CHAPTER VIII

WAREHOUSES.

WAREHOUSE DESIGN -- FLOOR AREA -- FIRE PROOF BUILDINGS -- FLOOR

CONSTRUCTION -- COOLERS -- FAN AND VENTILATION -- SPRAY SYSTEM --

GALVANIZED SHEET IRON PIPES -- COIL ROOMS -- QUANTITY OF PIPE --

METHOD OF ERECTING -- LIFE OF PIPE -- CELLAR CEILING SUSPENSION --

RATIO OF PIPING -- DEFROSTING -- GARDNER CURTAIN SYSTEM -- DIRECT

EXPANSION PIPING -- CHILL-ROOM BUNKERS -- LOW TEMPERATURE BRINE

SYSTEM -- FREEZER AND STORAGE BUILDINGS.

=Warehouse Design.=--Under this heading we will discuss the standard

pork building for curing meats and for chilling hogs.

=Floor Area.=--The warehouse building as usually laid out should

provide 10,000 square feet on each floor, and as many stories in height

as needed and as many units as needed. It is common and usually best

to set posts sixteen feet centers in each direction, making sections

sixteen feet square. This area seems to lend itself best to practical

usage in packing house work.

=Fire-Proof Buildings.=--The permanence of the premises, the value of

the product in storage, and many other points make the advocacy of

fire-proof warehouses commendable. The warehouse, where floors are

likely to be used for storing moist or wet goods, or for curing meats,

should preferably be solid concrete floors, rather than tile, with

concrete joists and concrete topping.

=Floor Construction.=--The ideal packing house floor is as yet to be

discovered. What appears to be the best in a warehouse is a monolithic

floor, treated under the zones where meats are to be piled, and all

trucking thoroughfares paved with brick or tiles, or perhaps an

asphaltum preparation, as the latter can be replaced.

=Coolers.=--In most instances it is best to arrange the coolers on one

or more of the upper floors. Cooler design varies, but late practice

has been drifting back to the old system of open spray brine which is

described elsewhere. The customary practice in the United States is

for some type of natural circulation, as by the use of ducts with air

chilling facilities above the chill rooms. Practice has proven for

fresh meats that the use of this system is far superior to that of

forced draft, sometimes called “indirect” refrigeration.

=Fan and Ventilation.=--In northern climates it is a good practice

to place a window at each end of the pipe or brine loft to admit

a circulation of air during cold weather, locating an exhaust fan

centrally over the coolers with a duct connecting with the fan from

each room, drawing air from either end toward the center via the open

windows in the end of the loft. This induces a circulation through the

hot and cold air ducts which produces quite sufficient circulation and

a uniformity of temperature in the contents in the room below.

In warm climates the use of roof plugs, and airing or venting the

cooler at each filling, is, in our judgment, an expensive method, and

not justified by the results obtained.

=Spray System.=--The “spray system” has been rejuvenated and is very

popular. This system is particularly effective for warm beef and sheep

coolers and for hog coolers. It can well be installed at slaughter

and shipping points, but its use in hanging rooms where beef is aged

and held for sale is questionable, by reason of the probability of

shrinkage owing to the rapid air circulation maintained.

_Width of Rooms._--There are various opinions as to the width and

height required in a bunker room for installation of the spray

system. A room from thirty-two feet to forty-eight feet wide can be

successfully operated. Increased width beyond that means increased

height and this, in turn, means more construction cost.

Rooms twenty-five feet wide with twenty feet pans have been built and

successfully operated, but at less widths the brine is likely to carry

over. The value of the spray system, and the rapidity with which a

room and its contents can be cooled by its use, seems to be due to two

causes, the direct contact of the air with the finely divided brine

spray and the induced air currents created by a mechanical circulation.

[Illustration: FIG. 22.--SECTION OF COLD STORAGE HOUSE EQUIPPED WITH

SPRAY SYSTEM.]

_Types of Construction._--The accompanying diagrams show two types

of construction. One wherein the brine pan is made of cast concrete

and the rails suspended from wood rail beams hung on rods attached

to the ceiling. The other one shows the brine pan made of wood built

up from supported rail beams. In the first instance the brine spray

is collected on what might be termed a composition roof (without the

gravel covering) made from asphalt saturated paper, and asphalt laid

over a cork sub-base spread upon and cemented to the concrete pan.

