=Class 4.=--Large or small plant where carpet cleaning is not an

important function of the cleaning system.

Renovators: Same as for Class 3.

Hose: 1¹⁄₂ in. or 1-³⁄₄ in.

Separators: One centrifugal, dry, with or without bag, according to

type of exhauster adopted.

Vacuum Producer: Centrifugal fan or two-impeller rotary pump.

Capacity: 70 to 90 cu. ft. of free air per minute for each sweeper of

plant capacity, with a vacuum of from 2 in. to 3 in. mercury.

Size of motor: 1 to 2 H. P. for each sweeper of plant capacity.

Control: With centrifugal fan, none; with pump, Cutler Hammer.

It is interesting to note that to produce the most efficient plant

for all of the four cases named, all of the various types of vacuum

cleaning systems which have come into general use have to be operated

each under its most favorable conditions and the engineer should

select his plant to best fulfill the conditions of the special case

at hand, just as he would select his prime mover for an electric

generating plant according to its size and location. There should be

no more reason why any one of these systems should attempt to fulfill

the requirements of every installation than there would be for a

manufacturer of steam engines to attempt to use the same type of engine

to drive a generator under all conditions. The writer believes that

this condition will soon be realized by all manufacturers of vacuum

cleaning systems and that they will endeavor to install apparatus of

the type best suited to the conditions to be met in each case.

CHAPTER XIII.

TESTS.

Having decided on the type of vacuum cleaning system that is best

suited to the conditions of the particular building in which it is

to be installed, it then becomes necessary to ascertain what are the

tests necessary to determine whether the installation will produce the

desired results.

If the installation is one in which carpet cleaning is important and

the plant is of more than one-sweeper capacity, the exhauster must

be of sufficient capacity to produce a vacuum of not less than 4 in.

mercury at a carpet renovator attached to any inlet on the piping

system, when the plant is operating other renovators of any type

attached to any of the other inlets corresponding to one less than the

total sweeper capacity of the system.

When hose lengths as short as 25 ft. can be used on any or all of the

outlets, it has been demonstrated in Chapter VII that an air removal of

70 cu. ft. of free air per minute for each sweeper of plant capacity is

necessary, no matter what size of hose is used. It was also shown that

where pipe lines are very long and it is possible to always use 100 ft.

of hose, efficient cleaning can be done with less expenditure of power

with an air displacement of 45 cu. ft. of free air for each sweeper of

plant capacity.

Many methods have been recommended for testing a cleaning plant.

Perhaps the earliest was the maintaining of 15 in. of vacuum at the

vacuum producer with carpet renovators each attached to 100 ft. of

hose, equal in number to the sweeper capacity of the plant in operation

on carpets. Another test is to attach 100-ft. lengths of hose to inlets

on the system, with the ends wide open, equal in number to the sweeper

capacity of the plant, and require the pump to maintain a vacuum of 15

in. mercury.

Both of these tests were recommended for use on plants where 1-in.

diameter hose was provided and the results are dependent largely on the

size and length of the piping system. With an average-sized system, the

first test will require an exhaustion of approximately 25 cu. ft. of

free air per renovator per minute if Type A renovators are used. The

second test wall require an exhaustion of approximately 50 cu. ft. of

free air per open hose per minute. Neither of these tests will insure

a plant of sufficient capacity to do effective cleaning where 25-ft.

lengths of 1-in. hose can be used or if larger bore than 1-in. hose be

used.

If these tests are required with bores larger than 1-in. diameter

and the vacuum is maintained the same as before, air exhaustion with

1¹⁄₄-in. open hose will be approximately 70 cu. ft. of free air per

open hose, and with 1¹⁄₂-in. hose, approximately 150 cu. ft. per open

hose, while, if carpet renovators be used, the vacuum at the renovator

would be from 7 to 9 in. of mercury. In either case, the vacuum

required to be maintained at the separators is higher than is necessary

to produce economical cleaning with either 1¹⁄₄-in. or 1¹⁄₂-in. hose.

Tests with carpet renovators attached to 100 ft. hose lines in number

equal to the capacity of the plant, and a vacuum of 4¹⁄₂ in. of mercury

at the renovator will result in an exhaustion below that necessary

to produce efficient cleaning when bare floor renovators and carpet

renovators with shorter hose lines are used, as is likely to occur in

actual practice.

Again, open hose tests require a variable length of hose to be used in

order to obtain the same air quantity with the proper vacuum at the

separator for economical operation.

If 70 cu. ft. of air is desired, as in the case of Class 2 plant

(Chapter XII), the hose lengths should be:

50 ft. 1 in. diameter. 12 in. vacuum at separator.

75 ft. 1¹⁄₄ in. diameter. 9 in. vacuum at separator.

125 ft. 1¹⁄₂ in. diameter. 6 in. vacuum at separator.

Any of these lengths would give satisfactory cleaning with one carpet

renovator in use, together with sufficient bare floor renovators to

equal the capacity of the plant. This is a possible condition in any

plant.

Another method of testing is to measure the actual air passing through

a given length of hose and require sufficient vacuum at the separator

to produce this flow. This method is open to the objection that

variation in the size of the hose will result in considerable variation

in the vacuum at the separator and conditions of hose lengths may be

such that when carpet renovators are attached to the hose, the vacuum

at the renovator will vary according to the resistance offered to the

passage of the air by the friction in the hose. With the small hose,

the friction will be greatest, and the reduction in the quantity of air

passing the renovator from that passing an open hose will result in the

greatest reduction in friction loss through the hose and produce the

highest vacuum at the renovator. This will cause a widely different

vacuum at the renovator with different sizes of hose, each of which

passes the same amount of air with the end of hose open.

What is desired in cleaning operations is a certain degree of vacuum

at the carpet renovator, with the system operated under the same

conditions that will obtain in practical cleaning, and with cleaners of

various types attached to hose ends equal in number to the capacity of

the plant.

The most rational system of testing is one in which the actual

conditions of air quantity and vacuum are measured at the hose ends.

This can be obtained by actually attaching cleaning tools to the hose

ends and measuring the vacuum within the renovator. However, a wide

variation in vacuum will result when the renovator is moved along the

carpet, and this variation will be different with different operators

and different grades of carpet to such an extent as to render it

impossible to actually meet any requirements that may be specified,

unless a considerable variation in vacuum is permitted.

It is also possible for an operator to become so expert in the

manipulation of the renovators as to be able to meet the specification

requirements with a plant which will not give satisfactory results in

actual operation.

The most satisfactory method of testing that has been devised is the

use of an orifice of proper size fixed to the hose end and measure

the vacuum just inside of this orifice. In making such measurements

care must be taken that the tube connecting to the vacuum gauge is not

inserted in such a manner that the air velocity affects the reading

of the vacuum gauge. The shape of orifice must also be carefully

specified, as the rounding of the edges of the opening will greatly

increase the quantity of air passing a given-sized orifice. The

best standard is a sharp-edged orifice in a thin disk which has a

coefficient of ingress of approximately 65%.

[Illustration: FIG. 104. VACOMETER FOR USE IN TESTING VACUUM CLEANING

SYSTEMS.]

A convenient form of testing appliance based on the orifice test is

the vacometer, manufactured by the Spencer Turbine Cleaner Company

and shown in Fig. 104. This device consists of a spherical aluminum

casting, with a 1-in. diameter hole on the equatorial circle, a vacuum

gauge being attached to one polar extremity, the other being attached

to the end of the hose. A ring having a slip fit is placed around the

equatorial circle in which openings varying from ¹⁄₂-in. to ⁷⁄₈-in.

diameter are drilled. By turning this ring any of the orifices may be

made to register with the opening in the sphere. The opening to which

the vacuum gauge is attached is so located that it is not affected by

the entering air current, and its readings are not affected by the

velocity head.

Experiments with this instrument in connection with a Pitot tube show

that a ¹⁄₂-in. diameter orifice is equivalent to a Type A carpet

renovator, a ⁵⁄₈-in. orifice to a Type F renovator and a ⁷⁄₈-in.

orifice to a bare floor renovator.

With instruments of this type equal in number to the capacity of the

plant in sweepers, attached to the ends of the cleaning hose, it is

possible to obtain uniform conditions equal to the average results that

will be obtained in actual practice with renovators attached to the

hose, without the possibility of expert manipulation of the renovators

affecting the results.

The proper orifice to be used in each vacometer during the test will

vary with the character of the service for which the plant is designed,

and the author recommends the following for each of the classes of

plants described in Chapter XII:

Class 1. 2-in. mercury, with ¹⁄₂-in. orifice, maximum length of hose to

be used in actual cleaning.

Class 2. One-half the inlets ¹⁄₂-in. orifice, 4.5 in. mercury at one

orifice attached at end of longest hose desired to use in practice, the

remaining ¹⁄₂-in. outlets on shorter hose lengths. The other half of

inlets to have ⁷⁄₈-in. orifices open at same time, with longest hose on

one-quarter of total inlets and shortest on the balance.

Class 3. All inlets on long hose, one-half with ¹⁄₂-in. orifice,

balance with ⁷⁄₈-in.

Class 4. All inlets to have ⁷⁄₈-in. orifice and 1 in. vacuum at

vacometer, all hose lines maximum length.

CHAPTER XIV.

SPECIFICATIONS.

Before the engineer begins to prepare his specifications for a proposed

vacuum cleaning system, he will naturally consider carefully the

conditions to be met in the particular installation contemplated.

Having considered these conditions, he can readily determine the

type of system that will operate most efficiently and economically

under such conditions. It is, therefore, natural to assume that

the best interests of his clients can be obtained by confining his

specifications to apparatus of the type giving the most efficient

results for the special conditions to be met. However, it is also

necessary to study the apparatus on the market to determine if there is

a sufficient number of manufacturers producing the particular type of

apparatus specified to insure healthy competition and reasonable bids.

It becomes necessary, therefore, to examine the various systems offered

by the manufacturers in order to determine what competition can be

obtained.

