[17] CHAPTER I--INSTRUMENTARIUM
Direct laryngoscopy, bronchoscopy, esophagoscopy and gastroscopy
are procedures in which the lower air and food passages are
inspected and treated by the aid of electrically lighted tubes
which serve as specula to manipulate obstructing tissues out of the
way and to bring others into the line of direct vision.
Illumination is supplied by a small tungsten-filamented, electric,
"cold" lamp situated at the distal extremity of the instrument in a
special groove which protects it from any possible injury during the
introduction of instruments through the tube. The bronchi and the
esophagus will not allow dilatation beyond their normal caliber;
therefore, it is necessary to have tubes of the sizes to fit
these passages at various developmental ages. Rupture or even
over-distention of a bronchus or of the thoracic esophagus is almost
invariably fatal. The armamentarium of the endoscopist must be
complete, for it is rarely possible to substitute, or to improvise
makeshifts, while the bronchoscope is in situ. Furthermore, the
instruments must be of the proper model and well made; otherwise
difficulties and dangers will attend attempts to see them.
_Laryngoscopes_.--The regular type of laryngoscope shown in Fig. I
(A, B, C) is made in adult's, child's, and infant's sizes. The
instruments have a removable slide on the top of the tubular
portion of the speculum to allow the removal of the laryngoscope
after the insertion of the bronchoscope through it. The infant size
is made in two forms, one with, the other without a removable slide;
with either form the larynx of an infant can be exposed in but a few
seconds and a definite diagnosis made, without anesthesia, general or
local; a thing possible by no other method. For operative work on the
larynx of adults, such as the removal of benign growths, particularly
when these are situated in the anterior portion of the larynx, a
special tubular laryngoscope having a heart-shaped lumen and a
beveled tip is used. With this instrument the anterior commissure is
readily exposed, and because of this it is named the anterior
commissure laryngoscope (Fig. 1, D). The tip of the anterior
commissure laryngoscope can be used to expose either ventricle of the
larynx by lifting the ventricular band, or it may be passed through
the adult glottis for work in the subglottic region. This instrument
may also be used as an esophageal speculum and as a pleuroscope. A
side-slide laryngoscope, used with or without the slide, is
occasionally useful.
_Bronchoscopes_.--The regular bronchoscope is a hollow brass tube
slanted at its distal end, and having a handle at its proximal or
ocular extremity. An auxiliary canal on its under surface contains
the light carrier, the electric bulb of which is situated in a recess
in the beveled distal end of the tube. Numerous perforations in the
distal part of the tube allow air to enter from other bronchi when the
tube-mouth is inserted into one whose aerating function may be
impaired. The accessory tube on the upper surface of the bronchoscope
ends within the lumen of the bronchoscope, and is used for the
insufflation of oxygen or anesthetics, (Fig. 2, A, B, C, D).
For certain work such as drainage of pulmonary abscesses, the lavage
treatment of bronchiectasis and for foreign-body or other cases with
abundant secretions, a drainage-bronchoscope is useful The drainage
canal may be on top, or on the under surface next to the light-carrier
canal. For ordinary work, however, secretion in the bronchus is best
removed by sponge-pumping (Q.V.) which at the same time cleans the
lamp. The drainage bronchoscope may be used in any case in which the very
slightly-greater area of cross section is no disadvantage; but in
children the added bulk is usually objectionable, and in cases of
recent foreign-body, secretions are not troublesome.
As before mentioned, the lower air passages will not tolerate
dilatation; therefore, it is necessary never to use tubes larger than
the size of the passages to be examined. Four sizes are sufficient
for any possible case, from a newborn infant to the largest adult.
For infants under one year, the proper tube is the 4 mm. by 30 cm.;
the child's size, 5 mm. by 30 cm., is used for children aged from one
to five years. For children six years or over, the 7 mm. by 40 cm.
bronchoscope (the adolescent size) can be used unless the smaller
bronchi are to be explored. The adult bronchoscope measures 9 mm.
by 40 cm.
The author occasionally uses special sizes, 5 mm. x 45 cm., 6 mm. x 35
cm., 8 mm. x 40 cm.
_Esophagoscopes_.-The esophagoscope, like the bronchoscope, is a
hollow brass tube with beveled distal end containing a small
electric light. It differs from the bronchoscope in that it has no
perforations, and has a drainage canal on its upper surface, or next
to the light-carrier canal which opens within the distal end of the
tube. The exact size, position, and shape of the drainage outlets is
important on bronchoscopes, and to an even greater degree on
esophagoscopes. If the proximal edge of the drainage outlet is too
near the distal end of the endoscopic tube, the mucosa will be drawn
into the outlet, not only obstructing it, but, most important,
traumatizing the mucosa. If, for instance, the esophagoscope were to
be pushed upon with a fold thus anchored in the distal end, the
esophageal wall could easily be torn. To admit the largest sizes of
esophagoscopic bougies (Fig. 40), special esophagoscopes (Fig. 5) are
made with both light canal and drainage canal outside the lumen of the
tube, leaving the full area of luminal cross-section unencroached
upon. They can, of course, be used for all purposes, but the slightly
greater circumference is at times a disadvantage. The esophageal and
stomach secretions are much thinner than bronchial secretions, and, if
free from food, are readily aspirated through a comparatively small
canal. If the canal becomes obstructed during esophagoscopy, the
positive pressure tube of the aspirator is used to blow out the
obstruction. Two sizes of esophagoscopes are all that are required--7
mm. X 45 cm. for children, and 10 mm. X 53 cm. for adults (Fig. 3, A
and B); but various other sizes and lengths are used by the author for
special purposes.* Large esophagoscopes cause dangerous dyspnea in
children. If, it is desired to balloon the esophagus with air, the
window plug shown in Fig. 6, is inserted into the proximal end of the
esophagoscope, and air insufflated by means of the hand aspirator or
with a hand bulb. The window can be replaced by a rubber diaphragm
with a perforation for forceps if desired. It will be noted that none
of the endoscopic tubes are fitted with mandrins. They are to be
introduced under the direct guidance of the eye only. Mandrins are
obtainable, but their use is objectionable for a number of reasons,
chief of which is the danger of overriding a foreign body or a lesion,
or of perforating a lesion, or even the normal esophageal wall. The
slanted end on the esophagoscope obviates the necessity of a mandrin
for introduction. The longer the slant, with consequent acuting of the
angle, the more the introduction is facilitated; but too acute an
angle increases the risk of perforating the esophageal wall, and
necessitates the utmost caution. In some foreign-body cases an acute
angle giving a long slant is useful, in others a short slant is
better, and in a few cases the squarely cut-off distal end is best. To
have all of these different slants on hand would require too many
tubes. Therefore the author has settled upon a moderate angle for the
end of both esophagoscopes and bronchoscopes that is easy to insert,
and serves all purposes in the version and other manipulations
required by the various mechanical problems of foreign-body
extraction. He has, however, retained all the experimental models, for
occasional use in such cases as he falls heir to because of a problem
of extraordinary difficulty.
* A 9 mm. X 45 cm. esophagoscope will reach the stomach of almost all
adults and is somewhat easier to introduce than the 10 mm. X 53 cm.,
which may be omitted from the set if economy must be practiced.
[FIG. I.--Author's laryngoscopes. These are the standard sizes and
fulfill all requirements. Many other forms have been devised by the
author, but have been omitted from the list as unnecessary. The infant
diagnostic laryngoscope (C) is not for introducing bronchoscopes,
and is not absolutely necessary, as the larynx of any infant can be
inspected with the child's size laryngoscope (B).
A Adult's size; B, child's size; C, infant's diagnostic size; D,
anterior commissure laryngoscope; E, with drainage canal; 17,
intubating laryngoscope, large lumen. All the laryngoscopes are
preferred without drainage canals.]
[FIG. 2.--The author's bronchoscopes of the sizes regularly used.
Various other lengths and diameters are on hand for occasional use
for special purposes. With the exception of a 6 mm. X 35 cm. size
for older children, these special bronchoscopes are very rarely
used and none of them can be regarded as necessary. For special
purposes, however, special shapes of tube-mouth are useful, as,
for instance, the oval end to facilitate the getting of both
points of a staple into the tube-mouth The illustrated instruments
are as follows:
A, Infant's size, 4 mm. X 30 cm.; B, child's size, 5 mm. X 30 cm.;
C, adolescent's size, 7 mm. X 40 cm.; D, adult's size, 9 mm. X 40 cm.;
E, aspirating bronchoscope made in all the foregoing sizes, and in a
special size, 5 mm. X 45 cm.]
[FIG. 3.--The author's esophagoscopes of the sizes he has standardized
for all ordinary requirements. He uses various other lengths and sizes
for special purposes, but none of them are really necessary. A
gastroscope, 10 mm. X 70 cm., is useful for adults, especially in
cases of gastroptosis. Drainage canals are placed at the top or at the
side of the tube, next to the light-carrier canal.
A, Adult's size, 10 mm. X 53 cm.; B, child's size, 7 mm. X 45 cm.; C
and D, full lumen, with both light canal and drainage canal outside
the wall of the tube, to be used for passing very large bougies. This
instrument is made in adult, child, and adolescent (8 mm. by 45 cm.)
sizes. Gastroscopes and esophagoscopes of the sizes given above (A)
and (B), can be used also as gastroscopes. A small form of C, 5 mm. X
30 cm. is used in infants, and also as a retrograde esophagoscope in
patients of any age. E, window plug for ballooning gastroscope, F.]
[FIG. 4.--Author's short esophagoscopes and esophageal specula
A, Esophageal speculum and hypopharyngoscope, adult's size; B,
esophageal speculum and hypopharyngoscope, child's size; C, heavy
handled short esophagoscope; D, heavy handled short esophagoscope with
drainage.]
[FIG. 5.--Cross section of full-lumen esophagoscope for the use of
largest bourgies. The canals for the light carrier and for drainage
are so constructed that they do not encroach upon the lumen of the
tube.]
[25] The special sized esophagoscopes most often useful are the 8 mm.
X 30 cm., the 8 mm. X 45 cm., and the 5 mm. X 45 cm. These are made
with the drainage canal in various positions.
For operations on the upper end of the esophagus, and particularly for
foreign body work, the esophageal speculum shown at A and B, in Fig.
4, is of the greatest service. With it, the anterior wall of the
post-cricoidal pharynx is lifted forward, and the upper esophageal
orifice exposed. It can then be inserted deeper, and the upper third
of the esophagus can be explored. Two sizes are made, the adult's and
the child's size. These instruments serve, very efficiently as
pleuroscopes. They are made with and without drainage canals, the
latter being the more useful form.
[FIG. 6.--Window-plug with glass cap interchangeable with a cap having
a rubber diaphragm with a perforation so that forceps may be used
without allowing air to escape. Valves on the canals (E, F, Fig. 3)
are preferable.]
