CHAPTER VIII

WIRING THE HOUSE

The insurance code--Different kinds of wiring described--Wooden

moulding cheap and effective--The distributing panel--Branch

circuits--Protecting the circuits--The use of porcelain tubes and

other insulating devices--Putting up chandeliers and wall

brackets--"Multiple" connections--How to connect a wall

switch--Special wiring required for heat and power circuits--Knob

and cleat wiring, its advantages and drawbacks.

The task of wiring your house is a simple one, with well-defined rules

prescribed by your insurance company. Electricity, properly installed,

is much safer than oil lamps--so much so indeed that insurance

companies are ready to quote especial rates. But they require that the

wiring be done in accordance with rules laid down by their experts,

who form a powerful organization known as the National Board of Fire

Underwriters. Ask your insurance agent for a copy of the code rules.

Danger of fire from an electric current comes from the "short

circuit," partial or complete; and it is against this danger that the

rules guard one. The amount of electricity flowing through a short

circuit is limited only by the fuse protecting that line; and since

there is no substance known that can withstand the heat of the

electric arc, short circuits must be guarded against. Happily the

current is so easily controlled that the fire hazard is eliminated

entirely--something which cannot be done with oil lamps.

In house-wiring for farm plants, the wire should be rubber-covered,

and not smaller than No. 14 B. & S. gauge. This is the wire to use on

all lamp circuits. It costs about $0.85 cents per 100 feet. There are

four kinds of wiring permitted, under the insurance code:

(1) _Flexible armoured cable_: This consists of two-wire cable,

protected with a covering of flexible steel. It is installed out of

sight between the walls, and provides suitable outlets for lamps,

etc., by means of metal boxes set flush with the plaster. It is

easily installed in a house being built, but requires much tearing

down of plaster for an old house. Since its expense prohibits it in

the average farm house, this system will not be described in detail

here.

(2) _Rigid and flexible conduit_: As the name implies this system

consists of iron pipe, in connection with flexible conduit, run

between the walls. It differs from the above system, in that the pipes

with their fittings and outlet boxes are installed first, and the

wires are then "fished" through them. Duplex wires--the two wires of

the circuit woven in one braid--are used; and a liberal amount of

soapstone, and occasionally kerosene, are used to make the wires slip

easily into place. This is the most expensive system, and the best;

but it is difficult to install it in an old house without tearing down

a good deal of plaster. It has the advantage of being absolutely

waterproof and fireproof.

(3) _Wooden moulding_: This is simply moulding, providing two

raceways for the insulated wires to run in, and covered with a

capping. It is nailed or screwed firmly to the wall, on top of the

plaster; and when the wires have been installed in their respective

slots and the capping tacked on, the moulding is given a coat of paint

to make it in harmony with the other moulding in the room. This system

is cheap, safe, and easily installed, and will be described in detail

here.

[Illustration: Detail of wooden moulding]

(4) _Open wiring_: In open wiring, the wires are stretched from one

support to another (such as beams) and held by means of porcelain

cleats, or knobs. It is the simplest to install; but it has the

objection of leaving the wires unprotected, and is ugly. It is very

satisfactory in barns or out-buildings however.

_The Distributing Panel_

The first point to consider in wiring a house with wooden moulding is

the distribution board. It should be located centrally, on the wall

near the ceiling, so as to be out of ordinary reach. It consists of a

panel of wood--though fireproof material is better--firmly screwed to

the wall, and containing in a row, the porcelain cut-outs, as shown in

the cut, from which the various branch circuits are to be led. Each

cut-out provides for two branch circuits; and each branch contains

receptacles for two plug fuses. These fuses should be of 6 amperes

each. The Insurance Code limits the amount of electricity that may be

drawn on any branch lamp circuit to 660 watts; and these fuses protect

the circuit from drafts beyond this amount.

[Illustration: Porcelain cut-out and plug fuse]

The mains, leading from the entrance switch, as shown in the diagram,

to the panel board, should be of the same size as the transmission

wire itself, and rubber-covered. These mains terminate at the

distributing board. They are connected to the terminals of the

cut-outs by means of heavy brass screws.

_Wire Joints_

[Illustration: Examples of cleat and knob wiring, 1, 2, 3; wire

joints, 4; flexible armoured conductor, 5]

The branch circuits are, as has been said, of No. 14 rubber-covered

wire, running concealed in wooden moulding. All joints or splices in

this wire are made, as shown in the illustration, by first scraping

the wires bright, and fastening them stoutly together. This joint is

then soldered, to make the connection electrically perfect. Soft

solder is used, with ordinary soldering salts. There are several

compounds on the market, consisting of soft solder in powder form,

ready-mixed with flux. Coat the wire joint with this paste and apply

the flame of an alcohol lamp. The soldered joint is then covered with

rubber tape, and over this ordinary friction tape is wound on. A neat

joint should not be larger than the diameter of the wire before

insulation is removed.