Apparatus for Class 1 or Class 2, if confined to the positive

displacement rotary exhausters of the two-impeller type, can be

obtained from at least seven manufacturers. If the centrifugal fan is

included, at least three other manufacturers can be considered and in

either case a healthy competition be had.

If apparatus of Class 3 is desired, it can be obtained from at least

three manufacturers. A few years ago more manufacturers of systems of

this type were in the market. Some of these have dropped out, owing to

the comparatively limited field for this apparatus. However, there are

still enough manufacturers in the field to insure competition.

Apparatus of Class 4 has been especially manufactured by one company.

However, any of the manufacturers of centrifugal fan type of apparatus

can easily meet the specification requirements for apparatus of the

character.

It is, therefore, evident that the specification of apparatus of the

type best suited to any particular installation will not result in lack

of competition, and such a procedure would apparently be justified.

There are installations, such as those for public buildings, where it

may be advisable from an administrative standpoint to allow the widest

competition possible. In such cases the engineer can secure the best

results for his clients by so drawing his specifications as to include

all types of apparatus, fixing carefully the test requirements to be

met and requiring each bidder to state in his proposal the amount of

power required to operate his apparatus under full load, three-quarter

load and half-load conditions, and to base the award of the contract on

an evaluation basis.

To determine what the basis of this evaluation shall be it is first

necessary to ascertain the length of time the plant will be operated

at each of the loads specified and find the annual cost of a unit of

power to operate the plant. Assuming the plant has a life of ten years,

we can charge 10% depreciation, add to this 5% for interest on the

investment and 1% for insurance. We can capitalize the saving in power

at 16% and use this amount as a basis for evaluation.

As an example, assume one bidder guarantees a power consumption of 1

K. W. less at full load, 1.25 K. W. less at three-quarters load and

0.75 K. W. more at half load than a lower bidder. Assume the plant will

operate 500 hrs. per year at full load, 200 hrs. at three-quarters load

and 300 hrs. at half load. The total kilowatt hours saved by the more

economical plant will be:

Full load 500 × 1 = 500

Three-quarter load 200 × 1.25 = 250

---

Total saving 750

One-half load, 300 × 0.75 = 225

---

Net saving (K. W. Hr.) 525

If power costs 5 cents per K. W. Hr. the yearly saving will be $26.25,

which, capitalized at 16%, will equal $164.00. This is the amount which

the owner would be justified in paying for the more economical plant

above the price asked for the cheaper, but less economical, system.

In order to guard against any bidder guaranteeing a lower power

consumption than he can actually show on test, it is necessary to

impose a penalty for failure to meet the guarantee which is in excess

of the increase in price shown to be justified by the evaluation.

The author recommends that this penalty be made not less than 150% of

the increase in price shown by the evaluation.

Actually, the owner will not lose by the less efficient plant any more

than the amount shown by the evaluation if he junks the plant at the

end of ten years. However, it is more than likely that he will either

use it for a longer time or will be able to realize something for

the plant when it is displaced. The increased penalty, therefore, is

justified, and it is absolutely necessary to make this penalty greater

than the increased value to prevent the bidder guaranteeing a power

consumption lower than he can show on test.

The following pages contain sample specifications for apparatus of

each of the four classes of systems described in Chapter XII and a

specification permitting the widest competition, with evaluation and

penalty clauses.

CLASS 1

PLANT FOR RESIDENCE OR SMALL OFFICE BUILDING OF ONE-SWEEPER CAPACITY.

1. _General Description._ The work included in this specification

shall be the installation of a complete vacuum cleaning system for the

removal of dust and dirt from rugs, carpets, floors, stairs, furniture,

shelves, walls and other fixtures and furnishings throughout the

building, and for conveying said dust and dirt to suitable receptacles

located where shown, together with all of the necessary cleaning tools,

hose, piping, separators, exhauster, motor, etc., as hereafter more

fully specified.

2. _Exhauster._ The exhauster in all of its details shall be made of

the best materials suitable for the purpose and shall be of approved

design and construction, and may be either of the positive displacement

(rotary) or of the multi-stage fan type.

3. _Rotary Exhauster._ The rotary displacement exhauster shall be

either of the two-impeller type or of type having single impeller

without sliding vanes revolving without friction contact with case and

with oscillating follower.

4. Exhausters fitted with sliding blade or blades will not be

acceptable.

5. All parts of the exhauster shall be rigid enough to retain their

shape when the machine is working under maximum-load conditions.

6. The impellers must be machined all over and must be of such shape

and size that they will revolve freely and not touch each other, the

follower, or the casing (cylinder) in which they are placed, but

the clearance must be of the least possible amount consistent with

successful operation.

7. The shafts must be of steel with the journals ground to size.

8. The journal boxes must be long and rigidly supported by the

headplates and placed far enough from the headplates to allow the

placing of proper stuffing boxes on the shafts.

9. The shafts of two impeller exhausters must be connected by

wide-faced steel gears, cut from the solid and securely fastened to the

shafts. Follower shaft on single impeller exhauster to be connected

to impeller shaft by crank and connecting rod. The gears shall run in

suitable oil-tight gear boxes that shall be fitted with adequate and

suitable means for lubrication.

10. _Centrifugal Fan Type._ The centrifugal fan exhauster to be so

proportioned and constructed as to handle the volume of air required at

the specified vacuum with the least possible loss. The housing shall

be of cast iron or aluminum, made in sections. The housing must be

air-tight.

11. The fan wheels to be constructed of steel or other metal of high

tensile strength, properly reinforced, and, if cast, must include hub

and arms complete in one piece. If the fan wheels are built up, they

must be strongly riveted to cast-iron, steel or brass hubs or spiders.

12. The fan wheels are to be secured to shaft with a feather and set

screws, or with left-hand screw.

13. The shaft of fan exhauster may be vertical and the wheels so

mounted that their weight will equalize or partly equalize the end

thrust, or the end thrust may be balanced by the magnetic pull of the

armature. Shaft may be horizontal and end thrust taken care of with

ball-bearing thrust rings.

14. The journal boxes for all of the above named types of exhausters

shall be of the design best adapted for the purpose and must be fitted

with first-class approved continuous lubricating devices, either sight

feed, ring oiler, or any other kind best suited for the work or design

of apparatus used.

15. _Cooling._ The rotary type of exhauster must be provided with the

necessary water connections to properly seal and cool the pump. Fan

type of exhauster must be designed to operate continuously without a

rise of temperature over 100° F. above room temperature.

16. _Speed._ Rotary exhausters shall not exceed a peripheral speed of

1,100 ft. per minute at tips of impellers.

17. Centrifugal fans shall not exceed peripheral velocity of 22,000 ft.

per minute when running under specified full-load conditions.

18. _Mounting._ The exhauster, motor and separators shall be mounted

as a unit on suitable cast-iron base plate, either mounted on legs or

resting on the basement floor.

19. _Drive._ The exhauster shall be driven by an electric motor, which

may be direct connected to the exhauster shaft or be operated with an

oak-tanned leather belt, or by cut gearing. Belt and gearing are to be

of ample size and strength for their work and must run without undue

noise or wear. Means shall be provided to take up the slack of the

belt. Furnish and place a suitable metal guard over belt and pulley

wheels that shall prevent oil being splashed outside of the base plate

and prevent clothing being caught.

20. If the exhauster is operated through cut gearing, the gearing must

be inclosed in an oil and dust proof case, which shall be fitted with

means for copious and continuous lubrication of same.

21. _Finish._ The air exhauster and motor and the base plate shall be

finished in a first-class manner, filled, rubbed down and painted at

least one coat at the shop, and after installation shall receive two

more coats, finishing tint to be as directed.

22. _Electric Motor._ Motor to be of such size that when operating

under test conditions it will not be under less than three-fourths nor

more than full-load condition. It is to be of standard make, approved

by the architect.

23. Motor to be wound for .... volts direct current.

24. Armature to be of toothed-core construction, with windings

thoroughly insulated, and securely fastened in place, and must be

balanced both mechanically and electrically.

25. Commutator segments must be of drop-forged or hard-drawn copper

of highest conductivity, well insulated with mica of even thickness

and proper hardness to insure uniform wear, and shall run free from

sparking or flashing at the brushes under all conditions of speed.

It must be free from all defects and have ample bearing surfaces and

radial depth as provision for wear.

26. Brushes to be of carbon, mounted on a common rocker arm for motor,

and to have cross-sectional area of not less than 1 square inch for

each 35 amperes of current.

27. Brush holders to be of a design to prevent chattering, with

individual adjustment in tension for each brush.

28. Bearings to be of an approved self-oiling or ring type.

29. There must be an insulation resistance between motor frame and

field coils, armature windings and brush holders of not less than 1

megohm.

30. Motor must be capable of standing a breakdown test of 1,500 volts

alternating current. Either or both of the foregoing tests to be

applied at the discretion of the architect’s agent at the time of shop

tests.

31. The maximum rise in temperature of the motor at a continuous run

(after installation at building) at full speed and full-rated load for

a period of eight hours must not exceed 50° C. in windings and 55° C.

on commutator above the surrounding atmosphere.

32. Motor to be finished in a first-class manner, filled and rubbed

down and painted two coats at the shop, and after installation to have

two more coats; finishing tints to be as directed by the superintendent

of the building.

33. _Tablet._ Furnish and mount where directed a polished slate tablet

not less than ³⁄₄ in. thick, having mounted thereon one 30-ampere,

250-volt, double-pole knife switch, with enclosed indicating fuses,

and, if displacement exhauster is furnished, one automatic self-starter

having butt contacts, cutting out starting resistance in not less than

two steps, starter to be controlled by the vacuum in separator, and

shall stop motor when vacuum rises 2 in. above that required to meet

test requirements and start motor when vacuum falls to that required

for working.

34. _Electrical Connections._ This contractor shall run feeders from

vacuum cleaner panel in switchboard where shown to the motor panel and

make all electrical connections between panel and motor, etc.

