There are several types of multiple-unit control. In all of them there

is on each car a controller of some kind which controls the current

flowing to the motors on that car. This controller is operated from

a distance by means of electro-magnetic or electro-pneumatic devices

controlled by circuits called _pilot circuits_, which circuits are

connected to the motorman’s controller. All the pilot circuits of a

train are connected together by means of train plugs which make the

connections between the cars. The pilot circuits of each car are

connected to a motorman’s controller on that car and this makes it

possible to operate the train from any controller.

=Sprague Multiple-Unit System.= In the earliest form of multiple-unit

control—which was that devised by F. J. Sprague—the motors on each car

were controlled by an ordinary Type K controller, which had geared to

its shaft a small pilot motor. The pilot motor was controlled by the

pilot circuits connected with the motorman’s controller.

In the more recent forms of multiple-unit control, the use of main

controllers having contact cylinders has been practically abandoned.

The contacts are made instead by a number of electro-magnetic or

electro-pneumatic contact devices sometimes called _contactors_.

=General Electric Train Control.= In the General Electric train-control

system each contact for the motor circuits is made by a solenoid magnet

which draws together two heavy copper contact fingers to establish the

circuit. A magnetic blow-out coil in series with the contact is also

provided. The contactors make contact only when energized by a small

amount of current from the master or motorman’s controller. In Fig.

28_a_ is a diagram of the car wiring for a motor car equipped with

this system. The motorman’s controller is a drum controller, but is

comparatively small since it has to handle only the small amount of

current necessary to operate the solenoid magnets of the contactors.

It is evident that by connecting together the pilot circuits, which

are connected to the motorman’s controller, so that the pilot circuits

will be continuous for the entire length of the train, any number

of cars equipped with the train-control system can be operated; and

similar contacts will be made by the contactors under all the cars

simultaneously, by virtue of the circuits established by the master

controller at any platform.

Besides controlling the contactors, the master or motorman’s controller

must control an electro-magnetic reversing switch, or _reverser_, to

change the direction of car travel.

The handle of the motorman’s controller is provided with a push button,

which must be depressed while the current is turned on. Should the

motorman release this push, the circuit through the controller will be

opened and all the contactors will fall open. This handle is called the

_dead man’s handle_ because it is put there to provide for cutting off

the current should the motorman fall dead or in a faint at his post.

The flow of the current in the control circuits, which operates the

reverser and picks up the contactors on the several points may be

followed in the diagram Fig. 28_a_. With the reverse handle in the

forward position and the controller on the first point, current passes

from the main circuit through a single-pole fused switch called the

control switch and through the auxiliary blow-out coil to a finger

bearing on the upper section of the master controller cylinder by which

connection is established to the adjacent finger and thence to the

reverse cylinder. It leaves this over wire No. 8, passing by way of the

connection board and control cut-out switch to the forward operating

coil of the reverser, thence through the forward blow-out coil and over

wire 81, through the switch underneath contactor No. 2 and to ground G,

by way of wire B 2 after passing through the fuse shown. The current

through the operating coil of the reverser, having thrown this, the

path is changed somewhat. The current then instead of passing from

the reverser over wire 81, is conducted through wire 15, through the

operating coils of contactors No. 1, 2, 3, and 11 in series, through

the switch under contactor No. 12, and to ground through finger 1 of

the controller. Contactors 1 and 2 are in multiple and when raised

connect the trolley with the contactors controlling the resistance

leads. Contactor 3 connects R to the line while contactor 11 places

the two motors in series. The motors then operate with all of the

resistance in circuit. When contactor 2 raises, it opens the switch

immediately below it, making it impossible for the reverse to operate

while current is flowing through the motors. On the second notch of

the controller an additional path is opened by way of finger 3 of the

controller. This path leads from finger 3 through four of the control

circuit rheostat coils, through contactor No. 5 and to ground over 32.

