CHAPTER III

HOW THE SKI-OPTOMETER ASSISTS IN REFRACTION

The construction of the Ski-optometer has now been fully explained, and

the reader realizes that since the instrument contains all the lenses

necessary in making an examination, greater operative facility is

afforded through its use than where the trial-case lenses are employed.

The Ski-optometer is “an automatic trial-case” in the broadest sense

of the term, wholly superseding the conventional trial-case. It should

therefore be employed throughout an entire examination, wherever

trial-case lenses were formerly used. To fully realize its labor saving

value in obtaining accurate examination results, it is only necessary

to recall the tedious method of individually handling and transferring

each lens from the trial-case to the trial-frame, watching the stamped

number on each lens handle, wiping each lens and in the case of

cylindrical lenses setting each one at a designated axis—all being

needless steps where the Ski-optometer is employed.

THE USE OF THE SKI-OPTOMETER IN SKIOSCOPY

In skioscopy, the Ski-optometer offers the refractionist assistance of

the most valuable character.

For example, assuming that extreme motion in the opposite direction

with plane or concave mirror is obtained with a +1.25D. spherical

lens before the patient’s eye; by quickly turning the Ski-optometer’s

single reel until the two white zeros again appear, +2.50D is secured,

as explained in the previous chapter. If this continues to give too

much “against motion,” the lens power should be quickly increased to

+3.75 or +5.00D if necessary (Fig. 4). Should the latter reveal a

shadow in the reversed direction, the refractionist is assured that it

is the weakest lens that will cause its neutralization. Practically

but few lenses have been used to obtain the final result proving

the instrument’s importance and time-saving value in skioscopy, and

demonstrating the simplicity with which tedious transference of

trial-case lenses is avoided.

Furthermore, it should be noted that where the Ski-optometer is used

in skioscopy, it is not necessary to remove the retinoscope from the

eye or to constantly locate a new reflex with each lens change. This

permits a direct comparison of the final lens and eliminates the usual

difficulty in mastering skioscopy. The chief cause of this difficulty

is due to the fact that the transferring of the trial-case lenses makes

it practically impossible for the student to determine whether the

previous lens caused more “with” or “against” motion.

[Illustration: Fig. 9—The Woolf ophthalmic bracket. A convenient and

portable accessory in skioscopy and muscle testing; can be used with or

without Greek cross.]

Where the indirect method is employed in skioscopy, best results

are secured through the use of the Woolf ophthalmic bracket and

concentrated filament lamp, together with an iris diaphragm chimney.

The latter permits the reduction or increase of the amount of light

entering the eye, as it is agreed that a large pupil requires _less_

light, a small pupil requiring _more_ light. The bracket referred to

permits the operator to swing the light into any desired position

(Fig. 9), while the iris diaphragm chimney serves as a shutter. This

apparatus may also be employed for muscle testing, as described in a

subsequent paragraph.

A SIMPLIFIED SKIOSCOPIC METHOD

In using the Ski-optometer, instead of working forty inches away from

the patient in skioscopy and deducting 1.D., the refractionist will

find it more convenient to work at a twenty inch distance, deducting

2.D. This working distance may be accurately measured and maintained by

using the reading rod accompanying the instrument. Instead of deducting

2.D. from the total findings, however, it is preferable to insert a

+2.D. trial-case lens in the rear cell of the instrument directly next

to the patient’s eye. After determining the weakest lens required to

neutralize the shadow in both meridians, the additional +2.D. lens

should be removed and the total result of the examination read from the

instrument’s register.

To illustrate a case in skioscopy where spherical lenses are employed

to correct both meridians, assume that the vertical shadow requires

a +1.25D lens to cause its reversal, while the horizontal requires

+2.00D. Employment of the customary diagram, illustrated in Fig. 10,

would show the patient required +1.25 sph. = +.75 cyl. axis 90°, which

when transposed is equivalent to +2.00 sph. = -.75 cyl. axis 180°.

[Illustration: Fig. 10—Where spherical lenses are employed in

skioscopy, above indicates patient requires]

+1.25 Sph. = +.75 Cyl. Axis 90°

or +2 Sph. = -.75 Cyl. Axis 180°

It should be noted that the total spherical power is +2.00D, as the

Ski-optometer’s register shows, while the difference between the two

meridians is 75, which is the required strength of the cylinder. By

then turning the cylinder reel to .75, and setting the axis indicator

at 180° (because by using minus cylinders, the axis must be reversed)

the patient should read the test-type with ease if the skioscopic

findings are correct. Thus with the Ski-optometer, it is not even

necessary to learn transposition, since the instrument automatically

accomplishes the work, avoiding all possibility of error.