35. All wires are to be run in standard steel conduit, except those

that are so short as to be self-supporting, and these are to be cord

wrapped or otherwise protected. No wire smaller than No. 8 to be used.

36. All material and workmanship to be strictly first class. Electrical

work must show an insulation resistance of at least 1 megohm, and

to be in strict accordance with the latest edition of the “National

Electrical Code.”

37. _Dust Separator._ There shall be one dry separator located where

shown on plans, having a volume not less than 3 cu. ft.

38. The interior arrangement of the separator shall be such that no

part of same will receive the direct impact of the dust. Cloth bags

or metal screens if used in this separator shall be so placed that

nothing but the very lightest of the dust can lodge thereon, and that

same may be easily cleaned without dismantling the separator. It must

be so constructed that it shall intercept not less than 95% of the dust

entering same.

38a. Separator tank shall be constructed with steel shells, with either

cast iron or steel heads, and be fitted with suitable bases or floor

stands for support and proper openings for cleaning same. Separator

shall be fitted with iron-column mercury gauge reading 50% in excess of

operating vacuum.

39. _Pipe Lines._ All pipe lines shall be of the sizes and run as

indicated on drawings.

40. _Pipes._ All pipe conveying air is to be standard black

wrought-iron or mild-steel screw-jointed pipe, and is to be smooth

inside, free from dents, kinks, fins, or burs. Ends of pipe to be

reamed to the full inside diameter and beveled. Bent pipe to be used in

mains where necessary and where shown on plans.

41. Care must be taken in erecting pipe to maintain as nearly as

possible a smooth, uniform bore through all pipe and fittings.

42. _Fittings._ All fittings to be tough gray cast iron, free from

blowholes or other defects; smooth castings in all cases.

43. All fittings on vacuum lines must have inside diameter through body

of same size as pipe bore, and all fins, burs, or rough places must be

removed.

44. Fittings on vacuum lines are to be black or may be galvanized.

45. Where space permits, all tees and elbows must have a radius at

center line of not less than 3 in.

46. Horizontal overhead pipes to be supported with substantial pipe

hangers spaced not more than 10 ft. apart.

47. The hangers must have an approved form of adjustment and the

instructions of the superintendent in regard to securing hangers to

floor construction, etc., above must be carefully followed.

48. Where exposed pipes pass through walls or floors of finished rooms

they must be fitted with cast-iron nickel-plated plates.

49. _Clean-Out Plugs._ Brass screw-jointed clean-out plugs are to be

provided in lines at all turns where indicated on the drawing. The

clean-out plugs to be 2 in. diameter, except in the 1¹⁄₂-in. lines,

where clean-outs are to be same diameter as the lines.

50. _Exhaust Connection._ Exhaust pipe from the exhauster is to be

run up to the basement ceiling and along same into the smoke breeching

beyond damper as directed.

51. _Sweeper Inlets._ The following number of inlets are to be

provided: Subbasement      , basement      , first story      , second

story      , attic     .

52. The sweeper inlets are to be fitted with hinged covers or caps with

rubber gaskets arranged to be self-closing when hose is removed, and

those in corridors and lobby arranged to be opened with a key.

53. Inlets coming through finished walls or partitions are to be flush

pattern.

54. Inlets on risers run exposed against walls are to be set close up

against bead of fittings.

55. If contractor desires to use other form of connection than above

described which is equally satisfactory, same must be submitted to the

Architect for approval after award of the contract.

56. In this specification the word “renovator” is used to mean that

portion of the tool which is in contact with the surfaces cleaned; the

word “stem,” that portion connecting the renovator and hose; the word

“cleaner” is used to mean a complete cleaning tool.

57. The following cleaning tools are to be furnished:

One carpet renovator, with cleaning slot ¹⁄₄ in. by 12 in. long.

One bare floor renovator, 12 in. long, with curved felt-covered face.

One wall renovator, 12 in. long, with cotton flannel curved face.

One upholstery renovator, with slot ¹⁄₄ in. by 4 in.

One corner cleaner.

One radiator cleaner.

One hat brush.

One long curved stem about 5 ft. long.

One extension tube about 5 ft. long.

58. The renovators for carpets, bare floors and walls to be arranged

with adjustable swivel joint, so that same can be operated at an angle

with stem from 45° for regular use to an angle of about 80° for use

under or back of furniture and other similar places. This movable joint

to be so arranged that lips of cleaning tool will always remain in

contact with surface cleaned, and constructed so that fitted surfaces

are not exposed to dust, and the air currents when deflected to impinge

only upon surfaces which are of heavy metal and where such wear as

occurs will not affect the operation and handling of the tool.

59. All renovators and stems are to be as light as is consistent with

strength and ability to withstand cutting action of dust.

60. The lips of carpet renovators and upholstery cleaner to be of such

proportions and form as will prevent injury to the fabric, and such

widths as will reduce to a minimum the sticking of renovator face to

the material being cleaned.

61. Stems to be not less than 1 in. outside diameter. Air passages in

swivels to be same diameter as inside of stem. Stem for use with floor

renovators shall be curved near upper end to form handle and provided

with swivel to permit hose hanging vertical.

62. Stems to be drawn-steel or brass tubing, not less than No. 21

United States standard gauge thick if steel and not less than No. 16

Brown & Sharpe gauge thick if brass.

63. Carpet renovators to be made preferably of pressed steel, as light

as possible, or may be made of cast iron, brass or aluminum with iron

wearing face.

64. Bare floor renovators shall have renewable elastic wearing face

curved in direction of motion when cleaning.

65. All renovators and brushes must be provided with proper rubber or

other approved buffers to prevent marring the woodwork.

66. Upholstery cleaners are to have inlet slots or openings of such

size and form as to absolutely prevent drawing in loose covering of

furniture.

67. Upholstery and corner cleaners are not to be arranged for use with

stems, but are to have their own handles permanently attached and be

provided with hose couplings.

68. All metal parts of renovators and stems are to be finished, and all

except aluminum parts nickel plated.

69. _Hose._ Furnish 75 ft. cleaning hose in three 25-ft. lengths.

70. The hose to be 1¹⁄₄ in. inside diameter best quality rubber hose,

reinforced in best manner to absolutely prevent collapse at highest

vacuum obtainable with the exhauster furnished and to prevent collapse

if stepped on. Weight of hose to be not over 12 oz. per linear foot.

71. Couplings for hose to be either slip, bayonet-lock or all-rubber

type, with smooth bore of practically same diameter as inside of

hose. The couplings to have least possible projection outside of hose

dimensions and be well rounded, so as not to injure floors, doors,

furniture, etc.

72. Bayonet joints may have packing washer, and slip joints to have

permanent steel pieces on ends of hose and brass slip coupler. All ends

of hose at couplings to have outside ferrules securely fastened in

place, or pure gum ends glued to coupling. Simple conical slip joints

slipped into ends of hose without ferrules will not be acceptable. All

joints must fit together so that they will not be readily pulled apart.

73. _Tests._ All piping to be tested with air pressure equal to 5 in.

mercury before being concealed in walls and other spaces. Mercury must

not fall more than ¹⁄₄ in. in one-half hour.

74. On completion of plant the pump will be operated with all outlets

closed and, under these conditions, there must be an interval of not

less than 10 min. between the stopping and starting of the motor by the

automatic control, if pump system is used. And if fan system be used,

the power required to operate the exhauster must not be more than 65%

that required in capacity test.

75. To test the capacity of the separator, a mixture containing 6 lbs.

of sand, passed through a 50-mesh screen, 3 lbs. of common wheat flour

and 16 lbs. of Portland cement shall be spread over 50 sq. ft. of

floor and picked up with a renovator attached to the end of 50 ft. of

1¹⁄₄-in. hose. The machine shall be stopped and the material removed

from the separator spread on floor and picked up. This procedure shall

be repeated until the material has been handled four times. If the

separator contains a bag, the same must not be disturbed until after

completion of the capacity test, which will be made with the material

in place in separator, after being picked up the fourth time.

After completion of capacity test, the contents of separator shall

be weighed and if same be a partial separator it must contain 95% of

the material picked up. If a displacement machine is used as a vacuum

producer, the separator must prevent the passage of any dust through

separator, which will be determined by holding a dampened cloth over

pump outlet during test of apparatus. Said cloth must not show any dust

lodged thereon at end of test.

76. To test the capacity of the plant a standard vacometer, attached to

the end of 75 ft. of cleaning hose shall show a vacuum of 2 in. mercury

with ¹⁄₂-in. diameter orifice open.

77. _Test of Cleaning Tools._ The plant shall be operated by the

Contractor in the presence of the Architect’s representative, and a

test made of each kind of cleaning tool furnished. The tool shall be

attached to a 50-ft. length of hose attached to an outlet selected by

the Architect’s representative, and under normal working conditions

each tool must satisfactorily perform the work for which it was

designed. Dust and surfaces to be cleaned shall be furnished by the

contractor.

78. _Painting._ After the completion of the specified tests, all

exposed iron work except galvanized iron or tinned work in connection

with this apparatus, not specified to be otherwise finished, shall be

primed with paint suitable for surfaces covered, and then given two

additional coats. Machinery shall be painted as already specified, and

all other work shall be given finishing tints as selected or approved

by the architect. Black iron pipe, etc., shall be given two coats lead

and oil of tint directed.

=Modifications of Specifications when Alternating Current is

Available.=--When alternating current is available, instead of direct,

modify specifications as follows:

23. Motor to be wound for .... volts, .... cycle, .... phase

alternating current.

24. Motor to have rotor of the squirrel cage type.

Omit 25, 26 and 27.

28. To remain as for direct current.

29. There must be an insulation between the starter or primary windings

and the frame of not less than one megohm.

30, 31, and 32. Same as for direct current.

33. _Tablet._ Furnish and mount where directed a polished slate tablet

having mounted thereon a 30 ampere, 250 volt, .... pole knife switch

with enclosed indicating fuses and, if displacement type exhauster is

furnished, an automatic starter of the “across the line” type, operated

by vacuum in the separator which will stop motor when the vacuum in the

separator rises 2 in. above that required to meet test conditions, and

start exhauster when vacuum reaches working range.

