EXPERIMENTAL TECHNIQUE

In almost all experiments, the basic signal-energy mechanism employed

has been essentially that one studied most extensively by Lillie (12),

Bonhoeffer (2), Yamagiwa (22), Matumoto and Goto (14) and others,

_i.e._, activation, impulse propagation and recovery on the normally

passive surface of a piece of iron immersed in nitric acid or of

cobalt in chromic acid (20). The iron we have used most frequently

is of about 99.99% purity, which gives performance more consistent

than but similar to that obtained using cleaned “coat-hanger” wires.

The acid used most frequently by us is about 53-55% aqueous solution

by weight, substantially more dilute than that predominantly used by

previous investigators. The most frequently reported concentration has

been 68-70%, a solution which is quite stable and, hence, much easier

to work with in open containers than the weaker solutions, results in

very fast waves but gives, at room temperatures, a very long refractory

period (typically, 15 minutes). A noble metal (such as silver, gold

or platinum) placed in contact with the surface of the iron has a

stabilizing effect (14) presumably through the action of local currents

and provides a simple and useful technique whereby, with dilution,

both stability and fast recovery (1 second) can be achieved in simple

demonstrations and experiments.

Experiments involving the growth by electrodeposition and study of

metallic dendrites are done with an eye toward electrical, physical

and chemical compatibility with the energy-producing system outlined

above. Best results to date (from the standpoints of stability,

non-reactivity, and morphological similarity to neurological

structures) have been obtained by dissolving various amounts of gold

chloride salt in 53-55% HNO₃.

An apparatus has been devised and assembled for the purpose of

containing and controlling our primary experiments. (See Figure 1).

Its two major components are a test chamber (on the left in Figure

1) and a fluid exchanger (on the right). In normal operation the

test chamber, which is very rigid and well sealed after placing the

experimental assembly inside, is completely filled with electrolyte

(or, initially, an inert fluid) to the exclusion of all air pockets and

bubbles. Thus encapsulated, it is possible to perform experiments which

would otherwise be impossible due to instability. The instability which

plagues such experiments is manifested in copious generation of bubbles

on and subsequent rapid disintegration of all “excitable” material

(_i.e._, iron). Preliminary experiments indicated that such “bubble

instability” could be suppressed by constraining the volume available

to expansion. In particular, response and recovery times can now be

decreased substantially and work can proceed with complex systems of

interest such as aggregates containing many small iron pellets.

The test chamber is provided with a heater (and thermostatic control)

which makes possible electrochemical impulse response and recovery

times comparable to those of the nervous system (1 to 10 msec). The

fluid-exchanger is so arranged that fluid in the test chamber can be

arbitrarily changed or renewed by exchange within a rigid, sealed,

completely liquid-filled (“isochoric”) loop. Thus, stability can

be maintained for long periods of time and over a wide variety of

investigative or operating conditions.

Most of the parts of this apparatus are made of stainless steel and

are sealed with polyethylene and teflon. There is a small quartz

observation window on the test chamber, two small lighting ports, a

pressure transducer, thermocouple, screw-and-piston pressure actuator

and umbilical connector for experimental electrical inputs and outputs.

Self-Organizing Systems, 1963 · 第 28 / 92 题