In the second instance the pan is made from wood, exhibiting a wood

paneled surface on the underside, covered with cork, more wood and then

lined with a galvanized iron pan.

_Arrangement of Piping._--In both instances the brine spray header

was located near the top of the hot air flue partition and the sprays

directed to a line below the horizontal, to insure the brine falling

well within the pan, to prevent splash through the cold air flue.

The brine is collected and returned through a main pipe to the brine

tank in which are placed the submerged coils.

_Salt Brine--Calcium Brine._--One system is operated on salt brine in

which the accumulation is sterilized by boiling, then filtered and used

for curing purposes. The other is operated on calcium brine which is

concentrated by passing over a concentrator. It is then returned to the

brine tank.

_Spray Devices._--There are various spray devices purchasable on the

market, some approaching atomizers. The owner usually selects something

to his taste. A common spigot can be used with a piece of bent tin to

distribute the brine at the outlet, but more efficient devices are

obtainable.

The location of the nozzles at a distance of about four feet apart

seems to be ample for most purposes. The outlet opening should be about

one-half inch, valve controlled to suit. It is well to arrange long

length of pipe so that each cock is supplied with an equal quantity of

brine by use of forked connections on a complete supply circuit.

=Galvanized Sheet Iron Pipes.=--For room cooling, formerly used to a

considerable extent was sheet iron pipes. The three-inch galvanized

iron spiral riveted pipe is recommended, or where this is not readily

obtainable three-inch galvanized iron crimp-joint and soldered seam

pipe may be substituted. While not quite so substantial as the spiral

riveted pipe, it will, with ordinary care and attention last a long

time.

The use of spiral riveted pipe has been found unnecessary, provided

No. 24 gauge metal is used in lock seamed pipe. Open-hearth steel,

galvanized, is preferable to Bessemer. The writer experienced one

failure with the latter.

[Illustration: FIG. 23.--SECTION SHOWING BRINE SALT AND SPRAY SYSTEMS.]

Ten different pieces of this pipe ten feet long were capped on either

end and submitted to a hydrostatic pressure test; the bursting pressure

average of the ten pieces was found to be 146 pounds to the square

inch, while some of the samples stood a pressure of over 180 pounds to

the square inch. In actual practice the pipe used for this purpose is

never subjected to a pressure exceeding forty pounds to the square inch.

=Coil Rooms.=--Fig. 24 shows the end view of the cooler with the detail

of the hangers on which the pipe rests. Fig. 25 shows the end view of

one bay with the pipe located and connected.

[Illustration: FIG. 24.--END VIEW OF COOLER; DETAIL OF PIPE HANGERS.]

=Quantity of Pipe.=--In brine pipe refrigeration for cattle the author

would recommend to each sixteen-foot bay, eight series of three-inch

galvanized spiral riveted pipes with six pipes in each series. These

make a total of forty-eight pipes for the fore-cooler, where the

largest proportion of pipe is needed, and forty pipes per section in

storage beef cooler. For hog coolers forty-eight pipes per section

throughout is recommended.

[Illustration: FIG. 25.--END VIEW OF BAY SHOWING REFRIGERATING PIPE

HUNG TO CEILING.]

=Method of Erecting.=--Adoption of this system where brine circulation

is used can be made for meat storage rooms. (See Fig. 26 for detail

of the end pipes with fittings for the hose connections.) Pipes are

usually furnished in ten-foot lengths, riveted and soldered, and are

slipped together like ordinary stovepipe joint, all of these slip

joints being carefully soldered to be brine tight, a sufficient number

joined together to make runs of the required length to suit the pipe

chamber. At the end of the runs one of the three hose connection

fittings shown in Fig. 26 (feed connection, intermediate connection and

return connection) is put on for the purpose of connecting the runs

together by means of the rubber hose. Chatterton’s compound is put on

the nipple of the fitting connection quite warm, the hose being slipped

over at once and a wire clamp then put around the hose very tightly,

when the connection is complete.

[Illustration: FIG. 26.--DETAIL OF END PIPES, SHOWING DIFFERENT

FITTINGS.]