_Gastroscopes_.--The gastroscope is of the same construction as the
esophagoscope, with the exception that it is made longer, in order to
reach all parts of the stomach. In ordinary cases, the regular
esophagoscopes for adults and children respectively will afford a good
view of the stomach, but there are cases which require longer tubes,
and for these a gastroscope 10 mm. X 70 cm. is made, and also one 10
mm. X 80 cm., though the latter has never been needed but once.
[26] _Pleuroscopes_.--As mentioned above the anterior commissure
laryngoscope and the esophageal specula make very efficient
pleuroscopes; but three different forms of pleuroscopes have been
devised by the author for pleuroscopy. The retrograde esophagoscope
serves very well for work through small fistulae.
_Measuring Rule_ (Fig. 7).--It is customary to locate esophageal
lesions by denoting their distance from the incisor teeth. This is
readily done by measuring the distance from the proximal end of the
esophagoscope to the upper incisor teeth, or in their absence, to the
upper alveolar process, and subtracting this measurement from the
known length of the tube. Thus, if an esophagoscope 45 cm. long be
introduced and we find that the distance from the incisor teeth to the
ocular end of the esophagoscope as measured by the rule is 20 cm., we
subtract this 20 cm. from the total length of the esophagoscope (45
cm.) and then know that the distal end of the tube is 25 cm. from the
incisor teeth. Graduation marks on the tube have been used, but are
objectionable.
[FIG. 7.--Measuring rule for gauging in centimeters the depth of any
location by subtraction of the length of the uninserted portion of the
esophagoscope or bronchoscope. This is preferable to graduations
marked on the tubes, though the tubes can be marked with a scale if
desired.]
_Batteries_.--The simplest, best, and safest source of current is a
double dry battery arranged in three groups of two cells each,
connected in series (Fig. 8). Each set should have two binding posts
and a rheostat. The binding posts should have double holes for two
additional cords, to be kept in reserve for use in case a cord becomes
defective.* The commercial current reduced through a rheostat should
never be used, because there is always the possibility of "grounding"
the circuit through the patient; a highly dangerous accident when we
consider that the tube makes a long moist contact in tissues close to
the course of both the vagi and the heart. The endoscopist should
never depend upon a pocket battery as a source of illumination, for it
is almost certain to fail during the endoscopy. The wires connecting
the battery and endoscopic instrument are covered with rubber, so that
they may be cleansed and superficially sterilized with alcohol. They
may be totally immersed in alcohol for any length of time without
injury.
* When this is done care is necessary to avoid attempting to use
simultaneously the two cords from one pair of posts.
[FIG 8.--The author's endoscopic battery, heavily built for
reliability.
It contains 6 dry cells, series-connected in 3 groups of 2 cells each.
Each group has its own rheostat and pair of binding posts.]
_Aspirating Tubes_.--Independent aspirating tubes involve delay in
their use as compared to aspirating canals in the wall of the
endoscopic tube; but there are special cases in which an independent
tube is invaluable. Three forms are used by the author. The "velvet
eye" cannot traumatize the mucosa (Fig. 9). To hold a foreign body by
suction, a squarely cut off end is necessary. For use through the
tracheotomic wound without a bronchoscope a malleable tube (Fig. 10)
is better.
[FIG. 9.--The author's protected-aperture endoscopic aspirating tube
for aspiration of pharyngeal secretions during direct laryngoscopy and
endotracheobronchial secretions at bronchoscopy, also for draining
retropharyngeal abscesses. The laryngoscopes are obtainable with
drainage canals, but for most purposes the independent aspirating tube
shown above is more satisfactory. The tubes are made in 20 30, 40, and
60 cm. lengths. An aperture on both sides prevents drawing in the
mucosa. It can be used for insufflation of ether if desired. An
aspirating tube of the same design, but having a squarely cut off end,
is sometimes useful for removing secretions lying close to a foreign
body; for removing papillomata; and even for withdrawing foreign
bodies of a soft surface consistency. It is not often that the foreign
bodies can be thus withdrawn through the glottis, but closely fitting
foreign bodies can at least be withdrawn to a higher level at which
ample forceps spaces will permit application of forceps. Such
aspirating tubes, however, are not so safe to use as the protected,
double aperture tubes.]
[FIG. 10.--The author's malleable tracheotomic aspirating tube for
removal of secretions, exudates, crusts, etc., from the
tracheobronchial tree through the tracheotomic wound without a
bronchoscope. The tube is made of copper so that it can be bent to any
curve, and the copper wire stylet prevents kinking. The stylet is
removed before using the tube for aspiration.]
[28] _Aspirators_.--The various electric aspirators so universally
used in throat operations should be utilized to withdraw secretions in
the tubes fitted with drainage canals. They, however, have the
disadvantages of not being easily transported, and of occasionally
being out of order. The hand aspirator shown in Fig. 11 is, therefore,
a necessary part of the instrumental equipment. It never fails to
work, is portable, and affords both positive and negative pressures.
The positive pressure is sometimes useful in clearing the drainage
canal of any particles of food, tissue, clots, or secretion which may
obstruct it; and it also serves to fill the stomach or esophagus with
air when the ballooning procedure is used. The mechanical aspirator
(Fig. 12) is highly efficient and is the one used in the Bronchoscopic
Clinic. The positive pressure will quickly clear obstructed drainage
canals, and may be used while the esophagoscope is in situ, by simply
detaching the minus pressure tube and attaching the plus pressure. In
the lungs, however, high plus pressures are so dangerous that the
pressure valve must be lowered.
[Fig. 11--Portable aspirator for endoscopy with additional tube
connected with the plus pressure side for use in case of occlusion of
the drainage canal. This aspirator has the advantage of great power
with portability. Where portability is not required the electrically
operated aspirator is better.]
[FIG. 12.--Robinson mechanical aspirator adapted for bronchoscopic and
esophagoscopic aspiration by the author. The positive pressure is used
for clearing obstructed drainage canals and tubes.]
[FIG. 13.--Apparatus for insufflation of ether or chloroform during
bronchoscopy, for those who may desire to use general anesthesia. The
mechanical methods of intratracheal insufflation anesthesia
subsequently developed by Meltzer and Auer, Elsberg, Geo. P. Muller
and others have rightly superseded this apparatus for all general
surgical purposes.]
_Sponge-pumping_.--While the usually thin, watery esophageal and
gastric secretions, if free from food, are readily aspirated through a
drainage canal, the secretions of the bronchi are often thick and
mucilaginous and aspirated with difficulty. Further-more, bronchial
secretions as a rule are not collected in pools, but are distributed
over the walls of the larger bronchi and continuously well up from
smaller bronchi during cough. The aspirating bronchoscopes should be
used whenever their very slight additional area of cross-section is
unobjectionable. In most cases, however, the most advantageous way to
remove bronchial secretion has been found to be by introducing a gauze
swab on a long sponge carrier (Fig. 14), so that the sponge extends
beyond the distal end of the bronchoscope, causing cough. Then
withdrawal of the sponge carrier will remove all of the secretion in
the tube just as the plunger in a pump will lift all of the water
above it. By this maneuver the walls of the bronchus are wiped free
from secretions, and the lamp itself is cleansed.
[FIG. 14.--Sponge carrier with long collar for carrying the small
sponges shown in Fig. 15. The collar screws down as in the Coolidge
cotton carrier. About a dozen of these are needed and they should all
be small enough to go through the 4 mm. (diameter) bronchoscope and
long enough to reach through the 53 cm. (length) esophagoscope, so
that one set will do for all tubes. The schema shows method of
sponging. The carrier C, armed with the sponge, S, when rotated as
shown by the dart, D, wipes the field, P, at the same time wiping the
lamp, L. The lamp does not need ever to be withdrawn for cleaning
during bronchoscopy. It is protected in a recess so that it does not
catch in the sponges.]
[FIG 15.--Exact size to which the bandage-gauze is cut to make
endoscopic sponges. Each rectangle is the size for the tubal diameter
given. The dimensions of the respective rectangles are not given
because it is easier for the nurse or any one to cut a cardboard
pattern of each size directly from this drawing. The gauze rectangles
are folded up endwise as shown at A, then once in the middle as at B,
then strung one dozen on a safety pin. In America gauze bandages run
about 16 threads to the centimeter. Different material might require a
slightly different size and the pattern could be made to suit.]
[32] The gauze sponges are made by the instrument nurse as directed in
Fig. 15, and are strung on safety pins, wrapped in paper, the size
indicated by a figure on the wrapper, and then sterilized in an
autoclave. The sterile packages are opened only as needed. These
"bronchoscopic sponges" are also made by Johnston and Johnston, of New
Brunswick, N. J. and are sold in the shops.
_Mouth-gag_.--Wide gagging prevents proper exposure of the larynx by
forcing the mandible down on the hyoid bone. The mouth should be
gently opened and a bite block (Fig. 16) inserted between the teeth on
the left side of the patient's mouth, to prevent closing of the jaws
on the delicate bronchoscope or esophagoscope.
[FIG. 16.--Bite block to be inserted between the teeth to prevent
closure of the jaws on the endoscopic tube. This is the
McKee-McCready modification of the Boyce thimble with the omission of
the etherizing tube, which is no longer needed. The block has been
improved by Dr. W. F. Moore of the Bronchoscopic Clinic.]
_Forceps_.--Delicacy of touch and manipulation are an absolute
necessity if the endoscopist is to avoid mortality; therefore, heavily
built and spring-opposed forceps are dangerous as well as useless. For
foreign-body work in the larynx, and for the removal of benign
laryngeal growths, the alligator forceps with roughened jaws shown in
Fig. 17 serve every purpose.
[FIG. 17.--Laryngeal grasping forceps designed by Mosher. For my own
use I have taken off the ratchet-locking device for all general work,
to be reapplied on the rare occasions when it is required.]
_Bronchoscopic and esophagoscopic grasping forceps_ are of the tubular
type, that is, a stylet carrying the jaws works in a slender tube so
that traction on the stylet draws the V of the open jaws into the
lumen of the tube, thus causing the blades to approximate. They are
very delicate and light, yet have great grasping power and will
sustain any degree of traction that it is safe to exert. They permit
of the delicacy of touch of a violin bow. The two types of jaws most
frequently used, are those with the forward-grasping blades shown in
Fig. 18, and those having side-grasping blades shown in Fig. 19. The
side-curved forceps are perhaps the most generally useful of all the
endoscopic forceps; the side projection of the jaws makes them readily
visible during their closure on an object; their broader grasp is also
an advantage., The projection of the blades in the side-curved
grasping forceps should always be directed toward the left. If it is
desired that they open in another direction this should be
accomplished by turning the handle and not by adjusting the blade
itself. If this rule be followed it will always be possible to tell by
the position of the handle exactly where the blades are situated;
whereas, if the jaws themselves are turned, confusion is sure to
result. The forward-grasping forceps are always so adjusted that the
jaws open in an up-and-down direction. On rare occasions it may be
deemed desirable to turn the stylet of either forceps in some other
direction relative to the handle.