_Branch Circuits_

First, make a diagram of your rooms and indicate where you wish lamps,

or outlets for other purposes. Since wooden moulding can be run across

ceilings, and up or down walls, lamps may be located in places where

they are out of the way. In planning the circuit, remember that you

will want many outlets in handy places on the walls, from which

portable cords will convey current to table lamps, to electric irons

and toasters and other handy devices which can be used on the lamp

circuit. These outlets are made of porcelain, in two pieces. One

piece is merely a continuation of the moulding itself; and the other

is a cap to connect permanently to the end of the lamp or iron cord,

which may be snapped into place in a second. Since there are a great

many designs of separable current taps on the market, it is well to

select one design and stick to it throughout the house, so that any

device can be connected to any outlet.

The code permits 660 watts on each circuit. This would allow 12 lamps

of 55 watts each. It is well to limit any one circuit to 6 lamps; this

will give leeway for the use of small stoves, irons, toasters, etc.

without overloading the circuit and causing a fuse to blow.

Having installed your distributing board, with its cut-outs, figure

out the course of your first branch circuit. Let us say it will

provide lights and outlets for the dining room and living room. It

will be necessary to run the wires through the partitions or floors in

several places. For this purpose porcelain tubes should be used,

costing one to three cents each. Knock holes in the plaster at the

determined point, insert the tubes so they project 3/4 inch on each

side, and fill up the ragged edge of the hole neatly with plaster.

[Illustration: The distributing panel]

When all the tubes have been set in place, begin laying the moulding.

Run it in a straight line, on the wall against the ceiling wherever

possible, mitering the joints neatly. Whenever it is necessary to

change the run from the ceiling to the wall and a miter cannot be

made, the wires should be protected in passing from one slot to the

other by being enclosed in non-metallic flexible conduit, called

circular loom.

In running wooden moulding, avoid brick walls liable to sweat or draw

dampness; keep away from places where the heat of a stove might

destroy the rubber insulation of the wires; do not pass nearer than

six inches to water pipes when possible--and when it is necessary to

pass nearer than this, the wooden moulding should pass above the pipe,

not below it, with at least an inch of air space intervening, thus

avoiding dampness from sweating of pipes.

[Illustration: Snap switch connections]

Places where chandeliers or wall bracket lamps are to be installed

permanently are fitted with wooden terminal blocks, which fit over

the moulding and flush with the plaster. These, after holes have been

bored in them for the wires, and the wires drawn through, should be

screwed firmly to the wall or ceiling, always choosing a joist or beam

for support. Then a crow's-foot, or tripod of iron, tapped and

threaded for iron pipe, is screwed to the terminal block. The iron

pipe of the chandelier or wall bracket is then screwed home in this

crow's-foot.

Do not begin stringing wires until all the moulding of the circuit has

been laid. Then thread the wires through the wall or floor tubes and

lay them in their respective slots. If trouble be found making them

stay in place before the capping is put on, small tacks may be driven

into the moulding beside them to hold them. When a terminal block is

reached, a loop is made of each wire, through the hole cut in the

block, if the circuit is to continue in the same direction. If it is

to end there, the two wires are drawn through taut, and cut off at a

length of 5 or 6 inches. These end wires, or loops, are then scraped

bare and spliced to the two wires coming out of the chandelier or

wall bracket. This joint is then soldered and covered with tape, and

the shell of the chandelier is screwed into place, covering the joint.

[Illustration: Detail of wooden moulding]

If the moulding is run along the walls flush with the ceiling, as is

usual, a branch is made for a wall light, or wall tap, by means of a

porcelain "T," or branch-block, which provides the means for running

the circuit at right angles to itself without letting the wires come

in contact with each other where they cross. Separable current taps

should be installed in handy places on all circuits, so that small

heating devices may be used without removing the lamps from their

sockets. The two wires are bared for half an inch where they run

through these current taps, and are fastened by means of brass screws.

_"Multiple" Connections_

All electric devices for this installation--lamps, irons, vacuum

cleaners, motors--must be connected _across_ the circuit--that is,

bridged, from one wire to the other. This is called _multiple_, or

shunt connection. There is only one exception to it, in wiring the

house. That one exception is installing a wall switch, the ordinary

snap switch. Since this wall switch, is, in effect, merely an

instrument, which opens or closes a circuit, it should be connected to

only one wire, which is cut to provide two ends for the screw

connections in the switch. When a moulding branch is run down from the

ceiling to some convenient spot for a snap switch (with which to turn

the lights of a room on or off), a porcelain "T" is not used. All that

is necessary to do is to loop the bottom wire of the circuit down

through the branch moulding, and connect it to the switch at a

terminal block, or porcelain base.

