CHAPTER III

_Wiring, Circuits and Troubles_

=The Wire.= The size of the copper wire used in bell work is No. 16, or

No. 18, B and S gauge, and sometimes smaller, such as No. 20 to 22. But

smaller wire than No. 18 has too much resistance, and would necessitate

a larger battery power, even if its mechanical strength were not too

low. The insulating coverings are cotton saturated with paraffin wax or

compounds.

The covered wires are variously known as annunciator, office, or

weatherproof wire, these terms being mostly for distinction of the

coverings and not for the use to which the wire would be put.

Annunciator wire has two layers of cotton merely wrapped around the

copper and then saturated with paraffin.

Office wire has the two cotton layers braided, the inside one being

filled with a moisture-repelling compound.

Both office and annunciator wires have their outside coverings filled

with paraffin and highly polished.

From the ease with which annunciator wire is stripped of its cotton

covering, the braided office wire is to be preferred. These coverings

are made in a variety of colors.

Weatherproof covered wire is mostly used for electric light work, but

the sizes given above are good for bell work, although their larger

outside diameter makes them harder to conceal.

The approximate number of feet to the pound of office and annunciator

wire is given in the table.

=======================================

Office Wire. | Annunciator Wire.

----+--------------+-----+-------------

No. | Feet per lb. | No. | Feet per lb.

----+--------------+-----+-------------

12 | 35 | 18 | 180

14 | 55 | 20 | 225

16 | 95 | |

18 | 135 | |

=======================================

=Joints.= Upon the care with which a joint is made much depends, a

loose or poorly made joint will offer much resistance to the current.

The correct way to start a joint in annunciator, or office, wire is

shown in Fig. 22. About three inches of each wire to be joined is bared

of its insulation and scraped bright. The ends are then bent at right

angles to each other, hooked together and one end firmly twisted around

the other, as shown in Fig. 23. Any projecting pieces are cut off, and

the joints should then be _soldered_ to prevent corrosion.

[Illustration: FIG. 22

FIG. 23

FIG. 24]

Adhesive tape (“friction tape”) is wrapped around the joint, Fig. 24,

and pressed firmly together so that there is no chance of its

unravelling. The tape wrapping should extend across the joint and on to

about a half inch of the insulation around each wire.

=Running the Wires.= To detail all the operations of installing a

complex system of bell, alarm and annunciator wires would be impossible

from the reasons that conditions vary and space is limited. General

directions will then only be given to enable the inexperienced to run

such wires as may be needed in ordinary domestic work and to guard

against the most common causes of failure.

Wires may be run in tin tubes to prevent the depredations of rats and

mice, or they may be run with simply their own covering for protection;

it is presumed the latter is undertaken.

In a case where the building is of frame and in course of erection the

task is much simplified.

Having first decided upon the plan, number of bells, pushes, etc.

and their location, proceed to run the wires first in order that the

pushes, bells, etc. may not be injured.

But where the house is already occupied, as in the majority of cases

likely to be met with by the reader, the bell and battery may be set

first.

Take the case of an ordinary door bell with the push at the front door,

the bell in the kitchen and the battery in the cellar. If possible get

the wire on two spools; it will simplify matters if both wires are of

different colors. Starting at the push, have a foot of each wire for

connection and slack, and fasten each wire lightly to the woodwork

with staples, or double-pointed tacks, never putting two wires

under one staple nor driving in a staple so it cuts the insulation.

Some cases will require a staple about every foot, on straight runs

sometimes every three feet.

In many cases the wires can be partly concealed in the angle between a

moulding and the wall, or even in a groove of the moulding itself. When

running along a skirting, the wires may often be pushed out of sight

between it and the floor. Do not attempt to draw the wires too tight

or the changes of the weather may break the wires when the woodwork

shrinks or swells.

The wires will be, one from the push to the bell, one from the push to

the battery, and one from the bell to the battery. So it is probable

that the second wire can be run right through a small hole bored in

the flooring under the push, but inside the front door. In this case

it will be perhaps easier if the spool be left in the cellar and the

end of the wire be pushed up from below and stapled to the woodwork

near the push, leaving the cellar work to the last. Only one wire will

be run then direct to the bell upstairs and it can be better concealed

than two.

