency brakes, 63

of the New York Central electric locomotive, 15

Multiple-unit control, 29

Oil switches, high tension, 111

Open-circuit tests, 128

Opening cases for inspection, 10

Overhead construction, 73

brackets, 75

feeders, 75

high-tension lines, 77

section insulators, 76

span wires, 74

trolley wire, 73

trolley-wire clamps and ears, 73

Potter third-rail shoe, 46

Power

cost of, 119

economy in, 118

taken by cars, 115

Power house location, 101

Power stations, general plan of, 105

Power supply and distribution, 98

Railway motors

bearings, 13

brushes, 10

characteristics of, 3

gearing of, 12

lubrication of, 13

Rate of retardation in braking, 66

Resistance of track, 91

Resistances, 38

Return feeders, 92

Reversal of motor, 26

Reversed fields, 133

Rheostat control, 17

Road tests of electric cars, 117

Sectional insulators, 76

Series-parallel control, 17

Shanghai T-rail, 84

Short-circuit tests, 130

Single trucks, 48

Single-phase electric railway, 136

Single-phase motors, 114, 139

Sleet on trolleys and third rails, 46

Sliding and spinning wheels, 119

Span wires, 74

Sparking at the commutator, 127

Sprague multiple-unit system of control, 29

Steel car framing, 71

Storage air brakes, 58

Storage batteries in stations, 113

Street railway motors, general data on, 6

Supplementary return feeders, 92

Swing bolster trucks, 49

Switchboards, 106

alternating-current, 110

Switches, third rail, 79

Swivel trucks, 48

T-rail, 84

Thermit welding, 88

Third rail, 79

advantages in operation, 80

Third rail

conductivity of, 80

cost of, 80

highway crossings, 80

insulators for, 79

location, 79

switches, 79

Three-phase motors, 113

Track brakes, 63

Track construction, 83

Track resistance, 91

Track sanders, 65

Track support, 85

Transmission systems, efficiency of, 101

Trilby groove rail, 84

Trolley base, 44

Trolley harp, 45

Trolley poles, 44

Trolley wheels, 44

Trolley wire, 73

Trolley-wire clamps and cars, 73

Trucks, 46

maximum traction, 51

single, 48

swing bolster, 49

swivel, 48

Type L controllers, wiring of, 24

ANNOUNCEMENT OF COMING

BOOKS

PRACTICAL +AND+ SCIENTIFIC

=CARPENTRY. By G. Townsend.= 150 pp., 224 illus. A working manual

for Carpenters and Woodworkers in general. Not a theoretical

treatise, but a _practical working guide_. Price, =$1.00=

=GAS ENGINES AND PRODUCERS. By Marks and Wver.= 150 pp., 90

illus. Latest information in this rapidly developing field. For

Engineers, Machinists, Automobilists. Price =$1.00=

=MASONRY CONSTRUCTION. By Phillips and Byrne.= 140 pp., 44 illus.

Latest and best American methods. Price =$1.00=

=WATER SUPPLY. By F. E. Turneaure.= 150 pp., 40 illus. An

exhaustive compendium for Sanitary and Waterworks Engineers and

all interested in matters affecting public health. Price =$1.00=

=HIGHWAY CONSTRUCTION. By Phillips and Byrne.= 140 pp., 80 illus.

Modern methods for Road Builders and all interested in better

ways of communication. Price =$1.00=

=REINFORCED CONCRETE. By Webb and Gibson.= 150 pp., 140 illus.

A manual of practical methods for Architects, Builders.

Contractors, Civil and Sanitary Engineers. Information for the

first time made known to the world. Based on recent construction

work, special tests, etc. Price =$1.00=

=MANAGEMENT OF DYNAMO-ELECTRIC MACHINERY. By F. B. Crocker.= 130

pp., 65 illus. For all who have to do with electric light or

power plants. Price =$1.00=

=STEAM ENGINES. By Leland and Snow.= 170 pp., 63 illus. A practical

guide. Field covered in a way anyone can grasp. Price =$1.00=

=ELECTRIC RAILWAYS. By J. R. Cravath.= 150 pp., 103 illus. Trolley

and third-rail systems. Electric Locomotive, etc. Price =$1.00=

=ESTIMATING. By Edward Nichols.= 140 pp., 35 illus. For all workers

in Building trades. Tells how to estimate intelligently. Price

=$1.00=

=CONTRACTS AND SPECIFICATIONS. By James C. Plant.= 130 pp.,

fully illustrated. Forms of public and private contracts,

specifications, bonds, etc., duties and responsibilities of

Architects, Contractors, and Owners. Price =$1.00=

=STAIR-BUILDING AND STEEL SQUARE. By Hodgson and Williams.= 130

pp., 180 illus. Only up-to-date work on these subjects. Price

=$1.00=

=VALVE GEARS AND INDICATORS. By Leland and Dow.= 150 pp., 105

illus. Two books in one. Types of valves, gears, etc., fully

explained. Price =$1.00=

=STRENGTH OF MATERIALS. By E. R. Maurer.= 140 pp., 58 illus. For

Architects, Builders, Steel and Concrete Workers. Enables one to

avoid mistakes. Price =$1.00=

=THE ELECTRIC TELEGRAPH. By Thom and Collins.= 150 pp., 81 illus.

Carries along by easy steps to complete mastery. Multiplex and

Wireless telegraph explained. Price =$1.00=

=MECHANICAL DRAWING. By E. Kenison.= 160 pp., 140 illus.

Complete course in projections, shade lines, intersections and

developments, lettering, with exercises and plates. Price =$1.00=

=POWER STATIONS AND TRANSMISSION. By G. C. Shaad.= 160 pp., 43

illus. For Electrical Workers. Up-to-date practice. Price =$1.00=

=PATTERN MAKING. By James Ritchey.= 150 pp., 250 illus. For Wood

and Metal Workers and Molders. Methods of building up and

finishing, fully described. Price =$1.00=

=SURVEYING. By Alfred E. Phillips.= 200 pp., 133 illus. For Civil

Engineers and Students. All details of field work explained.

Price =$1.50=

=STEEL CONSTRUCTION. By E. A. TUCKER.= 300 pp., 275 illus. Covers

every phase of the use of steel in structural work. Based on

actual experience, special tests, etc. For Architects, Bridge

Builders, Contractors, Civil Engineers. Price =$1.50=

=BUILDING SUPERINTENDENCE. By E. Nichols.= 200 pp., 250 illus.

Costly mistakes occur through lack of attention at proper time,

hurtful to Owner and discreditable to Architect and Builder.

Gives thorough knowledge of methods and materials. Price =$1.50=

=ARCHITECTURAL DRAWING AND LETTERING. By Bourne, von Holst and

Brown.= 200 pp., 55 drawings. Complete course in making working

drawings and artistic lettering for architectural purposes. Price

=$1.50=

=MACHINE SHOP WORK. By F. W. Turner.= 200 pp., 200 illus. Meets

every requirement of the shopman, from the simplest tools to the

most complex turning and milling machines. Price =$1.50=

=TOOL MAKING. By E. R. Markham.= 200 pp., 325 illus. How to make,

how to use tools. Profusely illustrated. Price =$1.50=

=MACHINE DESIGN. By C. L. Griffin.= 200 pp., 82 designs. Written by

one of the foremost authorities of the day. Every illustration

represents a new device in machine shop practice. Price =$1.50=

Electric railways · 第 10 / 11 段