[FIG. 18.--The author's forward grasping tube forceps. The handle
mechanism is so simple and delicate that the most exquisite delicacy
of touch is possible. Two locknuts and a thumbscrew take up all lost
motion yet afford perfect adjustability and easy separation for
cleansing. At A is shown a small clip for keeping the jaws together to
prevent injurious bending in the sterilizer, or carrying case. At the
left is shown a handle-clamp for locking the forceps on a foreign body
in the solution of certain rarely encountered mechanical problems. The
jaws are serrated and cupped.]
[FIG. 19.--Jaws of the author's side-curved endoscopic forceps. These
work as shown in the preceding illustration, each forceps having its
own handle and tube. Originally the end of the cannula and stylet were
squared to prevent rotation of the jaws in the cannula. This was
found to be unnecessary with properly shaped jaws, which wedge
tightly.]
_Rotation Forceps_.--It is sometimes desired to make traction on an
irregularly shaped foreign body, and yet to allow the object to turn
into the line of least resistance while traction is being made. This
can be accomplished by the use of the rotation forceps (Fig. 20),
which have for blades two pointed hooks that meet at their points and
do not overlap. Rotation forceps made on the model of the laryngeal
grasping forceps, but having opposing points at the end of the blades,
are sometimes very useful for the removal of irregular foreign bodies
in the larynx, or when used through the esophageal speculum they are
of great service in the extraction of such objects as bones,
pin-buttons, and tooth-plates, from the upper esophagus. These forceps
are termed laryngeal rotation forceps (Fig. 31). All the various forms
of forceps are made in a very delicate size often called the
"mosquito" or "extra light" forceps, 40 cm. in length, for use in the
4 mm. and the 5 mm. bronchoscopes. For the 5 mm. bronchoscopes heavier
forceps of the 40 cm. length are made. For the larger tubes the
forceps are made in 45 cm., 50 cm., and 60 cm. lengths. A
square-cannula forceps to prevent turning of the jaws was at one time
used by the author but it has since been found that round cannula
pattern serves all purposes.
[FIG. 20.--The author's rotation forceps. Useful to allow turning of an
irregular foreign body to a safer relation for withdrawal and for the
esophagoscopic removal of safety pins by the method of pushing them
into the stomach, turning and withdrawal, spring up.]
_Upper-lobe-bronchus Forceps_.--Foreign bodies rarely lodge in an
upper-lobe bronchus, yet with such a problem it is necessary to have
forceps that will reach around a corner. The upper-lobe-bronchus
forceps shown in Fig. 27 have curved jaws so made as to straighten out
while passing through the bronchoscope and to spring back into their
original shape on up from the lower jaw emerging from the distal end
of the bronchoscopic tube, the radius of curvature being regulated by
the extent of emergence permitted. They are made in extra-light
pattern, 40 cm. long, and the regular model 45 cm. long. The
full-curved model, giving 180 degrees and reaching up into the
ascending branches, is made in both light and heavy patterns. Forceps
with less curve, and without the spiral, are used when it is desired
to reach only a short distance "around the corner" anywhere in the
bronchi. These are also useful, as suggested by Willis F. Manges, in
dealing with safety pins in the esophagus or tracheobronchial tree.
[FIG. 21.--Tucker jaws for the author's forceps. The tiny lip
projecting down from the upper, and up from the lower jaw prevents
sidewise escape of the shaft of a pin, tack, nail or needle. The shaft
is automatically thrown parallel to the bronchoscopic axis. Drawing
about four times actual size.]
[36] _Tucker Forceps_--Gabriel Tucker modified the regular side-curved
forceps by adding a lip (Fig. 21) to the left hand side of both upper
and lower jaws. This prevents the shaft of a tack, nail, or pin, from
springing out of the grasp of the jaws, and is so efficient that it
has brought certainty of grasp never before obtainable. With it the
solution of the safety-pin problem devised by the author many years
ago has a facility and certainty of execution that makes it the method
of choice in safety-pin extraction.
[FIG. 22.--The author's down-jaw esophageal forceps. The dropping jaw
is useful for reaching backward below the cricopharyngeal fold when
using the esophageal speculum in the removal of foreign bodies.
Posterior forceps-spaces are often scanty in cases of foreign bodies
lodged just below the cricopharyngeus.]
[FIG. 23.--Expansile forceps for the endoscopic removal of hollow
foreign bodies such as intubation tubes, tracheal cannulae, caps, and
cartridge shells.]
_Screw forceps_.--For the secure grasp of screws the jaws devised by
Dr. Tucker for tacks and pins are excellent (Fig. 21).
_Expanding Forceps_.--Hollow objects may require expanding
forceps as shown in Fig. 23. In using them it is necessary to be
certain that the jaws are inside the hollow body before expanding them
and making traction. Otherwise severe, even fatal, trauma may be
inflicted.
[FIG. 24.--The author's fenestrated peanut forceps. The delicate
construction with long, springy and fenestrated jaws give in gentle
hands a maximum security with a minimum of crushing tendency.]
[FIG. 25--The author's bronchial dilators, useful for dilating
strictures above foreign bodies. The smaller size, shown at the right
is also useful as an expanding forceps for removing intubation tubes,
and other hollow objects. The larger size will go over the shaft of a
tack.]
[FIG. 26.--The author's self-expanding bronchial dilator. The extent of
expansion can be limited by the sense of touch or by an adjustable
checking mechanism on the handle. The author frequently used smooth
forceps for this purpose, and found them so efficient that this
dilator was devised. The edges of forceps jaws are likely to scratch
the epithelium. Occasionally the instrument is useful in the
esophagus; but it is not very safe, unless used with the utmost
caution.]
_Tissue Forceps_.--With the forceps illustrated in Fig. 28 specimens
of tissue may be removed for biopsy from the lower air and food
passages with ease and certainty. They have a cross in the outer blade
which holds the specimen removed. The action is very delicate, there
being no springs, and the sense of touch imparted is often of great
aid in the diagnosis.
[FIG. 27.--The author's upper-lobe bronchus forceps. At A is shown
the full-curved form, for reaching into the ascending branches of the
upper-lobe bronchus A number of different forms of jaws are made in
this kind of forceps. Only 2 are shown.]
[FIG 28--The author's endoscopic tissue forceps. The laryngeal length
is 30 cm. For esophageal use they are made 50 and 60 cm. long. These
are the best forceps for cutting out small specimens of tissue for
biopsy.]
The large basket punch forceps shown in Fig. 33 are useful in removing
larger growths or specimens of tissue from the pharynx or larynx. A
portion or the whole of the epiglottis may be easily and quickly
removed with these forceps, the laryngoscope introduced along the
dorsum of the tongue into the glossoepiglottic recess, bringing the
whole epiglottis into view. The forceps may be introduced through the
laryngoscope or alongside the tube. In the latter method a greater
lateral action of the forceps is obtainable, the tube being used for
vision only. These forceps are 30 cm. long and are made in two sizes;
one with the punch of the largest size that can be passed through the
adult laryngoscope, and a smaller one for use through the
anterior-commissure laryngoscope and the child's size laryngoscope.
[FIG. 29.--The author's papilloma forceps. The broad blunt nose will
scalp off the growths without any injury to the normal basal tissues.
Voice-destroying and stenosing trauma are thus easily avoided.]
[FIG. 30.--The author's short mechanical spoon (30 cm. long).]
_Papilloma Forceps_.--Papillomata do not infiltrate; but superficial
repullulations in many cases require repeated removals. If the basal
tissues are traumatized, an impaired or ruined voice will result. The
author designed these forceps (Fig. 29) to scalp off the growths
without injury to the normal tissues.
[FIG. 31.--The author's laryngeal rotation forceps.]
[FIG. 32.--Enlarged view of the jaws of the author's vocal-nodule
forceps. Larger cups are made for other purposes but these tiny cups
permit of that extreme delicacy required in the excision of the
nodules from the vocal cords of singers and other voice users.]
[FIG 33.-Extra large laryngeal tissue forceps. 30 cm. long, for
removing entire growths or large specimens of tissue. A smaller size
is made.]
_Bronchial Dilators_.--It is not uncommon to find a stricture of the
bronchus superjacent to a foreign body that has been in situ for a
period of months. In order to remove the foreign body, this stricture
must be dilated, and for this the bronchial dilator shown in Fig. 25
was devised. The channel in each blade allows the closed dilator to be
pushed down over the presenting point of such bodies as tacks, after
which the blades are opened and the stricture stretched. A small and a
large size are made. For enlarging the bronchial narrowing associated
with pulmonary abscess and sometimes found above a bronchiectatic or
foreign body cavity, the expanding dilator shown in Fig. 26 is perhaps
less apt to cause injury than ordinary forceps used in the same way.
The stretching is here produced by the spring of the blades of the
forceps and not by manual force. The closed blades are to be inserted
through the strictured area, opened, and then slowly withdrawn. For
cicatricial stenoses of the trachea the metallic bougies, Fig. 40, are
useful. For the larynx, those shown in Fig. 41 are needed.
[FIG. 34.--A, Mosher's laryngeal curette; B, author's flat blade
cautery electrode; C, pointed cautery electrode; D, laryngeal knife.
The electrodes are insulated with hard-rubber vulcanized onto the
conducting wires.]
[FIG. 35.--Retrograde esophageal bougies in graduated sizes devised by
Dr. Gabriel Tucker and the author for dilatation of cicatricial
esophageal stenosis. They are drawn upward by an endless swallowed
string, and are therefore only to be used in gastrostomized cases.]
[FIG. 36.--Author's bronchoscopic and esophagoscopic mechanical spoon,
made in 40, 50 and 60 cm. lengths.]
[FIG. 37.--Schema illustrating the author's method of endoscopic
closure of open safety pins lodged point upward The closer is passed
down under ocular control until the ring, R, is below the pin. The
ring is then erected to the position shown dotted at M, by moving the
handle, H, downward to L and locking it there with the latch, Z. The
fork, A, is then inserted and, engaging the pin at the spring loop, K,
the pin is pushed into the ring, thus closing the pin. Slight rotation
of the pin with the forceps may be necessary to get the point into the
keeper. The upper instrument is sometimes useful as a mechanical spoon
for removing large, smooth foreign bodies from the esophagus.]
