FIG. 16. CABINETS FOR SAND-BLASTING SMALL CASTINGS.

(The castings are placed in the cabinets and are held and turned about

by the operators, who watch the progress of the work through glass

panels. The dust is carried off through the exhaust ducts.)]

Illumination.

The average foundry is poorly lighted, and many accidents may be

attributed directly to this condition. There are many problems to be

considered in providing proper and adequate light for foundries, and as

the conditions that have to be met vary a great deal, it is impossible

to make any general recommendations that will be applicable in all

cases.

The floors, walls, supporting columns, ceilings, and materials in

foundries are usually covered with grime and dust which absorb from 95

to 98 per cent. of the light that strikes them, and which give them

all the same general tone or color. With no contrasting background

it becomes exceedingly difficult, at times, to distinguish objects

lying upon the floor, and care should therefore be taken to see that

the floor is kept free from tools, materials, and obstacles of every

other kind, over which the workmen might stumble. Moreover, if the

ventilating system is inadequate to keep the air reasonably clear,

the dust, smoke, and gases will not only reduce the intensity of the

illumination and thereby invite accidents, but may also affect the

health of the working force.

During certain stages of the work,--notably at pouring time,--the men

are exposed to a dazzling, blinding radiation from the white-hot,

molten metal. Very often, too, lighting units of intense intrinsic

brilliance and high candle-power are placed where they shine directly

into the eyes of the men. Conditions such as these impair the vision

of the worker, thereby reducing his efficiency as a producer, and

multiplying the opportunities for accidents.

One of the best artificial lighting sources for foundry work is the

Mazda C lamp (500 to 1,000 watt sizes). To determine the proper

location of the lamps, and their spacing, suspension heights, and other

features (such as the types of reflectors that should be used) it is

necessary to understand, as fully as possible, the exact conditions

that must be met. Where incandescent lighting units are to be used,

wall brackets, fitted with angle reflectors, provide the best means of

securing satisfactory illumination at the floor level. Good results may

be obtained by installing the brackets on the supporting columns, under

the crane runway and below the smoky zone.

Although we have spoken only of artificial light for foundries, it is

important to admit the greatest possible amount of natural light. As

a usual thing, skylights are of little value on account of the clouds

of smoke that often fill the upper part of the building, and therefore

practically all the natural light that can be really serviceable

must pass through windows in the side walls. For the same reason the

effective window area must be considered as only that below a height of

approximately twelve feet. It is essential that the windows occupy as

much of the wall space as possible, and, where the width of the room

is great, prism glass should be used. Prism glass, when properly set,

will reflect the light into the room in a nearly horizontal direction.

Satisfactory natural illumination can hardly be had without keeping

the windows clean; and we also strongly advise whitewashing the walls,

ceilings, and supporting columns, applying fresh coats whenever they

are needed.

[Illustration:

_Courtesy of American Blower Company._

Safe foundry practice · 第 10 / 18 题