CHAPTER VIII.

SUGGESTIONS OF ARCHITECTS AND OTHER EXPERTS AS TO AVOIDING LIKE

CALAMITIES.

Robert S. Lindstrom, a well known Chicago architect, makes the following

suggestions: "It is earnestly requested that the following suggestions be

published for the benefit and warning of patrons of public places, also as

an aid to city officials, architects and builders, as a possible means of

averting another horror such as has been witnessed in the Iroquois theater

fire.

"Every theater in Chicago is virtually a death trap set for patrons even

under ordinary conditions. Barring fires and panics, the playhouses are

not amply provided with exits, and are unsafe on account of overcrowding.

Thereby each person attending a performance in any of Chicago's theaters

does so at a risk of his own life. This also applies to all halls that are

hurriedly arranged for public meetings and especially during the election

campaign work and convention gatherings.

"A theater may be absolutely fire-proof, but when the seating capacity of

the house has been overcrowded by reducing sizes of stairs, aisles and

exits the building is really worse than a non-fire-proof building, for in

the latter the smoke would have a chance to escape.

"The following suggestions will partially avert such a horror as has been

witnessed at the Iroquois, which was advertised as the safest fire-proof

theater in Chicago:

"All seats throughout the house should be placed far enough apart from

back to back so that an open passageway running from aisle to aisle shall

be large enough to allow a person to get out without disturbing all the

people seated in the section. In the Iroquois the seats in the gallery are

so closely spaced from back to back that one cannot sit in a comfortable

position at any time. All seats should be made of iron framework, with

seats fixed so that danger of catching clothing on upturned edges may be

averted, which in the present theater seats causes very much delay in a

rush. The upholstering should be done with asbestos wool and all covering

done with asbestos fire-resisting cloth.

"An aisle should be left between the orchestra and the front row of seats.

Main aisles should be made so that they connect with the aisle in front,

also the aisle in rear, without any obstructions, and an exit door placed

at end of each aisle leading directly to the vestibule. The present system

is one large door at the center so that people from the side aisles

collide with those from the center aisles and no one can get out. It is

also very important that the door opening, with doors open, is a trifle

larger than the aisle; all seats that face on aisles to be plain to

prevent clothing from catching on same.

"Carpets should be prohibited in all halls and aisles and replaced by

interlocking rubber tile or some similar covering to prevent slipping in a

rush.

"All steps should have safety treads, composed of steel and lead, in place

of slate or marble, which becomes slippery and dangerous. Stairs to be

straight without winds or turns and at every ten feet from the sidewalk

there should be a landing twice as long as the width of the stairs and

doors at the foot of the stairs should be a trifle larger than the stair

opening.

"All balconies and galleries above the first floor should have a metal

hand rail back of each row of seats securely fastened to the floor

construction.

"Doors should swing out; in addition to door handle threshold to have an

automatic opening device so as to throw doors open in case of fire or

accident. Also at each fire exit there should be in view of the audience a

box containing saw and tools and plainly marked for use in case of fire,

providing locks on doors fail to work. In addition an attendant should be

placed at each fire exit and remain there until the house is vacated

during every performance.

"Fire escapes should be made of regular stair pattern with treads eleven

inches and rises seven inches, and treads provided with steel and lead

composition covering and risers closed.

"Instead of sloping the ceiling toward the stage it should be made level

with a cone shape toward the center and there connect with a down draft

ventilator and an emergency damper controlled by a three-way switch from

stage, box office and each balcony, made large enough to form a smoke flue

in case of fire. Wires controlling this ventilator should run in conduit

fireproofed and in addition to switch an electric emergency switch

weighted with a fused link to make a contact when link breaks. Same to

apply to stage, halls and stairways, except that fireproof ducts will

connect halls and stairs with outer air. In addition to the ventilator

every part of the house should be equipped with a system of sprinklers

operated automatically by a gravity system. A large glass chandelier such

as used at the Iroquois should be prohibited.

"Emergency lights in case of fire and accidents during the performance to

light up the house should be placed on ceiling of main auditorium,

balconies, halls and stairs and built of fire-proof boxes with wired

plate-glass face. These lights should be operated on a separate system and

run in fireproof conduits, and controlled from the street front, also to

have a fusible weighted switch on stage.

"Fire doors should be constructed of steel with wired plate-glass panels

so that fire can be prevented from outside sources, but if in case of

accident the lock should fail to work from the inside, the glass panel can

be broken with tools that should be placed in reach and plainly marked.

"Calcium lights should be prohibited anywhere in the auditorium. The place

is generally on the gallery. In the Iroquois the scenic lights were placed

at the extreme top of the upper gallery, with a supporting framework that

rested on the aisle floor and obstructed aisle to audience.

"Counter-weights of curtain should be made in sections with fusible link

connections so that in case of fire curtain will drop of its own weight.