=Life of Pipe.=--This pipe is recommended for the following reasons:

First, for its economy; second, for its lasting qualities. As proven

by experience, galvanized pipe will last fully twice as long as

the ordinary black iron pipe. This would hardly seem possible when

first considered by anyone not having had the experience, and would

naturally seem contrary to his judgment. There was installed in 1890

over 100,000 lineal feet of this light galvanized pipe in a Chicago

plant, some of which is still in use.

Samples of the galvanized pipe that had been in use for upward of ten

years were found to have a very slight coating or deposit of rust on

the inside of the pipe, less than one-thirty-second of an inch thick,

and adhering very tightly to the surface. By removing this rust with

a sharp instrument it was found that the galvanizing was as clear and

bright as when originally put on.

[Illustration: FIG. 27.--SIMPLE METHOD OF SUPPORTING BRINE PIPES.]

=Cellar Ceiling Suspension.=--In Fig. 27 is shown a very simple,

inexpensive and effective method of supporting brine pipes in cold

storage rooms, or in rooms used as curing cellars, etc. This arranges a

combination whereby a drip pan can be suspended for catching the drip,

the construction being illustrated. It is preferable to line the pans

with galvanized iron so as to preclude possibilities of leakage. The

wooden construction of the ordinary class is usual.

=Ratio of Piping.=--Regarding the quantity of pipe required, this in a

measure depends upon the insulation of the cellars and the temperature

of brine circulated. With brine at a temperature of 10° F., one lineal

foot of pipe will supply radiation sufficient for twenty cubic feet of

cellar.

[Illustration: FIG. 28.--GARDNER’S “CURTAIN” SYSTEM FOR BRINE

CIRCULATION AS INSTALLED IN A CHICAGO PACKING HOUSE.]

=Length of Coil.=--The inlet and outlet pipe should have a 1¹⁄₄-inch

connection, this being ample for a coil about four hundred feet in

length.

=Defrosting.=--To dispose of the accumulation of frost that collects

on the coils within the coil bunkers over the beef and hog coolers, it

is usual to have a warm brine arrangement consisting of an independent

feed header, cross connections to the coils, a tank containing a

heating coil and a small pump.

When the frost collects so as to be detrimental, a supply of brine

in the small storage tank is heated to about 60° F., and it is

continuously pumped through the small auxiliary header, thence into

the coil it is desired to remove the frost from, until the frost is

loosened, when it is lightly tapped and falls to the floor of the

bunker pan. Unless the cellar temperatures are carried low it is

unnecessary to use this system in the curing cellars, as the coils will

drip from natural melting.

The use of this system of brine installation with a proper defrosting

arrangement has much to recommend it as to economy and efficiency,

particularly in use with a balanced brine system.

=Later Practice.=--A better system superseding that just described is

to arrange the coil loft or cooler coils with a brine drip over them

to remove the frost, the drip being collected in the pan, conducted to

a reservoir and re-circulated. Similar to the manner used with direct

expansion piping.

=Gardner Curtain System.=--One of the early types of open brine

chilling was the Gardner curtain system.

For this system a refrigerator or curtain room is provided, directly

above the meat coolers, and of same length and width, in which is fixed

an open pan or brine distributing trough, located over the sheets and

distributing the brine thereon. Fig. 28 shows a photograph of the

curtains in a refrigerator or bunker room.

A plan of installation showing position of curtains is given in Fig.

29, and Fig. 30 shows a cross section of a bunker room with the

arrangement and insulation in a wood constructed building.

=Direct Expansion Piping.=--There is a decided opinion among many

operators that direct expansion ammonia system piping, is preferable

over any brine circulation system, owing to the non-requirement of

pumps for circulating purposes. Caution is necessary in erecting

all direct expansion piping. It must be amply and securely erected,

avoiding the use of coach-screws or lag-bolts, owing to the danger of

rotting and giving away, thus causing perhaps fatal injuries. Room

piping will appear best situated when grouped over alleys and arranged

with drip pans so located as to avoid drip onto meats or packages.

The ratio of piping given for brine pipe will hold as to lineal feet,

substituting foot for foot of two-inch instead of three-inch pipe.

[Illustration: FIG. 29.--PLAN OF GARDNER “CURTAIN” SYSTEM OF

REFRIGERATION.]