_Esophageal Dilators_.--The dilatation of cicatricial stenosis of the
esophagus can be done safely only by endoscopic methods. Blind
esophageal bouginage is highly dangerous, for the lumen of the
stricture is usually eccentric and the bougie is therefore apt to
perforate the wall rather than find the small opening. Often there is
present a pouching of the esophagus above a stricture, in which the
bougie may lodge and perforate. Bougies should be introduced under
visual guidance through the esophagoscope, which is so placed that the
lumen of the stricture is in the center of the endoscopic field. The
author's endoscopic bougies (Fig. 40) are made with a flexible
silk-woven tip securely fastened to a steel shaft. This shaft lends
rigidity to the instrument sufficient to permit its accurate
placement, and its small size permits the eye to keep the silk-woven
tip in view. These endoscopic bougies are made in sizes from 8 to 40,
French scale. The larger sizes are used especially for the dilatation
of laryngeal and tracheal stenoses. For the latter work it is
essential that the bougies be inspected carefully before they are
used, for should a defective tip come off while in the lower air
passages a difficult foreign body problem would be created.
Soft-rubber retrograde dilators to be drawn upward from the stomach by
a swallowed string are useful in gastrostomized cases (Fig. 35).
[FIG 38.--Half curved hook, 45 cm. and 60 cm. Full curved patterns are
made but caution is necessary to avoid them becoming anchored in the
bronchi. Spiral forms avoid this. The author makes for himself steel
probe-pointed rods out of which he bends hooks of any desired shape.
The rod is held in a pin-vise to facilitate bending of the point,
after heating in an alcohol or bunsen flame.]
_Hooks_.--No hook greater than a right angle should be used through
endoscopic tubes; for should it become caught in some of the smaller
bronchi its extraction might result in serious trauma. The half curved
hook shown in Fig. 38 is the safest type; better still, a spiral twist
to the hook will add to its uses, and by reversing the turning motion
it may be "unscrewed" out if it becomes caught. Hooks may easily be
made from rods of malleable steel by heating the end in a spirit lamp
and shaping the curve as desired by means of a pin-vise and pliers.
About 2 cm. of the proximal end of the rod should be bent in exactly
the opposite direction from that of the hook so as to form a handle
which will tell the position of the hook by touch as well as by sight.
Coil-spring hooks for the upper-lobe-bronchus (Fig. 39) will reach
around the corner into the ascending bronchus of the
upper-lobe-bronchus, but the utmost skill and care are required to
make their use justifiable.
[FIG. 39.--Author's coil-spring hook for the upper-lobe, bronchus]
_Safety-pin Closer_.--There are a number of methods for the endoscopic
removal of open safety-pins when the point is up, one of which is by
closing the pin with the instrument shown in Fig. 37 in the following
manner. The oval ring is passed through the endoscope until it is
beyond the spring of the safety-pin, the ring is then turned upward by
depressing the handle, and by the aid of the prong the pin is pushed
into the ring, which action approximates the point of the pin and the
keeper and closes the pin. Removal is then less difficult and without
danger. This instrument may also be used as a mechanical spoon, in
which case it may be passed to the side of a difficultly grasped
foreign body, such as a pebble, the ring elevated and the object
withdrawn. Elsewhere will be found a description of the
various safety-pin closers devised by various endoscopists. The author
has used Arrowsmith's closer with much satisfaction.
_Mechanical Spoon_.--When soft, friable substances, such as a bolus of
meat, become impacted in the upper esophagus, the short mechanical
spoon (Fig. 30) used through the esophageal speculum is of great aid
in their removal. The blade in this instrument, as the name suggests,
is a spoon and is not fenestrated as is the safety-pin closer, which
if used for friable substances would allow them to slip through the
fenestration. A longer form for use through bronchoscopes and
esophagoscopes is shown in Fig. 36.
A laryngeal curette, cautery electrodes, cautery handle, and laryngeal
knife are illustrated in Fig. 34. The cautery is to be used with a
transformer, or a storage battery.
_Spectacles_.--If the operator has no refractive error he will need
two pairs of plane protective spectacles with very large "eyes." If
ametropic, corrective lenses are necessary, and duplicate spectacles
must be in charge of a nurse. For presbyopia two pairs of spectacles
for 40 cm. distance and 65 cm. distance must be at hand. Hook temple
frames should be used so that they can be easily changed and adjusted
by the nurse when the lenses become spattered. The spectacle nurse has
ready at all times the extra spectacles, cleaned and warmed in a pan
of heated water so that they will not be fogged by the patient's
breath, and she changes them without delay as often as they become
soiled. The operator should work with both eyes open and with his
right eye at the tube mouth. The operating room should be somewhat
darkened so as to facilitate the ignoring of the image in the left
eye; any lighting should be at the operator's back, and should be
insufficient to cause reflections from the inner surface of his
glasses.
[FIG. 40.--The author's endoscopic bougies. The end consists of a
flexible silk woven tip attached securely to a steel shank. Sizes 8 to
30 French catheter scale. A metallic form of this bougie is useful in
the trachea; but is not so safe for esophageal use.]
[FIG. 41.--The author's laryngeal bougie for the dilatation of
cicatricial laryngeal stenosis. Made in 10 sizes. The shaded triangle
shows the cross-section at the widest part.]
[FIG. 42.--The author's bronchoscopic and esophagoscopic table.]
[46] _Endoscopic Table_.--Any operating table may be used, but the
work is facilitated if a special table can be had which allows the
placing of the patient in all required positions. The table
illustrated in fig. 42 is so arranged that when the false top is drawn
forward on the railroad, the head piece drops and the patient is
placed in the correct (Boyce) position for esophagoscopy or
bronchoscopy, i.e., with the head and shoulders extending over the end
of the table. By means of the wheel the plane of the table may
be altered to any desired angle of inclination or height of head.
_Operating Room_.--All endoscopic procedures should be performed in a
somewhat darkened operating room where all the desired materials are
at hand. An endoscopic team consists of three persons: the operator,
the assistant who holds the head, and the instrument assistant.
Another person is required to hold the patient's arms and still
another for the changing of the operator's glasses when they become
spattered. The endoscopic team of three maintain surgical asepsis in
the matter of hands and gowns, etc. The battery, on a small table of
its own, is placed at the left hand of the operator. Beyond it is the
table for the mechanical aspirator, if one is used. All extra
instruments are placed on a sterile table, within reach, but not in
the way, while those instruments for use in the particular operation
are placed on a small instrument table back of the endoscopist. Only
those instruments likely to be wanted should be placed on the working
table, so that there shall be no confusion in their selection by the
instrument nurse when called for. Each moment of time should be
utilized when the endoscopic procedure has been started, no time
should be lost in the hunting or separating of instruments. To have
the respective tables always in the same position relative to the
operator prevents confusion and avoids delay.
[FIG 43.--The author's retrograde esophagoscope.]
_Oxygen Tank and Tracheotomy Instruments_.--Respiratory arrest may
occur from shifting of a foreign body, pressure of the esophagoscope,
tumor, or diverticulum full of food. Rare as these contingencies are,
it is essential that means for resuscitation be at hand. No endoscopic
procedure should be undertaken without a set of tracheotomy
instruments on the sterile table within instant reach. In respiratory
arrest from the above mentioned causes, respiratory efforts are not
apt to return unless oxygen and amyl nitrite are blown into the
trachea either through a tracheotomy opening or better still by means
of a bronchoscope introduced through the larynx. The limpness of the
patient renders bronchoscopy so easy that the well-drilled
bronchoscopist should have no difficulty in inserting a bronchoscope
in 10 or 15 seconds, if proper preparedness has been observed. It is
perhaps relatively rarely that such accidents occur, yet if
preparations are made for such a contingency, a life may be saved
which would otherwise be inevitably lost. The oxygen tank covered with
a sterile muslin cover should stand to the left of the operating
table.
_Asepsis_.--Strict aseptic technic must be observed in all endoscopic
procedures. The operator, first assistant, and instrument nurse must
use the same precautions as to hand sterilization and sterile gowns as
would be exercised in any surgical operation. The operator and first
assistant should wear masks and sterile gloves. The patient is
instructed to cleanse the mouth thoroughly with the tooth brush and a
20 per cent alcohol mouth wash. Any dental defects should, if time
permit, as in a course of repeated treatments, be remedied by the
dental surgeon. When placed on the table with neck bare and the
shoulders unhampered by clothing, the patient is covered with a
sterile sheet and the head is enfolded in a sterile towel. The face is
wiped with 70 per cent alcohol.
It is to be remembered that while the patient is relatively immune to
the bacteria he himself harbors, the implantation of different strains
of perhaps the same type of organisms may prove virulent to him.
Furthermore the transference of lues, tuberculosis, diphtheria,
pneumonia, erysipelas and other infective diseases would be inevitable
if sterile precautions were not taken.
All of the tubes and forceps are sterilized by boiling. The
light-carriers and lamps may be sterilized by immersion in 95 per cent
alcohol or by prolonged exposure to formaldehyde gas. Continuous
sterilization by keeping them put away in a metal box with formalin
pastilles or other source of formaldehyde gas is an ideal method.
Knives and scissors are immersed in 95 per cent alcohol, and the
rubber covered conducting cords are wiped with the same solution.
_List of Instruments_.--The following list has been compiled as a
convenient basis for equipment, to which such special instruments as
may be needed for special cases can be added from time to time. The
instruments listed are of the author's design.
1 adult's laryngoscope.
1 child's laryngoscope.
1 infant's diagnostic laryngoscope.
1 anterior commissure laryngoscope.
1 bronchoscope, 4 mm. X 30 cm.
1 bronchoscope, 5 mm. X 30 cm.
1 bronchoscope, 7 mm. X 40 cm.
1 bronchoscope, 9 mm. X 40 cm.
1 esophagoscope, 7 mm. X 45 cm.
1 esophagoscope, 10 mm. X 53 cm.
1 esophagoscope, full lumen, 7 mm. X 45 cm.
1 esophagoscope, full lumen, 9 mm. X 45 cm.
1 esophageal speculum, adult.
1 esophageal speculum, child.
1 forward-grasping forceps, delicate, 40 cm.
1 forward-grasping forceps, regular, 50 cm.
1 forward-grasping forceps, regular, 60 cm.
1 side-grasping forceps, delicate, 40 cm.
1 side-grasping forceps, regular, 50 cm.
1 side-grasping forceps, regular, 60 cm.
1 rotation forceps, delicate, 40 cm.
1 rotation forceps, regular, 50 cm.
1 rotation forceps, regular, 60 cm.
1 laryngeal alligator forceps.
1 laryngeal papilloma forceps.
10 esophageal bougies, Nos. 8 to 17 French (larger sizes to No. 36
may be added).
1 special measuring rule.
6 light sponge carriers.
1 aspirator with double tube for minus and plus pressure.
2 endoscopic aspirating tubes 30 and 50 cm.
1 half curved hook, 60 cm.
1 triple circuit bronchoscopy battery.