"Curtain should be constructed of steel framework and made rigid and run

in steel guides of sufficient size to allow for expansion in case of fire.

Stage floor should be four inches thick, solid, laid on concrete bed.

"A special waiting room with a special exit, entrance to same to be from

main foyer, should be used especially for patrons using carriages so as to

prevent the present system of blocking exits and vestibule with people

waiting for carriages and preventing exit of crowd.

"On stage of every theater there should be a fire plug, also a hose long

enough to reach any part of the house, to run on a reel.

"A loss of life in a panic cannot be entirely prevented, but some of the

above suggestions if carried out will, at least, prevent a wholesale loss

of human life.

"All theaters should be thoroughly investigated and where the slightest

detail is found to conflict with the law and the safety of an audience

the city officials should prevent the use of such house until it has been

properly constructed."

THE ARCHITECT SPEAKS.

Benjamin H. Marshall, architect of the theater, received the news of the

disaster in Pittsburg, Pa., and at once started for Chicago. He was

stunned by the intelligence, and, speaking of it, said:

"This seems to be a calamity that has no precedent, and I can not

understand how so many people were caught in the balconies unless they

were stunned by the shock of an explosion. There were ample fire exits and

they were available. The house could have been emptied in less than five

minutes if they were all utilized. The fact that so many people were

caught in the balconies would prove that they were stunned and

panic-stricken by the report rather than by the fear of a fire. It is

difficult for me at this time to even guess as to the cause for the great

loss of life.

"I am completely upset by this disaster, more so because I have built many

theaters and have studied every playhouse disaster in history to avoid

errors."

EXAMINATION BY ARCHITECTURAL EDITOR.

Robert Craik McLean, editor of the _Inland Architect_, who spent some time

investigating the claim that the theater was equipped with an asbestos

fire curtain, said: "After a careful investigation, I am convinced that

the theater was not equipped with a curtain such as is demanded by the

city ordinances.

"I visited the damaged theater, but there was no sign of an asbestos

curtain. Fire will not destroy asbestos, and if there was a curtain there

when the holocaust occurred it had been removed, and an investigation

should be made to learn what became of it. If no curtain had been removed,

as is claimed, I cannot understand how the claim can be set up that the

theater had a fire curtain. No one denies that there was a curtain there,

but had it been made of asbestos, as required by the ordinance, it would

not have been destroyed by the draft of air, as is claimed by the

management of the house. An asbestos curtain must have a foundation of

wire or some other material, and had the Iroquois been equipped with such

a drop the wire screen, at least, would be there to prove it."

"Mr. Samuel Frankenstein of the Frankenstein Calcium Light company, made

the statement to me that he had had a conversation with the stage manager

of the Iroquois regarding the fire drop. Mr. Frankenstein said that the

stage manager told him that the Iroquois stage was not equipped with a

true fire curtain. According to Mr. Frankenstein, the stage manager went

further than this, and declared that there were only three theaters in

Chicago equipped with real asbestos drops."

PROPOSED PRECAUTIONS FOR NEW YORK THEATERS.

Charles H. Israels of the firm of Israels & Harder, architects of the new

Hudson theater, and several of the large hotels, suggested a number of

precautions which might be adopted in New York theaters. Among other

things he advocated an ordinance requiring all the theater emergency exits

to be used after each performance.

"Nearly every modern theater in this city," Mr. Israels said, "is

adequately provided with exits, with which the audience are not familiar,

and which are used so seldom that the employes are unused to having the

audience pass out through them. Besides the one exit ordinarily in use

there are four emergency exits, and the law requires them to open either

on a brick enclosed alley at the side of the theater or directly into the

street.

"The people in the gallery, who are in the place of the greatest danger,

would undoubtedly become thoroughly accustomed to using these outside

stairways.

"The main advantage to be gained by this suggestion over all others is

that it could be put into immediate operation without the spending of a

single cent on the part of the owners of most of New York's playhouses.

"In a few of the theaters it might be argued that the stairways at the

emergency exits were not sufficiently inclosed to allow the crowds to pass

down in safety. The law now requires the stairways to be covered at the

top, and covering the outside rail with heavy wire mesh raised about two

feet above its present level would prevent any one from falling over the

side.

"Fireproof scenery or scenery which will at least not flame, is a

practical possibility now. The building code should compel the use of

scenery on frames of light metal covered with canvas that has been

saturated in a fireproof solution. Fireproof paint is compulsory on the

woodwork behind the proscenium wall, but in painting scenery combustible

paint may be used.

"The law should be most strictly enforced as to the cleaning out of

rubbish beneath the stage. In a number of the theaters of New York this is

done only occasionally."

"Lest We Forget": Chicago's Awful Theater Horror · 第 8 / 26 章