On the 3rd, 4th and 5th points contactors 6, 7 and 9 respectively are

raised. The motors are then in full series. Between the 5th and 6th

points all the control circuits are broken preparatory to starting the

multiple connections of motors. On the 6th or the first multiple point

the ground through finger 1 of the master controller is opened while a

ground through finger 3 is established. The current from the reverser

then, after raising contactors 1 and 2 as before, instead of passing

through contactors 3 and 11, passes through the coils of 4, 12 and 13,

through the switch under contactor 11 and to ground over finger 2.

Contactor 12 connects motor No. 2 to R₇, while contactor 13 grounds No.

1 motor. The motors now operate in parallel and on successive notches

of the controller, contactors 6, 7, 8, and 9 are raised, cutting out

all of the resistance. The switches underneath contactors 11 and 12

make it impossible for 11 to raise with 12 and 13 or vice versa. The

reason for this arrangement is very evident, as a direct ground for R₇

would result.

=The Westinghouse Electro-Pneumatic System of Control.= In this system

of multiple unit or train control, the current to the motors is

supplied through a set of unit switches or circuit breakers which are

sometimes placed in a circular case or turret underneath the car and in

other cases are ranged in a row under the car. The opening and closing

of these unit switches is done with compressed air acting on a piston

in an air cylinder. When the circuit is to be closed, compressed air

is admitted behind the piston and forces it down against the tension

of a seventy-pound spring, and the contacts are brought together.

When the switch is to be opened, the air is let out of the cylinder

and the spring forces the piston back. The air supply is obtained

from the storage tanks of the air brake system. The valve controlling

the air supply to the cylinder of each unit switch is operated by

electromagnets which derive current from a seven cell, fourteen-volt,

storage battery. The small master controller operated by the motorman,

makes and breaks the battery connections to the magnets controlling the

air valves.

[Illustration: Fig. 28b. Car Wiring for Westinghouse Control System.]

An advantage of this over other multiple-unit systems is that by

the use of battery current the control system is not disturbed by

interruptions of the main supply of current. The chief advantage of

this is that it makes it possible to reverse the motors and operate

them as brakes in emergencies at all times.

The battery is charged from the main line through lamps as resistance,

or may be charged by being connected in series with the air compressor

motor.

In the accompanying diagram, Fig. 28_b_, there are two batteries

shown which are charged in series with the compressor motor. By means

of two double-pole, double-throw switches, first one and then the

other battery is connected for charging and for service. The battery

is charged in shunt with a resistance and a relay is connected in

the circuit as shown, so as to open the battery circuit whenever

the current through the motor stops, and thus prevent the battery

discharging through the resistance.

The master controller has a double set of segments in order to decrease

the length of the shaft. The handle, therefore, is moved only one-sixth

of a revolution from off to full speed. The various circuits can be

traced by the letters and numbers each wire bears, so that the circuits

will not be gone over in detail. The first position of the master

controller throws the reverser switch in the proper direction and

also closes the main circuit breaker. On the second point the motors

are connected in series with all resistance in circuit, and these

resistances are automatically cut out one by one. On the next point

of the controller the motors are in multiple and the resistances are

automatically cut out in a similar manner. The automatic cutting out

of resistances is accomplished by a limit switch in conjunction with

operating and holding coils on the electro-pneumatic valves. This

limit switch is a kind of a relay which has the current from one of

the motors flowing through its coil and which acts to open a certain

battery circuit which operates the electro-pneumatic valves whenever

the current in the motor circuit in question exceeds the amount for

which the limit switch is set. The automatic acceleration or cutting

out of resistance is accomplished as follows:

Each electro-pneumatic valve has two magnet coils, one of which is

an operating coil and the other a holding coil for holding the valve

open after it is operated. When first the current flows through a

circuit to one of the electro-pneumatic valves, it flows through the

operating coil and operates the valve to close the corresponding

switch or switches of the main circuit by turning the air into the

cylinders. As soon as the main switch is closed, it cuts into circuit

the holding coil of its corresponding electro-pneumatic valve and

this coil will, with the battery current, hold the switch closed even

though the circuit to the operating coil may be opened momentarily by

the limit switch as each step of resistance is cut out. This prevents

the switches from opening when they are once closed and allows the

operating coils to open an air valve each time the current through

the limit switch coil falls below the amount for which it is set. The

contacts which close the holding coil circuit on each valve whenever a

main switch is closed, are called interlocks and are indicated on the

diagram.