EMPLOYING SPHERES AND CYLINDERS IN SKIOSCOPY

Another commonly used objective method may be employed with even

greater facility through the combined use of both the Ski-optometer’s

spherical and cylindrical lenses. As previously suggested, insert the

+2.00 spherical trial-case lens in the rear of the instrument, working

at a twenty inch distance, then proceed to correct the strongest

meridian first.

It was assumed that it required a +2.00 spherical to neutralize

the strongest, or horizontal meridian, as shown in Fig. 10. The

refractionist should then set the axis indicator therewith, which is

the axis of the cylinder, or 180°.

It is then merely a matter of increasing the Ski-optometer’s

cylindrical lens power until the reversal of the shadow in the weakest

meridian is determined. Assuming this proves to be -.75 cylinder, axis

180°, the patient’s complete prescription +2.00 sph. = -.75 cyl. axis

180°, would be registered in the Ski-optometer without any further lens

change other than the removal of the +2.00 working distance lens.

However, regardless of the method employed, the Ski-optometer greatly

simplifies skioscopy. In fact, the instrument was originally intended

to simplify retinoscopy or skioscopy, as the subject should be termed,

the name “Ski-optometer” having been derived from the latter.

USE OF THE SKI-OPTOMETER IN SUBJECTIVE TESTING

In subjective refraction, especially where the “better or worse”

query must be decided by the patient, it is commonly understood that

the refractionist is compelled to first increase and then decrease

a quarter of a diopter before the final lens is decided. With the

Ski-optometer, the usual three final changes are made in far less

time than it takes to make even _one_ lens change from trial-case to

trial-frame.

For example:

Assuming, with a +1.25D spherical lens before the patient’s right

eye, he remarks that he “sees better” with a +1.D. while +.75D is not

as satisfactory. The refractionist can then quickly return to +1.D.,

simply turning the Ski-optometer’s single reel _outward_ to increase,

or _backward_ to decrease, the lens strength. So rapidly have these

lens changes been made, that the patient quickly sees the difference of

even a _quarter_ diopter, and quickly replies, “better” or “worse.”

This is made possible because the eye does not “accommodate” as quickly

as the lens change made with the Ski-optometer. It should also be noted

that the eye receives an image on its retina within one-sixteenth of

a second; otherwise, the patient is forced to accommodate, making it

difficult to see the difference of even a quarter diopter. On the

other hand, in transferring trial-case lenses, with its slow, tedious

procedure, the patient, being unable to detect the slight difference of

only a quarter diopter, unhesitatingly replies, “no difference,” merely

because they are compelled _to accommodate_.

A SIMPLIFIED SUBJECTIVE METHOD

The following simplified method of procedure is suggested for

subjective testing with the Ski-optometer, although as previously

explained, the refractionist may employ his customary method,

overcoming the annoyance of transferring trial-case lenses and the

setting of each cylinder individually. The Ski-optometer has been

constructed and based upon the golden rule of refraction: “As much plus

or as little minus spherical, combined with as little minus cylinder

power as the patient accepts.”

By applying this rule as in the above method and starting with +5.D.

spherical, watching the two zeros (Fig. 4) and rapidly reducing +1.25D

each time, we will assume that +1.25D gives 20/30 vision; as a final

result +1.D. will possibly give 20/25 vision.

The patient’s attention should next be directed to the most visible

line of type, preferably concentrating on the letter “E” or the clock

dial chart—either of which will assist in determining any possible

astigmatism. Since the Ski-optometer contains concave cylinders

exclusively, the next move should be the setting of its axis indicator

at 180°, commonly understood as “with the rule.” One should then

proceed to determine the cylinder lens strength by turning the reel

containing the cylindrical lenses (Fig. 8). Should the patient’s vision

fail to improve after the -.50D. cylinder axis 180° has been employed,

the refractionist, in seeking an improvement, should then slowly move

the axis indicator through its entire arc.