If necessary it may be drawn under a carpet and not stapled, or it can

often be forced into the crack between two boards. But if not, run it

along the skirting, following the walls until it reaches below the

bell. It is often better to go entirely around a room than to cross

below a door.

If a door must be crossed the wire may either run up one side of the

frame and down the other or laid beneath the carpet on the sill. The

former is preferable, but takes more wire.

In many houses the bell wire as well as the battery wire may be run

across the cellar beams (Fig. 25), in which case bore a second hole for

it near the push; do not draw it through the same hole as the push to

battery wire. And, of course, here work upwards with the spool in the

cellar.

Having reached the bell location, run the third wire down into the

cellar to the battery. Now connect up the push, baring an inch or so

of each wire, push them through the holes provided in the push base,

screw down the push base and clamp the wires under the washers through

which the connection screws run. Do this neatly, be sure the ends of

the wires do not stick out, cut off what is left free of the bared

ends. Then connect the battery to the wire from the push and the wire

from the bell. The last thing is to scrape and fasten the bell wires to

the bell binding posts. Do this so that they cannot come loose and that

they make good contact.

[Illustration: FIG. 25]

The bell should now ring properly when the push is pressed.

To sum up, one wire leads from one spring of the push to the bell, one

wire from the other spring of the push to the battery, and another wire

from the remaining binding post on the bell to the remaining binding

post on the battery. It is immaterial whether the zinc terminal or the

carbon terminal go to the bell or push.

=Combinations of Bells and Pushes.= One of the wires in a bell circuit

may be replaced by the ground (Fig. 26). Connection may be made to a

gas or water pipe or to a metal plate buried deep in damp earth. Any

wire fastened to such a plate must be thoroughly soldered to it or a

voltaic action will be set up, which will eat it away at the point of

contact.

[Illustration: FIG. 26]

When one bell is to be rung from two or more points the pushes are to

be connected in multiple (Fig. 27) as if they were in series; all

would have to be closed to complete the circuit.

[Illustration: FIG. 27]

[Illustration: FIG. 28]

If two bells are to be operated from one push they may be in series

(Fig. 28), but in this case one of them must be arranged for single

stroke. If both were vibrating bells the armature of one would not

vibrate in unison with the other armature and the result would be

irregular contact breaking and intermittent ringing.

[Illustration: FIG. 29]

A preferable connection for two or more bells and one push is Fig. 29,

where the bells are in multiple. This requires more current than the

series method.

[Illustration: FIG. 30]

[Illustration: FIG. 31]

To ring two bells from either one of two points, the arrangement in

Fig. 30 will answer. It requires only two wires or one wire and ground

return, but two batteries. As both bells are in multiple both will

ring, the one nearest the push being depressed ringing the loudest.

This is a disadvantage. If the series arrangement in Fig. 31 be

selected, one bell must be arranged for single stroke. Both bells will

ring with equal power.

[Illustration: FIG. 32]

In Fig. 32 only the distant bell rings, the circuit having only one

battery but three wires, or two wires and ground return.

A plan where two batteries are needed but only two wires, or one wire

and ground is in Fig. 33. Double contact or three-point pushes are

necessary here, making one contact when depressed and a second one when

not being touched.

[Illustration: FIG. 33]

In this figure only the distant bell rings.

=Faults in Bells.= On examining many electric bells it will be noted

that only one binding post is insulated from the frame when the latter

is of iron (Fig. 34). As the armature spring _S_ is in electrical

connection with the frame _F_ by reason of its metal screws and

support, the circuit may run from the insulated post _U_ to the magnet

coils, thence through the insulated contact screw _C_ through the

armature spring (when it is making contact) and through the frame to

the uninsulated post _I_.

[Illustration: FIG. 34]

This saves labor, wire and complication, but if the insulation of the

post _U_, the wires _W V_, or the contact screw _C_ be injured, the

current may take a short path back to the frame.

If _C_ were thus grounded, the bell would act as a single-stroke bell.