[Illustration: Fig. 29. Diagram of Electric Heaters.]

The main line circuit breaker, which is electro-pneumatically operated,

will open automatically on overload and can be reset by the motorman

on all the cars of a train by closing a switch located beside each

controller.

CAR HEATERS.

=Electric Heaters= for warming cars in winter, consist of iron wire

coils which are warmed by the passage of electric current through

them. The heat so evolved varies as the resistance multiplied by the

square of the current. The iron wire coils of the heater are mounted on

non-combustible insulating supports, and are arranged so that there is

a free circulation of air through them. The coils are surrounded with

a perforated metal case, the object of which is to prevent injury to

the coils and to prevent persons or clothing coming in contact with the

hot, live wires of the coils. Heaters are sometimes arranged so that

they can be connected in series or parallel to give different degrees

of heat.

The diagram, Fig. 29, shows the most common arrangement of electric

heaters recently. The tap from the trolley should be taken off on the

trolley side of the circuit breaker. After passing through a fuse the

circuit goes to the switch. Each of the heaters contains two coils,

one of higher resistance than the other. Two independent circuits

are run from the switch, through the heaters and to the ground. One

circuit passes through the high resistance coils of the several heaters

while the other goes through the low resistance coils. The switch

has three points. On the first point a circuit is made through the

high resistance coils. The second point connects the low resistance

coils while the third point puts both circuits in service. With this

arrangement three gradations of heat may be obtained.

To avoid complicated wiring sometimes but one circuit is employed. In

such a case the heat must either be all on or off, no gradations being

possible.

The chief difficulty encountered with electric heaters is the breaking

of the wires because of the scale of oxide that forms gradually when

they are run at a high temperature or because of water striking them

from passengers’ clothing on wet days, which causes the wires to snap.

The Consolidated Car Heating Company gives the following data on the

current required to heat cars:

====================+=================+=================

| Length of Car | Amperes.

| Body. +-----------------

| |Switch Positions.

| +-----------------

| | 1 2 3

--------------------+-----------------+-----------------

| { 14 to 20 feet | 3 4 7

Average conditions | { 20 to 28 ” | 3 6 9

| { 28 to 34 ” | 4 7 11

| |

Severest conditions | { 18 to 24 feet | 4 7 11

| { 28 to 34 ” | 6 8 14

--------------------+-----------------+-----------------

In his Electrical Engineers’ Hand Book, Mr. Foster gives results of

tests made on Brooklyn cars as follows:

=========================+================+====================

Cars. | Temperature F. | Consumption.

-------+--------+--------+----------------+--------------------

Doors. |Windows.|Contents|Outside.|Average|Watts.| Amperes

| | cu. ft.| |in car.| |at 500 volts.

-------+--------+--------+--------+-------+------+-------------

2 | 12 | 850½ | 28 | 55 | 2295 | 4.6

2 | 12 | 850½ | 7 | 39 | 2325 | 4.6

2 | 12 | 808½ | 28 | 49 | 2180 | 4.3

2 | 12 | 913½ | 35 | 52 | 2745 | 4.5

4 | 16 | 1012 | 7 | 46 | 3038 | 6.

4 | 16 | 1012 | 28 | 54 | 3160 | 6.3

-------+--------+--------+--------+-------+------+-------------

When not watched carefully considerable current may be wasted by

allowing the heaters to remain turned on when not needed. Many

companies hang out signs where motormen may observe them, indicating

when the heaters shall be turned on and to what point.

[Illustration: Fig. 30. Electric Heater.]

The best practice in electric heating is to have plenty of heaters and

run the wire at a low temperature, rather than attempt to heat with a

few at high temperature. The greater the number of heaters the larger

the radiating surface around which the air can circulate and a given

amount of car heating can be accomplished with less current than with a

few high temperature heaters. The depreciation of the heater wires is

less the lower the temperature at which they are operated. An electric

heater is shown in Fig. 30.