=Chill-Room Bunkers.=--In chill-room bunkers there should be a brine

system arranged to drip the brine over the pipes for use during the

early hours of filling, since a double advantage can be gained by so

doing. This is quite effective when intelligently operated.

=Freezer and Storage Buildings.=--The use of freezer buildings have

become of such consequence in larger packing plants for the storage

of meats that it would seem opportune to introduce a description of a

freezer storage building and to discuss the requirements necessary for

it.

[Illustration: FIG. 30.--CROSS SECTION COOLER, BUNKER “CURTAIN” SYSTEM.]

_Growth._--The growth to include as it now does, in most instances,

a produce merchandising business with its seasons of production and

storage together with the necessity of providing low temperature

storage space for storing delicately cured hams and bacon over seasons,

make it almost a necessity to provide low temperature storage or seek

it away from the premises, with the incident expense involved in

transfer and return, storage charges, and the damage resultant from

exposure.

_Location._--A first consideration is the location of the building for

operating advantages, which is a local matter, but involves shipping

facilities by team and by car, convenience to the source of production,

and power plant. Naturally the value of the commodity in storage, which

at present prices, reaches a considerable amount, and the safety of the

product becomes a matter of no small thought.

_Permanence._--The permanence of a building for this purpose once

constructed, and the likelihood of changes due to variation in

business being small, together with the safety of its contents and a

consequent low insurance rate, makes fire-proof cold storage buildings

highly desirable. In these days of increasing insurance rates,

buildings that are rated from twenty to thirty cents per thousand

dollars--non-sprinkled--appeal to us. These rates are not uncommon.

Such can be obtained on properly constructed buildings with adequate

exposure protection.

_Concrete or Steel Frames._--Fire-proof cold storage buildings can be

of various styles of construction. The two types mostly used being,

first, of steel frame with either cast iron or steel columns, girders

and beams with tile or concrete in combination for floors, or secondly,

reinforced concrete frame with concrete and tile in combination, or

monolithic concrete floors.

For moderate heights the walls can be self-sustaining, that is, built

up solidly; but beyond a certain height it becomes economical to use

curtain walls similar to the well known “skyscraper.” In buildings up

to eight stories, reinforced concrete frame with monolithic floors

prove more economical than steel frame with tile or concrete floors.

Reinforced concrete buildings are more lasting, since it is impossible

to closely fit tile around steel columns and girders and exclude air,

moisture, heat and condensation, existing in this class of building,

conditions most contributing to rust. The life of steel framing under

these conditions is an untried experiment. On the other hand, in the

reinforced concrete building the strength is much derived from the

concrete and when well designed and the work well executed the steel

is imbedded and thoroughly concealed in the concrete, remote from the

conditions above stated and contributing to an indefinitely long

life. However, steel columns and girders encased in concrete make them

practically the same.

_Limit for Economic Concrete Columns._--Eight-story warehouses with

basement appear to be ample in height for ordinary conditions. Meeting

the insistent demands of building ordinances in some cities like

Chicago, these can be constructed of reinforced concrete with a maximum

column diameter of twenty-eight inches, with all floors designed for

200 pounds per square foot. This height of building with such loadings

approximates the practical limit of sustaining on footings on the usual

underlying earth, with building panels sixteen feet square, the column

spacing best adapted to storage purposes.

_Types of Construction._--In concrete buildings just referred to, our

preference in style of construction is either of the mushroom type,

that is, flat ceilings without girders; or secondly, with girders

extending in one direction only. An inexperienced engineer in his

efforts to minimize the quantity of steel and concrete requirement will

invariably wish to carry girders from column to column and cross beams

between girders, making the ceiling look like a checkerboard, losing

perhaps twenty inches or more head room on every story and making a

much more expensive building to construct and operate. The same fault

is noticeable in steel frame buildings, since nearly always there are

cross beams between girders. This drops the chilling pipes, curtailing

head room and makes an unsatisfactory arrangement. Whereas with a

mushroom or flat ceiling with girders in one direction, the difficulty

is overcome.

_Space Losses; Beams Two Directions._--In an eight-story building the

additional height above referred to amounts to from ten to fifteen feet

of unnecessary building and adds greatly to the construction cost.