In wiring lamp fixtures, No. 14 rubber-covered wire will usually prove

too large. For this purpose, No. 18 may be used, with one lamp to each

loop. Hanging lamps may not be supported by electric lamp cord itself,

if there is more than one lamp in the cluster, because the weight is

apt to break the electrical connections. In such a case, the lamp

should be supported by a chain, and the twisted cord conveying current

to the electric bulbs, is woven in the links of the chain. For the

pantry, kitchen, woodshed, barn, etc., a single hanging lamp may be

suspended from a fielding rosette, as shown in the cut, provided a

single knot is tied inside both the rosette and the lamp socket, to

make it secure. This makes a very cheap fixture. The rosette of

porcelain will cost 15 cents; the lamp socket 20 cents, and the lamp

cord suspending the lamp and carrying the current will cost 1-1/2

cents a foot; while a tin shade will cost another 15 cents.

[Illustration: Detail of simple hanging lamp supported by rosette]

_Official Inspection_

In all communities, your insurance agent must inspect and pass your

wiring before you are permitted to throw the main switch and turn on

the electricity. Frequently they require that the moulding be left

uncapped, until they have inspected it. If you have more than 660

watts in lamps to a circuit; if your joints are not soldered and well

taped; if the moulding is used in any concealed or damp place, the

agent is liable to condemn your work and refuse permission to turn on

the electricity. However the rules are so clearly defined that it is

difficult to go wrong; and a farmer who does his own wiring and takes

pride in its appearance is more apt to be right than a professional

electrician who is careless at his task. After the work has been

passed, tack on the moulding capping, with brads, and paint the

moulding to match the woodwork.

Wooden moulding wiring is perfectly satisfactory if properly

installed. It is forbidden in many large cities, because of the

liability of careless workmanship. It should never be installed in

damp places, or out of sight. If the work is well done, the system

leaves nothing to be desired; and it has the additional advantage of

being cheap, and easily done by any farmer who can use carpenter

tools. Farmers with moulding machinery can make their own moulding.

The code prescribes it shall be of straight-grained wood; that the

raceways for the wires shall be separated by a tongue of wood one-half

inch wide; and that the backing shall be at least 3/8 inch thick. It

must be covered, inside and out, with at least two coats of

moisture-repellant paint. It can be had ready-made for about 2 cents a

foot.

_Special Heating Circuits_

If one plans using electricity for heavy-duty stoves, such as ranges

and radiators, it is necessary to install a separate heating circuit.

This is the best procedure in any event, even when the devices are all

small and suited to lamp circuits. The wire used can be determined by

referring to the table for carrying capacity, under the column headed

"rubber-covered." A stove or range drawing 40 amperes, would require a

No. 4 wire, in moulding. A good plan is to run the heating circuit

through the basement, attaching it to the rafters by means of

porcelain knobs. Branches can then be run up through the floor to

places where outlets are desired. Such a branch circuit should carry

fuses suitable to the allowed carrying capacity of the wire.

_Knob and Cleat Wiring_

Knob and cleat wiring, such as is used extensively for barns and

out-buildings, requires little explanation. The wires should not be

closer than 2-1/2 inches in open places, and a wider space is better.

The wires should be drawn taut, and supported by cleats or knobs at

least every four feet. In case of branch circuits, one wire must be

protected from the other it passes by means of a porcelain tube. It

should never be used in damp places, and should be kept clear of dust

and litter, and protected from abrasion.

[Illustration: Knob and cleat wiring]

Knob and tube wiring is frequently used in houses, being concealed

between walls or flooring. In this case, the separate wires are

stretched on adjoining beams or rafters, and porcelain tubes are used,

in passing through cross beams. For a ceiling or wall outlet, a

spliced branch is passed through the plaster by means of porcelain

tubes or flexible loom.

Wires from the house to the barn should be uniform with transmission

wires. At the point of entry to buildings they must be at least six

inches apart, and must take the form of the "drop loop" as shown in

the illustration. A double-pole entrance switch must be provided,

opening downward, with a double-pole fuse. In passing over buildings

wires must not come closer than 7 feet to flat roofs, or one foot to a

ridge roof. Feed-wires for electric motors should be determined from

the table of safe carrying capacities, and should be of liberal size.