CLASS 2

PLANT FOR LARGE OFFICE BUILDING HAVING PIPE LINES OF MODERATE LENGTH.

1. Same as for Class 1.

2. Omit centrifugal fan.

3 to 9. Same as for Class 1.

Omit 10 to 13.

14 and 16. Same as for Class 1.

15. Omit centrifugal fan.

Omit 17 and 18.

18a. _Base Plate, Foundation, etc._ Provide suitable base plate to

rigidly support the exhauster and its motor as a unit, which shall be

large enough to catch all drip of water or oil. Provide a raised margin

and pads for feet of exhauster frame, motor, and anchor bolts, high

enough to prevent any drip from getting into the foundation or on the

floor.

18b. Provide suitable foundation of brick or concrete, to which the

base plate shall be firmly anchored. The foundation shall be built

on top of the cement floor of the basement, which shall be picked to

afford proper bond for the foundation.

18c. Construct the foundation of such a height as to bring the working

parts of the machine at the most convenient level for operating

purposes. Exposed parts of the foundation to be faced with best grade

white enameled brick. If the base plate does not cover the foundation,

the exposed top surface is to be finished with enameled brick, using

bull-nose brick on all edges and corners.

19 to 23. Same as for Class 1.

23a. The guaranteed efficiency of motor shall not be less than 78% at

half load and not less than 84% at full load.

24 to 32. Same as for Class 1.

32a. Motor shall be subject to shop test to determine efficiency,

heating, insulation, etc. Manufacturer’s certified test sheets of motor

giving all readings taken during shop tests, together with calculated

results, must be submitted to the Architect for approval before motor

is shipped from factory.

33. _Rheostat._ Furnish and install where shown, upon a slate panel

hereinafter specified, a starting rheostat of proper size and approved

made, designed for the particular duty it has to perform. It must

have an automatic no-voltage and overload release. All resistance for

rheostat is to be placed on the back of the tablet. Contacts must

project through board to front side. All moving parts must be on front

of board.

33a. _Tablet._ Furnish and place where shown, a slate tablet not less

than ³⁄₄ in. thick, supported by a substantial angle iron frame, so

placed that there will be a space of not less than 4 in. between the

wall and back of resistance. Mount on this tablet one double-pole,

250-volt knife switch, with two 250-volt inclosed fuses and one

starting rheostat, as specified hereinbefore. The connections shall be

on the back of the tablet. The space between the column and the tablet

shall be inclosed with a removable diamond-mesh grill of No. 10 iron

wire in channel frame.

34, 35, 36. Same as for Class 1.

36a. _Automatic Control._ Suitable means shall be provided in

connection with the rotary exhausters that will maintain the vacuum in

the separators within the limit of the machine at point found to be

most desirable, irrespective of the number of sweepers in operation.

36b. Controller shall consist of a suitable means provided in the

exhauster, or as an attachment thereto, which will automatically throw

the exhauster out of action by admitting atmospheric pressure to the

exhauster only, but not to the system whenever the vacuum in the

separators rises above the point considered desirable, and throw the

exhauster into action when the vacuum falls below the established lower

limit.

36c. _Vacuum Breaker._ In addition to the controlling devices above

specified there shall be placed in the suction pipe to the exhauster an

approved positive-acting vacuum breaker having opening equivalent to

the area of 1-in. diameter pipe and set to open at 10 inches vacuum.

(If plant is to be run for long periods without much load, as in a

hotel, omit 36a, b, c, and substitute):

36d. _Automatic Control._ An approved type of controller for

maintaining practically a constant vacuum by varying the speed of the

motor driving exhauster arranged to permit the operation of the motor

continuously at any speed between full speed and stop, so long as there

be no change in vacuum and which will increase speed whenever vacuum

falls and reduce speed whenever vacuum rises, must be provided.

37. _Dust Separator._ There shall be one dry separator located where

shown on plans, having a volume of not less than 3 cu. ft. for each

sweeper of plant capacity.

38. The interior arrangement of the separator shall be such that no

part of same will receive the direct impact of the dust. Cloth bags

or metal screens, if used in this separator, shall be so placed that

nothing but the very lightest of the dust can lodge thereon, and that

same may be easily cleaned without dismantling the separator. It must

be so constructed that it will intercept all of the dust entering same.

38a to 56. Same as for Class 1.

56a. _Tool Cases._ Furnish approved hardwood cabinet-finished cases

for cleaning tools. Each case to be made as light as possible and of

convenient form for carrying by hand and provided with a complete set

of cleaning tools, each securely held in its proper place, and fitted

with lock and key, clamps, and conveniently arranged handles.

57. Each case shall contain the following:

One carpet renovator, with slot ¹⁄₄ in. by 15 in.

One bare floor renovator, 15 in. long, with curved felt-covered face.

One wall brush, with skirted bristles, 12 in. long and ¹⁄₂ in. wide.

One hand brush, with hose connections at end, 8 in. long, 2 in. wide.

One 4-in. round brush for relief work.

One upholstery renovator.

One corner cleaner.

One radiator tool.

One curved stem about 5 ft. long.

One extension tube 5 ft. long.

At least one hat brush with the system.

58 to 64. Same as for Class 1.

64a. All brushes to be of substantial construction, with best quality

bristles set in close rows and as thick as possible, skirted with

rubber, leather, or chamois skin, so that all air entering renovator

will pass over surface being cleaned.

65 to 68. Same as for Class 1.

69. _Hose Racks._ Furnish and properly secure in place, where directed,

.... hose racks in basement, .... each in first and second stories

(.... racks in all). The racks to be constructed of cast iron,

galvanized or enamel finish, and each rack to be suitable for holding

75 ft. of hose of required size.

69a. _Hose._ There must be furnished with each hose rack 75 ft. of

noncollapsible hose in three 25-ft. lengths.

70 to 73. Same as for Class 1.

74. On completion of the plant the pump will be operated with all

outlets closed, and, under this condition, the power consumption must

not be more than 50% of that required under test conditions.

75. _Test of Separators._ At each of ---- points, near ---- outlets

on different risers selected by the architect’s representative, the

contractor shall furnish and spread on the floor, evenly covering an

area of approximately 50 sq. ft. for each outlet, a mixture of 6 lbs.

of dry sharp sand that will pass a 50-mesh screen, 3 lbs. of fine wheat

flour and 6 lbs. of Portland cement.

75b. Fifty feet of hose shall be attached to each of the ---- outlets,

and the surfaces prepared for cleaning shall be cleaned simultaneously

by operators provided by the contractor until all of the sand, flour

and Portland cement has been taken up, when the exhauster shall be

stopped and the dirt removed from the separator and spread on the floor

again, and the operation of cleaning repeated until the mixture has

been handled by the apparatus four times.

The bag contained in the separator must not be disturbed until after

completion of the capacity test, which will be made with material in

place in the separator after being picked up the fourth time. After

completion of the capacity test the contents of separator will be

removed. During test of separators a dampened cloth will be held over

the exhaust from pump. If such cloth indicates dirt passing through the

separator, same will be rejected.

76. To test the capacity of the plant, one hose line 100 ft. long

shall be attached to inlet farthest from the separator with standard

vacometer, with ¹⁄₂-in. opening in end of hose. .... hose lines shall

be attached to other outlets, each with 50 ft. hose and vacometers in

end of hose, .... vacometers having ¹⁄₂-in. opening and .... vacometers

having ⁷⁄₈-in. opening. Under these conditions 4 in. mercury must be

maintained in vacometer at end of 100 ft. of hose.

77 and 78. Same as for Class 1.

=Modifications of Specifications when Alternating Current is

Available.=--When alternating current is available, instead of direct,

modify specifications as follows:

23. Motor to be wound for .... volts, .... cycle, .... phase

alternating current.

23a. Bidders must name efficiency and power factor of motor at one-half

and full load.

24. Motor to have phase-wound rotor with collector rings for insertion

of starting resistance.

Omit 25, 26 and 27.

28. Same as for direct current.

29. There must be an insulation between the starter or primary windings

and the frame of not less than one megohm.

30, 31, 32, 32a. Same as for direct current.

33. _Rheostat._ Furnish and install an approved hand-starting rheostat

for inserting resistance in rotor circuit in starting, of proper size

to insure the starting of motor in not exceeding 15 seconds without

overheating.

33a. Same as for direct current, except that switch must be either

three- or four-pole, according to current available.

Omit 36d with alternating current machine.

CLASS 3

LARGE INSTALLATION WITH UNUSUALLY LONG PIPE LINES.

1. Same as for Class 1.

2. Exhauster shall be of the reciprocating piston type.

3. The piston type of exhauster shall be double acting and so designed

that the cylinder clearance shall be reduced to a minimum, or suitable

device shall be employed to minimize the effect of large clearance.

4. The induction and eduction valves may be either poppet, rotary, or

semi-rotary, and shall operate smoothly and noiselessly.

5. The piston packing shall be of such character as to be practically

air tight under working conditions and constructed so that it will

be set out with its own elasticity without the use of springs of any

sort. If metallic rings are used, they must fill the grooves in which

they are fitted, both in width and depth, and must be concentric; that

is, of the same thickness throughout. The joint in the ring or rings

to be lapped in width but not in thickness, and if more than one ring

is used they are to be placed and doweled in such position in their

respective grooves so that the joints will be at least one-fourth of

the circumference apart.

6. The piston shall have no chamber or space into which air may leak

from either side of the piston. All openings into the body of the

piston must be tightly plugged with cast-iron plugs.

7. The piston rod stuffing box to be of such size and depth that if

soft packing is used it can be kept tight without undue pressure from

the gland. If metallic packing is used, it must be vacuum tight without

undue pressure on the rod. Proper means shall be provided for the

continuous lubrication of the piston rod.

8. The exhauster of the piston type shall be fitted with an approved

cross-head suitably attached to the piston rod; machines having an

extended piston rod for guide purposes will not be acceptable.