=Exterior Walls.=--As for the exterior surface of the building, this

should be brick, the lighter the color the better, making absorption

of heat less probable. When building reinforced concrete frame with

curtain walls, the design should be such that the brick work entirely

covers the concrete frame, since it is very difficult to obtain tight

joints abutting beams and columns when attempting to build panels of

brick in concrete framing. It is desirable to prevent air and moisture

leakage.

[Illustration: FIG. 31.--GROUND PLAN OF A FREEZER AND STORAGE

BUILDING.]

_Qualities in Brick._--In the selection of brick sufficient attention

is rarely paid to the obtaining of brick burned approximately to

vitrification. The presence of salt, as is frequently noticed on

exterior walls of packing houses adjacent to floor lines, indicates

that brine has been percolating the walls, due to their porosity.

In the same manner water will pass through the opposite direction,

and very far disqualify the insulation materials unless they be

non-absorbing, and even these are lessened in value owing to the

accumulating moisture.

_Wall Construction._--All kinds of tile and plaster or concrete

exteriors should be avoided, since it is impossible to prevent

shrinkage cracks which permit percolation of water, eventually shelling

off plastered surfaces and deteriorating insulation.

_Ventilation._--In northern climates it is desirable to take advantage

of the winter air when it equals or is lower in temperature than

the rooms where product is stored, or when empty to air and cleanse

an apartment. For convenience in this it is advisable to locate

refrigerator windows in the same line to permit ready flow through the

room; these being put on hinges similar to a door.

_Insulation._--When undertaking to construct buildings fire proof,

problems in insulation are encountered. The more dense or heavier the

material used in building, the more cold radiated from all surfaces

unless effectually cut off. In ordinary type of construction the

various floors rest on exterior walls and in no way is it possible to

prevent a very great loss of cold being carried through the floors,

thence to the walls and dissipated thereby. Such matters are not

trivial in their importance. At one wholesale distributing market

deterioration in insulation during six or seven years has necessitated

the doubling of refrigerating machine service and the volume of

business is practically the same. To obviate this the remedy seems

to be to surround the building on all sides and cover the roof with

an encasing of insulation, putting an exterior covering of brick or

impervious material over this to protect the insulation, and to

prevent moisture coming in contact with the insulation. It is just like

dropping a small box within a larger one, the space between the sides

being the insulation.

_Double Posts or Walls._--This is accomplished when building self

sustaining walls by constructing a set of columns adjacent to the walls

with girders from column to column and supporting floor slabs upon

the girders, not permitting either columns, girders or slab to be in

contact with the exterior wall. In a skeleton construction design there

are twin columns, girders and beams, the inner set carrying the floor

loading and the outer the building walls, the insulation lining being

unbroken between them.

_Varying Temperatures._--Commercial demands require a variety of

temperatures, some at zero, some at fifteen degrees and some at

thirty-two or over, in the one building. The maintaining of these

varying temperatures in one building requires most careful designing,

since the concrete everlastingly conveys cold and attempts to cut off a

floor from that above can only be done by comprehensive and extravagant

insulating.

There have been storage houses where with a freezer situated over or

under an egg room a stove was maintained in the egg room to offset the

cold temperature from above or below. A dangerous, costly expedient

as well as the risk of freezing eggs. To encase and isolate a room to

maintain zero to fifteen degrees in it and, say, thirty-two above, it

is necessary to perform the following insulating: Line the ceiling and

beams; cover the floor; cover the columns, so as to really envelop the

cold. When insulation is placed on the floor, naturally the question

of a wearing surface over the insulation is apparent and to maintain

it fire-proof this must be cement or perhaps mastic. This causes an

expenditure for wearing surface over the floor insulation, increased

column quantity and strength, increased deadload of floors, insulation

of floor and ceiling, of columns, and this, conservatively speaking,

amounts to a total of eighty-five to ninety cents per square foot of

area. This over one foot is but a small amount, but on a building one

hundred feet square it becomes eighty-five hundred dollars per story.

_How to Sub-divide._--To meet the variety of temperatures required,

subdividing the premises into sections, but doing it vertically rather

than attempt to divide it horizontally, with a portion set aside for

each division of temperature. If the business is of such volume as to

permit this, make no attempt to insulate one floor from that above,

as there is no practical way to do it and obviate an investment in

insulation from which there is no return. A thorough external wall

and roof insulation is strongly recommended, and the cold radiating

into a room above that may be only partially filled or empty may be

considered as no great loss, provided the outer contacts are eliminated

or minimized.

