CHAPTER III

REQUIREMENTS DURING OPERATION

SPONGES AND SPONGING

Natural or sea sponges are now little used in surgery, owing to their

peculiar cellular construction. They invite and readily retain spores and

germs, are difficult to clean, and require almost constant attention to

be at all safe.

Many methods for rendering these sponges aseptic have been proposed, but

at best the life of such a sponge is short and hardly pays for the labor

and time expended. The absorbing power of a sponge is, of course, its

essential quality. For plastic operations sterilized absorbent cotton

made into small balls answers every purpose. These puffs of cotton are

covered with gauze to prevent the fraying out of the fibers. To further

improve them, their centers may be made up of cellulose or wood fiber.

When an absorbent cotton sponge is moistened and squeezed out it does

not answer as well, since its absorbing qualities are much reduced; the

addition of the other material overcomes this.

A much-used and inexpensive sponge having great absorbing power is made

in the form of a small compress of sterilized gauze held together with

one or two stitches of thread. All of the above sponges are sterilized

with the needed dressings and are burned after use. When removed from the

sterilizer they are placed in a suitable basin containing six per cent

sterilized salt water. It is well to place the receptacle close by the

assistant who is to sponge. An enameled iron basin rack, as shown in

Fig. 12, answers the purpose best.

[Illustration: FIG. 12.—BASINS AND RACK.]

The soiled sponges are thrown into a lower empty basin or one placed

at the operator’s feet. As they are removed from the solution they are

squeezed as dry as possible and pressed upon, rather than wiped across,

the operative field. It must be remembered that the surgeon’s work must

not be hampered by slow or inefficient sponging, and that this procedure

must be quick and timely. It is well for the assistant to become

accustomed to the habit of the operator.

The best assistant is one who has acquired a methodical and regular

manipulation, a result dependent upon constant individual association;

such a one is practically invaluable for the skillful performance of

plastic surgery. He becomes not only familiar with the one thing, but

cultivates a ready knowledge of the arrest of hemorrhage by digital

compression when hemostatic forceps would hinder the ease of work,

besides cultivating a happy manner of holding retractors or spreading the

edges of the incisions with the free hand. As in most of these operations

hemorrhage cannot be controlled by the so-called bloodless method. The

assistant must control the constant oozing by the gentle pressure of the

sponge quickly applied at short intervals. When the sponges are squeezed

out in salt solution, as hot as the hand will bear comfortably, capillary

oozing is more readily overcome.

STERILIZATION OF DRESSINGS

All dressings to be used in covering wounds, _post operatio_, or

otherwise, must be as scrupulously clean and free from infection as the

hands and the instruments of the operator. This is done by means of

sterilization by dry heat or steam under pressure. For all minor cases,

small apparatuses only are needed. They are usually made of copper,

often nickel-plated, and so constructed as to contain a lower perforated

instrument tray and another, placed above it, for dressings. The two

are fitted into an outer copper receptacle with snugly fitting cover. A

folding stand is furnished upon which this arrangement is placed, and an

alcohol lamp with asbestos wick furnishes the heating power. The lower

tray is covered with water which, by boiling, fills the upper compartment

with steam evenly distributed and with sufficient pressure to accomplish

sterilization in from thirty to sixty minutes. Metal hooks are provided

with which the trays can be removed. A complete and compact outfit, as

designed by Willy Meyer, is shown in Fig. 13.

In the above sterilizer, or in those of similar type, there is naturally

more or less saturation of the dressings and the possibility, in the

event of the entire conversion of the water contained therein into steam,

of injuring the instruments by excessive heat. To overcome this defect

the Wallace sterilizer may be advantageously employed.

[Illustration: FIG. 13.—WILLY MEYER STERILIZER.]

[Illustration: FIG. 14.—WALLACE STERILIZER.]

=Wallace Sterilizer.=—Its chief feature is the addition of a reservoir

fitting with the separated sterilizer into the outer body. See Fig. 14.

This reservoir automatically regulates the water and steam supply. It is

filled with water and inserted into the compartment provided for and

adjoining the sterilizer. Through an opening in the bottom the water is

permitted to escape into the sterilizer until the bottom of the latter

is covered to a depth of ⅛ inch. As the heat is applied from the alcohol

lamp this film of water is rapidly converted into steam.