Omit 9 to 13.

14. Same as for Class 1.

15. Reciprocating piston exhauster shall be provided with the

necessary devices for the removal of the heat generated by friction

and compression, that shall prevent the temperature of cylinders or

eduction chambers rising more than 100° F. above the surrounding

atmosphere after two hours’ continuous operation under full-load

conditions.

16. _Speed._ Reciprocating exhauster with poppet valves shall operate

at an average piston speed not exceeding 200 ft. per minute, with

rotary valves not exceeding 300 ft. per minute.

Omit 17 and 18.

18a. _Base Plate, Foundation, etc._ Provide suitable base plate to

rigidly support the exhauster and its motor as a unit, which shall be

large enough to catch all drip of water or oil. Provide a raised margin

and pads for feet of exhauster frame, motor, and anchor bolts, high

enough to prevent any drip from getting into the foundation or on the

floor.

18b. Provide suitable foundation of brick or concrete, to which base

plate shall be firmly anchored. The foundation shall be built on top

of the cement floor of the basement, which shall be picked to afford

proper bond for the foundation.

18c. Construct the foundation of such a height as to bring the working

parts of the machine at the most convenient level for operating

purposes. Exposed parts of the foundation to be faced with best grade

white enameled brick. If the base plate does not cover the foundation,

the exposed top surface is to be finished with enameled brick, using

bull-nose brick on all edges and corners.

19 to 23. Same as for Class 1.

23a. The guaranteed efficiency of motor shall not be less than 80% at

half load and not less than 85% at full load.

24 to 32. Same as for Class 1.

32a. Motor shall be subject to shop test to determine efficiency,

heating, insulation, etc. Manufacturers’ certified test sheets of

motor, giving all readings taken during shop test, together with

calculated results, must be submitted to the Architect for approval

before motor is shipped from factory.

33. _Rheostat._ Furnish and install where shown, upon a slate panel

hereinafter specified, a starting rheostat of proper size and approved

make, designed for the particular duty it has to perform. It must

have an automatic no-voltage and overload release. All resistance for

rheostat is to be placed on the back of the tablet. Contacts must

project through board to front side. All moving parts must be on front

of board.

33a. _Tablet._ Furnish and place where shown, a slate tablet, not less

than ³⁄₄ in. thick, supported by a substantial angle bar frame, so

placed that there will be a space of not less than 4 in. between the

wall and back of resistance. Mount on this tablet one double-pole,

250-volt knife switch, with two 250-volt inclosed fuses and one

starting rheostat, as specified hereinbefore. The connections shall be

on the back of the tablet. The space between the column and the tablet

shall be inclosed with a removable diamond-mesh grill of No. 10 iron

wire in channel frame.

34, 35 and 36. Same as for Class 1.

37. _Dust Separators._ There shall be one dry and one wet separator

located where shown on drawings. Each separator shall have a volume of

3 cu. ft. for each renovator of plant capacity.

38. The separator first receiving the dust shall be a dry separator,

the interior arrangement of which shall be such that no part of same

shall receive the direct impact of the dust. No screens or cloth bags

shall be used in this separator and it must be so constructed that it

will intercept 95% of the dust entering same.

38a. The second separator must be a wet separator which may be

contained in the base of the machine or consist of a separate tank.

38b. Wet separators, whether separate from or integral with the base of

the machine, must be provided with an attachment which will positively

mix the air and water, thoroughly break up all bubbles, separate the

water from the air, and prevent any water entering the exhauster

cylinder.

38c. Suitable means must be provided to automatically equalize the

vacuum between wet and dry separators upon the shutting down of the

exhauster.

38d. The separators must be provided with suitable openings for

access to the interior for inspection and cleaning, and the interior

arrangement of the separators must be such that they may be readily

cleaned without dismantling.

38e. All parts of the wet separator tank not constructed of

non-corrosive metal must be thoroughly tinned or galvanized both inside

and outside. The interior of the wet separator formed in base of

exhauster shall be painted with at least two coats of asphalt varnish

or other paint suitable to prevent the corrosion of same.

38f. Separators must be provided with all necessary valves or other

attachments for successful operation, including a sight glass for the

wet separator, through which the interior of the same may be observed,

and an iron-case mercury column reading 50% in excess of operating

vacuum, attached to the dry separator first receiving the dust.

38g. The wet separator shall be properly connected to water supply

where directed and discharge to sewer where shown on plans.

38h. A running trap with clean-out shall be installed in the waste line.

39 to 41. Same as for Class 1.

41a. Waste and water pipe, in connection with wet separator and jacket,

except waste pipe below basement floor, to be standard galvanized

wrought-iron pipe or steel screw-jointed pipe free from burs. Waste

pipe below the basement floor is to be best grade, “extra heavy”

cast-iron pipe, with lead-calked joints.

42 to 45. Same as for Class 1.

45a. Fittings on water lines to be standard galvanized beaded fittings.

45b. Fittings on waste line above basement floor line to be galvanized

recessed screw-jointed drainage fittings and those below basement floor

to be “extra heavy” cast-iron with hub joints.

46 to 50. Same as for Class 1.

50a. The exhaust pipe is to be fitted with an approved first-class

exhaust muffler not less than 12 in. in diameter and 60 in. high,

closely riveted and constructed of galvanized iron not less than

¹⁄₈ in. thick, and in event an exhauster requiring lubrication is

furnished, this muffler is to be arranged so that it will also be an

efficient oil separator. Drip connection to be arranged at bottom of

muffler.

51 to 56. Same as for Class 1.

56a. _Tool Cases._ Furnish .... approved hardwood cabinet-finished

cases for cleaning tools. Each case to be made as light as possible and

of convenient form for carrying by hand and provided with a complete

set of cleaning tools, each securely held in its proper place, and

fitted with lock and key, clamps and conveniently arranged handles.

57. Each case shall contain the following:

One carpet renovator, with slot ¹⁄₄ in. by 12 in.

One bare floor renovator 12 in. long, with curved, felt-covered face.

One wall brush, with skirted bristles, 12 in. long and ¹⁄₂ in. wide.

One hand brush, with hose connection at end, 8 in. long and 2 in. wide.

One 4-in. round brush for relief work.

One upholstery renovator.

One corner cleaner.

One radiator tool.

One curved stem about 5 ft long.

One straight extension stem 5 ft. long.

At least one hat brush with the system.

58 to 64. Same as for Class 1.

64a. All brushes to be of substantial construction, with best quality

bristles set in close rows and as thick as possible, skirted with

rubber, leather, or chamois skin, so that all air entering renovator

will pass over surface being cleaned.

65 to 68. Same as for Class 1.

69. _Hose Racks._ Furnish and properly secure in place where directed,

.... hose racks in basement, .... each in first and second stories

(.... racks in all). The racks to be constructed of cast-iron,

galvanized or enamel finish, and each rack to be suitable for holding

75 ft. of hose of required size.

69a. _Hose._ There must be furnished with each hose rack 75 ft. of

non-collapsible hose in three 25-ft. lengths.

70. Hose to be 1 in. inside diameter of best quality, rubber hose,

reinforced in best manner to absolutely prevent collapse at highest

vacuum obtainable with the exhauster furnished and to prevent collapse

if stepped on. Weight of hose to be not over 12 oz. per linear foot.

71, 72 and 73. Same as for Class 1.

74. On completion of the plant the pump will be operated with all

outlets closed and, under this condition, the power consumption must

not be more than 50% of that required under test conditions.

75. To test the capacity of the plant, .... hose lines each 100 ft.

long will be attached to outlets on the system and each hose fitted

with a standard vacometer. .... vacometers shall have ¹⁄₂-in. opening

and .... vacometers shall have ⁷⁄₈-in. opening. Under these conditions

4 in. vacuum must be maintained at vacometers having ¹⁄₂ in. opening.

75a. _Test of Separators._ At each of ---- points, near ---- outlets

on different risers selected by the architect’s representative, the

contractor shall furnish and spread on the floor, evenly covering an

area of approximately 50 sq. ft. for each outlet, a mixture of 6 lbs.

of dry sharp sand that will pass a 50-mesh screen, 3 lbs. of fine wheat

flour, and 1 lb. of finely pulverized charcoal.

75b. Fifty feet of hose of size required by the system shall be

attached to each of the ---- outlets, and the surface or surfaces

prepared for cleaning shall be cleaned simultaneously by operators

provided by the contractor until all of the sand, flour and charcoal

has been taken up, when the exhauster shall be stopped and the dirt

removed from the dry separator and spread on the floor again, and the

operation of cleaning repeated until the mixture has been handled by

the apparatus four times. If, after thoroughly flushing the system at

completion of above run, any dust or mud is found in the cylinder,

ports, or valve chambers of the displacement exhauster, or if less

than 95% of the dirt removed is found in the dry separator, it shall be

deemed sufficient ground for the rejection of the separators.

76 and 77. Same as for Class 1.

=Modifications of Specifications when Alternating Current is

Available.=--When alternating current is available, instead of direct,

modify specifications as follows:

23. Motor to be wound for .... volts, .... cycle, .... phase

alternating current.

23a. Bidders must name efficiency and power factor of motor at one-half

and full load.

24. Motor to have phase-wound rotor with collector rings for insertion

of starter resistance.

Omit 25, 26 and 27.

29. Same as for Class 1, alternating current.

33. _Rheostat._ Furnish and install an approved hand-starting rheostat

for inserting resistance in rotor circuit in starting, of proper size

to insure the starting of motor in not exceeding 15 seconds without

overheating.

33a. Same as for direct current, except switch must be either three- or

four-pole, according to current available.

CLASS 4

LARGE OR SMALL PLANT WHERE CARPET CLEANING IS OF SECONDARY IMPORTANCE.

1 to 17. Same as for Class 1.

Omit 18.

18a. _Base Plate, Foundation, etc._ Provide suitable base plate to

rigidly support the exhauster and its motor as a unit, which shall be

large enough to catch all drip of water or oil. Provide a raised margin

and pads for feet of exhauster frame, motor, and anchor bolts, high

enough to prevent any drip from getting into the foundation or on the

floor.