6 rubber covered conducting cords for battery.
1 box bronchoscopic sponges, size 4.
1 box bronchoscopic sponges, size 5.
1 box bronchoscopic sponges, size 7.
1 box bronchoscopic sponges, size 10.
1 bite block, 1 adult.
1 bite block, child.
2 dozen extra lamps for lighted instruments.
1 extra light carrier for each instrument.*
4 yards of pipe-cleaning, worsted-covered wire.
[* Messrs. George P. Pilling and Sons who are now making these
instruments supply an extra light carrier and 2 extra lamps with each
instrument.]
_Care of Instruments_.--The endoscopist must either personally care
for his instruments, or have an instrument nurse in his own employ,
for if they are intrusted to the general operating room routine he
will find that small parts will be lost; blades of forceps bent,
broken, or rusted; tubes dinged; drainage canals choked with blood or
secretions which have been coagulated by boiling, and electric
attachments rendered unstable or unservicable, by boiling, etc. The
tubes should be cleansed by forcing cold water through the drainage
canals with the aspirating syringe, then dried by forcing
pipe-cleaning worsted-covered wire through the light and drainage
canals. Gauze on a sponge carrier is used to clean the main canal.
Forceps stylets should be removed from their cannulae, and the
cannulae cleansed with cold water, then dried and oiled with the
pipe-cleaning material. The stylet should have any rough places
smoothed with fine emery cloth and its blades carefully inspected; the
parts are then oiled and reassembled. Nickle plating on the tubes is
apt to peel and these scales have sharp, cutting edges which may
injure the mucosa. All tubes, therefore, should be unplated. Rough
places on the tubes should be smoothed with the finest emery cloth,
or, better, on a buffing wheel. The dry cells in the battery should be
renewed about every 4 months whether used or not. Lamps, light
carriers, and cords, after cleansing, are wiped with 95 per cent
alcohol, and the light-carriers with the lamps in place are kept in a
continuous sterilization box containing formaldehyde pastilles. It is
of the utmost importance that instruments be always put away in
perfect order. Not only are cleaning and oiling imperative, but any
needed repairs should be attended to at once. Otherwise it will be
inevitable that when gotten out in an emergency they will fail. In
general surgery, a spoon will serve for a retractor and good work can
be done with makeshifts; but in endoscopy, especially in the small,
delicate, natural passages of children, the handicap of a defective or
insufficient armamentarium may make all the difference between a
success and a fatal failure.
A bronchoscopic clinic should at all times be in the same state of
preparedness for emergency as is everywhere required of a fire-engine
house.
[PLATE I--A WORKING SET OF THE AUTHOR'S ENDOSCOPIC TUBES FOR LARYNGOSCOPY,
BRONCHOSCOPY, ESOPHAGOSCOPY, AND GASTROSCOPY:
A, Adult's laryngoscope; B, child's laryngoscope; C, anterior
commissure laryngoscope; D, esophageal speculum, child's size; E,
esophageal speculum, adult's size; F, bronchoscope, infant's size, 4
mm. X 30 cm.; G, bronchoscope, child's size, 5 mm. X 30 cm.; H,
aspirating bronchoscope for adults, 7 mm. X 40 cm.; I, bronchoscope,
adolescent's size, 7 mm. x 40 cm., used also for the deeper bronchi of
adults; J, bronchoscope, adult size, g mm. x 40 cm.; K, child's size
esophagoscope, 7 mm. X 45 cm.; L, adult's size esophagoscope, full
lumen construction, 9 mm. x 45 cm.; M, adult's size gastroscope. C,
I, and E are also hypopharyngoscopes. C is an excellent esophageal
speculum for children, and a longer model is made for adults.
If the utmost economy must be practised D, E, and M may be omitted.
The balance of the instruments are indispensable if adults and
children are to be dealt with. The instruments are made by Charles J.
Pilling & Sons, Philadelphia.]
[52] CHAPTER II--ANATOMY OF LARYNX, TRACHEA, BRONCHI AND ESOPHAGUS,
ENDOSCOPICALLY CONSIDERED
The _larynx_ is a cartilaginous box, triangular in cross-section, with
the apex of the triangle directed anteriorly. It is readily felt in
the neck and is a landmark for the operation of tracheotomy. We are
concerned endoscopically with four of its cartilaginous structures:
the epiglottis, the two arytenoid cartilages, and the cricoid
cartilage. The _epiglottis_, the first landmark in direct
laryngoscopy, is a leaf-like projection springing from the
anterointernal surface of the larynx and having for its function the
directing of the bolus of food into the pyriform sinuses. It does not
close the larynx in the trap-door manner formerly taught; a fact
easily demonstrated by the simple insertion of the direct laryngoscope
and further demonstrated by the absence of dysphagia when the
epiglottis is surgically removed, or is destroyed by ulceration.
Closure of the larynx is accomplished by the approximation of the
ventricular bands, arytenoids and aryepiglottic folds, the latter
having a sphincter-like action, and by the raising and tilting of the
larynx. The _arytenoids_ form the upper posterior boundary of the
larynx and our particular interest in them is directed toward their
motility, for the rotation of the arytenoids at the cricoarytenoid
articulations determines the movements of the cords and the production
of voice. Approximation of the arytenoids is a part of the mechanism
of closure of the larynx.
The _cricoid cartilage_ was regarded by esophagoscopists as the chief
obstruction encountered on the introduction of the esophagoscope. As
shown by the author, it is the cricopharyngeal fold, and the
inconceivably powerful pull of the cricopharyngeal muscle on the
cricoid cartilage, that causes the difficulty. The cricoid is pulled
so powerfully back against the cervical spine, that it is hard to
believe that this muscles is inserted into the median raphe and not
into the spine itself (Fig. 68).
The _ventricular bands_ or false vocal cords vicariously phonate in
the absence of the true cords, and assist in the protective function
of the larynx. They form the floor of the _ventricles_ of the larynx,
which are recesses on either side, between the false and true cords,
and contain numerous mucous glands the secretion from which lubricates
the cords. The ventricles are not visible by mirror laryngoscopy, but
are readily exposed in their depths by lifting the respective
ventricular bands with the tip of the laryngoscope. The _vocal cords_,
which appear white, flat, and ribbon-like in the mirror, when viewed
directly assume a reddish color, and reveal their true shelf-like
formation. In the subglottic area the tissues are vascular, and, in
children especially, they are prone to swell when traumatized, a fact
which should be always in mind to emphasize the importance of
gentleness in bronchoscopy, and furthermore, the necessity of avoiding
this region in tracheotomy because of the danger of producing chronic
laryngeal stenosis by the reaction of these tissues to the presence of
the tracheotomic cannula.
The _trachea_ just below its entrance into the thorax deviates
slightly to the right, to allow room for the aorta. At the level of
the second costal cartilage, the third in children, it bifurcates into
the right and left main bronchi. Posteriorly the bifurcation
corresponds to about the fourth or fifth thoracic vertebra, the
trachea being elastic, and displaced by various movements. The
endoscopic appearance of the trachea is that of a tube flattened on
its posterior wall. In two locations it normally often assumes a more
or less oval outline; in the cervical region, due to pressure of the
thyroid gland; and in the intrathoracic portion just above the
bifurcation where it is crossed by the aorta. This latter flattening
is rhythmically increased with each pulsation. Under pathological
conditions, the tracheal outline may be variously altered, even to
obliteration of the lumen. The mucosa of the trachea and bronchi is
moist and glistening, whitish in circular ridges corresponding to the
cartilaginous rings, and reddish in the intervening grooves.
The right bronchus is shorter, wider, and more nearly vertical than
its fellow of the opposite side, and is practically the continuation
of the trachea, while the left bronchus might be considered as a
branch. The deviation of the right main bronchus is about 25 degrees,
and its length unbranched in the adult is about 2.5 cm. The deviation
of the left main bronchus is about 75 degrees and its adult length is
about 5 cm. The right bronchus considered as a stem, may be said to
give off three branches, the epiarterial, upper- or superior-lobe
bronchus; the middle-lobe bronchus; and the continuation downward,
called the lower- or inferior-lobe bronchus, which gives off dorsal,
ventral and lateral branches. The left main bronchus gives off first
the upper-or superior-lobe bronchus, the continuation being the
lower-or inferior-lobe bronchus, consisting of a stem with dorsal,
ventral and lateral branches.
[FIG. 44.--Tracheo-bronchial tree. LM, Left main bronchus; SL,
superior lobe bronchus; ML, middle lobe bronchus; IL, inferior lobe
bronchus.]
The septum between the right and left main bronchi, termed the carina,
is situated to the left of the midtracheal line. It is recognized
endoscopically as a short, shining ridge running sagitally, or, as the
patient lies in the recumbent position, we speak of it as being
vertical. On either side are seen the openings of the right and left
main bronchi. In Fig. 44, it will be seen that the lower border of the
carina is on a level with the upper portion of the orifice of the
right superior-lobe bronchus; with the carina as a landmark and by
displacing with the bronchoscope the lateral wall of the right main
bronchus, a second, smaller, vertical spur appears, and a view of the
orifice of the right upper-lobe bronchus is obtained, though a lumen
image cannot be presented. On passing down the right stem bronchus
(patient recumbent) a horizontal partition or spur is found with the
lumen of the middle-lobe bronchus extending toward the ventral surface
of the body. All below this opening of the right middle-lobe bronchus
constitutes the lower-lobe bronchus and its branches.
[FIG. 45.--Bronchoscopic views.
S; Superior lobe bronchus; SL, superior lobe bronchus; I, inferior
lobe bronchus; M, middle lobe bronchus.]
[56] Coming back to the carina and passing down the left bronchus, the
relatively great distance from the carina to the upper-lobe bronchus
is noted. The spur dividing the orifices of the left upper- and
lower-lobe bronchi is oblique in direction, and it is possible to see
more of the lumen of the left upper-lobe bronchus than of its
homologue on the right. Below this are seen the lower-lobe bronchus
and its divisions (Fig. 45).
_Dimensions of the Trachea and Bronchi_.--It will be noted that the
bronchi divide monopodially, not dichotomously. While the lumina of
the individual bronchi diminish as the bronchi divide, the sum of the
areas shows a progressive increase in total tubular area of
cross-section. Thus, the sum of the areas of cross-section of the two
main bronchi, right and left, is greater than the area of cross
section of the trachea. This follows the well known dynamic law. The
relative increase in surface as the tubes branch and diminish in size
increases the friction of the passing air, so that an actual increase
in area of cross section is necessary, to avoid increasing resistance
to the passage of air.