If _U_ were grounded, the bell would not ring at all, as that would be

a short circuit on the battery between _I_ and _U_ and the latter would

also result if the bare wire were touching the frame at _V_.

If the bare wire touched the frame beyond _M M_, that is, along _W_, it

would be a single-stroke bell, as if _C_ were grounded.

As any one of these faults is likely to occur, they should be looked

for when the bell acts imperfectly, or not at all.

A very common fault in a bell is when its armature sticks to the cores

and thus does not make contact with the contact screw. This may be from

a weak spring or because of the loss of the pieces of brass inserted in

the ends of the cores to keep the armature away from actual contact. A

piece of a postage stamp stuck over the core end will often help out in

the latter case.

A high screeching noise from the armature vibrating too rapidly but

with too little play, may be from excessive battery power or the

contact screw being too far forward. The former will generally be

detected by the violent sparking as well as the rapid vibration.

In very cheap bells the platinum contacts may be replaced by German

silver or some other metal.

Platinum is necessary because the sparking would soon corrode other

metals, but it is very expensive. To test for platinum put a tiny drop

of nitric acid on the suspected metal. If bubbles or smoke appear it is

not platinum. After applying this test in any case however, carefully

wash off and remove all traces of the acid, as it will corrode the

metal into which the platinum is riveted.

Dirty contacts will decrease the current in the bell coils and it will

not work well, if at all.

Loose contact screws and wires also give trouble. The adjusting of

the contact screw is of the utmost importance, and should never be

attempted unless it is clearly necessary.

=Faults in Line.= In looking for a fault in a bell circuit make sure

the battery is working; if only one or two cells, put the ends of two

wires attached to the terminals on the tongue: a metallic taste will

indicate current.

Then see that the circuit wires are firmly clamped in the terminals and

no dirt or corrosion on the connections.

Next examine the push button and see that the wire connections at the

springs are perfect.

If there is no movement of the bell at all when the push is pressed

in, take a pocket knife or screw driver, and touch the blade across

the push springs. If there is current flowing sparks will be seen when

the blade breaks contact between the springs. If there are no sparks,

detach the wires from the bell and twist the bare ends together. Then

try again for sparks--they may now be very minute. The tongue test is

good here.

If current is detected, examine the bell for the defects first

mentioned.

But if no current is found at the push now the wires are broken

somewhere.

First short circuit the push springs by inserting a knife blade or

piece of wire so as to touch both of them. Then touch the two wires

at the bell, one to each side wire coming from the magnet coils. If

current is up to the bell and the coils are all right, a single stroke

should result.

Replace the wires in the binding posts, clean the platinum on both

contact screw and armature spring and try the adjustment. Troubles in

the bell will be mostly similar to those before mentioned.

If no current has been obtained at either bell or push, and the battery

is in good working order, the line must be tested for a cross or break.

If the wires are touching each other (Fig. 35) at some bare spot _S_

between the bell and the battery, it will be shown by the metallic

taste upon detaching one wire from the battery and laying it on the

tongue _T_, together with another wire _W_ from the disconnected

terminal of the battery. The current will travel from the battery to

the cross at _S_, then back along the second circuit wire to the tongue

and through the short wire to the battery.

[Illustration: FIG. 35]

If no current is obtained in this way it is probable that the wire is

broken.

[Illustration: FIG. 36]

The easiest way to find this is to take a bell to the battery and

connect it between the circuit wires and the battery (Fig. 36).

Then with a sharp knife carefully cut away a little piece of the

insulation from each wire beyond the bell and battery and short circuit

the bared spots with the knife blade _K_. Keep working towards the

push. The bell will ring each time at _K K_ until the break _D_ is

passed, at _C_ it will not. It becomes an easy matter then to locate it.

[Illustration: FIG. 37]

If the bell and push are far apart, as in Fig. 37, a break between the

push and the bell may be found as shown. With the knife blade _K_ at

different points the bell will ring, but after passing the break _D_ it

will not ring.

Such simple tests as are here given can be carried out by any one, but

far better results will be obtained if the reason for each is first

learned.

This can be readily done by a careful study of the diagrams and text.