18b. Provide suitable foundation of brick or concrete, to which the

base plate shall be firmly anchored. The foundation shall be built

on top of the cement floor of the basement, which shall be picked to

afford proper bond for the foundation.

18c. Construct the foundation of such a height as to bring the working

parts of the machine at the most convenient level for operating

purposes. Exposed parts of the foundation to be faced with best grade

white enameled brick. If the base plate does not cover the foundation,

the exposed top surface is to be finished with enameled brick, using

bull-nose brick on all edges and corners.

19 to 23. Same as for Class 1.

23a. The guaranteed efficiency of motor shall not be less than 78% at

half load and not less than 84% at full load.

24 to 32. Same as for Class 1.

32a. Motor shall be subject to shop test to determine efficiency,

heating, insulation, etc. Manufacturers’ certified test sheets of

motor, giving all readings taken during shop test, together with

calculated results, must be submitted to the Architect for approval

before motor is shipped from factory.

33. _Rheostat._ Furnish and install where shown, upon a slate panel

hereinafter specified, a starting rheostat of proper size and approved

make, designed for the particular duty it has to perform. It must

have an automatic no-voltage and overload release. All resistance for

rheostat is to be placed on the back of the tablet. Contacts must

project through board to front side. All moving parts must be on front

of board.

33a. _Tablet._ Furnish and place where shown, a slate tablet not less

than ³⁄₄ in. thick, supported by a substantial angle iron frame, so

placed that there will be a space of not less than 4 in. between the

wall and back of resistance. Mount on this tablet one double-pole,

250-volt knife switch, with two 250-volt inclosed fuses and one

starting rheostat, as specified hereinbefore. The connections shall be

on the back of the tablet. The space between the column and the tablet

shall be enclosed with a removable diamond-mesh grill of No. 10 wire in

channel frame.

34, 35 and 36. Same as for Class 1.

36a. _Automatic Control._ Suitable means shall be provided in

connection with the rotary exhauster that will maintain the vacuum in

the separators within the limit of the machine at point found to be

most desirable, irrespective of the number of sweepers in operation.

36b. Controller shall consist of a suitable means provided in the

exhauster, or as an attachment thereto, which will automatically throw

the exhauster out of action by admitting atmospheric pressure to the

exhauster only, but not to the system; whenever the vacuum in the

separator rises above the point considered desirable, and throw the

exhauster into action when the vacuum falls below the established lower

limit.

36c. In addition to control, a positive vacuum breaker having an

opening equal to 1 in. diameter pipe net for 6 in. of mercury, must be

provided on separator.

36d. If centrifugal fan is used, no control or vacuum breaker will be

required.

37. Furnish one separator having a cubic contents of 4.5 cu. ft. for

each sweeper of plant capacity.

38 to 56. Same as for Class 1.

56a. _Tool Cases._ Furnish approved hardwood cabinet-finished cases

for cleaning tools. Each case to be made as light as possible and of

convenient form for carrying by hand and provided with a complete set

of cleaning tools, each securely held in its proper place, and fitted

with lock and key, clamps, and conveniently arranged handles.

57. Each case shall contain the following:

One carpet renovator ¹⁄₂ in. by 15 in.

One bare floor renovator, 15 in. long, with curved felt-covered face.

One wall brush, with skirted bristles, 12 in. long and ¹⁄₂ in. wide.

One hand brush, with hose connection at end, 8 in. long and 2 in. wide.

One 4-in. round brush for relief work.

One upholstery renovator.

One corner cleaner.

One radiator tool.

One curved stem about 5 ft. long.

One straight extension stem 5 ft. long.

At least one hat brush with the system.

58 to 68. Same as for Class 1.

69. _Hose Racks._ Furnish and properly secure in place, where

directed, .... hose racks in basement, .... each in first and second

stories (.... racks in all). The racks to be constructed of cast-iron,

galvanized or enamel finish, and each rack to be suitable for holding

75 ft. of hose of required size.

69a. _Hose._ There must be furnished with each hose rack 75 ft. of

non-collapsible hose in three 25-ft. lengths.

70. Hose to be 1¹⁄₂ in. or 1-³⁄₄ in. inside diameter, best quality

rubber hose, reinforced in best manner to absolutely prevent collapse

at highest vacuum obtainable with the exhauster furnished and to

prevent collapse if stepped on. Weight of hose to be not over 12 oz.

per linear foot.

71 to 73. Same as for Class 1.

74. On completion of the plant the pump will be operated with all

outlets closed and, under this condition, the power consumption must

not be more than 50% of that required under test conditions.

75. Same as for Class 1.

76. To test the capacity of the plant, .... hose lines each 75 ft. long

shall be attached to the inlets, each hose to be fitted with standard

vacometer with ⁷⁄₈-in. opening. Under these conditions a vacuum of 1

in. mercury must be maintained in each vacometer.

77 and 78. Same as for Class 1.

CLASS 5

TO GIVE WIDEST COMPETITION.

1. Same as for Class 1.

2. Exhauster to be piston, rotary or centrifugal fan type.

3. The piston type of exhauster shall be double-acting and so designed

that the cylinder clearance shall be reduced to a minimum, or suitable

devices shall be employed to minimize the effect of large clearances.

4. The induction and eduction valves may be either poppet, rotary or

semi-rotary, and shall operate smoothly and noiselessly.

5. The piston packing shall be of such character as to be practically

air tight under working conditions and constructed so that it will be

set out with its own elasticity without the use of springs of any

sort. If metallic rings are used, they must fill the grooves in which

they are fitted, both in width and depth, and must be concentric; that

is, of the same thickness throughout. The joint in the ring or rings

to be lapped in width but not in thickness, and if more than one ring

is used they are to be placed and doweled in such position in their

respective grooves so that the joints will be at least one-fourth of

the circumference apart.

6. The piston shall have no chamber or space into which air may leak

from either side of the piston. All openings into the body of the

piston must be tightly plugged with cast-iron plugs.

7. The piston-rod stuffing box to be of such size and depth that if

soft packing is used it can be kept tight without undue pressure from

the gland. If metallic packing is used, it must be vacuum tight without

undue pressure on the rod. Proper means shall be provided for the

continuous lubrication of the piston rod.

8. The exhauster of the piston type shall be fitted with an approved

cross-head suitably attached to the piston rod; machines having an

extended piston rod for guide purposes will not be acceptable.

Insert paragraphs 3 to 15 from specifications for Class 1.

15a. Reciprocating exhauster shall be provided with the necessary

devices for the removal of the heat generated by friction and

compression, that shall prevent the temperature of cylinders or

eduction chambers rising more than 100° F. above the surrounding

atmosphere after two hours’ continuous operation under full load

conditions.

15b. _Speed._ Reciprocating exhauster with poppet valves shall operate

at an average piston speed not exceeding 200 ft. per minute, with

rotary valves not exceeding 300 ft. per minute.

Insert paragraphs 16 and 17 from specifications for Class 1.

Omit 18.

18a. _Base Plate, Foundation, etc._ Provide suitable base plate to

rigidly support the exhauster and its motor as a unit, which shall be

large enough to catch all drip of water or oil. Provide a raised margin

and pads for feet of exhauster frame, motor, and anchor bolts, high

enough to prevent any drip from getting into the foundation or on the

floor.

18b. Provide suitable foundation of brick or concrete, to which the

base plate shall be firmly anchored. The foundation shall be built

on top of the cement floor of the basement, which shall be picked to

afford proper bond for the foundation.

18c. Construct the foundation of such a height as to bring the working

parts of the machine at the most convenient level for operating

purposes. Exposed parts of the foundation to be faced with best grade

white enameled brick. If the base plate does not cover the foundation,

the exposed top surface is to be finished with enameled brick using

bull-nose brick on all edges and corners.

19 to 23. Same as for Class 1.

23a. The guaranteed efficiency of motor shall not be less than 78% at

half load and not less than 84% at full load.

24 to 32. Same as for Class 1.

32a. Motors shall be subject to shop test to determine efficiency,

heating, insulation, etc. Manufacturers’ certified test sheets of

motor, giving all readings taken during shop test, together with

calculated results, must be submitted to the architect for approval

before motor is shipped from factory.

33. _Rheostat._ Furnish and install where shown, upon a slate panel

hereinafter specified, a starting rheostat of proper size and approved

make, designed for the particular duty it has to perform. It must

have an automatic no-voltage and overload release. All resistance for

rheostats is to be placed on the back of the tablet. Contacts must

project through board to front side. All moving parts must be on front

of board.

33a. _Tablet._ Furnish and place where shown, a slate tablet not less

than ³⁄₄ in. thick, supported by a substantial angle bar frame, so

placed that there will be a space of not less than 4 in. between the

wall and back of resistance. Mount on the tablet one double-pole,

250-volt knife switch, with two 250-volt enclosed fuses and one

starting rheostat, as specified hereinbefore. The connections shall be

on the back of the tablet. The space between the column and the tablet

shall be enclosed with a removable diamond-mesh grill of No. 10 iron

wire in channel frame.

34, 35 and 36. Same as for Class 1.

36a. _Automatic Control._ Suitable means shall be provided in

connection with the reciprocating and rotary exhausters that will

maintain the vacuum in the separators within the limit of the machine

at point found to be most desirable, irrespective of the number of

sweepers in operation.

36b. Controller shall consist of a suitable means provided in the

exhauster, or as an attachment thereto, which will automatically throw

the exhauster out of action by admitting atmospheric pressure to the

exhauster only, but not to the system; or that shall cause suction from

the system to cease whenever the vacuum in the separators rises above

the point considered desirable, and throw the exhauster into action

when the vacuum falls below the established lower limit.

36c. _Vacuum Breaker._ In addition to the controlling devices above

specified, if a reciprocating or rotary exhauster is used, there

shall be placed in the suction pipe to the exhauster an approved

positive-acting vacuum breaker having opening equivalent to the area of

1-in. diameter pipe and set to open at 12 in.