The dressings arranged in the large tray are placed in the sterilizer

and the supply of steam is maintained through the constant and steady

flow of water from the reservoir, which compensates the evaporation in

the sterilizer. In about twenty minutes the formation of steam in the

top of the reservoir exerts sufficient pressure to force all the boiling

water from the reservoir into the sterilizer to the depth of about 1½

inches. The tray of instruments is now inserted and the process continued

for another ten minutes. Much less heat is required with this apparatus

than with those of ordinary type, while sterilization can be continued

uninterruptedly for one and one half hours, if need be.

=Sprague Sterilizer.=—The most perfect sterilizer is that of the Sprague

type, in which a dry chamber is surrounded by steam under pressure. The

apparatus is shown in Fig. 15.

[Illustration: FIG. 15.—SPRAGUE TYPE OF STERILIZER.]

Its cylindrical chamber is surrounded by two heavy copper shells, the

space between which is occupied by the water. This compartment is

entirely shut off from the sterilizing chamber, and as the steam is

generated, the inner, or sterilizing, chamber becomes heated to a degree

nearly equal to that of the steam in the surrounding cylinder; this

prevents any condensation of steam taking place in the dressings. By

opening the lever-handled valve at the bottom of the sterilizer in the

rear, and the valve to the right, on top of the sterilizer, and allowing

them to remain open for a space of four or five minutes, a vacuum is

formed in the sterilizing chamber. These two valves are then closed, the

lower one first, and the steam from the outer cylinder is allowed to

enter the chamber, by opening the left valve on top.

The contents should be allowed to sterilize for twenty or twenty-five

minutes under a pressure of fifteen pounds. Then close the steam-supply

valve; open the vacuum valve (right) and the lever-handled valve at the

bottom; leave these open about the same time as in creating a vacuum at

the beginning of the process; close both valves, then open the air-filter

valve on the door, in order to break the vacuum; the door can then be

opened and the dressings be taken out dry and absolutely sterile.

The steam-safety valve on this sterilizer is set at seventeen pounds, but

it can easily be regulated should a higher or lower pressure be desired.

The door used on this apparatus has no packing of rubber or other soft

material which wears or shrinks in time, a steam-tight joint being

formed by the bringing together of two plane metal faces on the door and

sterilizer head. The door hinge is so made that these parts are bound to

come together properly, without the use of excessive caution. Springs

on such doors are liable to get out of order or need replacing, and are

avoided in this apparatus. All that is necessary to lock or unlock the

door is to turn the large hand wheel on the front; the locking levers

then work automatically. These sterilizers are arranged for both gas and

steam heat.

=Sterilizing Plant.=—For the ideal operating room the entire sterilizing

plant can be had in combined form, as shown in Fig. 16. It consists of

a dry-heat dressing apparatus, just described, water and instrument

sterilizers, all mounted on a white enameled, tubular, wrought-iron

frame. The chamber of the dressing sterilizer is 8½ by 19 inches. The

water sterilizer has a capacity of six gallons in each tank and is

fitted with natural stone filters, thermometer, water gauge, safety

valve, etc. The size of the instrument sterilizer is 8 by 15 inches and

6 inches deep, with two trays. Each apparatus in the above can be used

independently of the other, all being arranged for gas-heating.

[Illustration: FIG. 16.—STERILIZING PLANT.]

=Dressing Cases.=—All dressings should be sterilized immediately before

operation, and not laid away for later use, as often done. As the aseptic

material is taken from the sterilizer it is to be placed in glass cases

provided therefor, from which they are removed, as needed, during the

operation.

A simple glass case, as shown in Fig. 17, may be used, or, better still,

the same can be obtained in combination with an instrument table, as

shown in Fig. 18.

[Illustration: FIG. 17.—DRESSING CASE.]

[Illustration: FIG. 18.—COMBINATION DRESSING CASE AND TABLE.]

=Waste Cans.=—All soiled dressings and sponges should be immediately

thrown into an enameled iron pail furnished for the purpose. At no time

must soiled dressings or sponges be thrown upon the floor, where they are

walked over, soiling the floor and, by drying, contaminating the air of

the room. Cans for this purpose are made of steel, enameled, of the form

shown in Fig. 19.

The contents of the can must be taken from the room after each operation

and burned. The can should be flushed with carbolic solution, and

returned to the operating room.

[Illustration: FIG. 19.—WASTE CAN.]