The cadaveric dimensions of the tracheobronchial tree may be
epitomized approximately as follows:
Adult
Male Female Child Infant
Diameter trachea, 14 X 20 12 X 16 8 X 10 6 X 7
Length trachea, cm. 12.0 10.0 6.0 4.0
Length right bronchus 2.5 2.5 2.0 1.5
Length left bronchus 5.0 5.0 3.0 2.5
Length upper teeth to trachea 15.0 23.0 10.0 9.0
Length total to secondary bronchus 32.0 28.0 19.0 15.0
In considering the foregoing table it is to be remembered that in life
muscle tonus varies the lumen and on the whole renders it smaller. In
the selection of tubes it must be remembered that the full diameter of
the trachea is not available on account of the glottic aperture which
in the adult is a triangle measuring approximately 12 X 22 X 22 mm.
and permitting the passage of a tube not over 10 mm. in diameter
without risk of injury. Furthermore a tube which filled the trachea
would be too large to enter either main bronchus.
The normal movements of the trachea and bronchi are respiratory,
pulsatory, bechic, and deglutitory. The two former are rhythmic while
the two latter are intermittently noted during bronchoscopy. It is
readily observed that the bronchi elongate and expand during
inspiration while during expiration they shorten and contract. The
bronchoscopist must learn to work in spite of the fact that the
bronchi dilate, contract, elongate, shorten, kink, and are dinged and
pushed this way and that. It is this resiliency and movability that
make bronchoscopy possible. The inspiratory enlargement of lumen opens
up the forceps spaces, and the facile bronchoscopist avails himself of
the opportunity to seize the foreign body.
THE ESOPHAGUS
A few of the anatomical details must be kept especially in mind when
it is desired to introduce straight and rigid instruments down the
lumen of the gullet. First and most important is the fact that the
esophageal walls are exceedingly thin and delicate and require the
most careful manipulation. Because of this delicacy of the walls and
because the esophagus, being a constant passageway for bacteria from
the mouth to the stomach, is never sterile, surgical procedures are
associated with infective risks. For some other and not fully
understood reason, the esophagus is, surgically speaking, one of the
most intolerant of all human viscera. The anterior wall of the
esophagus is in a part of its course, in close relation to the
posterior wall of the trachea, and this portion is called the party
wall. It is this party wall that contains the lymph drainage system of
the posterior portion of the larynx, and it is largely by this route
that posteriorly located malignant laryngeal neoplasms early
metastasize to the mediastinum.
[58] [FIG 46.--Esophagoscopic and Gastroscopic Chart
BIRTH 1 yr. 3 yrs. 6 yrs. 10 yrs. 14 yrs.ADULTS
23 27 30 33 36 43 53 Cm. GREATER CURVATURE
18 20 22 25 27 34 40 Cm. CARDIA
19 21 23 24 25 31 36 Cm. HIATUS
13 15 16 18 20 24 27 Cm. LEFT BRONCHUS
12 14 15 16 17 21 23 Cm. AORTA
7 9 10 11 12 14 16 Cm. CRICOPHARYINGEUS
0 0 0 0 0 0 0 Cm. INCISORS
FIG. 46.--The author's esophagoscopic chart of approximate distances
of the esophageal narrowings from the upper incisor teeth, arranged
for convenient reference during esophagoscopy in the dorsally
recumbent patient.]
The lengths of the esophagus at different ages are shown
diagrammatically in Fig. 46. The diameter of the esophageal lumen
varies greatly with the elasticity of the esophageal walls; its
diameter at the four points of anatomical constriction is shown in the
following table:
Constriction Diameter Vertebra
Cricopharyngeal Transverse 23 mm. (1 in.) Sixth cervical
Antero-posterior 17 mm. (3/4 in.)
Aortic Transverse 24 mm. (1 in.) Fourth thoracic
Antero-posterior 19 mm. (3/4 in.)
Left-bronchial Transverse 23 mm. (1 in.) Fifth thoracic
Antero-posterior 17 mm. (3/4 in.)
Diaphragmatic Transverse 23 mm. (1 in+) Tenth thoracic
Antero-posterior 23 mm. (in.--)
For practical endoscopic purposes it is only necessary to remember
that in a normal esophagus, straight and rigid tubes of 7 mm. diameter
should pass freely in infants, and in adults, tubes of 10 mm.
The 4 demonstrable constrictions from above downward are at
1. The crico-pharyngeal fold.
2. The crossing of the aorta.
3. The crossing of the left bronchus.
4. The hiatus esophageus.
There is a definite fifth narrowing of the esophageal lumen not easily
demonstrated esophagoscopically and not seen during dissection, but
readily shown functionally by the fact that almost all foreign bodies
lodge at this point. This narrowing occurs at the superior aperture of
the thorax and is probably produced by the crowding of the numerous
organs which enter or leave the thorax through this orifice.
_The crico-pharyngeal constriction_, as already mentioned, is produced
by the tonic contraction of a specialized band of the orbicular fibers
of the lowermost portion of the inferior pharyngeal constrictor
muscle, called the cricopharyngeal muscle. As shown by the author it
is this muscle and not the cricoid cartilage alone that causes the
difficulty in the insertion of an esophagoscope.
This muscle is attached laterally to the edges of the signet of the
cricoid which it pulls with an incomprehensible power against the
posterior wall of the hypopharynx, thus closing the mouth of the
esophagus. Its other attachment is in the median posterior raphe.
Between these circular fibers (the cricopharyngeal muscle) and the
oblique fibers of the inferior constrictor muscle there is a weakly
supported point through which the esophageal wall may herniate to form
the so-called pulsion diverticulum. It is at this weak point that
fatal esophagoscopic perforation by inexperienced operators is most
likely to occur.
_The aortic narrowing_ of the esophagus may not be noticed at all if
the patient is placed in the proper sequential "high-low" position. It
is only when the tube-mouth is directed against the left anterior wall
that the actively pulsating aorta is felt.
The bronchial narrowing of the esophagus is due to backward
displacement caused by the passage of the left bronchus over the
anterior wall of the esophagus at about 27 cm. from the upper teeth in
the adult. The ridge is quite prominent in some patients, especially
those with dilatation from stenoses lower down.
The hiatal narrowing is both anatomic and spasmodic. The peculiar
arrangement of the tendinous and muscular structure of the diaphragm
acts on this hiatal opening in a sphincter-like fashion. There are
also special bundles of muscle fibers extending from the crura of the
diaphragm and surrounding the esophagus, which contribute to tonic
closure in the same way that a pinch-cock closes a rubber tube. The
author has called the hiatal closure the "diaphragmatic pinchcock."
_Direction of the Esophagus_.--The esophagus enters the chest in a
decidedly backward as well as downward direction, parallel to that of
the trachea, following the curves of the cervical and upper dorsal
spine. Below the left bronchus the esophagus turns forward, passing
through the hiatus in the diaphragm anterior to and to the left of the
aorta. The lower third of the esophagus in addition to its anterior
curvature turns strongly to the left, so that an esophagoscope
inserted from the right angle of the mouth, when introduced into the
stomach, points in the direction of the anterior superior spine of the
left ileum.
It is necessary to keep this general course constantly in mind in all
cases of esophagoscopy, but particularly in those cases in which there
is marked dilatation of the esophagus following spasm at the diaphragm
level. In such cases the aid of this knowledge of direction will
greatly simplify the finding of the hiatus esophageus in the floor of
the dilatation.
The extrinsic or transmitted movements of the esophagus are
respiratory and pulsatory, and to a slight extent, bechic. The
respiratory movements consist in a dilatation or opening up of the
thoracic esophageal lumen during inspiration, due to the negative
intrathoracic pressure. The normal pulsatory movements are due to the
pulsatile pressure of the aorta, found at the 4th thoracic vertebra
(24 cm. from the upper teeth in the adult), and of the heart itself,
most markedly felt at the level of the 7th and 8th thoracic vertebrae
(about 30 cm. from the upper teeth in adults). As the distances of all
the narrowings vary with age, it is useful to frame and hang up for
reference a copy of the chart (Fig. 46).
The intrinsic movements of the esophagus are involuntary muscular
contractions, as in deglutition and regurgitation; spasmodic, the
latter usually having some pathologic cause; and tonic, as the normal
hiatal closure, in the author's opinion may be considered. Swallowing
may be involuntary or voluntary. The constrictors are anatomically not
considered part of esophagus proper. When the constrictors voluntarily
deliver the bolus past the cricopharyngeal fold, the involuntary or
peristaltic contractions of the esophageal mural musculature carry the
bolus on downward. There is no sphincter at the cardiac end of the
esophagus. The site of spasmodic stenosis in the lower third, the
so-called cardiospasm, was first demonstrated by the author to be
located at the hiatus esophageus and the spasmodic contractions are of
the specialized muscle fibers there encircling the esophagus, and
might be termed "phrenospasm," or "hiatal esophagismus." Regurgitation
of food from the stomach is normally prevented by the hiatal muscular
diaphragmatic closure (called by the author the "diaphragmatic
pinchcock") plus the kinking of the abdominal esophagus.
In the author's opinion there is no spasm in the disease called
"cardiospasm." It is simply the failure of the diaphragmatic pinchcock
to open normally in the deglutitory cycle. A better name is functional
hiatal stenosis.
At retrograde esophagoscopy the cardia and abdominal esophagus do not
seem to exist. The top of the stomach seems to be closed by the
diaphragmatic pinchcock in the same way that the top of a bag is
closed by a puckering string.
[63] CHAPTER III--PREPARATION OF THE PATIENT FOR PERORAL ENDOSCOPY
The suggestions of the author in the earlier volumes in regard to
preparation of the patient, as for any operation, by a bath, laxative,
etc., and especially by special cleansing of the mouth with 25 per
cent alcohol, have received general endorsement. Care should be taken
not to set up undue reaction by vigorous scrubbing of gums
unaccustomed to it. Artificial dentures should be removed. Even if no
anesthetic is to be used, the patient should be fasted for five hours
if possible, even for direct laryngoscopy in order to forestall
vomiting. Except in emergency cases every patient should be gone over
by an internist for organic disease in any form. If an endolaryngeal
operation is needed by a nephritic, preparatory treatment may prevent
laryngeal edema or other complications. Hemophilia should be thought
of. It is quite common for the first symptom of an aortic aneurysm to
be an impaired power to swallow, or the lodgment of a bolus of meat or
other foreign body. If aneurysm is present and esophagoscopy is
necessary, as it always is in foreign body cases, "to be fore-warned
is to be forearmed." Pulmonary tuberculosis is often unsuspected in
very young children. There is great danger from tracheal pressure by
an esophageal diverticulum or dilatation distended with food; or the
food maybe regurgitated and aspirated into the larynx and trachea.