36d. If centrifugal fan is used, no control or vacuum breaker will be

required.

37. _Dust Separators._ There must be provided at least one separator

between the pipe lines and exhauster having a volume of not less than

3 cu. ft. per sweeper of plant capacity. This separator must be so

constructed that no part thereof will receive the direct impact of the

dust. If rotary exhauster is used, this separator must also contain a

bag so placed that only the lightest dust will reach same and must be

arranged to be readily cleaned without dismantling the separator. If a

centrifugal exhauster is used, this apparatus may or may not contain a

bag, and, if piston pump is used, this separator must contain no bags

or screens whatever. If a piston type of exhauster is installed, an

additional separator must be placed between the first separator and the

exhauster. This must be a wet separator and may be contained in the

base of the machine or consist of a separate tank.

Omit 38.

38a. Same as for Class 1.

38b. Wet separators, whether separate from or integral with the base of

the machine, must be provided with an attachment which will positively

mix the air and water, thoroughly break up all bubbles, separate the

water from the air, and prevent any water entering the exhauster

cylinder.

38c. Suitable means must be provided to automatically equalize the

vacuum between wet and dry separators upon the shutting down of the

exhauster.

38d. The separators must be provided with suitable openings for

access to the interior for inspection and cleaning, and the interior

arrangement of the separators must be such that they may be readily

cleaned without dismantling.

38e. All parts of the wet separator tank (if used) not constructed

of non-corrosive metal must be thoroughly tinned or galvanized both

inside and outside. The interior of the wet separator formed in base of

exhauster shall be painted with at least two coats of asphalt varnish

or other paint suitable to prevent the corrosion of same.

38f. Separators must be provided with all necessary valves or other

attachments for successful operation, including a sight glass for the

wet separator (if used), through which the interior of same may be

observed.

38g. The wet separator (if used) shall be properly connected to water

supply where directed and discharge to sewer where shown on plans.

38h. A running trap with clean-out shall be installed in the waste line.

39 to 41. Same as for Class 1.

41a. Waste and water pipe, in connection with wet separator and jacket,

except waste pipe below basement floor, to be standard galvanized

wrought-iron or steel screw-jointed pipe free from burs. Waste pipe

below the basement floor is to be best grade, “extra heavy” cast-iron

pipe, with lead-calked joints.

42 to 45. Same as for Class 1.

45a. Fittings on water lines to be standard galvanized beaded fittings.

45b. Fittings on waste line above basement floor to be galvanized

recessed screw-jointed drainage fittings and those below basement floor

to be “extra heavy” cast-iron with hub joints.

46 to 50. Same as for Class 1.

50a. If reciprocating exhauster is used, the exhaust pipe is to be

fitted with an approved first-class muffler not less than 12 in. in

diameter and 60 in. high, closely riveted and constructed of galvanized

iron not less than ¹⁄₈ in. thick, and in event an exhauster requiring

lubrication is furnished this muffler is to be arranged so that it will

also be an efficient oil separator. Drip connection is to be arranged

at bottom of muffler.

51 to 56. Same as for Class 1.

56a. _Tool Cases._ Furnish ... approved hardwood cabinet-finished cases

for cleaning tools. Each case to be made as light as possible and of

convenient form for carrying by hand and provided with a complete set

of cleaning tools, each securely held in its proper place, and fitted

with lock and key, clamps, and conveniently arranged handles.

57. Each case will contain the following:

One carpet renovator, with slot ¹⁄₄ in. by not less than 12 or more

than 15 in. long.

One bare floor renovator, 15 in. long, with curved felt-covered face.

One wall brush, with skirted bristles, 12 in. long and ¹⁄₂ in. wide.

One hand brush, with hose connection at end, 8 in. long and 2 in. wide.

One 4-in. round brush for relief work.

One upholstery renovator.

One corner cleaner.

One radiator tool.

One curved stem about 5 ft. long.

One straight extension stem 5 ft. long.

At least one hat brush with the system.

58 to 64. Same as for Class 1.

64a. All brushes to be of substantial construction, with best quality

bristles set in close rows and as thick as possible, skirted with

rubber, leather, or chamois skin, so that all air entering renovator

will pass over surface being cleaned.

65 to 68. Same as for Class 1.

69. _Hose Racks._ Furnish and properly secure in place, where directed,

.... hose racks in basement, .... each in first and second stories

(.... racks in all). The racks to be constructed of cast-iron,

galvanized or enamel finish, and each rack to be suitable for holding

75 ft. of hose of required size.

69a. _Hose._ There must be furnished with each hose rack, 75 ft. of

non-collapsible hose in three 25-ft. lengths.

70. Hose shall not be less than 1 in. or more than 1-³⁄₄ in. inside

diameter, best quality rubber hose, reinforced in best manner to

absolutely prevent collapse at highest vacuum obtainable with the

exhauster furnished and to prevent collapse if stepped on. Weight of

hose to be not over 12 oz. per linear foot.

71 to 73. Same as for Class 1.

74. On completion of the plant, the pump will be operated with all

outlets closed and under this condition the power consumption must not

be more than 50% of that required under test conditions.

75. To test the capacity of plant, one hose line 100 ft. long shall be

attached to inlet farthest from the separator, with standard vacometer

with ¹⁄₂-in. opening in end of hose. Hose lines shall be attached to

other outlets, each with 50-ft. hose and vacometer in end of hose, ....

vacometers having ¹⁄₂-in. opening and .... vacometers having ⁷⁄₈-in.

opening. Under these conditions 4 in. mercury must be maintained in

vacometer at end of 100 ft. of hose.

75a. _Test of Separators._ At each of ---- points, near ---- outlets on

different risers selected by the .... representative, the contractor

shall furnish and spread on the floor, evenly covering an area of

approximately 50 sq. ft. for each outlet, a mixture of 6 lbs. of dry

sharp sand that will pass a 50-mesh screen, 3 lbs. of fine wheat flour,

and 1 lb. of finely pulverized charcoal, if wet separator be used, and

6 lbs. of Portland cement, if bag be used.

75b. Fifty feet of hose of size required by the system used shall

be attached to each of the ---- outlets, and the surface or surfaces

prepared for cleaning shall be cleaned simultaneously by operators

provided by the contractor until all of the sand, flour and charcoal

has been taken up, when the exhauster shall be stopped and the dirt

removed from the dry separator and spread on the floor again, and the

operation of cleaning repeated until the mixture has been handled by

the apparatus four times. If, after thoroughly flushing the system

at completion of the above run, any dust or mud is found in the

cylinder, ports, or valve chambers of the displacement exhauster, or

if less than 95% of the dirt removed is found in the dry separator

of the centrifugal exhauster, it shall be deemed sufficient ground

for the rejection of the separators. If bag is used, same must not be

disturbed until after capacity test, which will be made with material

in separator after being picked up the fourth time.

76-77. Same as for Class 1.

78. Evaluation of proposal (for 4-sweeper plant): No proposal will be

considered which contemplates furnishing an exhauster requiring more

power to operate under test conditions than:

Full load, 14 K. W.; three-quarter load, 12.25 K. W.; one-half load,

10.5 K. W.

Test Requirement: Paragraph 75 to be considered full load. To reduce

the load to three-quarters, one ⁷⁄₈-in. vacometer opening to be closed;

to produce one-half load, one ¹⁄₂-in. opening to be closed in addition

to the ⁷⁄₈-in. opening.

Bidders are requested to state in proposal the power consumption

required by their apparatus at full, three-quarters and one-half loads,

and in case the guarantees of the various bidders differ, they will be

evaluated as follows for the purpose of comparison:

For each full K. W. of power consumption or fractional part thereof

there will be allowed the following amount or proportionate parts for

fractional parts of a K. W. hour at the various loads:

Per Cent. of Full Load 100 75 50

Amount $156.00 $62.00 $94.00

As an illustration, let it be assumed that proposals have been received

offering equipment in accordance with specification requirements, and

the one offering the most economical apparatus based on guaranteed

power consumption names the highest price for the installation.

To determine if the purchaser will be justified in accepting the

highest proposal, let it be assumed that he has guaranteed a power

consumption of 1 K. W. less at full load, 0.75 K. W. less at

three-quarters load, and 0.25 K. W. more at half-load than the lowest

bidder. Under these conditions the algebraic sum of the saving of the

higher bidder over the lower bidder would be 156 + 46.50 - 23.50 = 179,

which is the additional amount in dollars which the purchaser would be

warranted in paying for the apparatus of higher efficiency.

In making the economy test to determine if the guaranteed power

consumption has been fulfilled, an integrating watt meter, previously

calibrated and found correct, will be placed in circuit and a two-hour

run made at each load and the power consumption based on the meter

readings.

=Penalty.=--It must be distinctly understood to be one of the

conditions under which bids are to be submitted for the work embraced

in this specification that the apparatus shall meet every requirement

of the specification and the guaranty for efficiency under which

conditions the contract price will be paid. In the event the apparatus

tested fails to meet the specified requirements for capacity or

economy, or both, the Architect shall have the right to reject the

apparatus, absolutely, and require the installation of satisfactory

apparatus, which shall comply with the contract requirements; or if

he elects to accept the same, in the event the capacity or efficiency

at any load (irrespective of other loads) is less than that named in

the proposal, then the contract price shall be the amount named in the

contract for a satisfactory plant, less the amount of deficiencies

shown by the test based on the following:

=For Capacity.=--$500.00 for each inch of vacuum and a proportionate

part thereof for each fraction of an inch below the 4 in. required in

vacometer when operating under full load.

=For Economy.=--Deduction for each K. W. or a proportionate part

thereof for each fraction thereof required in excess of guarantee.

Percentage of Full Load 100 75 50

Penalty $229.00 $93.00 $141.00

* * * * *

This evaluation was based on the same time of operation and cost of

current as that used in illustration under tests (Chapter XII).