In fire-proof construction the loss of cold through the ground is

an unsolvable problem. To effectually do so it would be required to

insulate every floor slab, top and bottom, all wall beam and column

surfaces. From the foregoing deduction the cost would be prohibitive.

_Basement Freezers._--It is obvious from this argument that freezers

should not be located in basements. It is far better to locate them

on the upper floors of the buildings and make the cellar a moderately

cold room, permitting the cold that will to radiate from the columns

to chill it, but supplying such additional piping as may be required

to maintain a regular temperature. If a freezer is placed on a first

floor, it requires insulating the basement ceiling, which can be

readily done. The basement columns are not insulated.

_Piping Systems._--With reference to piping for freezing boxed goods

or beef cuts, the shelving system made from coils of pipe upon which

to store the product while freezing is preferable. They are equally

efficacious, whether used in brine circulation or direct expansion

of ammonia. The coils in the freezing rooms are located on ceilings,

making one layer over ceiling for fifteen-degree rooms where conditions

permit, for handiness in removing frost. If the rooms be carried at

thirty-two degrees or over, group the coils in alleys to enable easy

location of pans for collecting drip, when coils are out of service.

Whether one uses direct refrigerating by expansion of ammonia or brine

circulation through pipes hung in rooms or indirect refrigerating by

circulation of chilled air is a matter governed by local conditions and

requirements.

[Illustration: FIG. 32.--LONGITUDINAL SECTION OF A FREEZER AND STORAGE

ROOM.]

_Area and Division._--The plant shown in Figs. 31, 32 and 33 has a

large ground area and is a non-sprinkled risk. This building has a

frontage of 230 feet by 130 feet depth. To avoid an insurance area

charge for too large floor areas, and because of a desire to carry

several temperatures, the building was subdivided into three sections,

A, B and C, by putting in fire walls. It was designed to have Section

“C” subdivided into two halves, permitting the maintenance of two

classes of low temperature. Section “B” was set aside primarily for

carrying eggs and apples and thoroughly isolated. Section “A” was

treated in like manner to Section “C,” except that provision was made

for the division wall, which was not put in at time of construction.

Illustrating the design is a general floor plan of the premises

together with a longitudinal section drawing and a cross section

drawing of Section “C.”

[Illustration: FIG. 33.--TRANSVERSE SECTION THROUGH FREEZER SECTION

“C.”]

_Receiving and Discharging._--Referring to the plan, attention is

drawn to the three sections. Ingress and egress have been provided

by railroad track at one end of Section “A” and double track with

platforms on each side connected at end. Twin elevators with stairs are

located within a continuous vestibule and the center section can be

served from either elevator and stairs in either vestibule. The corner

stairs in Sections “A” and “B” were demanded by the City Building

Department, but not necessary to the operation of the plant.

_Insulation Lines._--Referring to the longitudinal section observe the

twin columns, twin girders on each floor level, the inner carrying the

floor construction and the outer the curtain walls. Notice the inlay

of insulation. The outer walls entirely enclose the concrete skeleton,

making the brick work continuous and sightly.

The transverse drawing of Section “C” shows a partition continuous from

basement to ceiling of sixth floor. This partition is not built from

floor to floor, but continuous through the floors, making either end

virtually an isolated building.

_Warm Storage--One Floor._--It was desirable in this instance to use

the upper floors of the building for warm storage, consequently the

top encasing insulation is placed on the ceiling of the sixth story,

continuing to and meeting the wall insulation, which with the wall

insulation encases the cold storage, as spoken of for the ideal. The

floor construction is of flat ceiling type, there being no girders to

contend with in piling product or installing piping.

_Part Freezers._--Frequently the space required for freezing purposes

will not be sufficient to justify the construction of an independent

building. Sometimes consideration is given to building freezers in a

horizontal belt, horizontally across the building. This is not a proper

construction, since it costs much more to insulate than if the same

volume were arranged vertically with one section above the other. In

other words, if one desires to cover a floor surface of 20,000 square

feet it would be far better to make it four areas of 5,000 feet in a

four-story building than on one or two floors.