SUTURES AND STERILIZATION

(_Ligatures_)

=Silkworm Gut and Silk.=—In plastic surgery silkworm gut and silk are

used extensively. Rarely is ordinary catgut resorted to, because it is

absorbed before thorough union takes place, besides being a source of

infection, either primarily from imperfect sterilization or by taking

it up from the secretions of the deeper layer of skin not affected by

external antiseptics.

The sterilization of silk is accomplished by boiling it for one hour in

a 1-20 carbolic solution and then keeping it in a 1-50 similar solution

(Czerny). Or it may be boiled in water for one hour and retained in a

1-1,000 alcoholic solution of corrosive sublimate. Ordinarily it may,

however, be simply subjected to boiling and steamed in the autocleve.

Silkworm gut is treated in the same manner. It has greater tensile

strength than silk, and for that reason the thinner varieties are to be

preferred to ordinary silk.

=Catgut.=—It is far more difficult to prepare catgut, but, since it is

necessary for ligation, the following methods may be considered best:

The commercial catgut as made from the intestines of sheep, is wound

snugly upon a rod of glass and thoroughly brushed with soft soap and hot

water. It is then rinsed free of soap, wound upon small glass spools,

and placed for forty-eight hours in a one-per-cent alcoholic bichlorid

solution, composed of bichlorid of mercury, 10 parts; alcohol, 800 parts;

distilled water, 200 parts. The turbid fluid produced by first immersion

is changed. Before using, the spools are placed in a glass vessel contain

containing a 1-2,000 sublimate alcohol (Schaffer), made up as follows:

Bichlorid of mercury gr. vj;

Alcohol ℥x;

Distilled water ℥iiss.

These glass cases are obtainable for the purpose and contain a second

perforated compartment for the ligatures passing through rubber valves

placed into the openings (Haagedorn).

Catgut is generally prepared by soaking in oil of juniper for one

week and then retaining it in absolute alcohol (Kocher), or a 1-1,000

alcoholic sublimate solution.

Another method for strengthening catgut, as well as to prevent its too

rapid absorption, is to chromatize it. This is done as follows:

The catgut is placed in sulphuric ether for forty-eight hours, then

treated for another forty-eight hours in a ten-per-cent solution

of carbolized glycerin, followed by a five-hour subjection to a

five-per-cent aqueous solution of chromic acid (Lister). It is allowed

to remain in the latter forty-eight hours, then placed in an antiseptic,

dry, tightly closed receptacle, and finally soaked in 1-20 carbolic

solution before using.

The _formaldehyd method_ of Kossman is to immerse the gut in formaldehyd

for twenty-four hours, then washing with a solution of chlorid and

carbonate of sodium and retaining it in the same solution. The catgut in

this procedure swells and its strength is much impaired in this way.

Any of the above methods are not above criticism, however, rigid as they

may seem, bacterial growths having been obtained with nearly all of them.

The _dry-air method_ (Boeckman, Reverdin) is reliable, but the subjection

of catgut to dry air at a temperature of 303° F. for two hours results in

making it tender and less pliable.

[Illustration: FIG. 20.—CLARK KUMOL APPARATUS.]

The _Kumol method_ (Kronig) is considered the most reliable, even under

the severest tests. This mode of sterilization is accomplished as

follows: A specially devised apparatus of brass, with a cast-bronze top,

both thoroughly nickel-plated, is used. The apparatus of J. G. Clark, as

shown in Fig. 20, will be found excellent. The kumol is retained in a

seamless cylinder, 8 by 8 inches, which is surrounded on the sides and

bottom by a sand bath; the flame, impinging on the bottom, heats the

sand, thereby insuring an even heat to the inner or sterilizing cylinder.

The catgut, in rings, is placed in a perforated basket hanging in the

cylinder, which can be raised or lowered at will; after drying for two

hours at 80° C., the basket is dropped, and the catgut immersed in the

kumol, at 155° C., for one hour; the kumol is then drawn off through a

long rubber tube, and the catgut dried at 100° C., for two hours; it is

then transferred to sterile glass tubes plugged with cotton.

_Prepared catgut_ of the various sizes can now, however, be purchased in

the market, and that offered by the better firms of chemists is quite

reliable and may be safely used for all plastic surgery about the face.

It is supplied in glass tubes, either in given lengths, as in the Fowler

type, in which the hermetically sealed tube is U-shaped or on glass

spools placed in glass tubes, not sealed, but closed by a rubber cap,

through which the desired length of ligature is drawn and then cut off.

Plastic and cosmetic surgery · 第 3 / 20 章