With the cylinder added, regardless of axis, poor vision might indicate

the absence of astigmatism. If astigmatism exists, vision will usually

show signs of improvement at some point, indicating the approximate

axis. Once the latter is ascertained, the refractionist may readily

turn the Ski-optometer’s cylinder reel and obtain the correct cylinder

lens strength, after which the axis indicator should be moved in either

direction in order to obtain the best possible vision for the patient.

The refractionist should always aim to obtain normal (or 20/20) vision

with the weakest concave cylinder, combined with the strongest plus

sphere, or weakest minus sphere.

PROCEDURE FOR USING MINUS CYLINDERS EXCLUSIVELY

For the benefit of those who have never used minus cylinders

exclusively in making their examinations, we will assume that the

patient requires O.U. +1.D sph. = -1D cyl. axis 180° for final

correction; the latter, in its transposed form, being equivalent to

+1.D. cylinder axis 90°. Unquestionably the best method is the one that

requires the least number of lens changes to secure the final result.

To obtain this, the following order of lens change should be made:

First, +1.D. sphere is finally determined and allowed to remain in

place. Concave cylinders are then employed in quarters until the final

results of +1.D. spherical, combined with -1.D. cylinder axis 180° is

secured. This necessitates the change of but _four_ cylindrical lenses

as shown in routine “A” as follows:

ROUTINE “A” ROUTINE “B”

(Made with _minus_ cylinder) (Made with _plus_ cylinder)

Sph. +1.D. Cyl. Axis Sph. +1.D. Cyl. Axis

Step 1 +1.D. = -.25 ax. 180° equal to +.75 = +.25 ax. 90°

Step 2 +1.D. = -.50 ax. 180° equal to +.50 = +.50 ax. 90°

Step 3 +1.D. = -.75 ax. 180° equal to +.25 = +.75 ax. 90°

Step 4 +1.D. = -1 ax. 180° equal to 0 +1 ax. 90°

In brief the method of using minus cylinders exclusively in an

examination, as explained in routine “A”, necessitates the change of

the cylinder lenses only after the _strongest_ plus sphere is secured.

On the other hand, notwithstanding innumerable other methods where plus

cylinders are used, routine “B” shows that the best spherical lens

strength the patient will accept, is also first determined. Then both

spheres and cylinders are changed in their regular order by gradually

building up in routine, by increasing plus cylinder and next decreasing

sphere, a quarter diopter each time, until the final result is secured.

While it is conceded that both routine “A” and “B” are of themselves

simplified methods, by comparing routine “A” where minus cylinders

are used with routine “B” where plus cylinders are used in their

corresponding steps, the refractionist will note by comparison that

one is the exact equivalent and transposition of the other. Where

_plus_ cylinders are employed, eight lens changes are made before final

results are secured; while but four lens changes are necessary where

_minus_ cylinders are used.

The refractionist should also note by comparison that the use of minus

cylinders reduces focus of the plus sphere, but only in the meridian

of the axis. It has not made the patient myopic. Furthermore, a plus

cylinder will bring the focal rays forward, while minus cylinders throw

them backward toward the retina.

This is but another reason for the exclusive use of minus cylinders in

refraction.

The method of using _minus cylinders_ exclusively in an examination,

necessitates the change of the cylinder lenses _only_. On the other

hand, the method of using plus cylinders makes it necessary to change

spheres and cylinders in routine.

In brief, since using the minus cylinder is merely a matter of

mathematical optics, their use even in a trial-case examination is

strongly urged.

The maximum value of the Ski-optometer is fully realized only when the

advantages of using minus cylinders exclusively in every examination is

clearly understood.

CONSTANT ATTENTION NOT REQUIRED

With the Ski-optometer, when the examination is completed, the

sum-total of final results—whether spherical, cylinder, axis, or all

combined—are automatically indicated or registered ready to write the

prescription. _Until then_, the foci of the various lenses that may be

employed are of no importance.

In short, in using the Ski-optometer, it is not necessary to constantly

watch the registrations during examinations. The automatic operation

of the instrument is an exclusive feature, so that the refractionist

should unhesitatingly employ it. Hence, by eliminating the perpetual

watch on the lenses in use, the refractionist is enabled to give his

undivided attention to the patient rather than to the trial lenses.

Where a special dark-room is used for skioscopic work, an additional

wall bracket or floor stand will necessitate only the removal of

the instrument itself. This enables the refractionist to use the

Ski-optometer for subjective or objective work, without disturbing the

patient’s correction.