=Hot-Water Heaters= are frequently used on large electric cars.

Hot-water pipes are placed along the sides of the car, and connected

with a stove containing hot-water coils at one end of the car.

The water, as it is heated in the stove or heater, expands, and

consequently becomes lighter per cubic inch or other unit of volume;

it therefore tends to rise when balanced against the colder water in

the car pipes. Hot water leaves the top of the heater, flows up to

an expansion tank and then down through the car piping, and back to

the bottom of the heater. The car piping slopes continuously down from

the top connection to the bottom connection of the heater. At the top,

an opening to the atmosphere is provided through a small water tank,

called an _expansion tank_. This prevents water pressure bursting the

pipes as they become heated, and allows any steam that may have formed

to escape. The most modern hot-water heaters for cars are completely

closed except as to the ash pit at the bottom and a small feed door in

the top. The latter is locked so that the fire cannot come out even

if the car is tipped over in a wreck. Fig. 31 shows the pipes of a

hot-water heating installation.

[Illustration: Fig. 31. Pipes for Hot-Water Heating.]

CAR WIRING.

The wires from motors to controllers, when placed in exposed position

under the car, are bunched in cables or covered with hose. In some

cases special runways are provided in the bottom of the car to

accommodate the car wiring. All the wiring in a car should be heavily

insulated with moisture-proof rubber-covered wire, and further

protected from mechanical abrasion by a tough outer covering.

Stranded rubber insulated wire is used almost exclusively for wiring

all parts of the car. A general idea of the path of the motor circuit

wiring may be obtained by reference to Fig. 22. The main lead after

leaving the trolley stand is cleated to the trolley board on top of

the car. At the end of the car it passes through the roof and to the

circuit breaker. On leaving the breaker it is led down a post, through

the floor and to the choke coil and lightning arrester underneath the

car. It then passes to the trolley terminal of the controller.

The tap for the light wiring (although shown otherwise in the drawing)

is usually taken off the main circuit before the circuit breaker is

reached. This arrangement allows the lamps to be burned when the

circuit breaker is open. After passing through fuses and switches in

the motorman’s cab the circuit for the lights is led through the car in

moulding concealing it.

The wires running between the motors, controllers and resistance

frames underneath the car, as has been stated, are often carried in

canvas hose. Usually two cables are made up, for should all the wires

necessary be placed in one cable this would become too bulky to be

properly cleated up. To make the canvas hose waterproof and to prolong

its life it is usually given several coats of asphaltum paint.

The wiring of the new cars of the New York subway is an example of

the most advanced practice. All the wires under the cars are carried

in “loricated” conduit, which consists of a wrought-iron tube heavily

enameled both inside and out. The motor leads and the other larger

wires are carried in separate conduits. The conduits are usually hung

to the steel beams of the floor framing by strap bolts. This method of

wiring gives a reasonable assurance that it will not become defective.

Moreover, it lessens fire risk. The conduits are all grounded and

should one of the wires come in contact with the conduit carrying it,

the dead ground resulting would cause the fuse to blow instantly, and

all danger would cease.

RESISTANCES.

The type of resistance now most common for heavy motor equipment is in

the form of cast-iron grids, which are assembled together and connected

in series. These grids are sufficiently stiff to render unnecessary any

solid insulation between them, and hence they can radiate heat to the

best advantage. The only difficulty experienced with them is from the

warping or cracking. Resistances for lighter equipment are composed of

sheet-steel ribbons wound in coils. Each turn of a coil is insulated

from the next by asbestos. Other forms of sheet-steel resistance with

asbestos insulation between the turns, have also been used. In Fig. 32

is shown a Westinghouse grid type diverter for street railway equipment.

ELECTRIC CAR ACCESSORIES.

=Canopy Switch.= An overhead switch, sometimes called a “canopy

switch,” is commonly placed over each street-car platform where

a controller is located, usually in the deck or canopy above the

motorman’s head. This is simply a single-point switch that may be used

by the motorman to cut the trolley current off from the controller

wiring so that the controllers will be absolutely dead. When two such

switches are used, one on each end of the car, they are connected in

series.