Therefore, in all esophageal cases the esophagus should be emptied by
regurgitation induced by titillating the fauces with the finger after
swallowing a tumblerful of water, pressure on the neck, etc. Aspiration
will succeed in some cases. In others it is absolutely necessary to
remove food with the esophagoscope. If the aspirating tube becomes
clogged by solid food, the method of swab aspiration mentioned under
bronchoscopy will succeed. Of course there is usually no cough to aid,
but the involuntary abdominal and thoracic compression helps. Should a
patient arrive in a serious state of water-hunger, as part of the
preparation the patient must be given water by hypodermoclysis and
enteroclysis, and if necessary the endoscopy, except in dyspneic
cases, must be delayed until the danger of water-starvation is past.
As pointed out by Ellen J. Patterson the size of the thymus gland
should be studied before an esophagoscopy is done on a child.
Every patient should be examined by indirect, mirror laryngoscopy as a
preliminary to peroral endoscopy for any purpose whatsoever. This
becomes doubly necessary in cases that are to be anesthetized.
[65] CHAPTER IV--ANESTHESIA FOR PERORAL ENDOSCOPY
A dyspneic patient should never be given a general anesthetic. Cocaine
should not be used on children under ten years of age because of its
extreme toxicity. To these two postulates always in mind, a third one,
applicable to both general and local anesthesia, is to be added--total
abolition of the cough-reflex should be for short periods only.
General anesthesia is never used in the Bronchoscopic Clinic for
endoscopic procedures. The choice for each operator must, however, be
a matter for individual decision, and will depend upon the personal
equation, and degree of skill of the operator, and his ability to
quiet the apprehensions of the patient. In other words, the operator
must decide what is best for his particular patient under the
conditions then existing.
_Children_ in the Bronchoscopic Clinic receive neither local nor
general anesthesia, nor sedative, for laryngoscopic operations or
esophagoscopy. Bronchoscopy in the older children when no dyspnea is
present has in recent years, at the suggestion of Prof. Hare, been
preceded by a full dose of morphin sulphate (i.e., 1/8 grain for a
child of six years) or a full physiologic dose of sodium bromide. The
apprehension is thus somewhat allayed and the excessive cough-reflex
quieted. The morphine should be given not less than an hour and a half
before bronchoscopy to allow time for the onset of the soporific and
antispasmodic effects which are the desiderata, not the analgesic
effects. Dosage is more dependent on temperament than on age or body
weight. Atropine is advantageously added to morphine in bronchoscopy
for foreign bodies, not only for the usual reasons but for its effect
as an antispasmodic, and especially for its diminution of
endobronchial secretions. True, it does not diminish pus, but by
diminishing the outpouring of normal secretions that dilute the pus
the total quantity of fluid encountered is less than it otherwise
would be. In cases of large quantities of pus, as in pulmonary abscess
and bronchiectasis, however, no diminution is noticeable. No food or
water is allowed for 5 hours prior to any endoscopic procedure,
whether sedatives or anesthetics are to be given or not. If the
stomach is not empty vomiting from contact of the tube in the pharynx
will interfere with work.
With _adults_ no anesthesia, general or local, is given for
esophagoscopy. For laryngeal operation and bronchoscopy the following
technic is used:
One hour before operation the patient is given hypodermatically a full
physiologic dose of morphin sulphate (from 1/4, to 3/8 gr.) guarded
with atropin sulphate (gr. 1/150). Care must be taken that the
injection be not given into a vein. On the operating table the
epiglottis and pharynx are painted with 10 per cent solution of
cocain. Two applications are usually sufficient completely to
anesthetize the exterior and interior of the larynx by blocking of the
superior laryngeal nerve without any endolaryngeal applications. The
laryngoscope is now introduced and if found necessary a 20 per cent
cocain solution is applied to the interior of the larynx and
subglottic region, by means of gauze swabs fastened to the sponge
carriers. Here also two applications are quite sufficient to produce
complete anesthesia in the larynx. If bronchoscopy is to be done the
gauze swab is carried down through the exposed glottis to the carina,
thus anesthetizing the tracheal mucosa. If further anesthetization of
the bronchial mucosa is required, cocain may be applied in the same
manner through the bronchoscope. In all these local applications
prolonged contact of the swab is much more efficient than simply
painting the surface.
[67] In cases in which cocain is deemed contraindicated morphin alone
is used. If given in sufficient dosage cocain can be altogether
dispensed with in any case.
It is perhaps _safer for the beginner_ in his early cases of
esophagoscopy to have the patient relaxed by an ether anesthesia,
provided the patient is not dyspneic to begin with, or made so by
faulty position or by pressure of the esophagoscopic tube mouth on the
tracheoesophageal "party wall." As proficiency develops, however, he
will find anesthesia unnecessary. Local anesthesia is needless for
esophagoscopy, and if used at all should be limited to the
laryngopharynx and never applied to the esophagus, for the esophagus
is without sensation, as anyone may observe in drinking hot liquids.
_Direct laryngoscopy in children_ requires neither local nor general
anesthesia, either for diagnosis or for removal of foreign bodies or
growths from the larynx. General anesthesia is contraindicated because
of the dyspnea apt to be present, and because the struggles of the
patient might cause a dislodgment of the laryngeal intruder and
aspiration to a lower level. The latter accident is also prone to
follow attempts to cocainize the larynx.
_Technic for General Anesthesia_.--For esophagoscopy and gastroscopy,
if general anesthesia is desired, ether may be started by the usual
method and continued by dropping upon folded gauze laid over the mouth
after the tube is introduced. Endo-tracheal administration of ether
is, however, far safer than peroral administration, for it overcomes
the danger of respiratory arrest from pressure of the esophagoscope,
foreign body, or both, on the trachea. Chloroform should not be used
for esophagoscopy or gastroscopy because of its depressant action on
the respiratory center.
For bronchoscopy, ether or chloroform may be started in the usual way
and continued by insufflating through the branch tube of the
bronchoscope by means of the apparatus shown in Fig. 13.
In case of paralysis of the larynx, even if only monolateral, a
general anesthetic if needed should be given by intratracheal
insufflation. If the apparatus for this is not available the patient
should be tracheotomized. Hence, every adult patient should be
examined with a throat mirror before general anesthesia for any
purpose, and the necessity becomes doubly imperative before goiter
operations. A number of fatalities have occurred from neglect of this
precaution.
_Anesthetizing a tracheotomized patient_ is free from danger so long
as
the cannula is kept free from secretion. Ether is dropped on gauze
laid over the tracheotomic cannula and the anesthesia watched in the
usual manner. If the laryngeal stenosis is not complete,
ether-saturated gauze is to be placed over the mouth as well as over
the tracheotomy tube.
_Endo-tracheal anesthesia_ is by far the safest way for the
administration of ether for any purpose. By means of the silk-woven
catheter introduced into the trachea, ether-laden air from an
insufflation apparatus is piped down to the lungs continuously, and
the strong return-flow prevents blood and secretions from entering the
lower air-passages. The catheter should be of a size, relative to that
of the glottic chink, to permit a free return-flow. A number 24 French
is readily accommodated by the adult larynx and lies well out of the
way along the posterior wall of the larynx. Because of the little room
occupied by the insufflation catheter this method affords ideal
anesthesia for external laryngeal operations. Operations on the nose,
accessory sinuses and the pharynx, apt to be attended by considerable
bleeding, are rendered free from the danger of aspiration pneumonia by
endotracheal anesthesia. It is the safest anesthesia for goiter
operations. Endo-tracheal anesthesia has rendered needless the
intricate negative pressure chamber formerly required for thoracic
surgery, for by proper regulation of the pressure under which the
ether ladened air is delivered, a lung may be held in any desired
degree of expansion when the pleural cavity is opened. It is indicated
in operations of the head, neck, or thorax, in which there is danger
of respiratory arrest by centric inhibition or peripheral pressure; in
operations in which there is a possibility of excessive bleeding and
aspiration of blood or secretions; and in operations where it is
desired to keep the anesthetist away from the operating field. Various
forms of apparatus for the delivery of the ether-laden vapor are
supplied by instrument makers with explicit directions as to their
mechanical management.
We are concerned here mainly with the technic of the insertion of the
intratracheal tube. The larynx should be examined with the mirror,
preferably before the day of operation, for evidence of disease, and
incidentally to determine the size of the catheter to be introduced,
though the latter can be determined after the larynx is
laryngoscopically exposed. The following list of rules for the
introduction of the catheter will be of service (see Fig. 59).
RULES FOR INSERTION OF THE CATHETER FOR INSUFFLATION
ANESTHESIA
1. The patient should be fully under the anesthetic by the open
method so as to get full relaxation of the muscles of the neck.
2. The patient's head must be in full extension with the vertex
firmly pushed down toward the feet of the patient, so as to throw the
neck upward and bring the occiput down as close as possible beneath
the cervical vertebrae.
3. No gag should be used, because the patient should be sufficiently
anesthetized not to need a gag, and because wide gagging defeats the
exposure of the larynx by jamming down the mandible.
4. The epiglottis must be identified before it is passed.
5. The speculum must pass sufficiently far below the tip of the
epiglottis so that the latter will not slip.
6. Too deep insertion must be avoided, as in this case the speculum
goes posterior to the cricoid, and the cricoid is lifted, exposing the
mouth of the esophagus, which is bewildering until sufficient
education of the eye enables the operator to recognize the landmarks.
7. The patient's head is lifted off the table by the spatular tip of
the laryngoscope. Actual lifting of the head will not be necessary if
the patient is fully relaxed; but the idea of lifting conveys the
proper conception of laryngeal exposure (Fig. 55).
[71] CHAPTER V--BRONCHOSCOPIC OXYGEN INSUFFLATION
Bronchoscopic oxygen insufflation is a life-saving measure equalled by
no other method known to the science of medicine, in all cases of
asphyxia, or apnea, present or impending. Its especial sphere of
usefulness is in severe cases of electric shock, hanging, smoke
asphyxia, strangulation, suffocation, thoracic or abdominal pressure,
apnea, acute traumatic pneumothorax, respiratory arrest from absence
of sufficient oxygen, or apnea from the presence of quantities of
irrespirable or irritant gases. Combined with bronchoscopic aspiration
of secretions it is the best method of treatment for poisoning by
chlorine gas, asphyxiating, and other war gases.