The maximum power to be allowed for plants of various capacities should

be as follows:

Capacity in 100% 75% 50%

Sweepers of Load of Load of Load

8 24 20 17

6 20 18 15

4 14 12.25 10.5

2 7.5 ..... 6.25

In event that the plant is to be run with vacuum “on tap,” as in a

hotel, a guaranteed power consumption at no load should be required and

evaluated on the number of hours the plant will probably operate under

these conditions. This will be the largest item in the evaluation under

such conditions.

CHAPTER XV.

PORTABLE VACUUM CLEANERS.

While this book is primarily intended to deal only with vacuum cleaning

systems, which would limit the work to such apparatus as is permanently

installed within the building to be cleaned, the author considers that

it would not be complete without some mention of the portable cleaners

which are so popular at the present time.

On first consideration, the portable cleaner would appear to have a

considerable advantage over the stationary type in that the length

of hose is usually limited to not over 15 ft. and there is no pipe

line, which results in the elimination of practically all friction

loss, giving practically the same vacuum at the renovator as at the

exhauster. This should result in a saving of practically 50% of the

power required to operate the exhauster.

Referring to Chapter XII, we find that the power required to operate a

really efficient vacuum cleaning system is approximately 2.5 H. P. per

sweeper. If a portable cleaner, with the same efficiency and capacity,

be built, it would require at least 1¹⁄₂ H. P.

Such a cleaner would not be portable in the sense of the term as

applied to the most popular cleaners today. The same type has been

built on special order by the American Radiator Company, which mounted

its 1¹⁄₂ H. P. Arco Wand machine on a truck. This cleaner weighs

several hundred pounds and could be moved up and down stairs about

as easily as a sewing machine and would not be of any service in a

building not equipped with elevators. The power required to operate

this cleaner is also so great that special power wiring and large

capacity outlet plugs have to be installed throughout the building.

Such equipment has been provided in at least two department stores

where these cleaners are in use. This means that one wires his

building for vacuum cleaning instead of piping it, and there is also

the necessity of moving a heavy machine about to do the same work as a

stationary plant.

It would appear to the author that the cost of wiring would about equal

that of piping and that the additional labor required to move the

machine about would cost as much as the additional power needed by the

stationary exhauster.

This cleaner, as well as all other portable cleaners, discharges the

air from the exhauster directly back into the apartment cleaned, and is

open to the same objection that was raised against the early compressed

air cleaners. While all the dust may be caught by the dust bag, the

microbes are allowed to escape with the air and the cleaner is not a

sanitary device by any manner of means.

There are a few portable machines using rotary exhausters of the Root

type, and piston pumps, all of which are heavy to move about and, in

making them as light as possible, the efficiency of the exhauster has

been sacrificed. These machines will do the same quality of cleaning as

the stationary plants recommended for residence work and they require

about ³⁄₄ H. P., which is no less than is needed for a stationary plant

of the same capacity and efficiency.

The most popular type of portable cleaner is one which can be

attached to a socket or plug connected with the lighting system.

This should limit the power consumption to ¹⁄₈ H. P. However, many

of these cleaners use as much as 400 watts and a fair average for

cleaners retailing at about $125.00 is 250 watts. Such cleaners will

exhaust about 25 cu. ft. of air with a vacuum of 1 in. mercury at the

vacometer, a ⁵⁄₈-in. orifice being used. The theoretical power required

to move the air is approximately 50 watts and the overall efficiency

of these cleaners is, therefore, about 20%, as against 40% to 50% in

a good, one-sweeper stationary plant. The power expended in operating

these portable cleaners in proportion to the work done is no less than

with an efficient stationary plant.

Portable cleaners have been made in many types but practically all the

standard makes use one or two forms of vacuum producers, either the

diaphragm pump or the single or multi-stage fan. The pumps of the

former type are able to produce a vacuum as high as 6 in. to 10 in.

of mercury, when no air is passing, and will displace as high as 30

cu. ft. of free air per minute, when operated with a free inlet. They

produce about 1 in. of mercury at the carpet renovator when operated

on an ordinary carpet. When small-sized upholstery renovators are

used, a much higher vacuum is possible. When operated with bare floor

renovators or brushes, the quantity of air exhausted is not much over

20 cu. ft. per minute and they make very inefficient bare floor and

wall cleaners, but will do thorough carpet and upholstery cleaning

provided a small enough renovator is used.

Machines using a multi-stage fan will produce a maximum vacuum of

approximately 2 in. of mercury when exhausting no air, and will produce

a vacuum of approximately 1 in. of mercury when operated on an ordinary

carpet. With an unrestricted inlet, they will exhaust from 40 to 50 cu.

ft. of air per minute. When operated on a bare floor, they will exhaust

approximately 30 cu. ft. of free air per minute. They are, therefore,

more efficient floor cleaners than the pumps, but cannot do thorough

carpet and upholstery cleaning, no matter how small the renovator.

The smaller-fan type of machines, in which the fan is placed integral

with the carpet renovator and in which hose is not used in cleaning

floors or carpets, are provided with a single-stage fan. They produce

a suction of not exceeding ¹⁄₂ in. of mercury when no air is exhausted

and will exhaust from 5 to 10 cu. ft. of free air per minute when

operated on a carpet. With a free inlet they will exhaust from 15 to 20

cu. ft. of free air per minute. These machines are little if any better

than ordinary carpet sweepers.

Machines of this type are open to another objection in that the dust

bag is placed on the outlet of the fan and the dust in the bag is

continually agitated by the passage of the air, with the result that

all the finer particles of the dust are blown through the bag back into

the apartment. To be effective, the dust bag must always be placed on

the suction side of the exhauster and should be so arranged that the

dust will not quickly cover the entire area of the bag, for, when

this occurs, the suction is quickly reduced to such an extent that no

further cleaning can be done until the bag has been cleaned.

There is another type of mechanical cleaner manufactured by the Hoover

Suction Sweeper Company which is provided with a mechanically-operated

brush for loosening the dirt from the carpet. The dust is then conveyed

through a single-stage fan to a dust bag. The cleaner does not depend

on the vacuum to loosen the dirt and will do quite effective carpet

cleaning with a small expenditure of power. Owing to the small suction

produced, it is of little value for cleaning anything but carpets.

From the experience the author has had with portable vacuum cleaners,

some thirty makes having been tested for the Treasury Department by

him and by the Bureau of Standards, the use of such cleaners is not

considered as either an efficient or sanitary means of mechanical

cleaning.

If a cleaner requiring small power is required, one of the smaller

stationary plants, costing not over $300.00 and operating with ¹⁄₂ or

³⁄₄ H. P., is considered a better investment than $125.00 paid for a

portable cleaner.

If the purchaser feels that he cannot afford to pay more than $125.00

for his vacuum cleaner, a type such as the Water Witch can be

furnished for this price. This cleaner is placed in the basement, with

arrangements for starting same from any floor. The manufacturers state

that this apparatus produces a vacuum of 2 in. mercury in a carpet

renovator, 4 in. mercury in an upholstery renovator and exhausts 25 to

30 cu. ft. of free air per minute with open hose. The machine operates

by water pressure and the manufacturers state that it requires about

6 to 8 gals. of water per minute. All air is exhausted outside of the

building and all dust washed down the sewer with the exhaust water. It

is therefore, a fairly efficient and sanitary cleaning system.

The statements made above apply to parties who own their residences

and occupy offices in modern buildings. There are, besides these, a

great many who live in rented houses and apartments or occupy offices

in buildings where the owners are not sufficiently progressive to

install stationary cleaning plants. To supply the needs of this class

is evidently the field of the portable cleaner, as even the poorest of

these machines is more effective in the removal of dust and dirt than

the broom and carpet sweeper.

The selection of a portable cleaner by one who must necessarily resort

to the use of such a cleaner should be made with care. The motor should

be looked into and only one which has brushes readily removable and

one in which the condition of the brushes can be easily noted should

be selected. Lubrication is important. A good cleaner should be so

constructed that it can be operated for at least 100 hours without

relubrication.

The dust bag should always be on the suction side of the vacuum

producer and of such a design and construction that at least ¹⁄₂ peck

of a mixture of 40% sand, 30% flour, 15% sweepings and 15% Portland

cement can be picked up from the floor and retained in the bag and the

machine still be capable of picking up material from a bare floor.

A good test for capacity of a portable machine is to pick up ¹⁄₂ peck

of such material, then fit a thin disk with ⁷⁄₈-in. diameter opening

over the end of the hose. A machine, to be of any value, should show

a suction of 3 in. water and a first-class machine will show 8 in.

under these conditions. This will do fairly good bare floor work. To

ascertain if the machine will clean carpets, use a similar disk with

⁵⁄₈-in. diameter opening, when a suction of 7 in. water indicates the

lowest value and 16 in. about the best that can be obtained from any

portable cleaner. Cleaners must be readily portable and should not

weigh exceeding 75 lbs.

Transcriber’s Notes

Inconsistent and unusual spelling have been retained. In several

places the text appears to be incomplete or jumbled; this has not

been corrected. In many of the illustrations reference letters are

given in uppercase whereas the text uses lowercase letters; this has

not been standardised.

Inconsistencies and differences in wording and structure between the

Table of Contents and the text have not been rectified.

Page 83, paragraph starting Much of the hose in use today ...: as

printed in the source document; part of the text may be missing or

mixed up.

Changes made:

Illustrations and tables have been moved outside text paragraphs.

In some illustrations reference letters have been enhanced for the

sake of clarity; in Fig. 61 reference #1 has been added.

Obvious minor typographical and punctuation errors have been

corrected silently. In multiplications, the letter x and the

multiplication symbol (×) have been standardised to the latter.

Page 38, Table 2: F´ changed to F¹ cf. text.

Page 141: O´ changed to O¹ cf. Fig. 77a.

Page 149: ... by using metal shins ... changed to ... by using metal

shims ....

Page 170: ... the control (Fig. 107) ... changed to ... the control

(Fig. 97) ....

Page 205, item 33: ... approved made ... changed to ... approved make

....