[Illustration: Fig. 32. Grid Type of Resistance.]

=Car Circuit Breaker.= Frequently on large equipments an automatic

circuit breaker is provided instead of this overhead switch. This

circuit breaker can be tripped by hand to open the circuit whenever

desired; and is also equipped with a solenoid magnet, which can

be adjusted so that it will trip or open the circuit breaker at

approximately whatever current it is set for. This circuit breaker

protects the motor and car wiring from excessive current, such as would

occur in case of a short circuit in motors or car wiring, or in case

the motorman turned on current so rapidly as to endanger the windings

of the motors. Circuit breakers, however, are most commonly used on

cars having controllers located at only one end in a motorman’s cab.

=Wiring of Circuit Breakers and Canopy Switches.= Figs. 33, 34, and 35

show the methods of wiring circuit breakers and canopy switches for

double-end cars.

[Illustration: Fig. 33.]

In the parallel connection as shown in Fig. 33, the trolley leads after

passing through the choke coils go directly to the blow-out coil of the

controllers. Aside from the fact that two lightning arresters and choke

coils are required, this method is preferable for automatic circuit

breakers.

[Illustration: Fig. 34.]

Fig. 34 shows the hand-operated circuit breakers connected in series.

This method is used where non-automatic breakers are employed, but for

automatic breakers it has the objection that an overload would throw

the breaker set at the lowest point. This might be the breaker on the

opposite end to that occupied by the motorman and in such an event

would necessitate a trip to the other end to set the breaker. Fig.

35 shows a method of parallel connection requiring but one lightning

arrester. This method has the objection that the motorman on the front

end would have no assurance that by throwing the breaker over him the

power would be cut off. The rear breaker might have been carelessly

left set.

[Illustration: Fig. 35.]

[Illustration: Fig. 36.]

=Fuses.= A fuse is placed in series with the motor circuit before it

enters the controller wiring, but where circuit breakers are used

instead of canopy switches, the fuse box may sometimes be dispensed

with. The fuse box on street cars is usually located underneath one

side of the car body where it is accessible for replacing fuses, but

where a motorman’s cab is used, the fuse may be placed in the cab. The

fuse may be of any of the types in common use, either open or enclosed.

In the Westinghouse fuse box it is necessary only to open the box

and drop in a piece of straight copper wire of the right length and

size. The closing of the box clamps this wire to the terminals and

establishes a circuit through the copper wire as a fuse. Of course this

copper wire is of small enough size to be fused by a dangerously heavy

current.

=Lightning Arresters.= A lightning arrester is used on all cars taking

current from overhead lines. The lightning arrester is connected to

the main circuit as it comes from the trolley base, before it reaches

any of the other electrical devices on the car, so that it may afford

them protection. A common type of lightning arrester is shown in Fig.

36. One terminal of the lightning arrester is connected to the motor

frame so as to ground it, and the other is connected with the trolley.

In most forms of lightning arrester, a small air gap is provided, not

such as to permit the 500-volt current to jump across, but across which

the lightning will jump on account of its high potential. To prevent

an arc being established across the air gap by the power house current

after the lightning discharge has taken place and started the arc, some

means of extinguishing the arc is provided. In the General Electric

Company’s lightning arrester, the arc is extinguished by a magnetic

blow-out, which is energized by the current that flows through the

lightning arrester. The instant the discharge takes place the current

flows across the air gap. The magnetic blow-out extinguishes the arc,

and this opens the circuit, leaving the arrester ready for another

discharge. In the Garton-Daniels lightning arrester a plunger contact

operated by a solenoid opens the circuit as soon as current begins to

flow through the arrester. This plunger operates in a magnetic field,

which extinguishes the arc. A choke coil, consisting of a few turns

of wire around a wooden drum, is placed in the circuit leading to the

motors at a point just after it has passed the lightning arrester tap.

This choke coil is for the purpose of placing self-induction in the

circuit, so that the lightning will tend to branch off through the

lightning arrester and to ground, rather than to seek a path through

the motor insulation to ground.

[Illustration: Fig 37. Diagram of Light Circuit.]