Bronchoscopic oxygen insufflation should be taught to every interne in
every hospital. The emergency or accident ward of every hospital
should have the necessary equipment and an interne familiar with its
use. The method is simple, once the knack is acquired. The patient
being limp and recumbent on a table, the larynx is exposed with the
laryngoscope, and the bronchoscope is inserted as hereinafter
described. The oxygen is turned on at the tank and the flow regulated
before the rubber tube from the wash-bottle of tank is attached to the
side-outlet of the bronchoscope. It is necessary to be certain that
the flow is gentle, so that, with a free return flow the introduced
pressure does not exceed the capillary pressure; otherwise the blood
will be forced out of the capillaries and the ischemia of the lungs
will be fatal. Another danger is that overdistension causes inhibition
of inspiration resulting in apnea continuing as long as the distension
is maintained, if not longer. The return flow from the bronchoscope
should be interrupted for 2 or 3 seconds several times a minute to
inflate the lungs, but the flow must not be occluded longer than 3
seconds, because the intrapulmonary pressure would rise. A pearl of
amyl nitrite may be broken in the wash bottle. Slow rhythmic
artificial respiratory movements are a useful adjunct, and unless the
operator is very skillful in gauging the alternate pressures and
releases with the thumb according to the oxygen pressure, it is
vitally necessary to fill and deflate the lungs rhythmically by one of
the well known methods of artificial respiration. Anyone skilled in
the introduction of the bronchoscope can do bronchoscopy in a few
seconds, and it is especially easy in cases of respiratory arrest,
because of the limp condition of the patient.
The foregoing applies to cases in which a pulmotor would be used, such
as apnea from electric shocks, etc. For obstructive dyspnea and
asphyxia, tracheotomy is the procedure of choice, and the skillful
tracheotomist would be justified in preferring tracheotomy for the
other class of cases, insufflating the oxygen and amyl nitrite through
the tracheotomic wound. The pulmotor and similar mechanisms are,
perhaps, the best things the use of which can be taught to laymen; but
as compared to bronchoscopic oxygen insufflation they are woefully
inefficient, because the intraoral pressure forces the tongue back
over the laryngeal orifice, obstructing the airway in this "death
zone." By the introduction of the bronchoscope this death zone is
entirely eliminated, and a free airway established for piping the
oxygen directly into the lungs.
[73] CHAPTER VI--POSITION OF THE PATIENT FOR PERORAL ENDOSCOPY
It is the author's invariable practice to place the patient in the
dorsally recumbent position. The sitting position is less favorable.
While lying on a well-padded, flat table the patient is readily
controlled, the head is freely movable, secretions can be easily
removed, the view obtained by the endoscopist is truly direct (without
reversal of sides), and, most important, the employment of one
position only favors smoother and more efficient team work, and a
better endoscopic technic.
_General Principles of Position_.--As will be seen in Fig. 47 the
trachea and esophagus are not horizontal in the thorax, but their long
axes follow the curves of the cervical and dorsal spine. Therefore, if
we are to bring the buccal cavity and pharynx in a straight line with
the trachea and esophagus it will be found necessary to elevate the
whole head above the plane of the table, and at the same time make
extension at the occipito-atloid joint. By this maneuver the cervical
spine is brought in line with the upper portion of the dorsal spine as
shown in Fig. 55. It was formerly taught, and often in spite of my
better knowledge I am still unconsciously prone to allow the head and
cervical spine to assume a lower position than the plane of the table,
the so-called Rose position. With the head so placed, it is impossible
to enter the lower air or food passages with a rigid tube, as will be
shown by a study of the radiograph shown in Fig. 49. Extension of the
head on the occipito-atloid joint is for the purpose of freeing the
tube from the teeth, and the amount required will vary with the degree
to which the mouth can be opened. Whether the head be extended,
flexed, or kept mid-way, the fundamental principle in the introduction
of all endoscopic tubes is the anterior placing of the cervical spine
and the high elevation of the head. The esophagus, just behind the
heart, turns ventrally and to the left. In order to pass a rigid tube
through this ventral curve the dorsal spine is now extended by
lowering the head and shoulders below the plane of the table. This
will be further explained in the chapter on esophagoscopy. In all of
these procedures, the nose of the patient should be directed toward
the zenith, and the assistant should _prevent rotation of the head_ as
well as _prevent lowering of the head_. The patient should be urged as
follows:
"Don't hold yourself so rigid."
"Let your head and neck go loose."
"Let your head rest in my hand."
"Don't try to hold it."
"Let me hold it."
"Relax."
"Don't raise your chest."
[FIG. 47.--Schematic illustration of normal position of the
intra-thoracic trachea and esophagus and also of the entire trachea
when the patient is in the correct position for peroral bronchoscopy.
When the head is thrown backward (as in the Rose position) the
anterior convexity of the cervical spine is transmitted to the trachea
and esophagus and their axes deviated. The anterior deviation of the
lower third of the esophagus shows the anatomical basis for the "high
low" position for esophagoscopy]
[FIG. 48.--Correct position of the cervical spine for esophagoscopy
and
bronchoscopy. (_Illustration reproduced from author's article Jour.
Am. Med. Assoc., Sept. 25, 1909_)]
[FIG. 49.--Curved position of the cervical spine, with anterior
convexity, in the Rose position, rendering esophagoscopy and
bronchoscopy difficult or impossible. The devious course of the
pharynx, larynx and trachea are plainly visible. The extension is
incorrectly imparted to the whole cervical spine instead of only to
the occipito-atloid joint. This is the usual and very faulty
conception of the extended position. (_Illustration reproduced from
author's article, Jour. Am. Med. Assoc., Sept. 25, 1909._)]
[76] For _direct laryngoscopy_ the patient's head is raised above the
plane of the table by the first assistant, who stands to the right of
the patient, holding the bite block on his right thumb inserted in the
left corner of the patient's mouth, while his extended right hand lies
along the left side of the patient's cheek and head, and prevents
rotation. His left hand, placed under the patient's occiput, elevates
the head and maintains the desired degree of extension at the
occipito-atloid joint (Fig. 50).
[FIG 50.--Direct laryngoscopy, recumbent patient. The second assistant
is sitting holding the head in the Boyce position, his left forearm on
his left thigh his left foot on a stool whose top is 65 cm. lower than
the table-top. His left hand is on the patient's sterile-covered
scalp, the thumb on the forehead, the fingers under the occiput,
making forced extension. The right forearm passes under the neck of
the patient, so that the index finger of the right hand holds the
bite-block in the left corner of the patient's mouth. The fingers of
the operator's right hand pulls the upper lip out of all danger of
getting pinched between the teeth and the laryngoscope. This is a
precaution of the utmost importance and the trained habit of doing it
must be developed by the peroral endoscopist.]
_Position for Bronchoscopy and Esophagoscopy_.--The dorsally recumbent
patient is so placed that the head and shoulders extend beyond the
table, the edge of which supports the thorax at about the level of the
scapulae. During introduction, the head must be maintained in the same
relative position to the table as that described for direct
laryngoscopy, that is, elevated and extended. The first assistant, in
this case, sits on a stool to the right of the patient's head, his
left foot resting on a box about 14 inches in height, the left knee
supporting the assistant's left hand, which being placed under the
occiput of the patient maintains elevation and extension. The right
arm of the assistant passes under the neck of the patient, the bite
block being carried on the middle finger of the right hand and
inserted into the left side of the patient's mouth. The right hand
also prevents rotation of the head (Fig. 51). As the bronchoscope or
esophagoscope is further inserted, the head must be placed so that the
tube corresponds to the axis of the lumen of the passage to be
examined. If the left bronchus is being explored, the head must be
brought strongly to the right. If the right middle lobe bronchus is
being searched, the head would require some left lateral deflection
and a considerable degree of lowering, for this bronchus, as before
mentioned, extends anteriorly. During esophagoscopy when the level of
the heart is reached, the head and upper thorax must be strongly
depressed below the plane of the table in order to follow the axis of
the lumen of the ventrally turning esophagus; at the same time the
head must be brought somewhat to the right, since the esophagus in
this region deviates strongly to the left.
[FIG. 51.--Position of patient and assistant for introduction of the
bronchoscope and esophagoscope. The middle of the scapulae rest on the
edge of the table; the head and shoulders, free to move, are supported
by the assistant, whose right arm passes under the neck; the right
middle finger inserts the bite block into the left side of the mouth.
The left hand, resting on the left knee maintains the desired degree
of elevation, extension and lateral deflection required by the
operator. The patient's vertex should be 10 cm. higher than the level
of the top of the table. This is the Boyce position, which has never
been improved upon for bronchoscopy and esophagoscopy.]
[FIG. 52.--Schema of position for endoscopy.
A. Normal recumbency on the table with pillow supporting the head.
The larynx can be directly examined in this position, but a better
position is obtainable.
B. Head is raised to proper position with head flexed. Muscles of
front of neck are relaxed and exposure of larynx thus rendered easier;
but, for most endoscopic work, a certain amount of extension is
desired. The elevation is the important thing.
C. The neck being maintained in position B, the desired amount of
extension of the head is obtained by a movement limited to the
occipito-atloid articulation by the assistant's hand placed as shown
by the dart (B).
D. Faulty position. Unless prevented, almost all patients will heave
up the chest and arch the lumbar spine so as to defeat the object and
to render endoscopy difficult by bringing the chest up to the
high-held head, thus assuming the same relation of the head to the
chest as exists in the Rose position (a faulty one for endoscopy) as
will be understood by assuming that the dotted line, E, represents the
table. If the pelvis be not held down to the table the patient may
even assume the opisthotonous position by supporting his weight on his
heels on the table and his head on the assistant's hand.]
In obtaining the position of high head with occipito-atloid extension,
the easiest and most certain method, as pointed out to me by my
assistant, Gabriel Tucker, is first to raise the head, strongly
flexed, as shown in Fig. 52; then while maintaining it
there, make the occipito-atloid extension. This has proven better
than to elevate and extend in a combined simultaneous movement.
If the patient would relax to limpness exposure of the larynx would be
easily obtained, simply by lifting the head with the lip of the
laryngoscope passed below the tip of the epiglottis (as in Fig. 55)
and no holding of the head would be necessary. But only rarely is a
patient found who can do this. This degree of relaxation is of course,
present in profound general ether anesthesia, which is not to be
thought of for direct laryngoscopy, except when it is used for the
purpose of insertion of intratracheal insufflation anesthetic tubes.
For this, of course, the patient is already to be deeply anesthetized.
The muscular tension exerted by some patients in assuming and holding
a faulty position is almost as much of a hindrance to peroral
endoscopy as is the position itself. The tendency of the patient to
heave up his chest and assume a false position simulating the
opisthotonous position (Fig. 52) must be overcome by persuasion. This
position has all the disadvantages of the Rose position for endoscopy.
[FIG. 53.--The author's position for the removal of foreign bodies
from the larynx or from any of the upper air or food passages. If
dislodged, the intruder will not be aided by gravity to reach a deeper
lodgement.]
The one exception to these general positions is found in procedures
for the removal of foreign bodies from the larynx. In such cases,
while the same relative position of the head to the plane of the table
is maintained, the whole table top is so inclined as to elevate the
feet and lower the head, known as Jackson's position. This
semi-inversion of the patient allows the foreign body to drop into the
pharynx if it should be dislodged, or slip from the forceps (Fig. 53).
[82] CHAPTER VII--DIRECT LARYNGOSCOPY